Master MPS kva kva 3:1 3:3 VFI TYPE

Similar documents
Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master Plus kva

Master Plus kva

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

UPS Multi Sentry 10-20kVA

set out in standard IEC EN ). Multi Sentry is designed and built using state-of-the-art technology and components.

Master DIALOG INDUSTRY RANGE

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Technical Data Sheets

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

Technical Data Sheets

SIRIUS Online UPS. data CeNTReS. TeleCoMMUNICATIoN devices. MedICAl devices. emergency devices. TRANSPoRTATIoN. Smart Energy Solutions

UPS Multi Power 1-28 x 42 kw up to 1MW

HAIRF UPS. X5 Series KVA

Technical Data Sheets

SR series. on-line

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

1.1 GENERAL CHARACTERISTICS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

TECHNICAL DATA SHEET KVA UPS Systemss

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

Technical Data Sheets

MKN-DSP SERIES - THREE PHASE

POWERTRONIX QUASAR 5-40 KVA

PowerValue 11/31 T kva

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheets

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

EFFEKTA Power Supplies

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Data Sheets

TLE Series UPS 400/500 kw With eboost Technology

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva

Industrial PFC UPS System

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

PowerWave 33 Efficient power protection for today s IT and process-related work environments

TLE Series UPS 160/200/225/250 kw with eboost Technology

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

» Sophisticated» Reliable» Intelligent

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

POWER kva

SENTINEL VA

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

60 to 160 kva.

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Green Power 2.0 MASTERYS GP

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

PowerScale TECHNICAL SPECIFICATIONS

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Three Phase UPS Systems Range: 10 to 500kVA

ConceptpowerTM Modular kVA

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

PowerScale kva Technical Specifications

Technical data sheets

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

TECHNICAL SPECIFICATION UQ33-PRO kva (3/3) UPS

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Via Somalia, Cormano (MI) - ITALY Ph Fax:

MASTERYS IP+ 10 to 80 kva

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Technical Specifications SAFEPOWER-EVO-HF 10/15/20/30/40 kva three-phase input/three-phase output

MGE TM Galaxy TM 7000

Onfiniti. 1 Phase UPS

Multi Sentry kva kva. 3: kva 1:1 3:3 VFI TYPE. Large power size selection 10, 12, 15, 20 kva Small footprint. Zero impact source

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Specification SENTINEL PRO

Technical Specifications SAFEPOWER-EVO-HF. 60/120 kva three-phase input/three-phase output

Transcription:

DATACENTER E-MEDICAL INDUSTRY TRANSPORT EMERGENCY VFI TYPE ONLINE Master MPS 3:1 3:3 10-100 kva 10- kva 4 SmartGrid ready f lywheel compatible Supercaps UPS Service 1st start HIGHLIGHTS Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity Extensive parallel configurations Total protection Master MPS series UPS provide maximum protection and power quality for mission critical loads, including data centres, industrial processes, telecommunications, security and electro-medical systems. Master MPS is an on-line double conversion UPS (VFI SS 111 - IEC EN 62040-3) with a transformer isolated inverter. The Master MPS range includes three-phase input and single-phase output versions from 10 to 100 kva, and three-phase input and output versions from 10 to kva. All versions are provided with a 6-pulse available on request for the 60 and 80 kva versions (provided as standard for MPT ), Easy source Master MPS makes supplying the UPS from generator sets and MT/BT transformers

loss in the system and coils, correcting the power factor and eliminating current harmonics created by the loads supplied by the UPS. start-up (power walk-in) and the option to reduce battery charging currents, allow for a reduction in the input current uptake. This means less demand on the source, which is particularly useful when the source is a generator set. Power continuity For years, Riello UPS has developed and supplied solutions for dealing with the that inevitably arise in critical applications. Detail of connection area system structures and critical levels. Riello UPS creates UPS systems that can tolerate a number of component or subsystem failures, while continuing to operate normally, providing power without interruption. This is achieved by careful design, installing redundant elements, eliminating common failure points, scheduling maintenance activities and controlling and supervising the system operating parameters and environment. The TEC service team is ready to provide guidance and advice on projects. Flexibility Master MPS is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for power capacitive loads such as blade servers, without any reduction in active power, from 0.9 leading to 0.8 lagging. With a broad range of accessories and architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing users. Using the Riello UPS Group Synchroniser (UGS) and Parallel Systems Joiner (PSJ), sophisticated inter group parallel and redundant systems can be achieved to provide the highest possible levels of resilience and availability. care system: maximum battery care battery care system consists of a series of functions designed to optimise battery management and achieve the best performance and operating life possible: Dual level charging regime to optimise recharge currents and reduce charge times Temperature compensation and deep discharge protection to reduce battery ageing and improve battery life Charge blocking system to reduce electrolyte consumption and lengthen the life of VRLA batteries tests to diagnose, in advance, any reduction in performance or problems with the batteries. battery technologies: vented open lead acid, VRLA AGM, Gel, NiCd, Flywheels, Supercaps and Lithium. Easy installation Master MPS requires a very small space for installation (only 0.64 m2 for a 200kVA system); in addition, front access allows for the servicing of all major components from the front panel, making side access unnecessary. In addition, front access allows servicing of all major components from the front panel, making side access unnecessary. Master MPS requires minimal space for access, utilising top-cabinet ventilation and front panel access. solutions The UPS can be adapted to meet the most monitoring. Advanced multi-platform communications for all operating systems and network environments: PowerShield3 monitoring and shutdown software included, with SNMP agent, for Windows operating systems 8, 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris, Linux, Novell and other Unix operating systems The UPS is provided with a cable for direct connection to a PC (Plug and Play) Double RS232 serial port Communications slot for network adapter installation; ESD contact (Emergency by remote emergency button Remote display panel with graphic display. Maximum reliability and availability Distributed or centralised parallel redundant (N+1) or power parallel system. Hot System Expansion (HSE): allows the addition of a further UPS into an existing existing UPS or transfer them to bypass mode. This guarantees maximum load protection, even during maintenance and system expansion. Maximum levels of availability, even in the event of an interruption to the parallel bus cable: the system is FAULT TOLERANT. It Normally the batteries are kept charged by UPS uses this energy source to power the consumers. Proper battery care is therefore critical to ensuring correct UPS operation under emergency conditions. The Riello UPS and continues powering the load without disruption, signalling an alarm condition. listed in this catalogue. Advanced communications Compatible with TeleNetGuard for remote parallel systems, according to the power

required by the load. N +1 redundancy is guaranteed, with every UPS working in parallel at the best load level possible to Options UPS Group Synchroniser (UGS) Allows two or more non-parallel UPS devices to remain synchronised even during mains power failure. The UGS also enables a Riello UPS to be synchronised with another power source power rating. Parallel Systems Joiner (PSJ) Allows two groups of UPS to be connected in parallel whilst operating, in the event of maintenance (with no interruption to the output), using a power coupling switch. Should one of the UPS in one of the parallel groups fail, it is automatically excluded. The PSJ connects the remaining UPS, to the other parallel group via an external bypass, in order to continue to guarantee load redundancy. PARALLEL CONFIGURATION OF UP TO 8 UPS UNITS WITH DISTRIBUTED BYPASS Parallel architecture to ensure redundancy of the power source. + Flexibility and modularity and no single point of failure. PARALLEL CONFIGURATION OF UP TO 8 UPS UNITS WITH COMMON BYPASS Parallel architecture to ensure redundancy of the power source, with autonomous bypass management. + Selectivity of downstream faults in bypass mode Bypass mains Bypass mains UPS1 UPS2 UPS3... UPS8 UPS1 UPS2 UPS3... UPS8 Common BY PASS Maintenance Bypass Cabinet Load Load DYNAMIC DUAL BUS CONFIGURATION Solution to ensure redundancy up to the distribution of the power supply to the loads and improved STS operation. + Downstream fault discrimination DUAL BUS SYSTEM CONFIGURATION Solution to ensure redundancy of the power supply even during maintenance. + High availability and redundancy System A Bypass 1 System B Bypass 2 System A Bypass 1 System B Bypass 2 UPS1A UPS2A UPS1B UPS2B UPS1A UPS2A UPS1B UPS2B UGS Sinchroniser PSJ Static Transfer SWITCH SWITCH Load 1 Load 3 Static Transfer SWITCH Load 2 Load 1 Load 2 Load 4

DIMENSIONS MPM/MPT 10 40 MPM/MPT 60 80 MPM/MPT 10HC 40HC MPM 100 MPT 100 200 MPM/MPT 60HC 80HC MPT 60D 80D MPT 60DHC 80DHC MPM 100HC MPT 100HC 200HC MPT D 555 825 1070 1070 4400 1000 th or 11 th harmonics D= Twelve-phase version OPTIONS SOFTWARE PowerShield 3 PowerNetGuard ACCESSORIES NETMAN 101 PLUS NETMAN 102 PLUS NETMAN 202 PLUS MULTICOM 301 MULTICOM 302 MULTICOM 351 MULTICOM 352 MULTICOM 401 MULTI I/O Interface kit AS400 MULTIPANEL RTG 100 56K Modem GSM Modem MBB 100 A PRODUCT ACCESSORIES Twelve-phase version (D) Filtering of 5 th and 11 th harmonics (HC) Isolation transformer Synchronisation device (UGS) Hot connection device (PSJ) Generator interface cabinets empty or for extended runtimes Top Cable Entry cabinets IP rating IP31/IP42 DETAILS RS232-REPO CONNECTORS DRY CONTACTS COMMUNICATIONS INTERFACE SLOT MPS (detail of front) SWIN SWBYP FAN FUSES SWMB SWOUT PARALLEL INTERFACE UGS INTERFACE MULTI I/O MODEM INTERFACE REMOTE ALARM MPT 200 open

BATTERY BOX MODELS BB 384-B1 BB 384-B2 / BB 384-B3 BB 384-B4 BB 396-L6 / BB 396-L7 BB 396-L8 / BB 396-L9 BB 480-V6 / BB 480-V7 BB 480-V8 / BB 480-V9 UPS MODELS MPT 10-60 MPT 10-80 MPT 100-200 / MPM 100 MPT Dimensions (mm) BB BB BB 555 860 860 CABINETS WITH TOP ACCESS FOR CABLES MODELS t Ce MPt 100-200 UPS MODELS MPT 100-200 / MPM 100 SINGLE-PHASE ISOLATION TRANSFORMERS MODELS t BX 10 M - BX 80 M t TBX 100 M UPS MODELS MPM 10-80 MPM 100 Dimensions (mm) Dimensions (mm) TCE 270 640 640 THREE-PHASE ISOLATION TRANSFORMERS MODELS TBX 10 T - TBX 80 T TBX 100 T - TBX 160 T TBX 200 T - TBX 250 T UPS MODELS MPT 10-80 MPT 100-160 MPT 200 Dimensions (mm) 640 640

MODELS MPM 10 BAt MPM 15 BAt MPM 20 BAt MPM 30 MPM 40 MPM 60 MPM 80 MPM 100 INPUT 380-400 - 415 Vac three-phase Voltage tolerance 400 V + 20% /- 25% 45-65 Hz Soft start 0-100% in 120 (selectable) Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Standard equipment provided Back Feed protection; separable bypass line BYPASS Nominal frequency 360-400-420 Vac three-phase + N OUTPUT Nominal power (kva) 10 15 20 30 40 60 80 100 Active power (kw) 9 13,5 18 27 36 54 72 90 Number of phases 1 220-230 - 240 Vac single-phase + N (selectable) Static stability ± 1% Dynamic stability ± 5% in 10 ms Voltage distortion < 1% with linear load / < 3% with non-linear load Crest factor 3:1 lpeack/lrms stability on battery 0.05% Overload 110% for 60 ; 125% for 10 ; 150% for 1 BATTERIES Type VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels Residual ripple voltage < 1% Temperature compensation -0.5 Vx C Typical charge current 0.2 x C10 INFO FOR INSTALLATION Weight without batteries (kg) 200 220 230 270 302 440 500 580 Dimensions (WxDxH) (mm) 555 x x x x Remote signals dry contacts Remote controls ESD and bypass Communications Double RS232 + dry contacts + 2 slots for communications interface Operating temperature 0 C/ +40 C Relative humidity <95% non-condensing Colour Dark grey RAL 7016 Noise level at 1 m 60 dba 62 dba IP rating IP20 up to 98% Standards Directives LV 2006/95/EC - 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2; Performance IEC EN 62040-3 x x with IEC 62040-3 Moving the UPS (Voltage Independent) VFI - SS - 111 transpallet BAt Also available with internal batteries

MODELS MPT 10 BAt MPT 15 BAt MPT 20 BAt MPt 30 MPt 40 MPT 60 MPT 80 INPUT 380-400 - 415 Vac three-phase Voltage tolerance 400 V + 20% /- 25% 45-65 Hz Soft start 0-100% in 120 (selectable) Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Standard equipment provided Back Feed protection; separable bypass line BYPASS Nominal frequency 360-400-420 Vac three-phase + N OUTPUT Nominal power (kva) 10 15 20 30 40 60 80 Active power (kw) 9 13,5 18 27 36 54 72 Number of phases 3 + N 380-400 - 415 Vac three-phase + N (selectable) Static stability ± 1% Dynamic stability ± 5% in 10 ms Voltage distortion < 1% with linear load / < 3% with non-linear load Crest factor 3:1 lpeack/lrms stability on battery 0.05% Overload 110% for 60 ; 125% for 10 ; 150% for 1 BATTERIES Type VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels Residual ripple voltage < 1% Temperature compensation -0.5 V/ C Typical charge current 0.2 x C10 INFO FOR INSTALLATION Weight without batteries (kg) 228 241 256 315 335 460 540 Dimensions (WxDxH) (mm) 555 x x x x Remote signals dry contacts Remote controls ESD and bypass Communications Double RS232 + dry contacts + 2 slots for communications interface Operating temperature 0 C / +40 C Relative humidity <95% non-condensing Colour Dark grey RAL 7016 Noise level at 1 m 60 dba 62 dba IP rating IP20 up to 98% Standards Directives LV 2006/95/EC - 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2; Performance IEC EN 62040-3 with IEC 62040-3 Moving the UPS (Voltage Independent) VFI - SS - 111 transpallet BAt Also available with internal batteries

MODELS MPT 100 MPT 120 MPT 160 MPT 200 MPT INPUT 380-400 - 415 Vac three-phase Voltage tolerance 400 V + 20% /- 25% 45-65 Hz Soft start 0-100% in 120 (selectable) Permitted frequency tolerance ± 2% (selectable from ± 1% to ± 5% from front panel) Standard equipment provided Back Feed protection; separable bypass line BYPASS Nominal frequency 360-400-420 Vac three-phase + N OUTPUT Nominal power (kva) 100 120 160 200 Active power (kw) 90 108 144 180 640 Number of phases 3 + N 380-400 - 415 Vac three-phase + N (selectable) Static stability ± 1% Dynamic stability ± 5% in 10 ms Voltage distortion < 1% with linear load / < 3% with non-linear load Crest factor 3:1 lpeack/lrms stability on battery 0.05% Overload 110% for 60 ; 125% for 10 ; 150% for 1 BATTERIES Type VRLA AGM / GEL; NiCd; Supercaps; Li-ion; Flywheels Residual ripple voltage < 1% Temperature compensation -0.5 V/ C Typical charge current 0.2 x C10 INFO FOR INSTALLATION Weight (kg) 600 610 690 790 5300 Dimensions (WxDxH) (mm) x x 4400 x 1000 x Remote signals dry contacts Remote controls ESD and bypass Communications Double RS232 + dry contacts + 2 slots for communications interface Operating temperature 0 C / +40 C Relative humidity <95% non-condensing Colour Dark grey RAL 7016 Noise level at 1 m 65 dba 68 dba 77 dba IP rating IP20 up to 98% Standards Directives LV 2006/95/EC - 2004/108/EC; Safety IEC EN 62040-1; EMC IEC EN 62040-2; Performance IEC EN 62040-3 with IEC 62040-3 Moving the UPS (Voltage Independent) VFI - SS - 111 transpallet