Field-testing procedure of

Similar documents
Field testing Procedure LANmark-6A

INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector S-FTP STP

White Paper: Ensure Accuracy and Maximize the Value of Your Cable Testing Equipment with Calibration from Fluke Networks

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

Support. EMROL Your power partner

WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

New Tire Fill Alert System Pumps Up Tire Inflation

Wheel Alignment VISUALINER 3D ARAGO SC

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

EUROPEAN UNION AGENCY FOR RAILWAYS Annex 1 006REC1025 V 1.0

Revision Transmittal Sheet

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

IDEAL INDUSTRIES, Inc. Certified - LanTEK Test Report

E/ECE/324/Rev.2/Add.108/Rev.1/Amend.3 E/ECE/TRANS/505/Rev.2/Add.108/Rev.1/Amend.3

Microgeneration Installation Standard: MCS

Visualiner 3D-MB. Wheel Aligners. Mercedes Benz Wheel Alignment

Getting Started HONDA

Operation manual. ABS 911 GT3 Cup Gen.II MTH Version _V1_2018/02

Product Bulletin. Be Certain with Belden. Belden DataTwist 1200 Cables

VITALink Taped Splice Pigtail Crimp

Fluke 438-II Power Quality and Motor Analyzer

DESCRIPTION This work consists of measuring the smoothness of the final concrete or bituminous surface.

IFTA LAW ENFORCEMENT COMMITTEE BEST PRACTICES GUIDE OCTOBER 2016 IFTA

2004, 2008 Autosoft, Inc. All rights reserved.

Rental Industry Safety Tester Safe Check 5s

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

TDG-F-113 CEC New Test Development Proposal for a New Engine Fuels Test Procedure

Visualiner 3D-MB Gen II Wheel Aligners. Mercedes-Benz Wheel Alignment

CERTIFIER MODEL 912 CERTIFIER 912 Brake Timing Test

TEK Brief July Is there a difference in installation requirements between communications cables with and without the LP designation?

X117E. X117E Contact-Less Valve Position Transmitter INSTALLATION / OPERATION / MAINTENANCE MODEL. X117E Contact-Less Valve Position Transmitter

Electronic Logging Device (ELD) Rule

Issue 2.0 December EPAS Midi User Manual EPAS35

ISO INTERNATIONAL STANDARD. Straight cylindrical involute splines Metric module, side fit Part 2: Dimensions

Data sheet Patch cord Cat.6 A AWG m gray

A [2].008 LPR 0002(RJ45 M).000 ATR PC P [2] PC ETR PRODUCT SPECIFICATION: CONSISTING OF DOCUMENTS:

Construction and Connection of Street Light Assets

MCS. Important Information on MCS 012 Issue 2.1 for MCS Solar Photovoltaic and Solar Thermal Contractors. Last Updated: 25 th September 2017

PRE-RELEASE VERSION (FDIS)

ISO INTERNATIONAL STANDARD

DEPARTMENT OF DEFENSE INTERFACE STANDARD

Cummins South Pacific Service Bulletin

ANNEX 7. RESOLUTION MEPC.182(59) Adopted on 17 July 2009

Get Fiber Smart. Part 1 : Best Practices in Enterprise Fiber Connectivity. Part 3: Best Practices in Tier2 Enterprise Fiber Link Testing and

GREENER SHIPPING SUMMIT 2017

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

Megohmmeter Test Probe

PUMP CENTRE CONFERENCE TELFORD, MAY 11 TH 2017 ABB Ability Smart Sensor Motors that let you know when it's time for a service

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

U/FTP vs F/UTP CAT6A LAN Cables June 2016

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

UNITED STATES COAST GUARD OCEAN ENGINEERING DIVISION WASHINGTON, D.C. JANUARY 2011 SPECIFICATION FOR THE MANUFACTURE

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

Battery fitting made easy

Subaru L Turbo

Data sheet Patch cord Cat.6 A AWG m black

EMS ELONGATION MEASUREMENT SYSTEM. Strain measurement system for wind turbines optimizing the control & condition monitoring

Progress Report DTP Subgroup Lab Process Internal Combustion Engines (LabProcICE) Geneva,

SUBJECT: Long Engine Crank Time And/Or MIL Illumination Due To DTC P0340 / P0344

TYPE CERTIFICATE DATA SHEET

OVERFILL PREVENTION DEVICE

This section covers the comprehensive range of Torque Calibration equipment manufactured by Gedore Torque.

Overview of operation modes

ISO INTERNATIONAL STANDARD

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

Proxy Lookup Service of the Bank of Lithuania. Market Infrastructure Department Banking Service

Laboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET

Installing Power Components

Avanti J Series Centrifuges Preinstallation

Certificate of Calibration

When you finish the running, power off the receiver BEFORE turning off the transmitter.

* * * Brussels, 9 February 2015

D. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

MIT515, MIT525, MIT1025, MIT1525

Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords

ISO :2015/DAM 1

Technical Information Omnigrad TST90, TET90

3820 Pressure Switch-Transmitter

ISO 3934 INTERNATIONAL STANDARD

Visualiner 3D 1, 3D 2 X-Cel Series

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

RESOLUTION MEPC.198(62) Adopted on 15 July GUIDELINES ADDRESSING ADDITIONAL ASPECTS TO THE NOx TECHNICAL CODE 2008 WITH REGARD TO

Cost-Benefit Analysis of Options for Certification, Validation and Monitoring and Reporting of HDVs

Testing Lead-acid fire panel batteries

Certificate of Accreditation

2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

CarePacs. Traceable Balance Testing for Secure Weighing Processes

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

Coriolis Flowmeter with Model 1700 or Model 2700 Transmitter

Instruction of connection and programming of the VECTOR controller

ISO/TC 131/SC

CONNECTED SERVICEs TACHOGRAPH SOLUTIONS

Multifunction Electronic Load (EBC-A10) User Manual EBC-A10 User Manual Copyright (C) ZKE Technology

ABB Motors and Generators Training. Sharing knowledge and creating value

Transcription:

Field-testing procedure of LANmark-7A Technical Paper Nexans Cabling Solutions January 2012 Revision 1.45

Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent link testing vs. Channel testing 4 2.3 Category 7A and connecting hardware 5 2.4 Installation models 5 2.4.1 Two connectors: Interconnect TO 5 2.4.2 Three connectors: Cross connect TO 6 2.4.3 Three connectors: Interconnect - CP TO 7 2.4.4 Four connectors: Cross connect - CP TO 8 2.4.5 Summary 8 3 What equipment is available to test for compliance? 9 3.1 Level IV tester 9 3.1.1 Care of the tester and leads 9 3.2 Tester Adapters and limits 10 3.2.1 User of CLASS F Tester adapters and limits 11 3.3 Selecting the correct cable type 12 3.4 Before you go to site 12 4 Understanding the test results 13 4.1 What the test results show 13 4.2 What to do with the result - Warranty Certification 13 Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 2

1 Introduction The purpose of field testing is to validate the installation against both the requirements of the standards and the demands of the Nexans warranty process. This document serves to describe how to test LANmark-7A cabling systems and to validate the installation against the international standards ISO/IEC 11801:2002/Amd 2:2010/Cor 1:2010 and CENELEC EN 50173. By doing so, the LANmark CLASS FA warranty can be achieved. If testing shows any errors or failures in the results the information gathered should be used to identify the source of the problem so that the installer can rectify and re-test. To qualify for the Nexans warranty all Channels in an installation shall be tested, and all shall pass. You should agree with the client before starting the contract how to deal with marginal pass results, as they may not be aware that a marginal result may be because of the accuracy and tolerances of the tester. As the marginal test results are indicating that the result is within the range inaccuracy and tolerances of testers, Nexans recommends to treat a marginal FAIL as FAIL and marginal PASS results as PASS. For its warranty procedure Nexans will accept a marginal PASS and reject a marginal FAIL. Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 3

2 How to proceed? 2.1 Introduction This procedure is meant as a support tool for field-testing copper cabling networks. The definitions in the standard ISO/IEC 11801:2002 are applied into practical recommendations. After describing some general definitions, the second half of this chapter is especially focused on measuring Class FA links. The procedure is to be followed in case of applying for Nexans Certified System Warranty. 2.2 Permanent link testing vs. Channel testing In the ISO standards two different ways of testing are described. A permanent link is the fixed part of the cabling, which is tested after installation, these test results give information on installation quality. The permanent link extends from the patch panel in the cabinet to the telecommunications outlet at the user side. It excludes work area cords, equipment cords and cross connections, but does include the optional consolidation point. A channel represents the complete end-to-end path between the user equipment (PC, phone, video, printer ) and the active equipment at the cabinet side (switch, hub, PBX, video equipment). The channel includes the work area cord, the equipment cord and the cross-connection. For LANmark-7A channel testing is required as no Permanent Link test head is currently available. Channel Figure 1: Model of Permanent Link and Channel testing Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 4

2.3 Category 7A and connecting hardware Before you go to the test site, please make sure to prepare your tester in accordance to the correct standard. In the next paragraphs following issues are covered: - How the different installation models of Class FA links can be tested? and - Which specific models of test-equipment and test heads can be used. 2.4 Installation models 2.4.1 Two connector model: Interconnect TO Figure 2.1: Testing at 2 connector Interconnect - TO model Figure 2.1 shows the two-connector model as described in the standard. In this installation model only Channel testing methods can be applied with the available Class FA test heads. Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 5

2.4.2 Three connector model: Cross connect TO The installation includes an Equipment cord consisting of a LANmark-7A patch cord which must be terminated using a Nexans N420.736 Snap-In connector to represent the equipment ports. Testing in a 3 connector test model as shown in Figure 2.2 is mandatory to acquire a Class FA Certified Systems Warranty on the complete installation (= 3 connector installation) under the condition that the correct test heads are used. Note: If the channel specific Equipment cord has not been installed at the time of testing, the only option is to test the 2-connector installation - see Figure 2.1. However, with this test method only a Certified Systems Warranty on the 2-connector installation can be obtained from Nexans - which must be explained to the end user / consultant prior to commencing testing. Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 6

2.4.3 Three connector model: Interconnect - CP - TO The installation includes a Consolidation Point lead consisting of a LANmark-7A patch cord which must be terminated using a Nexans N420.736 (7A) Snap-In connector connecting the Consolidation Point (CP) to the Telecommunication Outlet (TO) Testing in a 3 connector test model as shown in Figure 2.3 is mandatory to acquire a Class FA Certified Systems Warranty on the complete installation (= 3 connector installation) under the condition that the correct test heads are used. Note: If the channel specific Consolidation cord has not been installed at the time of testing, the only option is to test the 2-connector installation - see Figure 2.1. However, with this test method only a Certified Systems Warranty on the 2-connector installation can be obtained from Nexans - which must be explained to the end user / consultant prior to commencing testing. Figure 2.3: Testing at 3 connector Interconnect - CP - TO model Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 7

2.4.4 Four connector model: Cross connect - CP TO If LANmark-7A patch cords are used to cross connect the patch panels, testing as a 4-connector test model is mandatory to acquire a Nexans Certified Systems Warranty on the complete installation (= 4 connector installation). The installation includes a Consolidation point lead and an Equipment cord consisting of a LANmark-7A patch cord which must be terminated using a Nexans N420.736 (7A) GG45 connector connecting the Consolidation Point (CP) to the Telecommunication Outlet (TO) and the Cross Connect panel representing the ports on the equipment. Testing in a 4 connector test model as shown in Figure 2.4 is mandatory to acquire a Class FA Certified Systems Warranty on the complete installation (= 4 connector installation) under the condition that the correct test heads and test limits are used. Note: If the channel specific Equipment cord and Consolidation cord has not been installed at the time of testing, the only option is to test the 2-connector installation - see Figure 2.1. However, with this test method only a Certified Systems Warranty on the 2-connector installation can be obtained from Nexans - which must be explained to the end user / consultant prior to commencing testing. 2.4.5 Summary 2 connector Interconnect - TO 3 connector Cross connect - TO 3 connector Interconnect - CP - TO 4 connector Cross connect - CP - TO CH CH CH CH Class FA CH= Channel Measurement Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 8

3 What equipment is available to test for compliance? 3.1 Certified Level IV testers Test equipment must be capable of certifying Class FA links and test adapters must be approved by Nexans. Nexans strongly recommends the use of equipment with baseline accuracy that exceeds ISO/IEC 61935-1/Ed.2 (8-2005) Level IV, as indicated by independent laboratory testing. Nexans have endorsed 3 testers and configurations for use in validating the LANmark 7A / Class FA solutions against the Warranty and performance requirements on installations. At present these are: 1. Ideal Industries LanTek-II 1000 / 7G (Level IV) 2. Psiberdata WireXpert WX4500-FA (Level IV) 3. JDSU NGC-4500 Certifier40G (Level IV) - Limited CLASS F testing equipment (limited at 600 MHz) 1. Agilent WireScope Pro (CLASS F up to 600 MHz) 2. Fluke DTX 1800 (Level IV) (CLASS F up to 600 MHz) 3. Ideal LanTEK 7 (CLASS F only) The following testing guidelines are to be adhered to: All lines must be installed so that the maximum fixed link distance is 90m. All personnel must be competent with the operation of the chosen tester and be familiar with the manufacturers operating manual. 3.1.1 Care of the Tester and leads Cabling Field testers are an accurate piece of equipment and as such needs to be looked after. Please follow manufacturer recommendations for the care and maintenance of your tester. Have your tester calibrated at least once a year by the tester manufacturer. The test leads are susceptible to wear and damage. Please follow manufacturer recommendations for the care and maintenance of your test leads and do not fold or exceed the bend radius of the test cables. Do not allow the weight of the tester to be supported by the test lead. Always put your tester on charge the day before a new test job and place both units on charge overnight during the testing phase of the project. Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 9

3.2 Test Adapters and limits 1. IDEAL Industries LanTEK 7G LanTEK II 1000 Channel adapters 0012-00-00667 (GG45 CLASS FA Channel Adapter) LANTEKGG45KIT GG45 8C Measurement Cord Category 7A Screened LSZH 2m Orange (N900.67A) Limits ISO/IEC 11801 Channel CLASS FA EN 50173 Channel CLASS FA Software Version: Firmware 2.7 or higher 2. Psiber Data Wirexpert 4500 Channel adapters WX_AD_GGARJCH2 (GG45 CLASS FA Channel Smart Probe) GG45 8C Measurement Cord Category 7A Screened LSZH 2m Orange (N900.67A) Limits ISO/IEC 11801 Channel CLASS FA EN 50173 Channel CLASS FA Software Version: 3.9 or higher 3. JDSU NGC-4500 Certifier40G Channel adapters NGC4500GGARJCH2 (GG45 CLASS FA Channel Adapter) GG45 8C Measurement Cord Category 7A Screened LSZH 2m Orange (N900.67A) Limits ISO/IEC 11801 Channel CLASS FA EN 50173 Channel CLASS FA Software Version: 3.9 or higher Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 10

3.2.1 Use of CLASS F level - Test Adapters and limits (not recommended) If for some reason testers as specified in section 3.2 above are not available, provided it has been formally agreed by the end user / consultant, a 600MHz Class F tester can be used for testing against Cat7A limits up to 600MHz. Please note that the LANmark-7A Application Warranty from Nexans will be limited to 600MHz the full Cat7a 1000MHz frequency range will not be covered. 1. AGILENT Technologies Wirescope Pro - Warranty Limited to 600MHz! Channel N2644A-107 (GG45 CLASS F Channel Smart Probe) GG45 8C Measurement Cord Category 7A Screened LSZH 2m Orange (N900.67A) Limits ISO/IEC 11801 CLASS FA EN 50173 CLASS FA 2. FLUKE Networks DTX 1800 - Warranty Limited to 600MHz! Channel DTX-CHA012S GG45 Channel Adapter GG45 8C Measurement Cord Category 7A Screened LSZH 2m Orange (N900.67A) Limits ISO/IEC 11801 CLASS FA EN 50173 CLASS FA 3. IDEAL Industries LanTEK 7 - Warranty Limited to 600MHz! Channel Category 7/7A GG45 Channel Adapter (0012-00-5475X) part of 1019-00-1100 GG45 Testing Kit GG45 8C Measurement Cord Category 7A Screened LSZH 2m Orange (N900.67A) Limits ISO/IEC 11801 CLASS F EN 50173 CLASS F! Please check our website regularly to ensure you have the latest version of this paper! Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 11

3.3 Selecting the correct cable type When setting up your tester you should pay attention to the correct cable selection and the NVP (Nominal Velocity of Propagation) for the cable under test. This setting will determine the length and will therefore affect the results obtained. Some testers set themselves to pre-set or default settings each time they are switched on. You therefore must check this and configure the tester according to the cable data sheet for the product you are testing or refer to the NVP value printed on the cable outer jacket. Generally for Nexans cabling systems, the values to be used are: Commercial cable name LANmark-7 S/FTP 600MHz LANmark-7A S/FTP 1000 MHz LANmark-7A 1200 S/FTP 1200 MHz LANmark-7A 1500 S/FTP 1500 MHz NVP value 0.80 0.80 0.80 0.80 3.4 Before you go to site For all testers ensure you have the latest version of the tester firmware loaded, the update can be obtained from the manufacturer Internet site along with the latest software and limits database which should also be loaded into the tester. The firmware update and the version of the software database on the tester are important. The firmware from the tester manufacturer provides the tester with the correct parameters to test and how to interact with the test head. The software database holds the test parameters and limits for the standards that you will be comparing the cabling installation against. You must calibrate the tester local and remote ends to each other before you go to site. If you are using some testers you will also need to have the test leads calibrated onto the tester units. This will improve the accuracy of the tester. Make sure you have the latest version of the upload and diagnostic software on your PC on to which you will download the test results from the tester (available on Internet sites of the manufacturers). Always download each day s worth of test results at the end of the day onto your PC. Always put your tester on charge the day before it will be needed, afterwards place it on charge overnight during the testing phase of the project. Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 12

4. Understanding the test results 4.1 What the test results show We would all like that at first time of testing a link the results will show a pass with headroom. However the first thing most testers will show is a wire map failure. As there is an insertion life on tester heads and leads a number of installers make use of a more basic test tool which just checks for wire mapping before running with a full set of tests for CLASS FA. This releases the tester for use elsewhere and saves on head wear. If a failure is detected then make use of the tester diagnostics to locate the problem. Some of the later testers come with analysis software and tools that will locate the problem to a point along the length of the cable or at the termination. The treatment of marginal asterisked (*) results should be clarified with the client in advance. Nexans consider a *PASS as acceptable for warranty certification. A *FAIL however should be investigated and is not acceptable. 4.2 What to do with the result Warranty Certification When submitting results for the Nexans Warranty, a Nexans Warranty application form for the site has to be filled in and submitted including the original test results file to warranty.ncs@nexans.com. This warranty application form can be freely downloaded from the Nexans LANsystems website www.nexans.com/lansystems Upload and Save Which format? Ideal LanTEK 7/7G: create a backup zip file using LANTEK Reporter or *.sdf using DataCENTER Ideal LanTEK II 1000: *.sdf using Ideal DataCENTER PSIBER Data Wirexpert 4500: *.prz using ReportXpert JDSU NGC-4500 Certifier40G: *.prz using ReportXpert Fluke DTX-1800: *.flw using Fluke Linkware Agilent Wirescope Pro: *.sdf using Scopedata Pro II It is preferable to save the test results with plots if they are available on your tester as re-certification of graphical test result is only possible when plots are saved.! Please check our website regularly to ensure you have the latest version of this paper! Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 13

France Belgium UK Rue Mozart, 4-10 Alsembergsesteenweg 2, b3 2 Faraday Office Park 92587 Clichy CEDEX 1501 Buizingen Faraday Road Basingstoke RG24 8QG Tel +33 (0)1 56 69 84 00 Tel +32 (0)2 363 38 00 Tel +44 (0) 845 2300 488 Fax +33 (0)1 56 69 86 38 Fax +32 (0)2 365 09 99 Fax +44 (0) 1256 486650 Nexans - Field Testing Procedure LANmark-7A ver. 1.45 - January 2012 14