Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Similar documents
Pneumatic Systems. Module 3: Logic Operations in Electropneumatics. IAT Curriculum Unit PREPARED BY. August 2008

[You may download this article at: ]

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

Programmable Logic Controller. Mat Nor Mohamad

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)

SAP E & C ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (FOR ITI) (PRODUCT CODE: SAP 20B-I)

The galvanic separation of the primary or actuating circuit and the load circuits

Control Relays Overview

Solenoid valve. Solenoid Coil

G. Prede D. Scholz. Electropneumatics. Basic Level

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer:

Input, Control and Processing elements

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:

Basics of Control Components

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Electric Motor Controls BOMA Pre-Quiz

: Automation Laboratory 1

Actuators and directional control valves

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.

Type SOQ Negative Sequence Time Overcurrent Relay

Relay. for Experiments with the fischertechnik Expansion Kit. Order No

Functions provided by measuring relays in railway equipment

Introduction. Pre-Lab

ELECTRO HYDRAULIC & ELECTRO PNEUMATIC

Lesson 5: Directional Control Valves

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Courseware Sample F0

LECTURE 15 TO 17 DIRECTIONAL CONTROL VALVES FREQUENTLY ASKED QUESTIONS

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Ch 4 Motor Control Devices

MOTOR TERMINAL CONNECTIONS

» Principals of Spider -Valve VA series

PNEUMATIC & HYDRAULIC SYSTEMS

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS.

RF Control of Pneumatic Actuators

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

OVERLOAD PROTECTION. All electrical circuits must have some means of protecting against overload.

Learning System for Automation and Communications. Electropneumatics. Workbook Basic Level S1 K1 K1 Y1

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

INTEGRATED ELEMENTS. 1. FLIP-FLOP VALVES (pneumatic) ORDER CODIFICATION : AZ100354

CAPACITOR DISCHARGE UNITS

~ SERVICE SPECIFICATION SU-4522-A ~

The pneumatic circuit and parts' list needed to perform this operation are shown by Figure C.1.

MOTOR TERMINAL CONNECTIONS

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Shaper Automation Using Electro-Pneumatic Devices And Plcs

Horizontal Circuit Switchers

Horizontal Circuit Switchers

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

The CASCADE Method. IA Cascade Method

Industrial Automation Commonly-Used Terms

Circuit board for R-471/472/481/482 with 1/8 NPT ports SUPPLY. 1/8 NPT typ.

MOTOR CONTROLLERS. STATE the function of motor controllers.

Jogging and Plugging of AC and DC Motors. Prepared by Engr. John Paul Timola, LPT

Electric control panel

Module 6. Actuators. Version 2 EE IIT, Kharagpur 1

Installation Sheet January, 2016 Supersedes February, 2013

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

Pneumatics Fundamentals

4.0 OPERATION Type ITH-T Relay

PREHEATER BYPASS SYSTEMS

4 Redundant Control System

For system diagrams and component identification

Type SDV7 distribution circuit breaker family

Time delay relays. The following is a timing diagram of this relay contact's operation:

Instructions. for the installation of the KPC-MDT portion control kit

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

Electrohydraulics Basic Level Textbook TP 601

Pneumatic Control System

Basic Electrically-Controlled Hydraulic System

A Novel Technique for Energy & Cost Effective Drives for AC & DC Motors

AR12 & AR20 Wiring diagram (multifunction display)

MP7650 CONTROLLER. Lake-Shore-Electric.com MP7650 Controller STANDARD FEATURES 1.0 INTRODUCTION

solenoids & relays solenoids & relays

Euclid Full Voltage Magnet Controller

Accessories and spare parts

Exercise 4-1. Friction Brakes EXERCISE OBJECTIVE DISCUSSION. Understand the construction and operation of friction brakes.

Horns, Wiper, and Washer System Operation

RELAYS. Figure Relay construction.

THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

The Contactor. Antonino Daviu, Jose Alfonso Departamento de Ingeniería Eléctrica. Universitat Politècnica de València

PNEUTRAINER-400 Pneumatics - Electropneumatics

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600

HYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics

Automatic Speed Breaker System

The Norwood Science Center. Energy Grade 4

TWO HAND NON-TIE-DOWN CONTROLS SC SERIES

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

Redundant Control System

PNEUMATIC CIRCUIT BOARDS PNEUMATIC CIRCUIT BOARD SELECTION GUIDE

MECHATRONICS LAB MANUAL

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

Chapter B-6. Chapter 6. Systems. Festo Didactic TP101

Hi-Cyclic Magna-Cycle Valves

Transcription:

ELECTRO-PNEUMATIC

Push button switches A push button is a switch used to close or open an electric control circuit. They are primarily used for starting and stopping of operation of machinery. This causes set of contacts to open or close. Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Push button switches Momentary push buttons return to their unactuated position when they are released. Maintained (or mechanically latched) push buttons has a latching mechanism to hold it in the selected position. The contact of the push buttons, distinguished according to their functions, i) Normally open (NO) type ii) Normally closed (NC) type iii) Change over (CO) type.

Normally open (NO) type In the NO type, the contacts are open in the normal position, inhibiting the energy flow through them. But in the actuated position, the contacts are closed, permitting the energy flow through them.

Normally closed (NC) type In the NC type, the contacts are closed in the normal position, permitting the energy flow through them. And, the contacts are open in the actuated position, inhibiting the energy flow through them.

Changeover contact A changeover contact is a combination of NO and NC contacts.

Direct and Indirect Control: Direct Control: The piston rod of a single-acting cylinder is to be extended when pushbutton S1 is pressed and retracted when the pushbutton is released. Indirect Control: If the pushbutton is pressed in an indirect control system, current flows through the relay coil. Contact K1 of the relay closes, and the directional control valve switches. The piston rod advances.

Direct Control of Single Acting Cylinder: The electrical circuit diagram for direct control of a singleacting cylinder is shown in Figure.

Direct Control of Single Acting Cylinder: Forward stroke: The circuit is closed when push button PB closes. Magnetic field is produced in the coil Y. Armature in the coil opens the passage for the compressed air. The compressed air flows from 1 to 2 of the 3/2 DCV to cylinder, which travels to the final forward position.

Direct Control of Single Acting Cylinder: Return stroke: When the push button PB is released, circuit is interrupted. Magnetic field at coil Y collapses, the 3/2 way valve switches back to its original position. The compressed air in the cylinder then exhausts through port 3 of the DCV and the cylinder travel to the final rear position.

Direct Control of Double Acting Cylinder (extended): The electrical circuit diagram for direct control of a doubleacting cylinder is shown in Figure.

Direct Control of Double Acting Cylinder (extended): Forward stroke: The double acting cylinder is controlled by 5/2 way valve. When the pushbutton PB is pressed, coil Y is energised and the directional control valve is activated by compressed air via pilot control. The piston travels to the final forward position.

the final rear position. Direct Control of Double Acting Cylinder (retracted): Return stroke: On release of PB, circuit is interrupted. Magnetic field at coil Y collapses, the return spring of 5/2 becomes active and the 5/2 way valve switches back to its original position. The compressed air in the cylinder then exhausts through port 5 of the 5/2 DCV and the cylinder travel to

RELAY A relay is an electro magnetically actuated switch. It is a simple electrical device used for signal processing. Relays are designed to withstand heavy power surges and harsh environment conditions.

When a voltage is applied to the solenoid coil, an electromagnet field results. This causes the armature to be attracted to the coil core. The armature actuates the relay contacts, either closing or opening them, depending on the design. A return spring returns the armature to its initial position when the current to the coil is interrupted.

Indirect Control of Single Acting Cylinder The electrical circuit diagram for indirect control of a singleacting cylinder is shown in Figure.

Indirect Control of Single Acting Cylinder Return stroke: On release of PB, circuit is interrupted. This de-energises a relay K1. The magnetic field at coil Y is collapses due to the opening of contact K1 the 3/2 way valve switches back to its original position. The compressed air in the cylinder then exhausts through port 3 of the DCV and the cylinder travel to the final rear position.

Indirect Control of Single Acting Cylinder Forward stroke: The circuit is closed when push button PB closes. Closing of PB energises a relay K1. The coil Y is energised via normally open contact K1 (indirect energising). A magnetic field is produced in armature of the coil Y opens the passage for the compressed air. The compressed air flows from 1 to 2 of the 3/2 DCV to cylinder, which travels to the final forward position.

In-direct Control of Double Acting Cylinder (extended): The electrical circuit diagram for in-direct control of a double-acting cylinder is shown in Figure.

In-direct Control of Double Acting Cylinder: (retracted) The electrical circuit diagram for in-direct control of a doubleacting cylinder is shown in Figure.

Indirect Control of double acting cylinder (using 5/2 way, double solenoid)

spring. Indirect Control of double acting cylinder (using 5/2 way, double solenoid) Forward stroke: When PB1 is pressed, coil Y1 is energised and 5/2 way DCV changes over. Piston travels out and remains in the final forward position until a signal is applied to coil Y2. The 5/2 DCV will remain in the last position because it is double solenoid valve and has no return

Indirect Control of DAC (using double solenoid) Return stroke: When the push button PB1 is released and PB2 is pressed. Opening of Push button PB1 deenergises a relay K1. Magnetic field at coil Y1 is collapses due to opening of contact K1. Closing of PB2 energises Y2 and the piston returns to its original position as a result of changeover of the 5/2 way valve.

Control of double acting cylinder OR logic (Parallel circuit) The piston of a DAC is to travel out when either one of two pushbutton switch is pressed. It is to return when both are released. When PB1 or PB2 are pressed coil Y1 is energised. The DCV switches over and the piston travels to the final forward position. When both the PB switches are released, the signal is removed from Y1 and the cylinder travels back to its original position.

Control of double acting cylinder OR logic (Parallel circuit)

Control of double acting cylinder AND logic (Series circuit) The piston of a DAC is to travel out when both push button switch is pressed. If only one PB is pressed, there is no movement. When PB1 or PB2 are pressed coil Y1 is energised. The DCV switches over and the piston travels to the final forward position. When one of the PB switches are released, the signal is removed from Y1 and the cylinder travels back to its original position.

Control of double acting cylinder AND logic (Series circuit)

Automatic control of DAC (spring return)

Automatic control of DAC (spring return)

Direct control of automatic control of DAC (double solenoid)

Direct control of automatic control of DAC (double solenoid)

Indirect control of automatic control of DAC (double solenoid)

Indirect control of automatic control of DAC (double solenoid)

The switch on the relay has now bypasses the push switch. This is called as latching relay

A separate relay circuit to unlatch the earlier relay

When second relay is energized, the first one is de-energised.

Latching circuits A latch is an electronic circuit that has two inputs and one output. Latching circuit can be dominant ON or dominant Off. Dominant position refer to status of relay coil ( circuit) when both the start and stop signals are applied simultaneously

Latching circuit with Dominant OFF When Start button (PB1) and Stop button (PB2) are pressed simultaneously, if the circuit goes to OFF position, then such a circuit is called Dominant OFF latching circuit.

Latching circuit with Dominant OFF When we press START push button PB1 is pressed and released, following operations occurs: Relay coil K1 in branch 1 (vertical) is energised. All Contact of K1 closes. A NO contact of K1 in branch 2, is connected parallel to PB1. This NO contact of K1 latches the start push button. Therefore even if the PB1 is released, NO contact of K1 in branch 2 keeps coil K1 energised. There is another NO contact in branch 3, which is connected to Y1. When push button PB1 is pressed this also remain closed, as a result cylinder moves forward and remains there until stop button PB2 is pressed.

Latching circuit with Dominant OFF When we press STOP push button PB2 is pressed momentarily and released, following operations occurs: Relay coil K1 in branch 1 (vertical) is de-energised. All contact of K1 opens. NO contact of K1 in branch 2, which is connected parallel to PB1 is now open. This NO contact of K1 no more latches the start push button.

Latching circuit with Dominant OFF

Latching circuit with Dominant ON When Start button (PB1) and Stop button (PB2) are pressed simultaneously, if the circuit goes to ON position, then such a circuit is called Dominant ON latching circuit.

Latching circuit with Dominant ON When we press START push button PB1 is pressed and released, following operations occurs: Relay coil K1 in branch 1 ( vertical) is energised. All Contact K1 closes Notice that there is a NO contact of K1 in branch 2, which is connected parallel to PB1 and in series with PB2. This NO contact of K1 latches the start push button. Therefore even if the PB1 is released, NO contact of K1 in branch 2 keeps coil K1 energised. There is another NO contact in branch 3, which is connected to Y1. When push button PB1 is pressed this also remain closed, as a result cylinder moves forward and remains there until stop button PB2 is pressed.

Latching circuit with Dominant ON When we press STOP push button PB2 is pressed momentarily and released, following operations occurs: Relay coil K1 in branch 1 ( vertical) is de-energised. All Contact K1 opens NO contact of K1 in branch 2, which is connected parallel to PB1 is now open. This NO contact of K1 no more latches the start push button. NO contact in branch 3 is also open now, which is denergises. As a result cylinder moves back to its home position and remains in home position until start button PB1 is pressed again.

Latching circuit with Dominant ON

Oscillating motion of a double acting cylinder (Forward )

Oscillating motion of a double acting cylinder (return )

TIME DELAY VALVES In many pneumatic/hydraulic systems, deliberate time delays are required to be introduced between specific operations. It is achieved using time delay valves. Such valve either generate or cancel an output signal after a specified interval of time with reference to the application or removal of the time signal. Time delay valves are classified as : 1. On delay timers 2. Off delay timers

On-delay timer When push button PB is pressed (ON), capacitor C is charged through potentiometer R1 as diode D is reverse biased. The time taken to charge the capacitor, depends on the resistance of the potentiometer (R1) and the capacitance(c) of the capacitor. By adjusting the resistance of the potentiometer, the required time delay can be set. When the capacitor is charged sufficiently, coil K is energised, and its contacts are operated after the set time delay. When the push button is released (OFF), the capacitor discharges quickly through a small resistance (R2) as the diode by passes resistor R1, and the contacts of relay (K) return to their normal position without any delay.

On-delay timer Pull in delay ( on delay timer)

On-delay timer

Off-delay timer

Off-delay timer