Model A9GT-70LTTBW Back Light

Similar documents
A9GT-50WSTAND. Thank you for buying the MELSEC-GOT Series

A9GT-50WRS2/A9GT-50WRS4 type Serial Communication Board

Channel Isolated Thermocouple Input Module

MELSEC-Q Series. Comprehensive, risk-free upgrade solutions

MELSEC-Q Series. Comprehensive, risk-free upgrade solutions

Q Series Large Type Base Unit/Blank Cover (AnS Series Size)

Insulation Displacement Connector for MELSEC-Q Series 32-Point I/O Module

MELSECASeries. A1S68AD Analog-Digital Conversion Module. Programmable Logic Controller. User's Manual (Hardware) MITSUBISHI ELECTRIC

Polígono Indutrial O Rebullón s/n Mos - España -

Better Performance For Radio Communication Network

Installation Manual. YASKAWA AC Drive Option Back-up Capacitor Unit for Momentary Power Loss. Type: P0010, P0020

GRIPPER CHAIN. For form, fill, and vacuum seal wrapping applications. Lower maintenance costs Increased uptime Increased productivity

Bearings for the Cement and Ready-Mix Concrete Industries

YASKAWA AC Drive-V1000

PARALLEL PROCESSING UPS E33A

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

High Performance Vector Control Drive Manual Supplement

Spherical Roller Bearings

Max. flow capacity of 5,000 L/min and max. discharge head of 98m. The world s largest class fluoroplastic magnetic drive pump.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

YASKAWA AC DRIVES. Application Solution. Extruder. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000

You ll find many Tsubaki products being

Extended Line-up. CAM CLUTCH BR-HT SERIES One-Way clutch

YASKAWA AC DRIVES. Application Solution. Injection Molding Machine. YASKAWA AC Drive GA700. YASKAWA Matrix Converter U1000

Tsubaki Power and Performance. For the Medical Equipment Industry

Iwaki Electromagnetic Metering Pump EWN-R (Chlorine Dioxide type)

MTC. Mold Temperature Control. Consilience Technology

Guide Ball Bushing NEW

Magnetic drive pumps A worldwide best-seller, our high-quality compact magnetic drive pumps

IWAKI Magnet Gear Pump MDG-M4 Instruction Manual

creora commitment to Excellence in personal hygiene

IFC07 E-03. USB Connectors HDMI Connectors DisplayPort Connectors

MELSEC-L/Q Series. Comprehensive, risk-free upgrade solutions


Information Technology and Economic Development: An Introduction to the Research Issues

Magnetic drive pumps. A worldwide best-seller, our high-quality compact magnetic drive pumps GFRPP. Magnetic drive pumps. series.

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

JHS Series Spherical Roller Bearings

Main material GFRPP IWAKI MAGNETIC DRIVE PUMPS

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

Airetool. Gas Line Cleaners Range: 3/4 (19.05mm) to 1-1/2 (38.10mm) Operating & Service Manual PL EN 10/01/2015

Parts Manual PL EN 05/19/ L4321 Router. For additional product information visit our website at

Instruction Sheet. Modular Air Pumps IMPORTANT RECEIVING INSTRUCTIONS DESCRIPTION

SMX-F. Self-priming magnetic drive pumps. Chemically resistant self-priming magnetic drive pumps which can tolerate abnormal operation CFRETFE

REFRIGERANT. Technical Information. Transport Properties of. DuPont Opteon yf. Engineering (I/P) Units

GENERAL GAS INSTALLATION LABORATORY SOLUTIONS

Infographics on Electromobility (January 2019)

Drive systems & electrical energy production for construction, local government structures, large infrastructure and industrial projects

MDM. Magnetic drive pumps Magnetic drive process pump resistant to dry run damage. Magnetic drive pumps. series

ETS/ETV/ECS/ECV FP1 Series

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

Industrial IT for Papermaking. Paper Machine Drive PMC800 Basic Drive

Nidec and Fuji Electric sign a Memorandum of Understanding to create a Joint Venture for Industrial Compact Motors

TRANSISTORIZED INVERTER INSTRUCTION MANUAL HIGH-DUTY BRAKE RESISTOR FR-ABR(H)

IWAKI Magnet Gear Pump MDG-M4 (built-in type) Instruction Manual

ULTIMA Ni-Cd BATTERY: PEAK PERFORMANCE WITH ULTRA LOW MAINTENANCE

Thermal Coal Market Presentation to UNECE Ad Hoc Group of Experts on Coal in Sustainable Development December 7, 2004

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

One machine multiple applications.

DOUBLE OCTOMILL TM PRODUCT RANGE

4CKNYC[A2 A2 AKPFGZ GRU AXLE RAIL / 02

Industrial Sewing Machines Use the Industrial Internet of Things to Increase Quality and Boost Productivity

MEMS MICRO-ELECTRO-MECHANICAL SYSTEMS

Installation Instructions

RHR Type SPHERICAL ROLLER BEARINGS

PLASTIC WELDING. New! TRIAC AT. Intelligent and robust.

SC05 E-04. AC Inlets Power Supply Connectors

Touch Point Solutions for SELF SERVICE Equipment SECURE SELF SERVICE ACCESS SOLUTIONS

I-Force Ironless. ML18 Linear Motor. Introducing: The Newest (and Smallest) Member to the I-Force Ironless Linear Motor Family. Ironless Advantages

Platform Systems. applications

NSK Ball Screws. Compact FA Series. Compact ball screws offer quiet, high-speed operating performance. Two-week delivery is available on common sizes.

Parts Manual EN PL30-12R04 07/21/ R04 Series 0.1 HP Inline Pencil Grinder

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent JAPAN / U.S.A. / TAIWAN / EU / CHINA

15K Series Extented Mini Right Angle Drill Attachment

Low energy, high quality, high reliability

Filterpack FR-BFP2-(H)0.4K to (H)15K

INSTALLATION & OPERATING MANUAL FOR KIT 2KW~20KW

testing to perfection MultiTest-i Technical Datasheet

CRES. RoD Actuator. Low-cost and handy actuator Dustproof and waterproof design compliant with IP55 standard Compliant with the RoHS Directives

Type: CIMR-T 4A J Models: 400 V Class, Three-Phase Input: 22 to 110 kw

IWAKI MAGNETIC DRIVE PUMPS MDM. Patent & Pat.Pend. JAPAN / U.S.A. / EU / CHINA / TAIWAN

10LF and 12LF Series Right Angle Grinders

M O T O R V E H I C L E S T A T I S T l C S

Matrix Total Fluid Management System

Options for the Ball Screw QZ Lubricator Wiper Ring W

10N10 Series Inline Grinder

Agilent 4UHV Ion Pump Controller. For Ultra High Vacuum

Circular & Rectangular Multi-Pole Connectors MPC06

530 Power. Grounding. Line voltage. Caution. A proper earth ground is required for GC operations.

10N M6 Series Right Angle Grinder

PLASTIC WELDING. New! TRIAC AT. Intelligent and robust.

Nevro Lead Compatibility

Knorr-Bremse Z-300 Condition Based Maintenance. Applications For Retrofit to All Passenger Rail Vehicles

N60 Rotary Vane Pneumatic Motor

World Air Conditioner Demand by Region

S8JX-N/S8JX-G Series Replacement Brackets

ENHANCED PASSENGER SAFETY

c Technical Bulletin cascade corporation Applications for Bronze Bearings and Lower Hooks TB 296 May 2015 Lower Hooks Upper Bearings Lower Bearings

The first in the world!

Transcription:

Model A9GT-70LTTBW Back Light User s Manual Thank you for purchasing the MELSEC-GOT Series. To ensure correct use of this equipment, please carefully read this manual prior to use. MODEL A9GT-70LTT-BW-U MODEL CODE 1DM194 IB(NA)-0800281-A(0401)MEE Mitsubishi Graphics Operation Terminal

SAFETY PRECAUTIONS (Always read before starting use) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. The precautions given in this manual are concerned with this product. For the safety precautions of the programmable controller system, please read the CPU module user's manual. In this manual, the safety precautions are ranked as "DANGER" and "CAUTION". DANGER CAUTION Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury. Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage. Note that the CAUTION level may lead to a serious consequence according to the circumstances. Always follow the precautions of both levels because they are important to personal safety. Please save this manual to make it accessible when required and always forward it to the end user. [HANDING PRECAUTIONS] DANGER Before changing the backlight, always switch off the GOT power externally in all phases (when the GOT is connected to the bus, the PLC CPU power must also be switched off externally in all phases) and remove the GOT main unit from the enclosure. Not switching the power off in all phases may cause en electric shock. Not removing the unit from the enclosure can cause injury due to a drop. CAUTION While changing the backlight, do not touch the circuit boards and electronic parts of the GOT. Doing so can cause a failure or malfunction. When changing the backlight, always note the following. Wear gloves or fingerstalls before starting the replacement of the backlight. Not doing so can cause injury. Start changing the backlight more than 5 minutes after switching the GOT power off. Not doing so can cause a burn due to the heat of the backlight.

[DISPOSAL PRECAUTIONS] CAUTION When disposing, treat this product as industrial waste. Related Manuals The following manuals are available for this equipment. Detailed Manual Manual name A985GOT/A975GOT/A970GOT/A960GOT User s Manual (Available as option) Manual No. (Model code) SH-4005 (13JL70)

1. Overview This user s manual explains the model A9GT-70LTTBW backlight (Referred to as backlight, hereafter). 2. Preformance The table below lists the performance specifications of the back lights. Item Specifications Applicable models *1 A975GOT-TBA-B, A975GOT-TBD-B, A970GOT-TBA-B, A970GOT-TBD-B Kind Cold cathode tube back light Life 43,000 h *1: Indicates models of function version B (manufactured in January, 2004) or later. <Checking function version> GOT function version can be checked from the rating plate, which is situated on the backside of the GOT. GRAPHIC OPERATION TERMINAL MODEL A970GOT-TBA-B B IN 100-240VAC 50/60Hz POWER MAX 115VA DATE 0401 A P LISTED 80M1 IND. CONT. EQ. MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN BD992C091H01 Function version Production date Function version B is manufactured from January, 2004. BACKLIGHT A9GT-70LTTBW Back light model The applicable back light model is Rating plate described. <Back light description> For the purpose of quick confirmation, the model name is described on the back light. Back light model Back light

3. How to Change the Backlight for Liquid Crystal In GOT, back lights are incorporated for the indicator LCD. These back lights lose the luminance as they are used. Replace the back lights if the luminance lowers further than that affects the performance of the indicator screen. The back light replacement procedure is described below. 1) Turn off the GOT power supply. Remove the wire from the power terminal. Then remove the communications cable. 2) Loosen the metal fitting on GOT to remove GOT from the cabinet. 3) Use a screw driver and remove four fastening screws on the back of GOT.

Top part Bottom part 4) After removing the fastening screws, remove the indicator cover from GOT, while pressing two fastening hooks.

a nail -like b Lift the black nail-like part (black) towards the a direction, and pull it out towards the b direction. Remove the cable connector on the back lights from the indicator connector. 5) Show the front face of GOT, and remove the cable connector that is fitted to the upper one of the back lights from the indicator connector. 6) Pull out the upper one of the back lights from the indicator. 7) To install new back lights, follow the procedure opposite to that of removing. Similarly, follow the opposite procedure for installing the indicator. Make sure to securely install the indicator and apply a torque within the specified range to the fastening screws for GOT. 36 to 48N cm (3.2 to 4.2lb inch)

Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi; damages to products other than Mitsubishi products; and to other duties. For safe use This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life. Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi. This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system. Country/Region Sales office/tel U.S.A Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061 Tel : +1-847-478-2100 Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. AV. Paulista 1471, Conj. 308, Sao Paulo City, Sao Paulo State, Brazil Tel : +55-11-283-2423 Germany Mitsubishi Electric Europe B.V. German Gothaer Strasse 8 D-40880 Ratingen, GERMANY Tel : +49-2102-486-0 U.K Mitsubishi Electric Europe B.V. UK Travellers Lane, Hatfield, Herts., AL10 8XB,UK Tel : +44-1707-276100 Italy Mitsubishi Electric Europe B.V. Italian Centro Dir. Colleoni, Pal. Perseo-Ingr.2 Via Paracelso 12, 20041 Agrate B., Milano, Italy Tel : +39-039-6053344 Spain Mitsubishi Electric Europe B.V. Spanish Carretera de Rubi 76-80 08190 - Sant Cugat del Valles, Barcelona, Spain Tel : +34-93-565-3131 France Mitsubishi Electric Europe B.V. French 25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France TEL: +33-1-5568-5568 South Africa Circuit Breaker Industries LTD. Tripswitch Drive, Elandsfontein Gauteng, South Africa Tel : +27-11-928-2000 Country/Region Sales office/tel Hong Kong Ryoden Automation Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Tel : +852-2887-8870 China Ryoden Automation Shanghai Ltd. 3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China Tel : +86-21-6475-3228 Taiwan Setsuyo Enterprise Co., Ltd. 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan Tel : +886-2-2299-2499 Korea HAN NEUNG TECHNO CO.,LTD. 1F Dong Seo Game Channel Bldg., 660-11, Deungchon-dong Kangsec-ku, Seoul, Korea Tel : +82-2-3660-9552 Singapore Mitsubishi Electric Asia Pte, Ltd. 307 ALEXANDRA ROAD #05-01/02, MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943 Tel : +65-6473-2308 Thailand F. A. Tech Co.,Ltd. 898/28,29,30 S.V.City Building,Office Tower 2,Floor 17-18 Rama 3 Road, Bangkpongpang, Yannawa, Bangkok 10120 Tel : +66-2-682-6522 Indonesia P.T. Autoteknindo SUMBER MAKMUR Jl. Muara Karang Selatan Block A Utara No.1 Kav. No.11 Kawasan Industri/ Pergudangan Jakarta - Utara 14440 Tel : +62-21-663-0833 India Messung Systems Put,Ltd. Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,PUNE-411026 Tel : +91-20-712-2807 Australia Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia Tel : +61-2-9684-7777 HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission. Specifications subject to change without notice. Printed in Japan on recycled paper.