005 Series. How to Order - G3 or Multipol Assembly Kit A K 3 E D 0 0 0 0 3 G A36 Electronic / Electrical Systems Type & Location 3 = T = Terminal Strip - 3 J = 5 pin SUB-D connector M = 37 pin SUB-D connector P = pin round M3 connector Q = 9 pin round M3 connector R = 6 pin round M7 connector Series* E = 005 Series Options - (3GD) IP65X - (3GD) IP5X (3G) IP5X A36 = A00 () A = A00 () A3 = A00 () D36 = DRM () D = DRM () D3 = DRM () D38 = X (3) D = X (3) D = X (3) F6 = D () F8 = D () F9 = D () () Standard (no options) () DIN Rail Mount (3) External pilot supply from port () External pilot supply from port and DIN Rail Mount Number of Valve Stations A = I = 9 B = J = 0 C = 3 K = D = L = E = 5 M = 3 F = 6 N = G = 7 H = 8 End Plate Port Type G = ISO 8/-G Tap Pressure Ports (ISO8/ Conduit Ports if applicable) 3 = 3/8 End Plate Port Size Maximum Number of Solenoid Outputs AK F AK T AK J AK M AK P AK R AK S 8 /3 3 0 00573GB-0/R0 X0-30-0
005 Series.a How to Order - Series 005 Valve 05 BB Z6 M G 7W 6 Series 05 = 005 Series Port Size of Base = G /8 or valve w/o manifold Actuator BA = Single actuated and spring return, flush non-locking manual override BB = Double actuated, flush non-locking manual override 00 = Island w/o valve (blank station) Function = 5-port., -pos. valve 5 = open center, dual pressure 6 = closed center 7 = connected with &, 3 & 5 blocked D = Dual 3-port., -pos. valve NC, NC E = Dual 3-port., -pos. valve NC, NC, vacuum service P = Indicates blank station plate Voltage 00 = Blank station plate 6 = VDC Options 7W = ATEX - Further options on request Port Type of Bases 0 = Without base G = G thread(/8 only) Wiring Option M = Plug-in, DC with LED 0 = Blank station plate Mounting 00 = Valve unit only 0 = With sandwich speed control Z = Manifold block with side and bottom ports, single solenoid, Z-Board Z = Manifold block with side and bottom ports, double solenoid, Z-Board Z5 = Z with speed control Z6 = Z with speed control R = Z with ribbon cable connector R = Z with ribbon cable connector R5 = Z5 with ribbon cable connector R6 = Z6 with ribbon cable connector 00573GB-0/R0 3 0 Ribbon cable option must be used for manifold assemblies that exceed 6 solenoids (7th and 8th digit of valve order code). BA BB BB5 Symbols 5-ported, -pos. valve, detented open center, dual pressure Symbols 3 5 3 5 BB6 BB7 BBD BBE closed center connected with &, 3 & 5 blocked Dual 3-port., -pos. valve NC, NC Dual 3-port., -pos. valve vacuum service NC, NC X0-30-
3. How to Order - G3 EP 00 R 0 7W Electronics Protocols CO = CANopen DL = DeviceLogix DN = DeviceNet EC = EtherCAT ED = EtherNET/IP DLR EM = ModBus /TCP EP = EtherNet/IP PL = POWERLINK PT = PROFIBUS-DP PN = PROFINET DS = Backplane extension Valve Manifold DS3 = Backplane extension I/O Assembly ATEX options 7W = ATEX version D5 = 7W + DRM-DIN Rail Mounting D6 = 7W + E3-Fieldbus assembly without valves F0 = 7W + E3-Fieldbus assembly without valves + DRM-DIN Rail Mounting Number of I/O Modules 00 = 0 0 = 0 = 03 = 3 0 = Modification 0 = Initial release Left Mounting D = w/ Backplane extension Out R = w/ Terminating Resistor.., 0 X0-30- 3 0 00573GB-0/R0
Example Order for a Valve Island with & Discrete Inputs For valve series 005 0 3 0 00573GB-0/R0 Shaded components are described by the assembly kit (AK) model number (see page ). The communication module and number of Input modules are described by the Electronic Interface (G3) model number designation (see page 3). Each valve station is listed in sequential order from left to right when facing the port side of the manifold as shown. Each discrete Input module (see page 3 for order codes) is listed in sequential order from right to lft starting from the communication module as shown. NOTE: The number of coils under voltage at the same time depends on the number of input modules associated with the pneumatic distribution. 50 005 input modules max. coils max. coils 0 8 0 6 9 8 3 7 0 6 580 8-5/37 Pin Sub-D -3 Terminal Strip 9 Pin Round Connector Note: Ordering Assemblies with Inputs Only. Refer to the selection table on page 3 to specify the control electronics and Input configuration.. Each discrete Input module is listed in sequential order from right to left as shown. 3. A maximum of Input modules are supported by a single communication node. Analog Input & digital Input (NPN & PNP). Example Order - Assembly Kit AK3EP00003GA36 Station 05BBZMG7W6 Station 05BBZMG7W6 Station 3 05BBZMG7W6 Station 05BBZMG7W6 Station 5 05BBZMG7W6 Station 6 05BBZMG7W6 Station 7 05BBZMG7W6.... Station 9 05BBZMG7W6 Electronics G3DN0R07W Station 0-35 - For a x3/ valve ( pneumatic functions for each valve), the coils of the valve can be supplied simultaneously, each 3/ having an independent distribution function. - For the 5/3, 5/ monostable or bistable valves ( pneumatic function for each valve), only one of the coils may be supplied during valve commutation. (Never supply the coils simultaneously). Configuration example: Fielbus island 005 with input module 5/ bistable valve = pneumatic function Max. number of coils that may be supplied simultaneously equals. 5/3 valves = pneumatic functions Max. number of coils that may be supplied simultaneously equals. 3 x3/ valves = 6 pneumatic functions Max. number of coils that may be supplied simultaneously equals 6. Total number of coils that may be supplied simultaneously = 9 correct configuration Example Order - Input assembly with Backplane extension in and backplane extension out modules Electronics G3DS30D07W Station 0-35 Station 0-35 Station 0-35 X0-30-3
X0-30- 00573GB-0/R0