Networking: Wall-Mount Cabinets PROTEK Wall-Mount and Double-Hinge Cabinets PROTEK Single-Door Fan and Filter Thermal Packages, UL and NEMA Type 1

Similar documents
CHAPTER4 Wall-Mount Cabinets

Technical Operating Information AC Unit (T150116G100) Replacement Filter No

Wall-Mount Enclosures CONCEPT Wall-Mount Enclosures

ACCESSPLUS II Double-Hinge, Type 1

EQUIPMENT PROTECTION

PH (763) FX (763) hoffmanonline.com

Wall-Mount Cabinets ACCESSPLUS II Double-Hinge

Wall-Mount Cabinets ACCESSPLUS Double-Hinge

Rack Mount devices shown not included Custom cabinet shown

Wall-Mount Enclosures

ClimateCab Cabinets and Accessories

Standard Product. Wall-Mount Cabinets ULTRX Fiberglass Type 4X WiFi Cabinet and Accessories

Commercial Boxes and Enclosures COM-24 COM-66

Chapter Contents. Outside Plant Products

Guides (s-3482) Slides (s-2568) Rack-Mount Accessories. Accessories: Mounting Accessories

Standard Product. Type 4 Free-Stand Enclosures and Accessories

[ SOLUTIONS FOR AUTOMATION & CONTROL DEVICES: ]

ULTRX, Type 4X. Panel Size. Conductive

Phone: Fax: Web: -

Guides. Slides. Mounting Accessories Rack-Mount Accessories

Panel Size. Conductive

Shelves, Keyboard Trays and Gland Plates Folding Shelves

Standard Product Low Profile Type 12 One-Door Disconnect Enclosures

ACCESSORIES Electric Heater Compact Cooling Fans Floor Stand Kit PANELITE Enclosure Lights BULLETIN: A28SX

Type 4 Panel Enclosures

Type 4X Panel Enclosures

Type 4 Panel Enclosures

CHAPTER10 ACCESSORIES. Featured Products - TOOL-LESS SHELF PROVIDES EXPANDABLE SURFACE FOR EQUIPMENT

Modular Enclosure Solutions Specifier s Guide

C-Box Screw Cover with Knockouts NEMA 1. Commercial Enclosures Junction Boxes

Free-Stand, Single or Dual Access, Type 12

RMR Floor-Mount Enclosures

Operator System Enclosures

133 SAGINAW CONTROL & ENGINEERING STOCK PRICE LIST

RMR Free-Standing Enclosures

Double-Sided Solid Aluminum Shelf. Double-Sided, Solid Aluminum, Heavy Duty Shelf. Single-Sided Solid Aluminum Shelf. Single-Sided Solid-Steel Shelf

Type 4 Panel Enclosures

Wall-Mount Preferred-Cutout Disconnects Preferred Cutout, Disconnects, Type 12

FREE-STANDING ENCLOSURE ACCESSORIES FREE-STANDING ENCLOSURE ACCESSORIES. Swing-Out Panels. Panels (Full & Half Length) For Single-Door Enclosures

Preferred Cutout, Disconnect Enclosure, Type 12

CONNECT AND PROTECT. ProLine G2. The Next Generation Modular Solution

Uses, Certifications, and Standards Electrical Control and Instruments, Indoor/Outdoor EXTERNAL FEET, WALL standard UL 508, CSA C22.

GF-SERIES GLOBALFRAME CABINET SYSTEM

PROLINE Sloped-Front HMI System and Accessories. PROLINE Sloped-Front HMI, Type 4, 4X, 12. HMI - Human-Machine Interface: HMI Enclosure Systems

S /5000 BTU/Hr. 1000/1500 Watt

Climate Control Products

Unshrouded 60, 100 and 200 Watts Shrouded 60, 100 and 200 Watts

1.6 Accessories include tool-free snap-in technology options for air flow, cable management, shelves, power distribution units, etc.

CLIMAGUARD Outdoor Heat Exchangers

CLIMATE CONTROL PRODUCTS

Rittal TopTherm Filter Fans

FREE-STANDING CABINETS

ACCESSORIES FOR SZE2 CABINETS

Standard Product Hinged Back Plate

RMR Standard Wall-Mount Enclosures

GL66 SERIES STAINLESS STEEL HINGED COVER WALL-MOUNT ENCLOSURES

Product Data For FARNELL

Operating voltage 120, 230 V AC Air volume 24 m³/h (14.1 CFM) Rated power 13 W Size 1

any server any environment one source

CONCEPT Wall-Mount Enclosure Accessories

PANEL MOUNT EXPLOSION PROTECTED AIR CONDITIONERS

Frame Joining Kits. Free-Stand Cabinets PROLINE Accessories

Electronics Cooling. Thermoelectric Coolers. Protective Cooling: Thermoelectric

EB SERIES INSTRUMENT ENCLOSURES

Comfort. Description. Applications


AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Unshrouded 60, 100 and 200 Watts Shrouded 60, 100 and 200 Watts

14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

INDUSTRIAL THERMAL MANAGEMENT. Filter fans FL-Series

*Discover our other ranges: Select your range of Spacial steel wall-mounting enclosures. Spacial S3DC. Spacial S3X page 5/4. Thalassa PLM page 6/12.

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

Dimensions WxHxD [mm] Weight [kg]

Weather Protective Devices

CA3000C & CA6000C Cartridge Air Cleaners

Emcor Cabinets and Enclosures

VERTIV XTE 401 SERIES. Ordering Guide

NETXTEND FLEX SERIES Equipment Enclosures

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

Standard Product. Polyester powder paint; RAL 7035 textured light gray standard Custom colors available

Deluxe Charging Carts, Standard Charging System

Door available front and rear

SC Series Cabinets and Accessories SC SERIES PRE-CONFIGURED CABINETS. V3 and V4

Industrial Enclosures

PROLINE Accessories PJ2F PJ2FD PJ2FHF2 PJ2FF PJ2FBF

AT30 SERIES BATTERY CHARGER

Type 4X Panel Enclosures

Comfort. Sewage Treatment Plants. Petrochemical Facilities, Oil Rigs. Unattended Pumping Stations. Chemical Storage and Handling Facilities

SERIES 14 SINGLE DOOR CONSOLES TECHNICAL DATA

F-SERIES TERAFRAME CABINET SYSTEM 27.6 W (700 mm) Cabinets

EQUIPMENT PROTECTION

INDUSTRIAL SOLUTIONS Wallmount Enclosures...pgs IND 1-46 Wireway/Trough...pgs IND Freestanding Enclosures...pgs IND FMD Enclosures...

TopTherm Filter Fans

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

Heavy-Duty Enclosures Type 12 Free Standing Disconnect with Sub Panel

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

ZEPHYR CABINET. Single & Twin Unit Cabinet Fans. Moving Your Way BULLETIN ZC15 TABLE OF CONTENTS

Transcription:

PROTEK Single-Door Fan and Filter Thermal Packages, UL and NEMA Type 1 Industry Standards UL 508A Listed; Type 1; File Number E619967 cul Listed per CSA C22.2 No. 9; Type 1; File Number E61997 NEMA / EEMAC: Type 1 IEC 60529, IP 30 Application PROTEK Fan and Filter Packages are ideal for protecting sensitive 19- rack equipment from harmful environmental contaminants such as falling dirt, dust and dripping water. Use where the ambient air can be used to cool the internal equipment and where protection from falling dirt and dripping water is needed. Filters assist in removing contaminants and are easily removed for periodic cleaning without accessing the cabinet. Top-mounted fans provide increased airflow and maximize heat dissipation of internally mounted equipment. Both top-mounted fans and bottom-mounted intake filters are positioned away from 19- rack-mounting areas. Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemically resistant Type 12 cabinets have window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. Type cabinets have solid doors and a padlock-capable, tamperresistant, quarter-turn latch (tool included). They provide easy operation and locking options in indoor and outdoor applications. One set of adjustable tapped rack angles included Optional square-hole (.375-) rack angles available for equipment mounting flexibility angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Specifications Doors made of 16 gauge steel; body made of 1 gauge steel Convenient studs provided on both door and body for bonding and grounding angles tapped 10-32 per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25- thick, scratch- and impact-resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty 10-32 screws included Pagoda top-mounted 6- fan and bottom-mounted 10- filter inlet Top shroud protects cabinet and fan from falling debris and dripping water Bottom-mounted air inlet with outside removable and cleanable filter Regular filter cleaning required for optimum thermal performance Operates on 110/115 VAC 50/60 Hz line voltage Standard NEMA 15 A plug internal to the cabinet (5-15P) Finish Pretreated steel coated with RAL 7035 light gray textured, low-gloss polyester powder paint. Other paint finishes available contact Hoffman Customer Service for details. Load Rating WARNING: The cabinet must be safely and correctly mounted to the wall to support the total weight of the cabinet and its contents. Due to various applications and wall constructions, consultation with a structural engineer and analysis of the mounting wall is advised. Standard Product PROTEK Single Window Door UL Type 1 Fan and Filter Packages mm Accessory Standard PTDW222GF 2.00 x 2.00 x 2.00 610 x 610 x 610 12 PTP22A CP22 PTRA192TPL PTRA192THL PTDW3622GF 36.50 x 2.00 x 2.00 927 x 610 x 610 19 PTP362A CP362 PTRA1936TPL PTRA1936THL PTDW822GF 8.50 x 2.00 x 2.00 1232 x 610 x 610 26 PTP82A CP82 PTRA198TPL PTRA198THL Technical Operating Information Fan Unit (6- Fan with Cord) Replacement Filter No. AFLTR10 Hz Voltage VAC CFM Watts @ 50/60 Hz Full Load Amp @ 50/60 Hz Noise SIL (db) 50/60 115 200/20 36/32.5/.36 50/56 13

Thermal Performance for Fan and Filter Packages PROTEK Fan and Filter Packages calculated thermal performance Max. Internal Temperature: 100 F Voltage / Hertz: 115 VAC/60 Hz Filters: Clean (Regular cleaning required to maintain airflow) Air Volume: 200 CFM (Exact CFM dependant on Voltage, Frequency, and filter efficiency) Max. Elevation: 6,000 ft. (Contact Hoffman for elevations above 6,000 ft.) Thermal Performance PROTEK Fan and Filter Packages Ambient Temperature ( F) 100 or above Not recommended Consider PROTEK Air Conditioner Package 95 316 90 632 85 98 80 126 75 1580 70 1896 65 2212 60 2528 55 28 Watts =.316 x CFM x delta T (degrees F) (at sea level) Delta T = Max internal temperature (degrees F) Ambient external temperature (degrees F) Ambient temperature is the air temperature in and around the intake opening of the cabinet. Fan cooling can never cool the equipment below ambient temperature. 135

PROTEK Single-Door Thermal AC Package, UL and NEMA Type or 12 Industry Standards PROTEK Air Conditioner Packages Indoor (Type 12) UL 508A Listed; Type 12; File Number E619967 cul Listed per CSA C22.2 No. 9; Type 12; File Number E61997 NEMA / EEMAC: Type 12 IEC 60529, IP 55 PROTEK Air Conditioner Packages Outdoor (Type ) UL 508A Listed; Type 12, ; File Number E619967 cul Listed per CSA C22.2 No. 9; Type 12, ; File Number E61997 NEMA / EEMAC: Type 12, IEC 60529, IP 66 Application The PROTEK Thermal Package is an excellent, off-the-shelf choice for mounting 19- rack network equipment in wet or dirty environments where filtration or air conditioning is required and floor space is at a premium. Complete Fan and Filter and Air Conditioner Packages are available to match application requirements. Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemically resistant Type 12 cabinets have window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. Type cabinets have solid doors and a padlock-capable, tamperresistant, quarter-turn latch (tool included). They provide easy operation and locking options in indoor and outdoor applications. One set of adjustable tapped rack angles included Optional square-hole (.375-) rack angles available for equipment mounting flexibility angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Cabinet shipped with air conditioner uninstalled Specifications Doors made of 16 gauge steel; body made of 1 gauge steel Convenient studs provided on both door and body for bonding and grounding angles tapped 10-32 per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25- thick, scratch- and impact-resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty 10-32 screws included Right-side-mounted T Line Indoor/Outdoor Air Conditioner Operates on 110/115 VAC 50/60 Hz line voltage Standard NEMA 15 A plug internal to the cabinet (5-15P) See table for technical operating information Routine maintenance required for optimum performance (see service manual) Finish Pretreated steel coated with RAL 7035 light gray textured, low-gloss polyester powder paint. Other paint finishes available contact Hoffman Customer Service for details. Load Rating WARNING: The cabinet must be safely and correctly mounted to the wall to support the total weight of the cabinet and its contents. Due to various applications and wall constructions, consultation with a structural engineer and analysis of the mounting wall is advised. Standard Product Single Window-Door UL Type 12 Air Conditioner Packages mm Accessory Standard Panel PTDW222GA 2.00 x 2.00 x 2.00 610 x 610 x 610 12 PTP22A CP22 PTRA192TPL PTRA192THL PTDW3622GA 36.50 x 2.00 x 2.00 927 x 610 x 610 19 PTP362A CP362 PTRA1936TPL PTRA1936THL PTDW822GA 8.50 x 2.00 x 2.00 1232 x 610 x 610 26 PTP82A CP82 PTRA198TPL PTRA198THL Standard Product Single Solid-Door UL Type Air Conditioner Packages mm Accessory Standard Panel PTDS222GA 2.00 x 2.00 x 2.00 610 x 610 x 610 12 PTP22A CP22 PTRA192TPL PTRA192THL PTDS3622GA 36.50 x 2.00 x 2.00 927 x 610 x 610 19 PTP362A CP362 PTRA1936TPL PTRA1936THL PTDS822GA 8.50 x 2.00 x 2.00 1232 x 610 x 610 26 PTP82A CP82 PTRA198TPL PTRA198THL Technical Operating Information AC Unit (T150116G100) Replacement Filter No. 10100091 Hz Voltage VAC Phase BTU/Hr @ Max. Ambient Temp. (watts) Full Load Amp Max. Ambient Temp. (ºF) Max. Ambient Temp. (ºC) Cord and Plug 60 (50) 110-115 1 800 (235 watts) 3.6 (3.8) 131 (125) 52 (52) 2- cord length 5-15PPlug 136

Thermal Performance for Air Conditioner Packages PROTEK Air Conditioner calculated thermal performance AC Performance: 800 BTU/hour or 235 watts Voltage / Hertz: 115 VAC/60 Hz Max. Ambient Temperature: 131 F M Ambient Temperature: -0 F Max. Internal Temperature: 100 F (Allowable) Thermal Performance PROTEK Air Conditioner Packages Ambient Temperature ( F) Cabinet Height: 2 Cabinet Height: 36 Cabinet Height: 8 130 15 N/A N/A 120 88 73 59 110 161 15 16 100 23 23 23 90 308 315 322 80 381 396 10 70 5 76 98 60 527 557 586 50 601 637 67 0 67 718 762 N/A = Not applicable and not recommended in these applications 1 BTU = 3.13 watts 137

PROTEK DH Double-Hinge, UL and NEMA Type or 12 Industry Standards UL 508A Listed; Type or 12; File Number E619967 cul Listed per CSA C22.2 No. 9; Type or 12; File Number E61997 NEMA/EEMAC: Type or 12 IEC 60529, IP66 or IP55 Application PROTEK DH Cabinets protect equipment in wet or dirty environments and can be pole- or wall-mounted. Available with reversible left or right hinging, the cabinet swings open to provide easy equipment service and installation access. Features Type 12 cabinets available with solid or window doors and have a locking wing knob with two keys. They provide security and convenience in indoor applications. Type cabinets have solid doors and a padlock-capable quarterturn latch. They provide easy operation and locking options in indoor and outdoor applications. Solid door provides complete physical and visual protection Window door, made with scratch resistant safety glass, allows equipment monitoring without opening the door to minimize contamination Double-hinged for easy equipment access Front access to center body hinging and back section latches Exclusive toolless self-fastening latch is easy to open, yet automatically closes securely Latch on front of door eliminates need to access sides to open door or back section latches Latch-free sides permit side of cabinet to be installed tightly into a corner Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemical resistant One set of adjustable tapped rack angles included Optional square hole rack angles available for equipment mounting flexibility angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Available modifications include paint colors, holes and cutouts, and custom sizes Specifications Doors and body made of 1 gauge steel Convenient studs provided on center section for bonding and grounding angles tapped 10-32 per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25 thick, scratch and impact resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty 10-32 screws included Finish Pretreated steel coated with RAL 7035 light gray textured, low gloss polyester powder paint. Other finishes available contact Hoffman Customer Service. Load Rating HEIGHT RATING 16.00 () 100 lb. (5. kg) 20.00 () 100 lb. (5. kg) 2.00 () 100 lb. (5. kg) 36.00 () 125 lb. (56.7 kg) 8.00 () 175 lb. (79. kg) Accessories PROTEK DH Type 1, or 12 Double-Hinged Wall-Mount Cabinet Accessory, page 1 PROTEK Polycarbonate Window Inserts, page 15 PROTEK, page 15 Options See the appropriate option for more information. Options include: PROTEK DH Type 1, or 12 Double-Hinged Wall-Mount Cabinet Accessory PROTEK Polycarbonate Window Inserts PROTEK 138

Standard Product mm Door Style UL/NEMA Type IP Rating Accessory Panel Standard Panel PTDHS16215G 16.00 x 2.00 x 15.00 06 x 610 x 381 8 Solid IP66 PTPDH162A A2P16 PTRA1916TPL PTRA1916THL PTDHS16215G 16.00 x 2.00 x 15.00 06 x 610 x 381 8 Solid 12 IP55 PTPDH162A A2P16 PTRA1916TPL PTRA1916THL PTDHW16215G 16.00 x 2.00 x 15.00 06 x 610 x 381 8 Window 12 IP55 PTPDH162A A2P16 PTRA1916TPL PTRA1916THL PTDHS20215G 20.00 x 2.00 x 15.00 508 x 610 x 381 10 Solid IP66 PTPDH202A A2P20 PTRA1920TPL PTRA192THL PTDHS20215G 20.00 x 2.00 x 15.00 508 x 610 x 381 10 Solid 12 IP55 PTPDH202A A2P20 PTRA1920TPL PTRA192THL PTDHW20215G 20.00 x 2.00 x 15.00 508 x 610 x 381 10 Window 12 IP55 PTPDH202A A2P20 PTRA1920TPL PTRA192THL PTDHS2215G 2.00 x 2.00 x 15.00 610 x 610 x 381 12 Solid IP66 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHS2215G 2.00 x 2.00 x 15.00 610 x 610 x 381 12 Solid 12 IP55 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHW2215G 2.00 x 2.00 x 15.00 610 x 610 x 381 12 Window 12 IP55 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHS36215G 36.50 x 2.00 x 15.00 927 x 610 x 381 19 Solid IP66 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHS36215G 36.50 x 2.00 x 15.00 927 x 610 x 381 19 Solid 12 IP55 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHW36215G 36.50 x 2.00 x 15.00 927 x 610 x 381 19 Window 12 IP55 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHS8215G 8.50 x 2.00 x 15.00 1232 x 610 x 381 26 Solid IP66 PTPDH82A A8P2 PTRA198TPL PTRA198THL PTDHS8215G 8.50 x 2.00 x 15.00 1232 x 610 x 381 26 Solid 12 IP55 PTPDH82A A8P2 PTRA198TPL PTRA198THL PTDHW8215G 8.50 x 2.00 x 15.00 1232 x 610 x 381 26 Window 12 IP55 PTPDH82A A8P2 PTRA198TPL PTRA198THL PTDHS222G 2.00 x 2.00 x 2.00 610 x 610 x 610 12 Solid IP66 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHS222G 2.00 x 2.00 x 2.00 610 x 610 x 610 12 Solid 12 IP55 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHW222G 2.00 x 2.00 x 2.00 610 x 610 x 610 12 Window 12 IP55 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHS3622G 36.50 x 2.00 x 2.00 927 x 610 x 610 19 Solid IP66 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHS3622G 36.50 x 2.00 x 2.00 927 x 610 x 610 19 Solid 12 IP55 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHW3622G 36.50 x 2.00 x 2.00 927 x 610 x 610 19 Window 12 IP55 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHS822G 8.50 x 2.00 x 2.00 1232 x 610 x 610 26 Solid IP66 PTPDH82A A8P2 PTRA198TPL PTRA198THL PTDHS822G 8.50 x 2.00 x 2.00 1232 x 610 x 610 26 Solid 12 IP55 PTPDH82A A8P2 PTRA198TPL PTRA198THL PTDHW822G 8.50 x 2.00 x 2.00 1232 x 610 x 610 26 Window 12 IP55 PTPDH82A A8P2 PTRA198TPL PTRA198THL 139

PROTEK DH Double-Hinge Fan and Filter Thermal Packages, UL and NEMA Type 1 Industry Standards UL 508A Listed; Type 1; File Number E619967 cul Listed per CSA C22.2 No. 9; Type 1; File Number E61997 NEMA / EEMAC: Type 1 IEC 60529, IP 55 Application PROTEK Fan and Filter Packages are ideal for protecting sensitive 19- rack equipment from harmful environmental contaminants such as falling dirt, dust and dripping water. Use for applications where the ambient air can be used to cool the internal equipment and where protection from falling dirt and dripping water is needed. Filters assist in removing contaminants and are easily removed for periodic cleaning without accessing the cabinet. Top-mounted fans provide increased airflow and maximize heat dissipation of internally mounted equipment. Both top-mounted fans and bottom-mounted intake filters are positioned away from 19-inch rack-mounting areas. Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemically resistant Type 1 cabinets have window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. One set of adjustable tapped rack angles included Optional square hole (.375 ) rack angles available for equipment mounting flexibility angles are plated and self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Double-hinged for easy equipment access Front access to center body hinging and back section latches Exclusive tool-less self-fastening latch is easy to open, yet automatically closes securely Latch on front of door eliminates need to access sides to open door or back section latches Latch-free sides permit cabinet to be installed tightly into a corner Specifications Doors made of 16 gauge steel and body made of 1 gauge steel Convenient studs provided on both door and body for bonding and grounding angles tapped 10-32 per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25- thick, scratch- and impact-resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty 10-32 screws included Pagoda top-mounted 6- fan and bottom-mounted 10- filter inlet Top fan shroud protects cabinet and fan from falling debris and dripping water Bottom-mounted air inlet with outside removable and cleanable filter Regular filter cleaning required for optimum thermal performance Operates on 110/115 VAC 50/60 Hz line voltage Standard NEMA 15 A plug internal to the cabinet (5-15P) Finish Pretreated steel coated with RAL 7035 light-gray, textured, low-gloss polyester powder paint. Other paint finishes available contact Hoffman Customer Service for details. Load Rating WARNING: The cabinet must be safely and correctly mounted to the wall to support the total weight of the cabinet and its contents. Due to various applications and wall constructions, consultation with a structural engineer and analysis of the mounting wall is advised. Bulletin: DWDH2 Standard Product Double-Hinged Window-Door Type 1 Fan and Filter Packages mm Accessory Standard Panel PTDHW222GF 2.00 x 2.00 x 2.00 610 x 610 x 610 12 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHW3622GF 36.50 x 2.00 x 2.00 927 x 610 x 610 19 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHW822GF 8.50 x 2.00 x 2.00 1232 x 610 x 610 26 PTPDH82A A8P2 PTRA198TPL PTRA198THL Load Ratings Height Max. Load Mounted to Center Section Max. Load Accessory Panel Mounted Rear Section to Collar Studs 16 100 lb. 50 lb. 20 100 lb. 80 lb. 2 100 lb. 100 lb. 36 125 lb. 200 lb. 8 175 lb. 300 lb. 10

Technical Operating Information Fan Unit (6- Fan with Cord) Replacement Filter No. AFLTR10 Hz Voltage VAC CFM Watts @ 50/60 Hz Full Load Amp @ 50/60 Hz Noise SIL 50/60 115 200/20 36/32.5/.36 50/56 db Thermal Performance for Fan and Filter DH Packages PROTEK Fan and Filter Packages calculated thermal performance Max. Internal Temperature: 100 F Voltage / Hertz: 115 VAC/60 Hz Filters: Clean (Regular cleaning required to maintain airflow) Air Volume: 200 CFM (Exact CFM dependant on Voltage, Frequency, and filter efficiency) Max. Elevation: 6,000 ft. (Contact Hoffman for elevations above 6,000 ft.) Thermal Performance PROTEK Fan and Filter Packages Ambient Temperature ( F) 100 or above Not recommended Consider PROTEK Air conditioner Package 95 316 90 632 85 98 80 126 75 1580 70 1896 65 2212 60 2528 55 28 Watts =.316 x CFM x Delta T ( F) (at sea level) Delta T = Max internal Temperature (degrees F) Ambient external Temperature (degrees F) Ambient temperature is the air temperature in and around the intake opening of the cabinet. Fan cooling can never cool the equipment below ambient temperature. 11

PROTEK DH Double-Hinge Thermal AC Package, UL and NEMA Type or 12 Industry Standards PROTEK Air Conditioner Packages Indoor (Type 12) UL 508A Listed; Type 12; File Number E619967 cul Listed per CSA C22.2 No. 9; Type 12; File Number E61997 NEMA / EEMAC: Type 12 IEC 60529, IP 66 PROTEK Air Conditioner Packages Outdoor (Type ) UL 508A Listed; Type 12, ; File Number E619967 cul Listed per CSA C22.2 No. 9; Type 12, ; File Number E61997 NEMA / EEMAC: Type 12, IEC 60529, IP 66 Application PROTEK DH Thermal Packages are an excellent, off-the-shelf choice for mounting 19- rack network equipment in wet or dirty environments where filtration or air conditioning is required and floor space is at a premium. These complete packages can be mounted to a pole or wall and hinged on the left or right. The mounted cabinet swings open to provide easy equipment service and installation access. Complete Fan and Filter and Air Conditioner Packages are available to match application requirements. Features Solid door provides complete physical and visual protection Window door, made with scratch-resistant safety glass, provides equipment monitoring without opening the door to minimize contamination Fully welded and ground body and door construction for longterm good appearance and durability Foam-in-place seamless gasket around door seals against outdoor air infiltration; is non-absorbing and chemically resistant Type 12 cabinets have window doors and a locking wing knob with two keys. They provide security and convenience in indoor applications. Type cabinets have solid doors and a padlock-capable, tamperresistant, quarter-turn latch (tool included). They provide easy operation and locking options in indoor and outdoor applications. One set of adjustable tapped rack angles included Optional square hole (.375 ) rack angles available for equipment mounting flexibility angles are plated and are self-grounding for durability and safety Collar studs provided on back of cabinet for mounting accessory panels Accessory panels for mounting additional accessories at the back of the cabinet include tie-down points and pre-drilled holes Plenum rated for use in air exchange areas Double-hinged for easy equipment access Front access to center body hinging and back section latches Exclusive tool-less self-fastening latch is easy to open, yet automatically closes securely Latch on front of door eliminates need to access sides to open door or back section latches Cabinet shipped with air conditioner uninstalled Specifications Doors made of 16 gauge steel and body made of 1 gauge steel Convenient studs provided on both door and body for bonding and grounding angles tapped 10-32 per EIA standards; made of 12 gauge self-grounding plated steel Window is clear,.25- thick, scratch- and impact-resistant safety glass Optional polycarbonate window (not plenum rated) can be fieldor factory-installed. Contact Hoffman Customer Service for factory installation. Twenty 10-32 screws included Right-side-mounted T Line Indoor/Outdoor Air Conditioner Operates on 110/115 VAC 50/60 Hz line voltage Standard NEMA 15 A plug internal to the cabinet (5-15P) See table for technical operating information Routine maintenance required for optimum performance (see service manual) Finish Pretreated steel coated with RAL 7035 light-gray, textured, low-gloss polyester powder paint. Other paint finishes available contact Hoffman Customer Service for details. Load Rating WARNING: The cabinet must be safely and correctly mounted to the wall to support the total weight of the cabinet and its contents. Due to various applications and wall constructions, consultation with a structural engineer and analysis of the mounting wall is advised. Bulletin: DWDH2 Standard Product Double-Hinged Window-Door Type 12 Air Conditioner Packages l mm Accessory Standard Panel PTDHW2229GA 2.00 x 2.00 x 29.00 610 x 610 x 737 12 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHW36229GA 36.50 x 2.00 x 29.00 927 x 610 x 737 19 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHW8229GA 8.50 x 2.00 x 29.00 1232 x 610 x 737 26 PTPDH82A A8P2 PTRA198TPL PTRA198THL Standard Product Double-Hinged Solid-Door Type Air Conditioner Packages l mm Accessory Standard Panel PTDHS2229GA 2.00 x 2.00 x 29.00 610 x 610 x 737 12 PTPDH22A A2P2 PTRA192TPL PTRA192THL PTDHS36229GA 36.50 x 2.00 x 29.00 927 x 610 x 737 19 PTPDH362A A36P2 PTRA1936TPL PTRA1936THL PTDHS8229GA 8.50 x 2.00 x 29.00 1232 x 610 x 737 26 PTPDH82A A8P2 PTRA198TPL PTRA198THL 12

Load Ratings Height Max. Load Mounted to Center Section Max. Load Accessory Panel Mounted Rear Section to Collar Studs 16 100 lb. 50 lb. 20 100 lb. 80 lb. 2 100 lb. 100 lb. 36 125 lb. 200 lb. 8 175 lb. 300 lb. Thermal Performance for Air Conditioner DH Packages PROTEK Air Conditioner calculated thermal performance AC Performance: 800 BTU/hour or 235 Watts Voltage / Hertz: 115 VAC/60 Hz Max. Ambient Temperature: 131 F M Ambient Temperature: -0 F Max. Internal Temperature: 100 F (Allowable) Thermal Performance PROTEK Air Conditioner Ambient Temperature ( F) Cabinet Height: 2 Cabinet Height: 36 Cabinet Height: 8 130 N/A N/A N/A 120 63 27 N/A 110 19 131 105 100 23 23 23 90 320 338 36 80 05 2 93 70 91 56 623 60 576 69 752 50 662 753 881 0 77 857 1011 N/A = Not applicable and not recommended in these applications 1 BTU = 3.13 watts 13

Accessories PROTEK Single-Door Type or 12 Wall-Mount Cabinet Accessory Where equipment mounting space is limited, Accessory increase cabinet capacity by providing a mounting surface for 19- equipment and accessories at the back of the cabinet. The panels mount on collar studs provided in the cabinet. They include tie downs for VELCRO Cable Wraps and mounting holes for rack angle brackets, shelves and other accessories. have white paint finish. PROTEK Accessories VELCRO is a trademark of Velcro Industries B.V. AxB AxB mm Material Fits Cabinet Size PTP22A 22.20 x 22.20 56 x 56 12 gauge steel 2.00 x 2.00 PTP362A 3.20 x 22.20 869 x 56 12 gauge steel 36.00 x 2.00 PTP82A 6.20 x 22.20 1173 x 56 12 gauge steel 8.00 x 2.00 PROTEK DH Type 1, or 12 Double-Hinged Wall-Mount Cabinet Accessory Where equipment mounting space is limited, Accessory increase cabinet capacity by providing a mounting surface for 19- equipment accessories at the back of the cabinet. The panels mount on collar studs provided in the cabinet. They include tie downs for VELCRO Cable Wraps and mounting holes for rack angle brackets, shelves, and other accessories. have a white paint finish over 12 gauge steel. VELCRO is a trademark of VELCRO Industries B.V. D /mm PTPDH162A 21.00 533 PTPDH202A 21.00 533 PTPDH22A 21.00 533 PTPDH362A 33.00 838 PTPDH82A 5.00 113 E /mm 13.00 330 17.00 52 21.00 533 21.00 533 21.00 533 Fits Cabinet Size 16.00 x 2.00 20.00 x 2.00 2.00 x 2.00 36.00 x 2.00 8.00 x 2.00 1

PROTEK Square- and tapped-hole rack angles fit into PROTEK single-and double-hinged cabinets. PROTEK Accessories Hole Type Fits Cabinet Height PTRA1916TPL Tapped 16.00 7 PTRA1916THL Square 16.00 7 PTRA1920TPL Tapped 20.00 10 PTRA1920THL Square 20.00 10 PTRA192TPL Tapped 2.00 12 PTRA192THL Square 2.00 12 PTRA1936TPL Tapped 36.00 19 PTRA1936THL Square 36.00 19 PTRA198TPL Tapped 8.00 26 PTRA198THL Square 8.00 26 PROTEK Polycarbonate Window Inserts Polycarbonate window inserts provide additional impact protection. They are field-installed in place of the safety glass provided with the enclosure. No special tools are required. AxB /mm Fits Cabinet Size Description PTWR162POLY 16.00 x 2.00 16.00 x 20.00 Clear, 0.23- thick 06 x 610 PTWR202POLY 20.00 x 2.00 20.00 x 2.00 Clear, 0.23- thick 508 x 610 PTWR22POLY 2.00 x 2.00 2.00 x 2.00 Clear, 0.23- thick 610 x 610 PTWR362POLY 36.00 x 2.00 36.00 x 2.00 Clear, 0.23- thick 91 x 610 PTWR82POLY 8.00 x 2.00 1219 x 610 8.00 x 2.00 Clear, 0.23- thick 15