Gas Pressure Governors

Similar documents
VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

SKPx5... Actuators for Gas Valves. Building Technologies HVAC Products SKP15... SKP25... / SKL25 SKP55... SKP75...

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

VLF45... Hot Air Valves. Building Technologies Division

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners

Actuators for air dampers and control valves of oil burners

Actuators for Air and Gas Dampers

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

Actuators for Air and Gas Dampers

For air dampers and control valves of oil or gas burners

Proportional controlling element

Electromotoric Actuators

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

VGD Series VGDxx.xxxU Gas Valves for use with SKPxx.xxxU electro hydraulic actuators

SQN9... Damper Actuators. Building Technologies HVAC Products. SQN9..., front (covers removed) SQN9..., rear (covers fitted)

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

For air / gas dampers and control valves of oil or gas burners

Electronic Ignition Module

Actuators. Building Technologies Division

Actuators for Air and Gas Dampers

3 Edition Product brochure GB AGA

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Actuators for air and gas dampers

Actuators for small valves

Connection Accessories for small Burner Controls

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

Electronic Ignition Equipment

Air damper actuators

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01

Differential Pressure Switch QBM81-

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

Governor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

2-Port and 3-Port Zone Valves, PN16

Differential Pressure Sensors

Differential Pressure Switch QBM81-

Air damper actuators

Heating Cost Allocation Valve with local acquisition of the flow temperature

Pressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV

GDB..3..1A GLB..3..1A

Differential Pressure Sensors

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

Electromotoric Actuators

Modulating control valve PN16 with magnetic actuator

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

Modulating control valve PN16

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

SERIES 2000 GAS SAFETY SHUT OFF VALVE

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

2-Port and 3-Port Zone Valves, PN 16 / 20

Manually operated safety shut-off valve HSAV HSAV/5

822 NOVAMIX GAS FLOW RATE ADJUSTMENT AS A FUNCTION OF THE AIR FLOW GAS/AIR RATIO 1:1 DOUBLE AUTOMATIC SOLENOID SHUT-OFF VALVE

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

Modulating control valve PN16 with magnetic actuator

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Cable Temperature QAP... Sensor. Use

Modulating control valves with magnetic actuators, PN 16

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

ASZ... Potentiometers. Building Technologies Division. ASZxx.3x

SAV Electronic Valve Actuator

2-Port and 3-Port Zone Valves & Actuators, PN16

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Electromotoric Actuators. for zone valves VVI46.., VXI46.., VVS46.. and VXS46..

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Differential Pressure Sensors

Tightness control TC. Product brochure GB Edition 12.10

Actuators for Fire and Smoke Protection Dampers

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Actuators for Fire and Smoke Protection Dampers

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Old documentation - Only for your information! Product is not available any more!

SAX Electronic Valve Actuator

Electro- Hydraulic Actuator Gas Valves GH-5000

Modulating control valves with magnetic actuators, PN 16

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

PRESSURE REDUCING VALVE

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Condensation monitor

ONE STAGE GAS BURNERS RDBS SERIES

VE4000 & VE5000 SERIES

P600 Pressure Regulator

PRESSURE REDUCING CONTROL VALVE

Modulating Control Valve PN 16 with Magnetic Actuator

Actuators for Fire Protection Dampers

Electric actuators for small valves

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5

Transcription:

7 641 ISO 9001 SKP10... SKP20... SKP13... SKP23... VGG... VGF... VGH... Electrohydraulic Actuators SKP1... Gas Pressure Governors SKP2... Gas Valves VGG... VGF... VGH... On / off safety shut-off valves, 2-stage or with integrated constant or balanced gas pressure governor; for natural gas, town gas or liquefied petroleum gas in the low pressure range. Electrohydraulic actuators featuring delayed opening and rapid closing. The SKP1... / SKP2... / VG... and this Data Sheet are intended for use by OEMs which integrate the actuators and gas valves in their products! 23.01.2001 Landis & Staefa Division

Use The VG... gas valves with their electrohydraulic SKP... actuators are designed for gas families I, II, III and air. They are used primarily in gas-fired combustion plant. The valves open slowly and close rapidly. All types of VG... gas valves can be combined with the available types of actuators. The actuator is fitted to the valve body by means of the 4 screws contained in the terminal compartment. The square flange can be turned in steps of 90, thus providing 4 different mounting positions. The actuator can be fitted or replaced while the valve is under pressure. Sealing materials are not required. Actuator type SKP2... is equipped with an integrated precision gas pressure governor. This type of actuator with gas pressure governor not only reduces the length of the gas train, but usually also permits selection of a smaller valve size. For detailed information about valve sizing, refer to «Flow chart». The actuator is also available with limit and auxiliary changeover switches, e.g. for indicating the fully closed position or for stroke limitation in connection with 2-stage gas release, etc. The SKP20.130... operates as a balanced gas pressure governor and controls the gas pressure according to the pressure of the combustion air so that the gas / air ratio remains constant over the entire load range (shifting the setpoint by the static pressure of the combustion air). Therefore in contrast to conventional gas / air ratio control air volume changes due to mains pressure variations, soiled fan wheel, etc., have no impact on the quality of the combustion process. Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! Is not permitted to open, interfere with or modify the actuators and valves. Before performing any wiring changes in the connection area of the SKP1... / SKP2..., completely isolate the actuator from the mains supply Ensure protection against electric shock hazard by providing adequate protection for the connection terminals Only with SKP13.111B27 and SKP23.111B27: Prior to connecting auxiliary switch, pull out the plug Check wiring and all safety functions Fall or shock can adversely affect the safety functions. Such actuators and valves may not be put into operation even if they do not exhibit any damage Mounting notes The relevant national safety regulations must be complied with. Installation notes Installation work must be carried by qualified staff When using the SKP2... actuator with attached gas pressure governor, the gas pressure monitor for lack of gas must always be mounted upstream of the valve When using the auxiliary switch, the earth conductor of the connecting cable must be connected to the earth terminal in the housing Commissioning notes Commissioning and maintenance work must be carried out by qualified staff. 2/17

Service notes VGH... valves may only be overhauled by Landis & Staefa Repair Centers VGH... valves are supplied without strainer. They must be installed either with a gas filter upstream of the valve or an AGK... strainer (refer to «Accessories») on the valve s gas inlet side Disposal The unit contains electrical components, electronic components and hydraulic oil, it is not allowed throwing into household garbage. Pay attention to the local and actualize law. Mechanical design Actuator SKP1... The actuator s hydraulic drive system consists of a cylinder filled with oil and an electric oscillating pump with piston and relief valve. The relief valve is located in the bypass between the suction and pressure side of the pump. With the actuators of the B-series, it is a valve hydraulically actuated by the pump pressure; with the 2-stage actuators of the A-series, it is a normally open solenoid valve. The cylinder carries a seal which hydraulically separates the inlet from the outlet side of the pump, also serving as a guidance for the piston. The piston is also guided by a rod which is rigidly connected to it. This rod transfers the piston s travel directly to the valve stem. The rod is provided with a disk the position of which is visible through a window in the console (indication of stroke). Using a lever system, the disk also actuates - the auxiliary switch for indicating the fully closed position, or - other positions, as well as the limit changeover switches for positioning the lowand high-fire stroke with the two-stage actuators. The switching points of these switches are adjustable over the entire stroke. The adjusting screws are located in the terminal compartment. Basic design (Sectional view of SKP1... and VG... / VL...) SKP1... VG.../VL... pe 7641z32/1200 3/17

Actuator SKP2... with gas pressure governor The gas pressure governor consists of - working diaphragm - safety diaphragm - setpoint spring - lever system for actuating a ball valve located in the bypass between the suction and pressure side of the hydraulic system (refer to «Function»). The setpoint adjustment can be sealed. The impulse pipe connection is Rp¼. The housings of actuator and governor are made of die-cast aluminium and the seals are made of elastomer. Basic design (Sectional view of SKP2... and VG... / VL...) Luft / Air Rp 1/4 SKP2... > 4 mm VG.../VL... min. 5d pe d 7641z06/1200 4/17

Valves VGG... and VGF... These valves are normally closed one-way disk type valves. Their stem is guided on both sides of the disk, thus ensuring precise alignment of the stroke as well as tight shut-off. The closing force of the return spring is supported by the prevailing gas pressure. The valves are available with profiled or flat disks and with or without stroke limitation (refer to «Type summary»). An interchangeable strainer made of stainless steel protects seat and disk as well as downstream controls from dirt. Basic design of valves VGG... and VGF... 7641z33/0 Valves VGH... These valves are normally closed one-way high-flow type valves. The swing-type flap has no profile. The great closing force of the return spring is supported by the prevailing gas pressure. An AGA... strainer is available as an accessory item (refer to «Accessories»). The valves are supplied without strainer. Basic design of valves VGH... 7641z30/0399 Closed Open 5/17

Type summary SKP1... / SKP2... for use with VG... valves The complete gas shut-off assembly or pressure control section consists of actuator and valve. Actuators Mains voltage AC...110 V AC 220...240 V Single-stage opening and closing; without limit and auxiliary changeover switches Without pressure governor SKP10.110B17 SKP10.110B27 ot in the range SKP13.110B27 With pressure governor up SKP20.110B17 SKP20.110B27 to 22 mbar ot in the range SKP23.110B27 Balanced pressure governor ot in the range SKP20.130C27 Single-stage opening and closing; one auxiliary changeover switch Without pressure governor SKP10.111B17 SKP10.111B27 ot in the range SKP13.111B27 With pressure governor up SKP20.111B17 SKP20.111B27 to 22 mbar ot in the range SKP23.111B27 Balanced pressure governor ot in the range ot in the range 2-stage opening and closing; with 2 limit switches and one auxiliary changeover switch Without pressure governor SKP10.123B17 SKP10.123B27 With pressure governor up to 22 mbar ot in the range ot in the range Balanced pressure governor ot in the range ot in the range Accessories for gas pressure governor Setpoint springs - 15...120 mbar (yellow) AGA22 -...250 mbar (red) AGA23 Damping throttle (refer to «Charts») AGA25 Connecting cable (ot included in delivery, must be ordered as a separate item) AGA62.000A27 6/17

Valves The SKP1... / SKP2... are suited for use with the following types of valves: Type reference Medium Data Sheet VGG... / VGF... / VGH... atural gas 7641 families I, II, III VGD20... atural gas 7631 VGD40... families I, II, III VRF... / VRH... Biogas 7633 VLG... / VLF... Cold and hot air 7637 Perm. operating pressure in mbar umber of connections Type reference Flow rate With profile Without profile of air at Without Without Europe and Other p = 1 Test adjustable With adjustable adjustable With adjust- ominal size Valve body material Australia (to E) countries mbar / m³ / h point RP ¼ 5) Pilot gas G ¾ 6) stroke limitation stroke limitation 1) stroke limitation able stroke limitation 1) Replacement set part no. Internally threaded to ISO 7/1 ½ Die-cast Al 1200 1200 4.8 4 --- VGG10.154P VGG10.1541P 2) --- 4) --- 4) 4 679 1560 0 ¾ Die-cast Al 1200 1200 8.9 4 --- VGG10.204P VGG10.2041P 2) VGG10.204 VGG10.2041 2) 4 679 1492 0 1 Die-cast Al 1200 1200 13.3 4 --- VGG10.254P VGG10.2541P 2) VGG10.254 VGG10.2541 2) 4 679 1493 0 1 ½ Die-cast Al 600 600 32.3 4 --- VGG10.404P VGG10.4041P VGG10.404 VGG10.4041 4 679 1494 0 2 Die-cast Al 600 600 47.4 4 --- VGG10.504P VGG10.5041P VGG10.504 VGG10.5041 4 679 1495 0 3 Grauguss 600 600 85.4 2 2 VGG10.804P VGG10.8041P VGG10.804 VGG10.8041 4 679 1559 0 3) Flanged, P16, to ISO 7005 D40 Cast iron 600 600 32.3 4 --- VGF10.404P VGF10.4041P VGF10.404 VGF10.4041 4 679 1494 0 D50 Cast iron 600 600 47.4 4 --- VGF10.504P VGF10.5041P VGF10.504 VGF10.5041 4 679 1495 0 D65 Cast iron 600 600 74 2 2 VGF10.654P VGF10.6541P VGF10.654 VGF10.6541 4 679 1558 0 3) D80 Cast iron 600 600 85.4 2 2 VGF10.804P VGF10.8041P VGF10.804 VGF10.8041 4 679 1559 0 3) Disk type valves, high-flow, with swing-type flap. Great closing force. Without strainer, to DI, can only be used in plants with gas filter. These valves may only be overhauled by Landis & Staefa Repair Centers. D80 Cast iron 300 600 128.4 4 1 --- --- VGH10.18050 --- --- D Cast iron 300 400 199.5 4 1 --- --- VGH10.19050 --- --- D125 Cast iron 300 300 277.6 4 1 --- --- VGH10.19150 --- --- 1) ot for use with integrated gas pressure 3) Refer to notes «Replacement sets»! 6) On inlet side, VGG... and VGF...: one governor! 4) Only available with profile connection on each side 2) Flow rate 20 % lower 5) Equal share on inlet and outlet side 7/17

Accessories for valves Strainers for VGH... valves, with compression fitting, mesh size 1 mm for VGH10.18050 D80 AGA80 for VGH10.19050 D AGA90 for VGH10.19150 D125 AGA91 Replacement sets consisting of stem, disk, strainer, screws, washers and gaskets. For part nos., refer to «Type summary / Valves». o replacement sets are available for VGH... valves. All service replacements sets can also be used with the predecessor type, with the exception of: Type reference D / Dim. Part no. VGF10.1655... 65 4 679 9501 0 VGG10.1805 3 4 679 9502 0 VGF10.1805... 80 4 679 9502 0 When used with gas, the valves constitute part of the safety equipment. Any opening, exchanging parts or modifying the original equipment is undertaken at the user s own responsibility and risk. Ordering When ordering, please give name and type reference. Example: SKP10.111B27 - Actuator - AC 220...240 V / 50 Hz - Without limit and auxiliary changeover switches Technical Data SKP... General valve data Mains voltage (refer to «Type summary» AC 220 V 15 %...AC 240 V +10 % AC V 15 %...AC 110 V +10 % Mains frequency 50...60 Hz ±6 % Power consumption (depending on mains voltage) Switching capacity of auxiliary switch Setting range of auxiliary switch max. 20 VA On time % Opening time for full stroke approx. 2 mm / s Closing time Mounting position 6 (2) A, AC 250 V (if built in) 4...96 % stroke (if built in) depending on nominal size 6...12 s (extended opening time below 0 C) < 1 s 7641z37/0 Degree of protection IP 54 Weight - Without governor - with governor approx. 1250 g approx. 1650 g 8/17

orms and standards Environmental conditions Transport IEC 721-3-2 Climatic conditions class 2K2 Mechanical conditions class 2M2 Temperature range -15...+60 C (extended opening time below 0 C) Humidity < 95 % r.h. Operation IEC 721-3-3 Climatic conditions class 3K5 Mechanical conditions class 3M2 Temperature range -15...+60 C (extended opening time below 0 C) Humidity < 95 % r.h. Condensations, formation of ice and ingress of water are not permitted! CE conformity According to the directives or the European Union Electromagnetic compatibility EMC 89 / 336 EWG incl. 92 / 31 EWG Directive for gas-fired appliances 90 / 396 EWG Gas pressure governor General data Valves General valve data Control class A to DI E 88 Control mode P (proportional) Setting range 0...250 mbar Vent pipe Recommended min. distance between impulse pipe connection and gas valve Dia. of impulse pipes Impulse pipe connections Max. inlet pressure Perm. test pressure «PG» Perm. vacuum «PG» Balanced pressure governor (only SKP20.130B27) Compensating variable Pressure of combustion air not required with inlet pressures up to mbar 5 x nominal size min. 4 mm internally threaded Rp ¼ like valve 1 bar 200 mbar E 12067-1 pressure of combustion air max. 50 mbar Valve class A to E 161 Valve group 2 Perm. medium temperature max. + 60 C Operating pressure, etc. refer to «Type summary» Types of gas to DVGW gas families I, II, III and air Weight refer to «Dimensions table» 9/17

Functions Single-stage actuators 2-stage actuators Actuators with gas pressure governor When an opening command is given, the pump is switched on and the relief valve closed. From the nearly filled reservoir below the piston, the oil is now pumped into the chamber above the piston, causing the piston to move downwards and thus opening the valve against the force of the return spring. The pump remains activated until a closing command is given. When closing, or in the event of a power failure, the pump stops and the relief valve opens the bypass, allowing the return spring to push the piston upward again. The relief valve is sized such that the gas valve fully closes within about 0.6 seconds. With these actuators, opening starts the same way as with the single-stage actuators. However, when the low-fire position is reached, the disk actuates switch «V1» via a lever system, which is adjusted for the low-fire stroke. The pump is now switched off so that the valve disk maintains its present position. The pump will not be activated again until the burner control feeds power to terminal 3 of the actuator be it directly or via the load controller. High-fire stroke is reached when switch «V2» switches over, thus cutting the power supply to the pump. If the load controller cuts the power supply to terminal 3, the relief valve is opened until the low-fire position is reached. If terminals 1 and 3 are without power, the actuator returns to its fully closed position in less than 1 second. When using a gas pressure governor, the outlet pressure acting on the diaphragm represents the actual value. The diaphragm is supported by a spring the force of which is adjustable, representing the setpoint. The movements of the diaphragm are transferred to a lever system which acts on a ball valve located in the bypass between the suction and pressure side of the pump. If the actual value lies below the setpoint, the bypass is closed so that the actuator can open the gas valve. If the actual value exceeds the setpoint, the bypass is opened to some degree so that a certain amount of oil can return from the pressure side to the reservoir. The piston travels upward and the gas valve closes a little bit more. This counter-movement ends as soon as the actual value equals the setpoint. In this position, the opening of the bypass is such that the return flow through the bypass corresponds to the current oil output of the pump. Control accuracy is very good since small movements of the diaphragm are sufficient to trigger the control functions described above. The control characteristics are that of a P-controller with a very small proportional band. SKPx3... with connecting cable 10/17

Assignment of connection terminal V1 (M, P) V1 (M, P) V2 V1 (M, P) 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 % V2 V1 0 V1 I II III + + + V1 V2 + 7641z38/1200 + Single-stage 2-stage O or OFF Only with SKP13... or SKP23... single-stage Legend V Control input V1 Control input stage 1 V2 Control input stage 2 Screw for setting the switching point of auxiliary changeover switch Fuses, etc., must comply with local regulations Connection diagram, single-stage with auxiliary changeover switch L R 1 4 2 5 6 2 H 4...96 % Legend Potential-free auxiliary switch (adjustable), refer to «Technical Data» (only with actuators using auxiliary switches, refer to «Type summary») H Stroke of stem R Temperature or pressure controller, switch,... 2 Actuator SKP... 7641a01/0500 11/17

i i i i i i i i i Minimum flow rate required when using the SKP2... actuator The charts below show the minimum flow rates «Q» required, depending on the inlet pressure «Pi» and outlet pressure «Po» adjusted on the gas pressure governor. The flow rate may never fall below these minimum levels because too small flow rates at high inlet pressures cause pressure control to hunt. By screwing the AGA25 damping throttle into the governor s vent opening, oscillations can be suppressed to a certain degree (start-up characteristic with low-fire loads). The limit values are thus lower than those given in the charts below. All curves of the VGG... and VGF... are only applicable to the valve types with profile (VG...P) 1200 0 800 5 15 40 1200 0 800 5 15 40 1200 0 800 5 15 40 600 600 600 400 200 1/2" 400 200 400 3/4" 200 1" 0 2 4 6 8 10 12 14 16 18 20 0 10 20 30 40 50 0 10 20 30 40 50 600 500 400 300 200 5 15 40 11/2" D40 0 20 40 60 80 600 500 400 300 200 5 15 40 2" D50 0 20 40 60 80 300 250 200 150 50 5 15 0 40 80 120 160 200 40 3" D65 D80 300 250 200 150 50 7641d03/0500 5 1540 VGH: D80 0 40 80 120 160 200 300 250 200 150 50 250 200 150 50 5 15 40 5 15 40 300 VGH: D 0 40 80 120 160 200 VGH: D125 0 40 80 120 160 200 Example for 2 valves Pi = 300 mbar Po = mbar Qmin = 40 m³ / h air = 40 x 1.24 m³ / h natural gas = 49.6 m³ / h natural gas 12/17

1 f = dv (gas) 13/17

Dimensions Dimensions in mm SKP10... SKP20... 32.5 Rp1/4 Pg11 on both sides Rp1/4 Pg11 on both sides Atmosphere 21.5 104.8 194.1 21.5 194.1 210.2 229.2 5.5 7641m07e/0201 74 86 104.8 86 74 7641m08e/0201 106 74 86 74 86 111.7.5 143.5 5.5 Cover with connector for SKP13... / SKP23... Cover with connector to DI 43650 design A (ISO 4400) A-A M3 X A 30.5 To adjust auxiliary switch, remove cover A B-B 7641m12e/0201 19 15 B B 12.3 102.8 2 14/17

Connecting cable for SKP13... or SKP23... Contact markings L2 optional contact L2 PE PE L1 max. 38 7641m10e/0201 min. 4.5 210 min. 4.5 15/17

Dimensions and weights of valves without actuator Type A B C D E F G G H J K L M P Q R ¹) S T SW* kg VGG... ½ --- --- 96 79 80 109 --- --- --- 32 --- --- --- --- --- --- --- 28 31 46 0.8 ¾ --- --- 96 79 80 109 --- --- --- 32 --- --- --- --- --- --- --- 28 31 46 0.8 1 --- --- 96 79 80 109 --- --- --- 32 --- --- --- --- --- --- --- 28 31 46 0.75 1½ --- --- 126 102 126 150 --- --- --- 41 --- --- --- --- --- --- --- 34 34 60 1.4 2 --- --- 130 107 126 170 --- --- --- 50 --- --- --- --- --- --- --- 34 34 75 1.95 3 --- --- 191 163 185 310 110 --- 68 --- --- --- --- --- --- --- --- 62 120 13.4 VGF... D40 13 3 126 102 126 200 --- --- --- 41 19 150 110 88 45 90 4 36 36 --- 6 D50 13 3 130 107 126 230 --- --- --- 50 19 165 125 102 45 90 4 42 42 --- 7.5 D65 16.5 3 191 163 185 290 108 148 95 92 19 185 145 120 45 90 4 --- --- --- 15.3 D80 19 3 191 163 185 310 118 158 102 19 200 160 131 22.5 45 8 --- --- --- 17.9 VGH... D80 15 3 --- --- 160 310 102 --- 105 159 19 200 160 131 22.5 45 8 95 95 --- 16.3 D 16 3 --- --- 160 350 102 --- 105 166 19 220 180 157 22.5 45 8 95 95 --- 18.6 D125 17 3 --- --- 160 400 102 --- 121 174 19 250 210 187 22.5 45 8 95 95 --- 23.4 1) umber of holes For standards for flanges and threads, refer to «Type summary / Valves» * Width across flats VGH... / D80...125 E G 3/4 P M L Q J H R 4 x Rp 1/4 S T A B K 7641m05/0500 F VGF... / D 40...50 VGF... / D 65...80 4 x Rp 1/4 86 S T P Rp 1/4 G G 86 Rp 1/4 P C D Q M L Q M L J R R D J H 2 x G 3/4 S 80 60 E F A B K 80 C E F A B K 7641m04/0500 7641m02/0500 16/17

VGG3 G 86 G VGG ½...2 86 Rp 1/4 Rp 1/4 JD D J H D SW 2 x G 3/4 T D D C D C SW 4 x Rp 1/4 E S T 80 F 80 E 7641m01/0500 F 7641m03/0500 Mounting surface for actuator SKP... or adapter flange AGA60 for SQX... 2001 Siemens Landis & Staefa Produktion GmbH 17/17