TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

Similar documents
DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual

RESOL SBS 1000 * * Connection Operation

eltasol * * Mounting Connection Operation Examples

WMZ RESOL WMZ * * Mounting Connection Operation. Manual

TERMOSOL 1. Table of contents. ppa. Gerald Neuse

DeltaSol B * * Mounting Connection Operation Examples

D e lt a S o l BS * * Mounting Connection Operation Troubleshooting Examples. manual

DeltaSol BS. RESOL DeltaSol BS. Mounting Connection Handling Fault localization Examples. manual

DeltaSol AX * *

Pro. RESOL DeltaSol B Pro. Mounting Connection Handling Fault localization Examples

DeltaSol BS. RESOL DeltaSol BS * * Mounting Connection Operation Troubleshooting Examples. manual

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

Solar Controller SUNGO S

DeltaSol BS. RESOL DeltaSol BS * * Mounting Connection Handling Fault localization Examples. manual

D e lt a S o l C2 * * Mounting Connection Operation Troubleshooting Examples. Manual

SOM 6 SI SOM 6 SI. Installation, Configuration and Troubleshooting Manual. manual

DIEMASOL A. Solar regulator. Installation instructions. Instructions for use. Technical instructions. English 06/01/06

Pro. RESOL DeltaSol BS Pro. Mounting Connection Handling Fault localization Examples

BS Plus. D e lt a S o l BS Plus * * Mounting Connection Operation Troubleshooting Application examples. Manual

BW-HE. Roth BW-HE * * Installation Operation Commissioning. Manual

ANS 21-PV. Simple solar control unit Photovoltaik version. Operation Installation instructions. Version 11 EN. Manual version 2

* * Mounting Connection Handling Fault localization Examples. manual

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Solar Controller SUNGO S

DeltaSol Pool. RESOL DeltaSol Pool * * Mounting Connection Operation. Manual

DeltaSol BS Pro. RESOL DeltaSol BS Pro * * Mounting Connection Handling Fault localization Examples. manual

ANS 21. Simple solar control unit. Operation Installation instructions. Version 10 EN. Manual version 3

Heat Meter Integrator

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

BS Plus. D e lt a S o l BS Plus * * Mounting Connection Operation Troubleshooting Application examples. Manual

Electrical operating instructions

Emergency lighting units PC COMBO

Emergency lighting units PC COMBO

Ex m Solenoid Operator Type 0519


Electronic tank monitoring device (complete kit) - for battery tanks - incl. overfill safety - after TRwS 791(-2) with clearance display

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

LED Driver Compact fixed output

LED Driver Compact fixed output

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

SOLAR CHARGE CONTROLLER

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

User Manual. Solar Charge Controller 3KW

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

Start-up instructions

Overview of types. Technical data

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

G2515. Installation. Place of installation. Electrical installation. Permissible cable lengths. Securing the controller to the base

Wilo-Control SC-Fire Jockey

Operating manual UPS - System

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

GEIGER-SOLIDline* GEIGER-Touch (GU45..M) for rolling shutters, awnings and screens. Bedienungsanleitung. Operating Instructions. Manuel d utilisation

DeltaSol CS/4 * * Manual for the specialised craftsman. Solar controller. Installation Operation Functions and options Troubleshooting

Compact System NRGS 11-2 NRGS Original Installation Instructions English

HERZ Electronic room thermostat analog and digital

User Manual Rittal PMC UPS 6kVA

zelsius Installation and operating manual All that counts EnergyMetering

User Manual Solar Charge Controller 3KW

ZB0050 / ZB0051 ZB0070 / ZB0071

GEIGER-GJ56.. with mechanical end stop For Venetian blinds and exterior blinds

Delta HE 35-XX, 55-XX

ISOLAR PLUS 12V * * Mounting Connection Operation Fault diagnostics Application examples. manual

RADIO FREQUENCY SYSTEMS

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

GL1200T Cut & Seal. (GL1200 Seal only)

Electronic Circuit Breaker ESS20-0..

Ultrasonic heat meter

2009 / 2010 PRICES.

RVD125/109 RVD145/109

THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller

Thermal flow sensor TFS-35

Assembly and operating Instructions. Bypass Flow Meter DST

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Mounting Connection Handling Fault localization Examples

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

Installation Instructions

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

GEIGER-GJ5610v1 with mechanical end stop For Venetian blinds and exterior blinds for 100 V power supply

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

D e lt a S o l BS/2. RESOL D e lt a S o l BS/2 (Version 2) * * Mounting Connection Application examples Operation Troubleshooting.

Operating Instructions

GEIGER-GJ56.. For Venetian blinds and exterior blinds

Positive displacement batch controller

Thermal flow sensor TFS-35

Clamping and drive module

Module B Module C FOR THE WEATHER CONTROLLER MULTI-MIX INSTALLATION MANUAL REVISION: 1.0_EN

Comfort 830 Operator system for sliding entrance doors

Transcription:

RESOL TLR2 Mounting Connection Handling Fault localization *48001550* 48001550 TLR2 Thanks for buying a RESOL product. Read this manual carefully to get the best perfomance from this unit. B Manual www.resol.de

Contents Safety instructions... 2 Technical data and functional survey... 3 1. Sensor types... 4 2. Installation... 5 2.1 Mounting... 5 2.2 Electrical connection... 5 3. Operation and function... 6 3.1 Setting pushbutton... 6 3.2 Control parameter and indication channels... 6 3.3 Indication channel SU... 6 3.4 Indication channel SL... 6 3.5 Indication channel HO... 6 3.6 Indication channel PG... 6 3.7 Indication channel VN... 6 3.8 Indication channel TO... 7 3.9 Indication channel TF... 7 3.10 Indication channel MM... 7 3.11 Status-LED blinking codes... 7 4. Initiation... 7 5. Tips for debugging... 8 Security advice Please pay attention to the following security advice in order to avoid danger and damage to people and property. Instructions Attention should be paid - to the statutory provisions for prevention of industrial accidents, - to the statutory provisions for environmental protection, - to the Health and Safety at Work Act 1974 - to Part P of the Building Regulations 2005 - to BS7671 Requirements for electrical installations and relevant safety regulations of DIN, EN, DVGW, TRGI, TRF and VDE. This instruction is exclusively addressed to authorised skilled personnel. - Only qualified electricians should carry out electrical works. - Initial installation should be effected by named qualified personnel Declaration of conformity We, RESOL Elektronische Regelungen GmbH, D-45527 Hattingen, declare under our sole responsibility that our product TLR2 complies with the following standards: EN 55 014-1 EN 60 730-1 According to the regulations of the above directives, the product is labelled with : 89/336/EWG 73/ 23/EWG Hattingen, 07.07.2006 RESOL Elektronische Regelungen GmbH, ppa. Gerald Neuse 2

Technical data Housing: plastic, PC-ABS and PMMA Protection type: IP 20 / DIN 40050 Ambient temperature: 0... 40 C Size: 172 x 110 x 46 mm Power supply: 220 240 V~ breaking capacity: 1 relay output (alternating relay) Schaltstrom 4(1) A Ambient temperature: -20 C... bis +40 C store nominal temperature: 20... 90 C Display: LCD, multi functioning combi display with pictogramms, two 2-digit description field and two 4-digit 7-segment-displays as well a 2-coloured LED. Installation: wall mounting, control panel-installation possible Operation: vie 3 pushbuttons in the front of the housing Inputs: 2 temperature sensors Pt1000 Degree of pollution: 2 Rating surge voltage: 2,5 kv Temp. for ball pressure check: 75 C TRL2 Electronic store charge controller, with LCD combidisplay for concurrent display of the upper and the lower store temperature for optimised charge with one energy source (e.g. central heating boiler). The temperature is collected by temperature sensors in the upper and lower part of the store. When the switch-on temperature of the upper sensor is under-run, the store is charged until the switch-off temperature is reached in the upper sensor. The controller is menu-driven. Two sensors from our product range (type Pt1000) are needed, (please order additionally) e.g. 2 x FRP150. Functioning The store charge controller RESOL TLR2 optimises the charging of a warm water- heat accumulator via one energy source, e.g. a central heating boiler. The store temprature is collected by sensors S1 and S2 in the upper resp. lower part of the store. The charging cycle starts as soon as the upper sensor S1 collects a temperature thatis lower than the preadjusted switch-on temperature. The charging occurs until the temperature of S2 (in the lower part of the store) exceeds the preadjusted switch-off temperature. Benefits: - The store is heated up completely (avoidance of danger caused by Legionellen). - The heating up of the store takes place in big intervals ; therefore longer burner running time The controller TLR2 needs two sensors from our product range. 3

1. Sensor types For the controller RESOL TLR2 precision temperature sensors in Pt1000-version (FKP and FRP) are used. FK: 1,5 m long weather- and temperatureproof siliconcable for temperatures from -50 C... +180 C, preferably for the collector. FR: 2,5 m long PVC-cable for temperatures from - 5 C... +80 C, preferably for the store. The corresponding local VDE-regualtions must be obeyed. The sensor cables carry low voltage and musn t be installed in one cable channel with cable that carry more than 50V. The sensor cables can be elongated up to 100 m, whereas the cross-section of the extensioncable must have 1,5 mm 2 (resp. 0,75 mm 2 at cable lengths up 50 m). With long cables and when using cable channels cables with twisted leads should be used. For immersion sensors immersion sleeves must be used. immersion sensor: available in different lengths (immersion depth) FK...60: 60 mm immersion depth, brass sleeve, chromiumplated FK...150: 150 mm immersion depth, brass sleeve, chromiumplated Important: push the sensor completely into the sleeve and tighten the fitting. Pipe sensor: for any pipe diameter, complete with clamping band FK...21 or FR...21 Der Sensor must have good thermal contact to the pipe. Therefore clean the contact surface carefully and apply heat conduction paste between sensor and pipe. For protection against outside temperature influences wind the sensor cable around the pipe once and insulate well. Contact sensor: for application to plane surfaces FK...9 or FR...9 Pay attention to good thermal contact. Use heat conduction paste and insulate against outside temperature influences. FK... : collector sensor FR... : reference sensor (store sensor) 4

2. Installation Attention! 2.1 mounting Ensure separation from power supply before opening the housing blind operation-controll lamp top cover combi-lcd key panel clamp base The mounting has to be made only in dry interiors. Keep in mind that the controller musn t be installed at a place where it can be influenced by strong electromagnetic fields. According to the current regulations for installation the controller must be equipped with an additional set-up which allows the separation from the power line by an isolating distance of at least 3 mm. Attend to separated laying when installing the mains connection cable and the sensor cable. 1. Unscrew the cross-head screw of the blind and pull the blind down from the housing. 2. Mark the upper attachment point on the subsurface and premount the attached dowel with the matching screw. 3. Replace the housing at the upper attachment point, mark the lower attchment point at the subsurface (hole centre distance 130 mm), afterwards fix the lower dowel. 4. Replace housing at the upper point and fix it with a attachment screw. grommet with strain relief 2.2 Electrical connection TLR2 Temp. Sensor Pt1000 S1 S2 1 2 3 4 sensor clamps PRG consumer-clamps (pump) T4A 2 (1) A (220... 240) V~ R M A N L N L 12 13 14 15 16 17 18 19 20 bridge fuse pipe clamp The power supply of the controller must be effected by an external power switch (last workstep!) and the power supply must be 220... 240 Volt (50...60 Hz). Flexible cables must be fixed to the housing with the attached strain relief clamp and the matching screws. The controller is equipped with 1 relay (change-over contact), to which the matching consumer load is attached (e.g. store charge pump): Pump-relay R1 14 = home contact R 15 = medium contact M 16 = make contact A The temperature sensors (S1 and S2) are connected to the following clamps with any polarity: 1 / 2 = sensor for the upper store temperature 3 / 4 = sensor for the lower store temperature The mains connection is at the clamps: 19 = neutral wire N 20 = conductor L 12 = earthing clip Indication: The medium contact M (15) and the conductor L (18) are bridged in delivery condition. After removing the bridge the change-over contact (RMA) becomes a potential-free relay. 5

2.3 example of use TLR2 Temp. Sensor Pt1000 S1 S2 1 2 3 4 PRG T4A 2 (1) A (220... 240) V~ R M A N L N L 12 13 14 15 16 17 18 19 20 S1 S2 3 Operation and functions 3.1 setting switch backwards 2 3 1 Set (selection / setting mode) forward R1 The controller is operated by 3 push-buttons below the display. The forward-button (1) serves the function of scrolling forward through the display menu or raising the set values. The backwards button(2) is serves the contrary. After the display channels there are the setting channels. In order to get to these channels, the forward button has to be pushed for 2 sec. after channel HO. If the display shows a set value, SEt is shown in the display. In this case the setting mode can be changed if the set-button (3) is pushed. chose channel with button 1 and 2 press button 3 quickly, display SEt flashes set the value with buttons 1 and 2 press button 3 quickly, display permanently shows SEt again, the setted value is memorised 3.2 controlparameter and display channels SU Upper Store temperature display channel of the current upper store temperature SL Lower Store temperature display channel of the current lower store temperature HO Hours of Operation display channel of the operation hours TO Temperature On setting channel switch-on temperature TF Temperature off setting channel switch-off temperature MM Manual Mode setting channel manuel mode PG ProGramm display channel programme number VN Version Number Anzeigekanal Versionsnummer 3.3 display channel SU SU shown the current upper store tempertaure 3.4 display channel SL SL shows the current lower store temperature 3.5 display channel HO HO shows the operation hours if the controller 3.6 display channel PG PG shows the programme number of the controller 3.7 display channel VN VN shows the version-number of the controller software 6

3. 8 setting channel TO TO:switch-on temperature setting range 20,0... 95,0 C in 0,5 steps factory setting 40,0 C When the upper store temperature SU falls below the setted value TO, the controller switches on the relay/pump and loads the store. The display shows and the status- LED glows green. 3.9 setting channel TF TF: switch-off temperature setting range 20,0... 95,0 C in 0,5 steps factory setting 45,0 C While the controller charges the store the lower store SL rises. When this temperature exceeds the value setted in TF, the relay/pump is switched-off and the loading of the store stops. The symbol disappears from the display and the status-led glows red. In order to avoid wrong settings the values TO and TF are blocked against each other. 3.10 setting channel MM MM: switch-off temperature setting range 0, 1, 2 factory setting 2 (Auto) manual operation 0 = on 1 = off 2= Auto Here you can chose between automatic and manual operation. In the manual operation mode the charging of the store can be started and stopped manually. For permanently deactivated store charge chose 0, for permanently activated store charging chose 1. If the controller is to charge the store automatically chose 2. 3.11 status-led blinking codes 4. Initiation constantly green: constantly red: flashing green/red: relay/pump switched on relay/pump switched off initialisation defective sensor manual operation First switch on the power supply. The controller initialises while the operation control lamp flashes green and red. After finishing the initialisation the controller is in automatic operation mode which ensures by the factory settings an optimum degree of efficiency for most systems. In case that the individual systems require an adaptation to the controller parameters they can be changed with the corresponding set values (see 3.2). 7

5. tips for fault location TLR2 Temp. Sensor Pt1000 S1 S2 1 2 3 4 Attention! Ensure separation from power supply before opening the housing PRG fuse T4A T4A 2 (1) A (220... 240) V~ R M A N L N L 12 13 14 15 16 17 18 19 20 PLease check the following if the controller does not work properly: 1. power supply In case that the operation control lamp is lapsed please check the power supply of the controller. The controller is protected with 1 fuse T4A. You can exchange it after removing the blind (spare fuse is in the accessory bag). 2. defecctive sensor In case that a system fault is caused by a defective sensor the operation control lamp flashes red/green and the symbol is shown in the display. A corresponding error code is shown in the display for the sensors in question. short-circuit: wire breakage: a short-circuit of the sensorcable with declaration of the affected sensor is shown in the display with the error code -888.8. Interruption of the sensor cable with declaration if the affected sensor is shown in the display with the error code 888.8. Pinched off Pt1000-temperature sensors can be checked with a resitance measuring device and have the resitance values shown in the table on the left. resistance values of the Pt1000-sensors Your specialist dealer: Note The design and the specification can be changed without any prior notice. The pictures can slightly differ from the production model. 8