MACHINERY SAFETY SURVEY RESULTS: Safety Interlocks and Used Equipment

Similar documents
Achieving Required Safety Levels Using a Pneumatic Safety Exhaust Valve

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

Modern Safety Systems and Advanced Fluid Power Solutions

Hydro Plant Risk Assessment Guide

ABB JOKAB SAFETY Protecting your valuable personnel and your company bottom line

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

Selecting & Integrating Safety Exhaust Valves White Paper

Reliable Temperature Compensation is Critical to CNG Vehicle Safety

Ex. 1-1 Nacelle Familiarization and Safety Discussion

Safety Working with LV Drives

ABB JOKAB SAFETY Products. Food and beverage industries Machine safeguarding solutions

Electrical Safety. Recognizing & Controlling Hazards

Session Four Applying functional safety to machine interlock guards

Electrical Safety. Introduction

NHP SAFETY REFERENCE GUIDE

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

Battery Technology for Data Centers and Network Rooms: Site Planning

Straight Talk. About the Smart Grid. Introduction

This specification describes the minimum requirements for a hoist maintenance safeguard (HMS) system for mine hoists.

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks

HIGH VOLTAGE vs. LOW VOLTAGE: POTENTIAL IN MILITARY SYSTEMS

SOFT TOUCH A NEW STANDARD FUNCTION FOR UNITROL SOLUTION

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

E-Mobility Trainings. Handling electric drives safely. TÜV SÜD Akademie GmbH

Selective Coordination Requirements

CONTROLLER DIAGNOSTIC GUIDE

29 CFR 1910, Subpart O

Hinge Wing Safety Interlock Switches

NORTH AMERICAN STANDARDS FOR LOW-VOLTAGE FUSES

Hours of Service (HOS)

Chapter 4 Utility Systems Electrical

Slide-locks Enforcement Policy, Inspection Procedures and Performance Guidance Criteria

Brochure. Arc Guard System TVOC-2 A protection device for reliable safety

CONTACT: Rasto Brezny Executive Director Manufacturers of Emission Controls Association 2200 Wilson Boulevard Suite 310 Arlington, VA Tel.

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

4-Day Power System Analysis, Coordination, System Studies

Investigation into UK socket-outlets incorporating USB charging points

TEK Brief July Is there a difference in installation requirements between communications cables with and without the LP designation?

Safety Exhaust Valve Integration Guide

Revised proposal to amend UN Global Technical Regulation No. 3 (Motorcycle brake systems) I. Statement of technical rationale and justification

United Stales COMDPTPUB P Coast Guard NVIC Mar 191

Autonomously Controlled Front Loader Senior Project Proposal

ECET Distribution System Protection. Overcurrent Protection

STANDARD REVIEW PLAN

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

Arc-Flash Mitigation Technologies. Dennis Balickie

Dealing with customer concerns related to electronic throttle bodies By: Bernie Thompson

SWITCHGEAR OPERATING PERSONNEL SAFETY UPGRADE SOLUTIONS FOR AGED INSTALLED BASE

AUTOMATIC MOLD RELEASE SPRAY MACHINE

Permit Type: Extended Drivers Hours of Service (Provincial)

Design Standards NEMA

Automated Control Electronics (ACE ) System Operation and Diagnostics

PREVOST AIR SYSTEMS WHAT THEY DO AND HOW THEY DO IT

UNI EN ISO EN

Japanese version of Connect & Manage for expanded introduction of renewable energies

DTC P0A04 - Open Wiring Fault

Political Forum. ClassNK s perspective on regulatory developments Low sulphur fuels & Ship digitalization

Exercise 1-1. Lockout/Tagout Procedure EXERCISE OBJECTIVE DISCUSSION. Become familiar with the Industrial Controls Training System.

CETOP POSITION PAPER PP 07

Electrical Safety For Everyone. Leader s Guide

MMP Investigation of Arthur Kill 2 and 3

Save-the-date: Workshop on batteries for electric mobility

Fleet Safety Initiative Status Summary

June Safety Measurement System Changes

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Vehicle Branding and Continuous Registration of Vehicles in Ontario for Licensed Limousines

Industrial Maintenance Technology Student Learning Outcomes

A REPORT ON THE STATISTICAL CHARACTERISTICS of the Highlands Ability Battery CD

2000 Cooper Bussmann, Inc. Page 1 of 9 10/04/00

Beyond Standard. Dynamic Wheel Endurance Tester. Caster Concepts, Inc. Introduction: General Capabilities: Written By: Dr.

What you Need to Know About Safety Exhaust Valves White Paper

Sense7-series Non-contact coded safety switch

Backfeed, Safety, and Work Practices

Sample Geographic Information System (GIS) Staffing and Response Time Report Virtual County Fire Department GIS Analysis

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood

To Our Business Partners

WELMEC European cooperation in legal metrology

Southern California Edison Rule 21 Storage Charging Interconnection Load Process Guide. Version 1.1

Q&A FOR Webinar on Electrical Basics & Boiler Wiring

Selective Coordination Enforcement:

Our Approach to Automated Driving System Safety. February 2019

NHP SAFETY REFERENCE GUIDE

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

S T A N D A R D. Copyright American Society of Agricultural and Biological Engineers. All rights reserved.

AUTOMATION AND CONTROL TRADE 19 TAR SANDS

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

ECET 211 Electric Machines & Controls Lecture 1-3 (Part 2) Electrical Safety in the Workplace Electrical Safety in the Workplace

IAE-101: Electrical Fundamentals for Non-Electrical Personnel

Automated Seat Belt Switch Defect Detector

Power Sliding Door (PSD) Diagnostic Approach. Fixing Intermittent Malfunctions. Power Sliding Door (PSD) Diagnostic Information

APPLICATION GUIDE. ACH580 Managing total cost of ownership of HVAC systems

FACT SHEET Standard: Electrical Safety

SUMMARY OF THE IMPACT ASSESSMENT

Unitil Energy Demand Response Demonstration Project Proposal October 12, 2016

S T A N D A R D. ASAE S FEB04 Front and Rear Power Take-Off for Agricultural Tractors

Service Manual. For the SCV2832E, SCV2426, Automatic Scrubbers For: Training Troubleshooting

Transcription:

MACHINERY SAFETY SURVEY RESULTS: Safety Interlocks and Used Equipment BY: Gary Hutter, P.E., Ph.D., C.S.P. AS PUBLISHED IN MARCH 2015 EDITION OF OHS MAGAZINE INTRODUCTION In the Fall of 2013, The National Safety Council s AMPS Committee, with the assistance of the National Safety Council (NSC), distributed a survey to over 3000 safety professionals concerning some issues of machine safety, safety interlocks, and used equipment safety. There were 111 respondents to the computer-based survey who were all identified by the National Safety Council s data base and by the individual respondents as being responsible for some aspect of industrial safety. Below is a summary of the results and a short discussion of these findings. The survey was short in nature, consisting of 11 questions which typically requested yes/ no responses, frequencies of certain safety activities, and estimates of accident-related events. There also was an opportunity for comments concerning the issues in the survey. This author thanks all of those who participated. Questions concerning machine safety, safety interlocks, and used equipment safety included the issues of: the testing and/or exercising of safety interlocks, manufacturer s directions on the frequency of testing and/or exercising safety interlocks, the need for testing of safety interlocks on used equipment, the implementation of alternative means over more traditional lockout/tagout procedures, the expectation that used equipment would have all the necessary safety equipment, and the failure of an interlock causing and/or contributing to an injury. GENERAL OVERVIEW OF RESULTS 1) Over 95% of respondents indicated their facilities utilized more than 31 safety interlocks on their machinery. 2) Eighty (80) or 72% of the respondents indicated that all safety interlocks got exercised/ tested every time a machine is placed into production, and 31 or 28% indicated that safety interlocks do not get exercised/ tested when machines are placed into production.

3) When asked on the frequency of safety interlocks being exercised/ tested per shift, about 52% indicated that occurred less than once per shift, about 39% indicated once per shift, and 9% indicated more often than once per shift. 4) Over 77% indicated that the machine provider did not provide a frequency on which to test safety interlocks. 5) When asked if a safety interlock might be used in the lockout/tagout activity, 17% indicated they would use an interlock in lockout/tagout. 6) Of the 111 respondents, 12 (~11%) indicated they knew of a safety interlock failure causing an injury. 7) When queried on the purchase of used equipment, it was almost unanimous that they would expect that safety devices on the used equipment that they acquired would be checked by their staff. 8) In addition, on used equipment, 97% of respondents indicated that they would not assume the reseller of the used equipment provided all the necessary safety features. DEF: Safety Interlock a device or means that places a machine or machine component into a zero, or substantially reduce, danger-mode upon intent to access; or a device or means that will actively prevent access to a hazard upon intended access. (Example: an interlocked clothes dryer door, that upon opening will quickly stop high speed rotation of the drum; or a clothes dryer door that will not allow intended access during high speed mode of operation.) 1 DISCUSSION On The Issue of Safety Interlock Testing The concept of interlocking for safety can be traced back several decades with perhaps electrical fuses and shear pins on power transmission shafts being two of the earliest wide spread applications of some form of safety interlock. While these two early forms of interlocks did not necessarily prevent injuries, they may have mitigated some injuries, and primarily were directed at preventing damage to equipment. Subsequent safety interlocks were more directed at reducing injuries by preventing behaviors that might cause an injury, or by placing a machine in a safe status if inappropriate behaviors occur. Properly designed pull back devices on mechanical power presses prevented the bad behavior of reaching into a cycling machine; properly designed two hand control would stop a part revolution clutch, making it safer if the operator detected a possible reach in situation. Of course pull back devices and two hand controls that were mis-adjusted and/or mis-positioned would not provide a consistent level of safety, hence the need to regularly examine their performance. 1 ANSI/SPI B151.21-2003 Defines an interlock as An arrangement whereby the status of one control or mechanism allows or prevents the operation of another. ANSI B11.19 for Machine Tools 1990, uses similar language.

More effective and modern safety interlocks generally were being patented in the 1950s, and often used limit-switches or other linkages to detect the status of a guard, machine component, or machine operation to perform the safety interlock function. These mechanical elements required proper alignment, non-jamming features, and return devices (e.g., springs, gravity, counterweights ) as basic elements of their design. To remain functional, their movements and performance needed to be verified in case a spring broke, or due to something jammed preventing gravity from resetting the interlock. Verification of the performance of safety interlocks did not guarantee future performance, but provided an opportunity to correct malfunctioning safety mechanisms, potentially before an accident. In the 1960 s and 70 s the patent history indicates that there was a marked increase in non-mechanical, non limit-switch based interlocks, often in the forms of light curtains, proximity detectors, or other type of presence/motion detectors (invisible detection means). These devices may not have had the same mechanical switches, alignment, and/or jamming considerations of the prior generation of mechanically activated switching mechanisms of earlier designs, but they too require some sort of functional testing. For example, many providers of light curtains specify intervals for functional testing their performance and coverage. Rockford Systems (a provider of safety hardware and training) publishes a check list for light curtain installations that states: Light curtains should be function-tested at every set up, operator and shift change, as well as every time after maintenance is performed. 2 To perform some testing of interlocks (e.g. during removal for electrical interlock testing), there may be a need to bypass the interlock mechanism or to perform some invasive action (e.g. reach beyond a guarded area). A functional evaluation for the earlier limit-switch interlock configurations and/or for the newer invisible detection means, often required actually simulating behaviors that are hazardous; that is, simulating reaching into a moving machine, opening a hinged guard when the machine is on, or functioning on/off switches at what could be inappropriate times. Other interlocks, like those that do not allow a machine to restart by itself after a power outage and circuit reset, may be more difficult to simulate, but still may have required some orchestrated performance testing. Since all of these safety interlocks still required some surveillance to determine their functionality, it was often deemed useful to check these interlocks by exercising them and/or testing them on some timebased frequency. For example, some manufacturers of commercial lawn, yard, and garden equipment provided some guidance on the frequency of testing of their machine interlocks. They typically operate in dusty, wet, and high utility-rate environments which can frustrate the longevity of such an interlock. A third wave of safety interlocks, that are reportedly self-checking, are documented in the patent literature generally starting around the mid-1980s and into the 1990s. These schemes may use 2 Rockford Systems, Inc., www.rockfordsystems.com/online/training/lightcurtain.cfm, 2/2014

redundant electronic circuits 3, movable safety interlock mounting elements to simulate operation without human involvement 4, and/or mechanical redundancy and hardware 5. There has been some criticism 6 of the reliance on these attempts of self-checking as manifested on interlocks in the form of redundancies, interlock bypasses, and/or negative vs positive failure mode monitoring 7. Regardless of the frequency of exercising and/or testing of safety interlocks, most of the subsequent results can only monitor past performance, and often have little ability to determine future performance of a particular safety interlock. In many ways it is like the test button on a smoke alarm, it tells you the horn and battery are functioning today and most likely yesterday, but does not tell you if the battery will be good at the end of the week. Various codes and standards include safety interlock criteria. American National Standards Institute (ANSI) standards and National Electrical Code (NEC /NFPA 79) for industrial machinery generally have not mandated a specific frequency for interlock exercising and/or testing, but in a liberal reading of ANSI ASSE Z244.1-2003 (R2008) 8, it does address self-checking or monitoring to ensure the integrity and performance of control circuits (e.g., interlocks). Medium Risk Potential Any exposure to serious injury. A dual channel circuit of industrial rated components that is self-checking or monitored through the use of a safety relay or safety PLC s to ensure integrity and performance of the control circuit. These systems typically have redundant interlock switch safety contacts, redundant isolation through positively guided electro-mechanical relays and are monitored or self-checking (pg. 26, para 5.4.3.2) In ANSI /SPI B151.21 2003 there is added detail about the equipment self-monitoring interlocks: A monitoring device shall be provided to verify the operation of the safety interlock(s). When improper operation is detected, the cycle shall be inhibited and an alarm shall be activated. This self-detection and self-stopping concept is repeated for electrical, hydraulic, pneumatic, and mechanical safety interlocks and devices. More recent International Standards Organization (ISO) standards and criteria have begun to more specifically address these issues of testing equipment-mounted safety interlocks. In EN ISO 13849-1 (2009) this issues of testing interlocks and other safety components/systems is addressed in various 3 U.S. Patent, Keese, 1/25/94, Self-checking Interlock Control System 5,281,857 4 Foreign Patent, Barnett, 7/5/2000 Remote and Proximal Guard and Interlock Testing Mechanism, EP 1015862 A2 5 U.S. Patent,, Kneip, 7/5/83, Self-checking Safety Mat, 4,392,176 6 Safety Interlocks- The Dark Side, F. Hall, Safety Brief, ISSN 1041-9489, June 1992, v7, No. 3 7 e.g., Negative Mode monitoring senses guard is closed and allows machine to operate; Positive Mode monitoring senses the guard is not closed and that prevents machine from operating. 8 Note this standard is written for the control of hazardous energy

forms including the concept of Mean Time To Failure and Mean Time Between Failures. In the Rockford Automation summary of that standard, they state: Designated Architecture Category 2 must use basic safety principles {see index of EN ISO 13829-2}. There must also be diagnostic monitoring via a functional test of the system or subsystems. This must occur at startup and then periodically (underlining added for emphasis) with a frequency that equates to at least one hundred tests to every demand on the safety function. 9 This standard language leaves the frequency of testing somewhat poorly defined and this was confirmed through contact with one of the major interlock suppliers who referenced ISO 13489, section 4. In that standard for example, they discuss a Category 2 interlock architecture, para 4.1.3, wherein: The periodic test interval is depending on the application. The checking interval can be established or based on the operating cycle or the machine cycle. It is important that the interval is suitable for [the] application. The checking interval needs to be evaluated/determined during the risk assessment for the application. For the above considerations, interlocks should be exercised and/or checked (monitored) for functionality. This may be due to possible mechanical, hydraulic, pneumatic, and/or electrical reasons. There appears to be a strong acknowledgement/ codification for the need for periodic monitoring, but it also appears that there is some latitude as to the exact frequency when using equipment that preceded recent applicable safety standards. On The Issue of Use of Safety Interlocks for Compliance with Control of Hazardous Energy (LOTO) The concept of control of hazardous energy focuses on the elimination or control of hazards and hazardous energy for maintenance and certain servicing operations. ANSI published standards on that issue prior to 1980, and OSHA codified that criteria in the 1980 and early 1990s in at least two portions of their standards; OSHA 29CFR 1910 subpart S Electrical 29CFR 1910.333., and in 29CFR 1910.147 The Control of Hazardous Energy. While the survey resulted in a rate of 17 out of 100 respondents indicating their approval of using an interlock for the control of hazardous energy under LOTO conditions, this is not the current policy of OSHA. The published OSHA criteria is : 29CFR 1910.333(b)(2)(ii)(B) 9 Safety Performance Levels, EN ISO 13849-1, Rockwell Automation

The circuits and equipment to be worked on shall be disconnected from all electric energy sources. Control circuit devices, such as push buttons, selector switches, and interlocks, may not be used as the sole means for de-energizing circuits or equipment. Interlocks for electric equipment may not be used as a substitute for lockout and tagging procedures. This admonition is repeated in other OSHA publications including Safeguarding Equipment and Protecting Employees from Amputation, OSHA 3170-02R, 2007: Interlock control circuitry may not be used for all maintenance and servicing work 10 and 29CFR1910.333(b)(2()ii)(B) Interlocks for electrical equipment may not be used as a substitute for lockout and tagout procedures. While one might theoretically argue that if an interlock is good enough for safe assess during operations, why should it not be sufficient for other activities. There are several reasons. One rational is contained in the NFPA 79 standard and is based on the concept that when an interlock may neutralize electrical powered components from movement (e.g., a motor will not be able to run), there is still a possibility of electrocution if the electrical power itself is not eliminated. 11 So, in general, following the traditional OSHA lockout and tagout procedures would not allow reliance on interlocks for worker safety. On The Issue of Use of the Purchase and Reinstallation of Used Industrial Production Equipment The terminology Used Industrial Production Equipment may have multiple connotations to different user groups. When we as non-industrial equipment purchasers go and buy a used car from a used car dealership, we generally expect that it is in reasonably good shape from a safety perspective. This does not mean that if we purchase a 1964 car we expect it to have seatbelts (pre-mandatory seatbelt requirement), or that the purchase of all 2012 cars will give us the protection of airbags all around. But in either case, it would seem reasonable that the brakes have been tested, what airbags are there work, and the seatbelts are compliant. If we buy a used mechanical item from a garage sale we may have much lower expectations. In an industrial setting there are sellers of used equipment that advertise and warranty that the used equipment operates, and /or that the safety components function as designed. Typically they do not perform their own independent safety analysis, their own detailed destructive testing, or risk assessments. Often these sellers do not know of the past service life or intended service application of the used hardware forcing them, to some extent, to rely on the integrity of the original design, and the care of the new owner. 10 Table 1 information on interlocks. 11 Safety Bulletin, Primary vs Secondary Protection: Why Interlocks and Not an Acceptable Alternative to Lockout, W. Switalski, Triodyne Inc., 9/2000

Other sellers of used equipment may sell equipment in an as is condition. That is the equipment was more of a salvaged item, perhaps to be used for spare parts or significant modification and upgrading by the purchaser. While these distinctions were not defined in the original questionnaire, it is apparent that those responding generally knew that used industrial production equipment may not have all the safety whistles and bells, and therefore responded as they did in regards to checking and evaluating safety items on this type of used equipment.