Axiom Industries Ltd Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) Fax: (306)

Similar documents
Installation, Operation & Maintenance Instructions for MF-Solar Series Solution Feeders

Installation, Operation & Maintenance Instructions for MF Series Solution Feeders

Flow Max. by Duraself. Flow Max by Duraself. Fluid Pump. Installation and Owner s Manual (For Aftermarket Applications)

Flow Max Fluid Pump. by Duraself OEM INSTALLATION MANUAL

Rev: Flow Max 115V AC Fluid Pump

Troubleshooting WARNING

SHURFLO HIGH FLOW SYSTEM II 10.0 GPM MARINE FRESH WATER SYSTEM PRODUCT TECHNICAL DATA SHEET

Model &

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

PowerFLO 7800 Series 12 Volt DC Motor-Driven Diaphragm Pumps

Installation, Operation, and Maintenance Manual Outdoor Glycol Feed System JWOP /055/100

PowerFLO 5800/5900 Series

Secondary Coolant 301

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

END SUCTION CENTRIFUGAL PUMPS

Flojet Rewrites the Book on Small Pump Control

Installation, Operating, Maintenance and Safety Instructions for CW332 Pressurised water system for boats 24 volt d.c.

BMF TROUBLESHOOTING GUIDE

SHURFLO AQUA KING II STANDARD 3.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

SHURFLO AQUA KING II SUPREME 5.0 MARINE FRESH WATER PUMP PRODUCT TECHNICAL DATA SHEET

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

8000 / 10,000 / 12,000

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

PLUNGER PUMP SERVICE MANUAL

PLUNGER PUMP SERVICE MANUAL

Priming Systems Installation Instructions

Manifold Isolation Valves

New Fan Coil Piping Packages

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

30 GALLON TRAILER SPRAYER ASSEMBLY & OPERATION INSTRUCTIONS MANUAL TSC SKU#: VENDOR#: TS30G-CL

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

Model 116 DPI Switch Installation and Operating Instructions

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units

INDUSTRIAL PUMP 8000 SERIES

ELECTRIC FUEL PUMPS P/N , , & FUEL PRESSURE REGULATOR P/N

INSTALLATION INSTRUCTIONS

ProFlo FatBoy

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

PIPING PACKAGES TABLE OF CONTENTS

FUEL SYSTEM. Table of Contents. Specifications. Section 3A Fuel Delivery System. Models 6/8/9.9/10/15 CARBURETOR SPECIFICATIONS

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

Cleaning Systems Inc. 2 P Rev:03

Installation & Technical Guide. Domestic & Commercial.

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

WORKHORSE. Assembly / Operation Instructions / Parts

WORKHORSE. Assembly / Operation Instructions / Parts 15 & 25 GALLON SPOT SPRAYER

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

1/2" AIR DRIVEN DIAPHRAGM PUMP

Manual for all Rittenhouse Skid Mount & Trailer Sprayers

Operation & Service Manual

SERVICING INSTRUCTIONS

Foam Supply Kits FOAM EDUCTORS FOAM EDUCTORS FOAM EDUCTORS FOAM SUPPLY KITS

INSTALLATION AND OPERATION MANUAL MOUNTING ELECTRICAL

Operating and Installation Instructions

WEBER CARBURETOR TROUBLESHOOTING GUIDE

GeyserMax-Flow Series

OWNER S MANUAL Model: TR-40-EX ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly)

Matala. VersiFlow Series. Instruction and Maintenance Manual

Pulsation Dampeners NEW! Wanner Engineering Inc

Electric Fuel Pump FPM

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

earth safe DEF Systems for Critical Power

RV PRODUCT DATA SHEET

WORKHORSE. Assembly / Operation Instructions / Parts DELUXE ATV BOOMLESS SPRAYER

Accessories Standard Service Fixture Kits

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

Operators Manual. Recirculating Chiller /06/08

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

Installation Instructions

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and

ESE Series Cast Iron Sewage Pumps

PRE-PLUMBED SEWAGE SYSTEM

New Fan Coil Piping Package. Redefine your comfort zone.

DIGITAL GLYCOL FEEDER

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

PI1500X Power Inverter User s Manual

Installation & Operating Manual

OWNER S MANUAL. Model: FSUTL60-12V ( ) Technical Specifications. Assembly Instructions

OWNER S MANUAL. Model: FSUTL40-12V ( ) Technical Specifications. Assembly Instructions

Assembly / Operation Instructions / Parts

END SUCTION CENTRIFUGAL PUMPS

348002K/348012K Manifold Block Style Service Manual 12/2000

C627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide

INDUSTRIAL PUMP 8000 SERIES

Microprocessor Controlled Dental Vacuum System Installation Manual

Single-Valve Powerstation

Submittal. Front View Side View

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

Iron Gate Air Pump System Manual

Transcription:

INDUSTRIES LIMITED Installation, Operation & Maintenance Instructions for MF Series Solution Feeders Axiom Industries Ltd. 2615 Wentz Avenue Saskatoon, SK S7K 5J1 Ph: (306) 651-1815 Fax: (306) 242-3373 Email: sales@axiomind.com

INDUSTRIES LIMITED MF200 and MF300 HYDRONIC SYSTEM FEEDER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS The System Feeder is used to maintain a minimum system pressure within a hydronic heating or cooling system. It should be used to pressurize the system while system temperature is at it s lowest. Installation Instructions 1. Set System Feeder on a secure and level base or in the optional tank shelf. 2. Connect the unit to the system using copper or plastic tubing. Ensure that there is a system isolation valve installed to allow for isolation of the unit. DO NOT INSTALL A CHECK VALVE OR PRESSURE REGULATOR BETWEEN SYSTEM FEEDER AND SYSTEM. 3. Mount power supply and secure with mounting bracket. Do not power up System Feeder until a system connection is made and isolation valve is open. 4. If the System Feeder will be connected to an alarm system connect alarm circuit to terminals below discharge connection. 5. Install proper water/glycol mix in the tank to a level above minimum level indication on tank scale. A 30-50% Polypropylene Glycol is Recommended. 6. Open system isolation valve. 7. Insert DC plug into the System Feeder feeder first, and then plug power supply into 120v outlet. The red LED in the power supply cord should light up. If it does not, check the fuse and power receptacle. If system pressure is below pressure switch setting (18 psi) pump will start. 8. Turn mix/purge valve handle on front of unit to vertical position to purge air from pump. Once air is purged, turn valve handle to horizontal position and allow pump to pressurize system. The System Feeder will run until system is pressurized to approximately 18 psi. and shut-off. It may cycle rapidly a number of times while system pressure stabilizes and while air is removed from the system. The cycling will stop once system pressure rises above 18 psi due to thermal expansion. 9. If a higher fill pressure is required (up to 25 psi) the internal pressure switch may be adjusted by turning the center adjusting screw clockwise to increase pressure. Access to the pressure switch can be gained by lifting the left side of the top cover. 10. The MF200 is shipped with a small amount of 50% propylene glycol (non-toxic) in the discharge tubing between the pump and the check valve. This is to aid in priming. Please note that the pressure gauge supplied with the unit may read differently from another gauge, which may be installed elsewhere in the system. This may be due to gauge calibration or differences in elevation within the system and should not be a concern. The System Feeder does not require any scheduled maintenance. Should you wish to test pump operation, turn mix/purge valve to vertical position to start pump. Turning mix/purge valve handle to horizontal position will stop pump.

COLD STATIC FILL PRESSURE The cold static fill pressure (CSFP) in a closed hydronic system has to be high enough to accomplish three things. 1) Overcome the static head (height) between the fill point and the highest point in the system. 2) Provide adequate pressure (minimum 4 psig) at the top of the system for proper air venting. 3) Maintain adequate pressure at the inlet of the system pumps to prevent cavitation. The formula for calculating the required CSFP to satisfy points 1 & 2 is: (Static height in feet/2.31) + 4 = CSFP in psig. As an example, the CSFP for a system with a static height above the fill point of 40 feet would be: (40/2.31) + 4 = 21.3 psig. For most closed hydronic systems operating below about 210 F, maintaining the minimum topof-system pressure at 4 psig will be adequate to prevent pump cavitation even if the pumps are at or near the top of the system as well. IMPORTANT NOTE For air-charged diaphragm or bladder tanks, the air charge in the tank must be adjusted to equal the cold static fill pressure before it is connected to the system.

Purger Pump Expansion Tank MF 200 Connection Schematic MF 200 Packaged System Feeder

Connecting the Alarm Contacts in the MF Series to Other Alarm Systems The alarm switch contacts in the MF series are factory wired to be OPEN on LOW PRESSURE. The switch is SPDT, so if some other alarm system is connected to this alarm contact and can not be configured to work with an open contact, the wiring on the low-pressure micro-switch can be changed to provide a closed contact on low pressure. Remove the screws fastening the top cover to the unit and lift the cover to get access to the pressure switch. Disconnect the power before doing this. Pump Leads Switch Housing Contact Leads Wiring MF200 Pressure Switch For Closed Contact on Low Pressure The upper micro-switch controls the pump. The lower micro-switch is used for a low-pressure warning. Move the wire from the middle terminal on the lower micro-switch to the rear-most terminal as shown in the diagram above to get an open circuit on low pressure. You should now have a closed alarm circuit at low pressure.

LEGEND ITEM # PART # DESCRIPTION 1 MF200-1600 tank lid 1 24 2 3 MF200-1000 tank MF200-1300 pump & motor assembly 25 19 3 18 15 4 5 6 7 8 MF200-1400 fluid diverter block MF200-1410 diverter mounting bracket MF200-0800 in-tank float MF200-0200 adjustable pressure switch MF200-0400 pressure snubber 26 9 MF200-0900 brass reducer 7 8 26 9 14 13 27 16 21 10 11 12 13 14 MF200-1200 ¼ angle ball valve MF200-0930 3/8" plastic hose MF200-0700 pressure gauge MF200-0940 ¼ hose adapter MF200-0950 ½ OD clear hose 10 4 17 15 16 MF200-0960 ½ OD plastic tubing MF200-0910 foot valve strainer 12 17 MF200-0310 alarm hook up terminal block 18 MF200-0110 power adapter plug-in 5 19 MF200-1520 ½ plastc clamp 11 20 22 20 21 MF200-0970 cable clamp MF200-0101 120V to 24DCV power adapter 6 22 MF200-1420 power adapter bracket 23 23 24 MF200-0500 tank bung MF200-0110 side decal 25 MF200-1100 s/n decal 2 26 MF200-0970 5/8" plastic clamp 27 MF200-0980 ¼ check valve PROJECT CUSTOMER MF-200 (EXPLODE) AXIOM INDUSTRIES DRWG. NO. EQUIP. NO. JOB NO. DATE TLL-MF200-1005 PARTS LIST 13 OCTOBER 2005

LEGEND ITEM # PART # DESCRIPTION 1 MF200-1600 tank lid 1 24 2 3 MF200-1001 tank MF200-1300 pump & motor assembly 25 19 18 4 5 MF200-1400 fluid diverter block MF200-1410 diverter mounting bracket 3 6 MF200-0810 in-tank float 7 8 26 9 14 13 27 26 15 16 21 7 8 9 10 11 12 13 14 MF200-0200 adjustable pressure switch MF200-0400 pressure snubber MF200-0900 brass reducer MF200-1200 ¼ angle ball valve MF200-0930 3/8" plastic hose MF200-0700 pressure gauge MF200-0940 ¼ hose adapter MF200-0950 ½ OD clear hose 10 4 17 15 16 MF200-0960 ½ OD plastic tubing MF200-0910 foot valve strainer 12 17 MF200-0310 alarm hook up terminal block 18 MF200-0110 power adapter plug-in 5 19 MF200-1520 ½ plastc clamp 11 20 22 20 21 MF200-0970 cable clamp MF200-0101 120V to 24DCV power adapter 23 6 22 23 24 MF200-1420 power adapter bracket MF200-0500 tank bung MF200-0110 side decal 25 MF200-1100 s/n decal 2 26 MF200-0970 5/8" plastic clamp 27 MF200-0980 ¼ check valve PROJECT CUSTOMER MF-300 (EXPLODE) AXIOM INDUSTRIES DRWG. NO. EQUIP. NO. JOB NO. DATE TLL-MF300-1005 PARTS LIST 13 OCTOBER 2005

Installation Instructions for the RIA10-1-SAA Control Panel for use with MF200 & MF300 Feeders The MF series alarm dry contacts are factory wired to provide an OPEN contact on LOW PRESSURE. This is compatible with the alarm circuit in the RIA10-1-SAA panel. Connect terminals 1 and 2 from terminal block TB2 in the panel to the contact terminals located beside the power plug on the MF unit. 1 2 3 4 5 NC NO COM Terminals on MF unit TB2 in RIA10-1-SAA To disable the audible alarm in the RIA10-1-SAA panel, remove the jumper from the control board of the RIA10-1-SAA.

Troubleshooting Chart Symptom Possible Cause Resolution Pump will not start Fluid level in tank is low Add correct fluid. Check for cause of system fluid loss Blown fuse Check LED indicator light on power cord, check fuse and replace if needed (2.5 Amps) Power supply or Breaker Check LED indicator light on power cord, flip breaker or obtain power supply from reseller and replace Power supply unplugged or loose electrical connections Plug in power supply or correct faulty electrical connection Pressure switch out of adjustment Faulty pressure switch Pump failure Adjust pressure switch according to the manufacturers recommendations First obtain snubber from reseller and replace. If problem continues obtain pressure switch from reseller then replace Obtain pump from reseller and replace Pump will not shut off Air lock in pump Turn purge/mixing valve to prime pump Leak in system or pump Inspect system and repair leak Faulty pressure switch Obtain pressure switch and snubber from reseller then replace Pump will not prime Check valve stuck Tap check valve lightly Fluid level in tank is low Add correct fluid. Check for cause of system fluid loss Strainer on inlet hose is blocked Clean strainer Product in tank is too thick or Congealed glycol Inlet tubing leak is drawing air Clean strainer and check concentration of glycol mixture Replace tubing and repair leak Inlet/Outlet tube severely restricted (Kinked) Replace tubing Noisy / Rough operation Pump is overloaded and pump Obtain Replacement pump from

pressure switch not cutting out Loose pump head or drive screws Feeder is plumbed with rigid pipe causing noise to transmit reseller and install Tighten screws Plumb with PEX or plastic pipe Feeder Leaking Manifold block over tightened and cracked Loose fittings Pump has punctured diaphragm Obtain replacement manifold block from reseller and install Tighten fittings Obtain Replacement pump from reseller and install System pressure low Fluid level in tank is low Add correct fluid. Check for cause of system fluid loss Blown fuse Check LED indicator light on power cord, check fuse and replace if needed Power supply or Breaker Check LED indicator light on power cord, flip breaker or obtain power supply from reseller and replace Pressure switch out of adjustment Adjust pressure switch according to the manufacturers recommendations Snubber on pressure switch is plugged Obtain snubber from reseller and replace Faulty pressure switch Obtain pressure switch and snubber from reseller then replace Power supply unplugged or loose electrical connections Plug in power supply or correct faulty electrical connection Pump failure Obtain pump from reseller and install System pressure to high Pressure switch not adjusted to proper setpoint Snubber on pressure switch is plugged Faulty pressure switch Adjust pressure switch, refer to maintenance manual for instructions Obtain snubber from reseller and replace Obtain pressure switch and snubber from reseller then replace

Pump Cycles Continually Air is being removed from system and pump is only making up fluid Leak in system Check valve or Regulator installed between System Feeder and system No action required Inspect system and repair leak Remove check valve or regulator