Flexible Ducts. Producent zastrzega sobie prawo do dokonywania zmian w wymiarach i danych technicznych produktów ze względu na ciągłe ich doskonalenie

Similar documents
SEMI RIGID THE PROFESSIONALS CHOICE

Silencers. ALNOR systemy wentylacji. Download Wentyle Download AlnorCAM B2B ordering

Access Products. Download Wentyle Download AlnorCAM Buy via B2B

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

Air Excellent semi-circular semi-rigid ductwork. Technical data

F LEXIBLE DUCT VERSIONS

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

SINGLE DUCT TERMINAL UNITS

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Heat recovery units type GTDHR

series Silencers

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

NOVELIS OHLER Flexrohre For safety, comfort and flexibility...

VAV Terminal Units SDS

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

to obtain the specified voids due

RockLap H&V Pipe Sections

VARYCONTROL VAV Dual Duct Terminal Boxes

FAN POWERED TERMINAL UNITS

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

ATU PRODUCT CATALOG AIR TERMINAL UNITS FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT Metal Industries, Inc.

FAN POWERED TERMINAL UNITS

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

High Performance Fan Coils FCHG Genesis Series Horizontal

CONTENTS ROUND FITTINGS AIR DIFFUSION PRODUCTS DAMPERS FLEXIBLE DUCTS

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

BRC

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Climate Recovery Duct System Technical Specifications

REK, LEK, ROK and LOK

Marine Catalogue 2014

Telephone Cables Fire Warning Cables

PH SERIES SINGLE DUCT ATU PERFORMANCE DATA

ACCESSORIES FOR DUCT FANS

ToppTube PA11 (Polyamide) page 4. ToppTube PA12 (Polyamide) page 5. ToppTube PA12HIPHL (Polyamide) page 6. ToppTube PUR 98A (Polyurethane) page 7

TPM 075/09-DK VALID FROM: 15/1/2012 FIRE DAMPER AND FIRE DAMPER-SMOKE FDMB, FDMB-SRD

Apartment ventilation

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Air diffuser system Model AUDIX -AW

FIRE DAMPERS, FIRE PROTECTION VALVES, SMOKE DAMPERS

MODULAR AIR HANDLING UNITS GAH SERIES

NR series. Circular CAV air volume control terminals with system powered mechanical regulator

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Ceiling swirl diffusers with perforated face plate

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

PELICAN Ceiling. Square ceiling air diffuser for supply air and extract air QUICK FACTS

THE PRE-INSULATED COPPER PIPES FOR DURABLE AND EASY CONNECTION OF AIR CONDITIONING UNITS

Mechanical mixing box MBM

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

technical catalogue Revision 30/4/13 1

Apartment ventilation

FAN POWERED SERIES FCI-600 CONSTANT VOLUME FAN TERMINAL UNIT SPECIFIABLE FEATURES

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Detailed Specifications & Technical Data

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

Technical documentation

PSI Anti-Corrosion Tape

BenchTop Extraction Arm FX2

ROOF FAN ROOFMASTER STEC

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table

TPM 075/09. Valid from 1/2/2016 EN 15650: FIRE DAMPER FDMB

Product catalogue 2006

Compact Grille Model KG

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

BenchTop Extraction Arm FX2

Exhaust air diffuser HPKH + Plenum box ATTS

BenchTop Extraction Arm FX2

CONSTANTFLOW Volume Flow Controllers

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

C2-2. Table of Contents DUAL DUCT TERMINAL UNITS

Volume Flow Limiters Type VFL

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Air displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225

Parts and characteristics

High-speed roll-up doors. R Series

TBV - Terminal Unit. Halton TBV. Terminal Unit

DOMESTIC USE. Anti-freeze for Piping CONSTANT POWER. Anti-freeze for Ramps. Stop Ice Constant power anti-freeze kit complete with thermostat and plug

BenchTop Extraction Arm FX2

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

Fan - Powered Terminal Unit Series Flow

Regulation and shut-off damper SPB and SPC

Access Door General Characteristics. RD Access Doors. GX Access Doors. LX Access Doors. RRD Access Doors for Round Ducts

Pressure control damper ERPA

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

Pre-made Self Regulating Trace Heating Cable Kit with Built-in Thermostat & Cold Lead INSTALLATION AND TECHNICAL MANUAL

Tubing and Accessories

Transcription:

Flexible Ducts Producent zastrzega sobie prawo do dokonywania zmian w wymiarach i danych technicznych produktów ze względu na ciągłe ich doskonalenie

About the System About the System The flexible ducts serve as a complement to ventilation ductwork. They are used for joining a series of rigid sheet metal ducts air valves or plenum boxes. They are also used for distribution of warm air from the ventilation cap and in heat recovery systems. The ducts are suited for greater dimensions of the round components to make their installation easier. When completely stretched, the ducts are 3.5 or 10m long. Installation Guide Duct clipping should be started from cutting the protection casing with a knife or scissors. After drawing apart, the duct should be cut along the internal spiral, and then split up with combination pliers. Once pulled onto a fitting or an air diffuser, the duct should be fastened with a TKS tightening band, and then the outer casing is to be wrapped up in aluminium tape. Labelling ALNOR products are furnished with the construction industry s B sign and product codes according to their technical specifications contained in this catalogue. Benefits of Use Due to their flexibility, the ducts can be deployed in hardly accessible places of the building and when it is difficult to plan how to connect boxes to the suspended ceiling. With 10-metre sections you can save time, as you do not have to work with short sections, and 120cm large cartons make their handling and storage quite easy. With its 25mm thick mineral wool insulation and a perforated tube inside, the duct also serves as a silencer. Flexible ventilation ducts ALUDUCT AD-L, ALUDUCT AD-3, SONODUCT AD-L, SONODUCT PE AD-L and IZODUCT AD-3 have hygiene certificate HK/B/0100/01/2009

ALNOR FLEX AF-AL d 1 L rated [mm] ext [mm] length L [mm] weight [kg/pcs] The flexible round ducts are a result of spiralling profiled aluminium tape which is joined using a triple overlap lock. Packaging: 3rm sections, squeezed to 1000-1300mm. Flexibility rate:minimum duct bend radius is one and half diameters or so (R=1.5D) Temperature range: 30 C to +250 C Maximum humidity: 95 % Allowable static pressure: 2000 Pa Allowable static negative pressure: 1000 Pa Flow rates: Recommended operating speed: Maximum flow rate: Fire resistance: non-combustible do 7 m/s do 25 m/s Product code: AF-AL - aaa 80 83 3000 0,34 85 88 3000 0,36 90 93 3000 0,38 100 103 3000 0,42 110 113 3000 0,47 115 118 3000 0,49 120 123 3000 0,51 125 128 3000 0,53 130 133 3000 0,55 133 136 3000 0,57 135 138 3000 0,58 140 143 3000 0,59 150 154 3000 0,63 160 164 3000 0,68 180 184 3000 0,76 200 204 3000 0,90 250 254 3000 1,13 300 304 3000 1,35 315 319 3000 1,42 355 359 3000 1,60 400 406 3000 1,80 450 456 3000 2,14 500 506 3000 2,25

STAL FLEX AF-SN d 1 L rated [mm] ext [mm] length L [mm] The flexible round ducts are a result of spiralling profiled aluminium tape which is joined using a triple overlap lock. Packaging: 3rm sections Flexibility rate: Minimum duct bend radius is one and half diameters or so (R=2,5 D) Temperature range: 30 C to +500 C Maximum humidity: 95% Allowable static pressure: 2000 Pa Allowable static negative pressure: 1000 Pa Flow rates: Recommended operating speed: Maximum flow rate: Fire resistance: non-combustible to 7 m/s to 25 m/s 80 83 3000 85 88 3000 90 93 3000 100 103 3000 110 113 3000 115 118 3000 120 123 3000 125 128 3000 130 133 3000 133 136 3000 135 138 3000 140 143 3000 150 154 3000 160 164 3000 Product code: AF-SN - aaa

ALNOR FLEX/STAL FLEX AF-AL, AF-SN Technical Data Pressure drop chart for straight sections Speed ducts m/s Losses depending on wire resistance R w diameter Volume V w m3/h

ALNOR FLEX/STAL FLEX AF-AL, AF-SN Technical Data Pressure drop chart for sections angled 90 and 45 flexion - 90 flexion - 45 Losses depending on direction change Losses depending on direction change Speed ducts W w m/s Speed ducts W w m/s Noise level in ALNOR FLEX i STAL FLEX ducts with standard diameters of 100mm to 300mm Speed ducts noise level db Noise level in db Speed ducts frequency in Hz Figure 1: Noise level in ALNOR FLEX and STAL FLEX ducts straight section frequency in Hz Figure 1: Noise level in ALNOR FLEX and STAL FLEX ducts section angled at 90 r = d

ALUDUCT AD-L ALAD-L d The ALUDUCT flexible duct is made of aluminium-polyester casing, reinforced with spirally wound steel wire. Packaging: 10rm sections, squeezed to 600mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.6 x diameter in mm. Temperature range: 20 C to + 140 C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Fire classification - E.g.-1364.3/A/06/MŻ The product is also available in GREEN series characterized by low emissions of volatile organic compounds. Code: ALAD-G-L Name: ALUDUCT-G AD-L Æd out allowable tolerance [mm] [mm] pressure [Pa] [mm] 80 82,0 2500 + 1,5 100 102,0 2500 + 1,5 125 127,0 2500 + 1,5 140 140,0 2500 + 1,5 150 152,0 2500 + 1,5 160 160,0 2500 + 2,0 180 180,0 2500 + 2,0 200 203,0 2500 + 2,0 225 229,0 2500 + 2,0 250 254,0 2500 + 3,0 280 280,0 2500 + 3,0 300 305,0 2500 + 3,0 315 315,0 2500 + 3,0 355 355,0 2500 + 3,0 400 406,0 2500 + 4,0 450 457,0 2500 + 4,0 500 508,0 2500 + 4,0 560 568,0 2500 + 4,0 630 638,0 2500 + 4,0 710 718,0 2500 + 4,0 800 810,0 2500 + 4,0 Product code: ALAD-L - aaa

ALUDUCT AD-3 ALAD-3 d The ALUDUCT flexible duct is made of aluminium casing, reinforced with spirally wound steel wire. Packaging: 10rm sections, squeezed to 800mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.6 x diameter in mm. Temperature range: 30 C to + 250 C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. The product is also available in GREEN series characterized by low emissions of volatile organic compounds. Code: ALAD-G-3 Name: ALUDUCT-G AD-3 Product code: ALAD-3 - aaa Æd out allowable tolerance [mm] [mm] pressure [Pa] [mm] 80 82,0 3000 + 1,5 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 140 140,0 3000 + 1,5 150 152,0 3000 + 1,5 160 160,0 3000 + 2,0 180 180,0 3000 + 2,0 200 203,0 3000 + 2,0 225 229,0 3000 + 2,0 250 254,0 3000 + 3,0 280 280,0 3000 + 3,0 300 305,0 3000 + 3,0 315 315,0 3000 + 3,0 355 355,0 3000 + 3,0 400 406,0 3000 + 4,0 450 457,0 3000 + 4,0 500 508,0 3000 + 4,0 560 568,0 2500 + 4,0 630 638,0 2500 + 4,0 710 718,0 2500 + 4,0 800 810,0 2500 + 4,0

ALUDUCT ALAD-L, ALAD-3 Technical Data Pressure drop chart for straight sections Losses depending on wire resistance R w Pa/m Speed ducts m/s Volume V w m3/h

Flexible duct ALAD-HY-3 The ALAD-HY-3 flexible duct is made of multilayer aluminium and polyester. Additionally its inner surface is protected against bacteria and reinforced with spirally coiled steel spring wire. The ALAD-HY-3 duct prevents growth of harmful bacteria, fungi and mould in ventilation ducts.the ALA- D-HY-3 ducts are recommended for ventilation and air-condition systems. Packing: 10 meters long sections are packed in a carton box Flexibility degree (diameter of winding): Relatively to a given diameter, e.g. circa 0,6 x diameter in mm). Range of temperature: from - 30 o C up to + 180 o C. Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter. Æd allowable tolerance [mm] out [mm] pressure [Pa] [mm] 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 150 152,0 3000 + 2,0 160 160,0 3000 + 2,0 200 203,0 3000 + 2,0 250 254,0 3000 + 3,0 315 315,0 3000 + 3,0 355 355,0 3000 + 3,0 400 406,0 3000 + 4,0 450 457,0 3000 + 4,0 500 508,0 3000 + 4,0 Product code: ALAD-HY-3 - aaa

Flexible duct ALAD-HY-L Æd The ALAD-HY-L flexible duct is made of multilayer aluminium and polyester. Additionally its inner surface is protected against bacteria and reinforced with spirally coiled steel spring wire. The ALAD-HY-L duct prevents growth of harmful bacteria, fungi and mould in ventilation ducts.the ALAD-HY-L ducts are recommended for ventilation and air-condition systems. Packing: 10 meters long sections are packed in a carton box. Flexibility degree (diameter of winding): Relatively to a given diameter, e.g. circa 0,6 x diameter in mm). Range of temperature: from - 30 o C up to + 150 o C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter. Æd 1 Æd allowable tolerance [mm] out [mm] pressure [Pa] [mm] 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 150 152,0 3000 + 2,0 160 160,0 3000 + 2,0 200 203,0 3000 + 2,0 250 254,0 3000 + 3,0 315 315,0 3000 + 3,0 355 355,0 3000 + 3,0 400 406,0 3000 + 4,0 450 457,0 3000 + 4,0 500 508,0 3000 + 4,0 Product code: ALAD-HY-L - aaa

SONODUCT AD-L ALSD-L d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT AD-L insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.75 x diameter Temperature range: 30 C to + 140 C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Noise insulation: See the attached diagram. The duct is also available without perforation IZODUCT AD-L ALID-L Fire classification - E.g.-1258.2/A/07/MŻ The product is also available in GREEN series characterized by low emissions of volatile organic compounds. Code: ALAD-G-L Name: ALUDUCT-G AD-L Code: ALID-G-L Name: IZODUCT-G AD-L Æd ext allowable tolerance [mm] [mm] pressure [Pa] [mm] 80 82,0 2000 + 1,5 100 102,0 2000 + 1,5 125 127,0 2000 + 1,5 140 140,0 2000 + 1,5 150 152,0 2000 + 1,5 160 160,0 2000 + 2,0 180 180,0 2000 + 2,0 200 203,0 2000 + 2,0 225 229,0 2000 + 2,0 250 254,0 2000 + 3,0 280 280,0 2000 + 3,0 300 305,0 2000 + 3,0 315 315,0 2000 + 3,0 355 355,0 2000 + 3,0 400 406,0 2000 + 3,0 450 457,0 2000 + 3,0 500 508,0 2000 + 3,0 560 568,0 2500 + 4,0 630 638,0 2500 + 4,0 710 718,0 2500 + 4,0 800 810,0 2500 + 4,0 Product code: ALSD-L - aaa

SONODUCT PE AD-L ALSD-L PE d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT AD-L insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. In addition, steam-tight polyester film is placed between the inner casing and the insulation. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.75 x diameter in mm. Temperature range: 20 C to + 140 C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Product code: ALSD-L PE - aaa Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82,0 2000 + 1,5 100 102,0 2000 + 1,5 125 127,0 2000 + 1,5 140 140,0 2000 + 1,5 150 152,0 2000 + 1,5 160 160,0 2000 + 2,0 180 180,0 2000 + 2,0 200 203,0 2000 + 2,0 225 229,0 2000 + 2,0 250 254,0 2000 + 3,0 280 280,0 2000 + 3,0 300 305,0 2000 + 3,0 315 315,0 2000 + 3,0 355 355,0 2000 + 3,0 400 406,0 2000 + 3,0 450 457,0 2000 + 3,0 500 508,0 2000 + 3,0 560 568,0 2500 + 4,0 630 638,0 2500 + 4,0 710 718,0 2500 + 4,0 800 810,0 2500 + 4,0

SONODUCT AD-3 ALSD-3 d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT AD-3 insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes, and 5rm sections, squeezed to 600mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.80 x diameter in mm.. Temperature range: 30 C to + 250 C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Noise insulation: See the attached diagram. The duct is also available without perforation. IZODUCT AD-3 ALID-3 Fire classification - E.g.-1364.2/A/06/MŻ The product is also available in GREEN series characterized by low emissions of volatile organic compounds. Code: ALAD-G-3 Name: ALUDUCT-G AD-3 Code: ALID-G-3 Name: IZODUCT-G AD-3 Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82,0 2000 + 1,5 100 102,0 2000 + 1,5 125 127,0 2000 + 1,5 140 140,0 2000 + 1,5 150 152,0 2000 + 1,5 160 160,0 2000 + 2,0 180 180,0 2000 + 2,0 200 203,0 2000 + 2,0 225 229,0 2000 + 2,0 250 254,0 2000 + 3,0 280 280,0 2000 + 3,0 300 305,0 2000 + 3,0 315 315,0 2000 + 3,0 355 355,0 2000 + 3,0 400 406,0 2000 + 3,0 450 457,0 2000 + 3,0 500 508,0 2000 + 3,0 560 568,0 2500 + 4,0 630 638,0 2500 + 4,0 710 718,0 2500 + 4,0 800 810,0 2500 + 4,0 Product code: ALSD-3 - aaa

SONOLIGHT AD-L ALSDL-L d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT AD-L insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific external diameter, i.e. approx. 0.75 x diameter in mm. Temperature range: 30 C to + 120 C Allowable negative pressure: Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Noise insulation: See the attached diagram. The duct is also available without perforation. IZOLIGHT AD-L ALIDL-L Fire classification - E.g.-1258.1/A/07/MŻ Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82,0 2000 + 1,5 100 102,0 2000 + 1,5 125 127,0 2000 + 1,5 140 140,0 2000 + 1,5 150 152,0 2000 + 1,5 160 160,0 2000 + 2,0 180 180,0 2000 + 2,0 200 203,0 2000 + 2,0 225 229,0 2000 + 2,0 250 254,0 2000 + 3,0 280 280,0 2000 + 3,0 300 305,0 2000 + 3,0 315 315,0 2000 + 3,0 355 355,0 2000 + 3,0 400 406,0 2000 + 3,0 450 457,0 2000 + 3,0 500 508,0 2000 + 3,0 Product code: ALSDL-L - aaa

SONOLIGHT PE AD-L ALSDL-PE-L d 1 Flexible duct, noise and heat insulated, with additionally perforated ALUDUCT insert. Insulated with a 25mm thick mineral wool, covered with aluminium-polyester film casing. In addition, steam-tight polyester film is placed between the inner casing and the insulation. Packaging: 10rm sections, squeezed to 1200mm, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.75 x diameter in mm. Temperature range: 30 C to + 120 C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Product code: ALSDL-PE-L - aaa d 1 Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82,0 2000 + 1,5 100 102,0 2000 + 1,5 125 127,0 2000 + 1,5 140 140,0 2000 + 1,5 150 152,0 2000 + 1,5 160 160,0 2000 + 2,0 180 180,0 2000 + 2,0 200 203,0 2000 + 2,0 225 229,0 2000 + 2,0 250 254,0 2000 + 3,0 280 280,0 2000 + 3,0 300 305,0 2000 + 3,0 315 315,0 2000 + 3,0 355 355,0 2000 + 3,0 400 406,0 2000 + 3,0 450 457,0 2000 + 3,0 500 508,0 2000 + 3,0

SONODUCT/SONOLIGHT Technical Data Noise attenuation curves The charts show noise levels for noise and heat insulated SONODUCT and SONOLIGHT ducts, depending on the section length: 500mm, 1000mm and 1500mm at a noise insulation thickness of approx. 25mm. Noise level db Noise level db Frequency en Frequency en Figure 1: noise level for SONODUCT/SONOLIGHT Noise insulation thickness Duct section length 25 mm 500 mm Figure 2: noise level for SONODUCT/SONOLIGHT Noise insulation thickness Duct section length 25 mm 1000 mm Noise level db Frequency en Figure 3: noise level for SONODUCT/SONOLIGHT Noise insulation thickness Duct section length 25 mm 1500 mm

IZODUCT/IZOLIGHT Technical Data Flow resistance chart for IZODUCT/IZOLIGHT ducts [Pa/m] [m] 100 80 60 50 40 80 22 30 100 20 125 18 20 180 14 16 200 10 8 6 5 250 10 9 8 12 315 355 400 4 7 500 3 6 2 flow rate [m/s] 5 1 3 4 diameter [mm] 50 100 200 500 1000 2000 5000 10000 output [m3/h]

POLYDUCT POAD Æd Flexible duct POLYDUCT is made of 30 µm thick multilayer polyester.the whole duct is reinforced with spirally coiled steel spring wire. Flexible ducts POLYDUCT are recommended for ventilation and air-condition systems as well as for heating systems. Packing: 10 m long sections are packed in carton boxes. Flexibility degree (diameter of winding): Relatively to a given diameter, e.g. from 0,6 x diameter in mm. Range of temperature: from - 30 C up to + 120 C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter.external diameter admissilble pressure allowance Product code: POAD - aaa typ Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82,0 3000 + 1,5 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 140 140,0 3000 + 1,5 150 152,0 3000 + 2,0 160 160,0 3000 + 2,0 180 185,0 3000 + 2,0 200 203,0 3000 + 2,0 224 229,0 3000 + 3,0 250 254,0 3000 + 3,0 280 280,0 3000 + 3,0 300 305,0 3000 + 3,0 355 356,0 3000 + 4,0 450 457,0 3000 + 4,0 500 508,0 3000 + 4,0 560 560,0 3000 + 1,5

POLYIZODUCT POD d 1 Flexible duct thermally insulated with 25 or 50 mm thick mineral wool. Its internal jacket is made of 30 µm thick double-layer polyester. External jacket is made of 30 µm thick double-layer metalized polyester. Additionally between the internal jacket and the insulation there is steamproof foil. External jacket is reinforced with spirally coiled steel spring wire. Packing: 10 m long sections are packed in carton boxes. Flexibility degree (diameter of winding): Relatively to a given diameter, e.g. from 0,8 x diameter in mm. Range of temperature: from - 30 C up to + 120 C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter.external diameter admissilble pressure allowance Product code: POD - aaa typ d 1 Æd ext allowable tolerance rated [mm] [mm] pressure [Pa] [mm] 80 82,0 3000 + 1,5 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 140 140,0 3000 + 1,5 150 152,0 3000 + 1,5 160 160,0 3000 + 2,0 180 185,0 3000 + 2,0 200 203,0 3000 + 2,0 225 229,0 3000 + 2,0 250 254,0 3000 + 3,0 280 280,0 3000 + 3,0 300 305,0 3000 + 3,0 315 315,0 3000 + 3,0 355 356,0 3000 + 3,0 400 406,0 3000 + 3,0 450 457,0 3000 + 3,0 500 508,0 3000 + 3,0 560 560,0 3000 + 3,0

Flexible duct ALID-HY-3 Æd The ALID-HY-3 duct is thermally insulated with 25 mm thick mineral wool. Its external and internal jackets are made of multilayer aluminium and polyester. Additionally the internal jacket is protected against bacteria and reinforced with spirally coiled steel spring wire. The ALID-HY-3 insulated duct prevents growth of harmful bacteria, fungi and mould in ventilation ducts. The ALID-HY-3 insulation ducts are recommended for ventilation and air-condition systems. Packing: 10 meters long sections are packed in a carton box. Flexibility degree (diameter of winding): Realtively to a given diameter, e.g. from 0,8 up to 1,1 x diameter in mm. Æd Æd allowable tolerance nom [mm] out [mm] pressure [Pa] [mm] 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 150 152,0 3000 + 2,0 160 160,0 3000 + 2,0 200 203,0 3000 + 2,0 250 254,0 3000 + 3,0 315 315,0 3000 + 3,0 355 355,0 3000 + 3,0 400 406,0 3000 + 4,0 450 457,0 3000 + 4,0 500 508,0 3000 + 4,0 Range of temperature: from - 30 o C up to + 180 o C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter. Product code: ALID-HY-3 - aaa

Flexible duct ALID-HY-L Æd The ALID-HY-L duct is thermally insulated with 25 mm thick mineral wool. Its external and internal jackets are made of multilayer aluminium and polyester. Additionally the internal jacket is protected against bacteria and reinforced with spirally coiled steel spring wire. The ALID-HY-L insulated duct prevents growth of harmful bacteria, fungi and mould in ventilation ducts. The ALID-HY-L insulation ducts are recommended for ventilation and air-condition systems. Packing: 10 meters long sections are packed in a carton box. Flexibility degree (diameter of winding): Realtively to a given diameter, e.g. from 0,8 up to 1,1 x diameter in mm. Æd Æd allowable tolerance nom [mm] out [mm] pressure [Pa] [mm] 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 150 152,0 3000 + 2,0 160 160,0 3000 + 2,0 200 203,0 3000 + 2,0 250 254,0 3000 + 3,0 315 315,0 3000 + 3,0 355 355,0 3000 + 3,0 400 406,0 3000 + 4,0 450 457,0 3000 + 4,0 500 508,0 3000 + 4,0 Range of temperature: from - 30 o C up to + 180 o C Admissible negative pressure: depending on position of the duct. In straight sections it can be assumed 1/3 of carried pressure for each diameter. Product code: ALID-HY-L - aaa

Flexible duct PVC-A Æd COMBIAFS is produced from multi aluminium layer covered with a nonflammable and airtight PVC jacket, made of a 45 micron thickness. COMBIAFS is reinforced with high tension steel spring wire. Produced for discharging welding fumes and dense chemical gases where high mechanical resistance is required. COM-F flexible air ducts are recommended for ventilation, air-conditioning and heating systems. Packing: 10rm sections, packed into cardboard boxes. Flexibility rate (winding diameter): Relative to a specific diameter, i.e. approx. 0.6 x diameter in mm. Temperature range: 30 C + 150 C Allowable negative pressure: Depending on duct position. For straight sections, you can assume 1/3 of transmitted pressure per diameter. Product code: PVC-A - aaa Æd Æd dozwolone tolerancja nom [mm] zew [mm] ciśnienie [Pa] [mm] 80 82,0 3000 + 1,5 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 150 152,0 3000 + 1,5 160 160,0 3000 + 2,0 180 185,0 3000 + 2,0 200 203,0 3000 + 2,0 225 229,0 3000 + 2,0 250 254,0 3000 + 3,0 300 305,0 3000 + 3,0 315 315,0 3000 + 3,0 355 356,0 3000 + 3,0 400 406,0 3000 + 4,0 450 457,0 3000 + 4,0 500 508,0 3000 + 4,0 560 568,0 3000 + 4,0 630 638,0 3000 + 4,0 710 718,0 3000 + 4,0 800 810,0 3000 + 4,0

COMBIFLEX COM-F Æd The COMBIFLEX flexible duct is made of multilayer aluminium, tightly covered with non-flammable 110 micron PVC jacket. It s construction is reinforced with spiral steel spring wire. No vapour condensation is an advantage of this of ducts. Moreover the COMBIFLEX duct can be cleaned easily, is resistant to chemicals and UV radiation. The COMBIFLEX flexible ducts are recommended for ventilation and air-conditioning systems as well as for heating installations. Packaging: 10 m sections packed in cardboard boxes Degree of flexibility (winding diameter): relative to a specific diameter i.e. ca. 0,6 x diameter in mm. Temperature range: from 30 C to + 150 C Allowable negative pressure: depending on duct position. In straight sections 1/3 of transmitted pressure per the specific diameter can be assumed. Æd allowable tolerance nom [mm] out [mm] pressure [Pa] [mm] 80 82,0 3000 + 1,5 100 102,0 3000 + 1,5 125 127,0 3000 + 1,5 150 152,0 3000 + 1,5 160 160,0 3000 + 2,0 180 185,0 3000 + 2,0 200 203,0 3000 + 2,0 225 229,0 3000 + 2,0 250 254,0 3000 + 3,0 300 305,0 3000 + 3,0 315 315,0 3000 + 3,0 355 356,0 3000 + 3,0 400 406,0 3000 + 4,0 450 457,0 3000 + 4,0 500 508,0 3000 + 4,0 Product code: COM-F - aaa

PVC ducts PVC-R-DUCT, PVC-S-DUCT Æd typ A x B A zew x B zew length allowable [mm] [mm] [m] pressure [Pa] Round and rectangular PVC ducts are made of PVC plastics of 60 micron thickness, reinforced with steel wire. They are used in heating, cooling, ventilation and air-conditioning installations. Suitable for low and medium pressures. Due to high flexibility they are suitable for installations subject to continuous vibrations. PVC-R-DUCT-100-1 100 102 1 2000 PVC-R-DUCT-100-3 100 102 3 2000 PVC-R-DUCT-100-6 100 102 6 2000 PVC-R-DUCT-125-1 125 127 1 2000 PVC-R-DUCT-125-3 125 127 3 2000 PVC-R-DUCT-125-6 125 127 6 2000 PVC-R-DUCT-150-1 150 152 1 2000 PVC-R-DUCT-150-3 150 152 3 2000 PVC-R-DUCT-150-6 150 152 6 2000 Packaging: 1m, 3m or 6 m sections, squeezed and packed in foil. Degree of flexibility (winding diameter): Relatively to a specific diameter i.e. ca. 0,6 x diameter in mm. A x B Temperature range: from 20 C to + 70 C Allowable pressure: Maximum allowed working pressure amounts to 2000 Pa Product code: PVC-R-DUCT - aaa - bbb dimension length typ A x B A zew x B zew length allowable [mm] [mm] [m] pressure [Pa] PVC-S-DUCT-55-110-1 55x110 57x112 1 2000 PVC-S-DUCT-55-110-3 55x110 57x112 3 2000 PVC-S-DUCT-55-110-6 55x110 57x112 6 2000 PVC-S-DUCT-75-150-1 75x150 77x152 1 2000 PVC-S-DUCT-75-150-3 75x150 77x152 3 2000 PVC-S-DUCT-75-150-6 75x150 77x152 6 2000

Insulated ventilation duct sleeve SLVD-25/SLVD-50 d 1 SLVD flexible duct sleeve insulated with 25 mm or 50 mm glass mineral wool, coated with aluminum and polyester sleeve. SLVD sleeve is used for insulating round or oval ducts. SLVD sleeves are highly wear-resistant, do not transmit UV radiation and are resistant to chemicals. Packaging: 5rm sections in foil-wrapped rolls, packed in a cardboard box. Temperature range: From 30 C to + 150 C The product is also available in the GREEN variant for low organic compound emission Code: SLVD-G Product code: SLVD - aaa - bbb thickness insulation d 1 d 1 nom [mm] 80 82,0 d out [mm] 100 102,0 125 127,0 140 140,0 150 152,0 160 160,0 180 180,0 200 203,0 225 229,0 250 254,0 280 280,0 300 305,0 315 315,0 355 355,0 400 406,0 450 457,0 500 508,0 560 568,0 630 638,0 710 718,0 800 810,0