ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

Similar documents
TDSscan10M Pocket TDS Tester Instruction Manual

ECscan20 Pocket Conductivity Tester Instruction Manual

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

PHscan10S Pocket ph Tester Instruction Manual

PHscan30S Pocket ph Meter Instruction Manual

ORPscan20 Pocket ORP Tester Instruction Manual

Bante220 Portable ph Meter Instruction Manual

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

EC20 Pocket Conductivity Tester Instruction Manual

COM-100 EC / TDS / TEMPERATURE METER

TRACER. POCKETESTER ä ORP CODE 1742

EC1 Pocket Conductivity Tester Instruction Manual

PH60 Series Premium ph Testers

Salt 1 Pocket Salinity Tester Instruction Manual

PH20 Value ph Tester Instruction Manual

Tracer ORP PockeTester TM Code 1742

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

Large Display ph Pens , , Instruction Manual

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

SoilStik ph Meter PRODUCT MANUAL. Item # 2105

WalkLAB Digital Dissolved Oxygen meter HD9030

Care and use guide. Contents. page

Model P772 Conductivity Meter. User Manual

Sunleaves TDS Expert Plus

HI Portable Waterproof Skin ph Meter INSTRUCTION MANUAL

Instruction Manual. PHscan30 Pocket ph Tester

4&5 RANGE CONDUCTIVITY METERS Operation Instructions

THREE RANGE DS METERS Operation Instructions

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Instruction Manual Portamess 911 Cond

OPERATION MANUAL PEN TYPE. Model: 8690 DESIGN PATENTED: US D S

STARTER 2000 Bench ph Meter Instruction Manual

Care and use guide. Contents. page

Care and use guide Guía de uso y cuidado Guide d utilisation et d entretien.

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

Visit us at

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

OPERATING INSTRUCTIONS

ACCURACY RELIABILITY SIMPLICITY

HI Ethylene Glycol Refractometer INSTRUCTION MANUAL

DUAL RANGE DIALYSATE METER Operation Instructions User Manual for Models D-2

MODEL IQ150 ph Meter Getting Started TWO-POINT CALIBRATION--QUICK REFERENCE GUIDE

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

User Manual dpette+ Electronic Pipette 2016-ver.1

Agxcel GX12i Chemical Injection System

User Manual Pocket Pro, Pro + ph

Exterior Digital Load Scale 201-EDG-01(B) Installation and Operation Manual Please read carefully before installation

Model 2053 Conductivity Meter Instruction Manual

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

Visit us at

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

User s Manual. Model PH71 Personal ph Meter IM 12B03D01-01E. IM 12B03D01-01E 3rd Edition

Compact Scales. Software Revision V1.25 & above

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

Instruction Manual PORTABLE ph METER D-71

MALCOM Table-Top Digital Viscometer Model PC-1TL Series

Troubleshooting. CryoSmart 1 - CryoSmart 20

SSP-Series Portable Balances Operation Manual

1 CONDIMENT DISPENSING SYSTEMS MODELS MCD-1 & MCD-2

Centrifuge Operator / Service Manual

Cold Vapor Mercury Apparatus* Purpose Figure 1 Cold Vapor Mercury Apparatus Assembly Overview

Global Water Instrumentation, Inc.

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

operating manual DL7 101 DIGITAL THERMOMETER

MODEL 905V OPERATING INSTRUCTIONS

RAPID OIL TEST GAUGE

Wisdom Systems. SCR Urea/Adblue Transfer System. Operating Instructions. Outstanding Features. Chemical Transfer and Application Technology

OPERATING INSTRUCTION

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

Operation and Maintenance Instructions Manual BOOSTER. Volume amplifier

User s Manual Model PH10RP KCl Replenish-free ph Sensor

CONTACT WATERRA. WS-2 REELCASE WATER LEVEL TAPE

Single and 8-channel Electronic Pipettes. Operation Manual Version: 2.9

American Weigh Scales SG-300. User Manual. SG-300 (300g x 0.1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

Breath Alcohol Tester

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Operating Manual for. Dispenser. Read this manual thoroughly before operating the Labmax Bottle Top Dispenser!

OPERATING INSTRUCTION

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

American Weigh Scales LS-110. User Manual. LS-110 (110lb x 0.2lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 2.

Memory Foam Massaging Bath Pillow with Wireless Remote Control

Instruction Manual. ph Meter D-51

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Dawson DSM170 Multi-Function Moisture Meter User s Manual

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

User Manual Electronic Titrator

1. INTRODUCTION AND SYSTEM DESCRIPTION BLOCK DIAGRAM GENERAL INFORMATION GLOSSARY... 7

User s Manual. Model PH72 Personal ph/orp Meter IM 12B03D02-01E. IM 12B03D02-01E 3rd Edition

Intelligent Electronic Safe

PosiTest. Pull-Off Adhesion Tester. INSTRUCTION MANUAL v PosiTest AT-M (manual) PosiTest AT-A (automatic)

HIGH VOLTAGE PROVING UNIT

Care and use guide. Contents. page

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

WASH SYSTEM. Instructions for Use

Model 8026 Particle Generator

Transcription:

ECscan10H Pocket Conductivity Tester Instruction Manual BANTE INSTRUMENTS LIMITED

ECscan10H Pocket Conductivity Tester 1 Introduction Thank you for selecting the ECscan10H pocket conductivity tester. This manual provides a step-by-step guide to help you operate the meter, please carefully read the following instructions before use. Inserting the Batteries Take out the G13A button cell batteries from the packaging. Follow the steps below to insert batteries into the battery compartment. Remove the battery compartment lid. Insert the three batteries into the battery compartment, note polarity. Replace the battery compartment lid and turn clockwise until it is tight. Keypad ECscan10H pocket conductivity tester has a succinct membrane keypad, names and symbols describe the each function key controls. INDEX: KEY MEAS/HOLD CAL C FUNCTION Power the tester ON/OFF. Freezes the measured value on the display, press the key again to resume measuring. In the calibration mode, confirms the setting value or exits calibration mode. Press and hold the key to enter the calibration mode. Press the key again to increase the setting value. In the measurement mode, shows current temperature. In the calibration mode, decrease the setting value.

C ECscan10H Pocket Conductivity Tester 2 Prior to Use Remove the electrode protective cap from the tester. Soak the electrode for a few minutes in tap water to remove dirt and oil stains on the electrode. Power On/Off Press MEAS key to turn on the tester, the display shows measured value. Press and hold the MEAS key for 5 seconds, the tester will turn off. If you do not press any key for 8 minutes, the tester will automatically turn off to conserve energy. Calibration ECscan10H pocket conductivity tester allows 1 point calibration. To ensure accurate measurement, we recommend that calibrating the meter regularly. The tester acceptable calibration ranges from 10 to 18/cm. Ensure that you use fresh conductivity standard solution during the calibration. DO NOT reuse calibration solutions as it may be contaminated and affect the calibration and accuracy of measurement. 1. Rinse the conductivity electrode with distilled water, then rinse with a small amount of calibration solution. 2. Dip the electrode into the calibration solution (e.g., 12.88/cm), stir the tester gently. Make sure there are no air bubble trapped in the slot of the sensor. 3. Press and hold the CAL key, the tester enters the calibration mode. CAL Cal S 4. Press or key to set the calibration value. Cal Press or key once, the setting value will gradually increase or decrease. Press and hold the or key, the setting value will quickly increase or decrease.

C ECscan10H Pocket Conductivity Tester 3 5. Ensure the displayed value matches your calibration standard, press MEAS key to confirm. The calibration value will automatically flash 3 times, the tester returns to measurement mode. Calibration is completed. Meas Hold EXIT THE CALIBRATION: During the calibration process, if you want to exit calibration mode, DO NOT press MEAS key in the step 5. Press or key until the display shows ---, then press MEAS key to exit. Conductivity Measurement Rinse the conductivity electrode thoroughly with distilled water. Dip the electrode into the sample solution. Stir the tester gently. Wait for the reading to stabilize, record the measured value on the display. Temperature Measurement In the conductivity measurement mode, press o C key, the display shows current temperature value. Press o C key again, the tester returns to conductivity measurement mode. Hold Function During the measurement, press HOLD key, the tester will immediately freeze current displayed value, HOLD indicator appears on the display. Press the key again to release the measured reading, you can continue to take measurement. Meas Hold Electrode Care and Maintenance After each use, the electrode should be rinsed thoroughly in deionised water. If there is a build-up of solids inside the measurement area of the cell, these should be removed very carefully with a cotton bud soaked in solvent, taking care not to touch the metal parts of the inner cell.

ECscan10H Pocket Conductivity Tester 4 Electrode Replacement When the tester fails to calibrate or gives fluctuating readings for calibration standards, you need to replace the electrode module. 1. Twist the electrode collar counter clockwise, pull the old electrode module away from the tester. 2. Align the slot on the new electrode module, gently push the module into the tester. 3. Twist the electrode collar clockwise until it is tight. Installation is completed. Troubleshooting LCD DISPLAY CAUSE CORRECTIVE ACTION Electrode dried out Measured value is out of range Incorrect calibration solutions Setting value does not match calibration solution Electrode is broken Soak the conductivity electrode in tap water for 10 minutes Check the electrode whether clogged, dirty or broken Using the fresh conductivity standard solutions for calibration Reset the calibration value Replace the electrode module

ECscan10H Pocket Conductivity Tester 5 Specifications Model Range ECscan10H 0.1~19.99/cm Accuracy ± 1% F.S Calibration Points 1 point Calibration Solutions 12.88/cm Temperature Compensation 0~50 C Temperature Coefficient 2%/ C Cell Constant K=1 Normalization Temperature 25 C Hold Function Manual Power Off Manual or Automatic (8 minutes after last key pressed) Sensor Type Order Code: ECSCAN-C1-100K Operating Temperature 0~60 C, 32~140 F Power Requirements Dimensions Weight 3 1.5V "G13A" Batteries 185(L) 40(Dia.)mm 100g Addendum: How to prepare the conductivity standard solution 12.88/cm 1. Place 8 to 9 grams of AR potassium chloride in a 50mL beaker and dry in an oven for 3 to 5 hours at 105 C, then cool to room temperature in desiccator. 2. Accurately weigh out 7.45g of KCL, and dissolve in 1000mL de-ionised water. 3. Stir the solution until the reagent has thoroughly mixed. Preparation is completed.

Hazardous Substance Statement Bante Instruments Limited is committed to the reduction and eventual elimination of all hazardous substances in both the manufacturing process and finished products we supply. We have an active manufacturing and procurement program to minimize and eliminate the use of harmful heavy metals such as cadmium, lead, mercury and the like. New technologies and design parameters are also promoting these efforts and we expect to have little or no such materials in our product in the coming years. We welcome our customer suggestions on how to speed up these efforts. Warranty The warranty period for tester is one year from the date of shipment. Above warranty does not cover sensor and calibration solutions. Out of warranty products will be repaired on a charged basis. The warranty on your meter shall not apply to defects resulting from: Improper or inadequate maintenance by customer. Unauthorized modification or misuse. Operation outside of the environment specifications of the products. For more information, please contact the nearest authorized distributor. BANTE INSTRUMENTS LIMITED E-mail: banteinstruments@yahoo.com Phone: +8621-6404-1598 Website: www.bante-china.com The information in this document is subject to change without notice. Copyright Bante Instruments Limited, 2015. All rights reserved.