General Purpose Toroidal Conductivity Sensors

Similar documents
General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

Rosemount 228. Toroidal Conductivity Sensor. Product Data Sheet July Series LIQ-PDS-228

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

ph/orp Sensor Model 399 ph/orp

NEW QUICK CABLE-TO-SENSOR RELEASE,

General Purpose ph/orp Sensors

Conductivity Sensors. Applications. 140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014

Insertion/Submersion Flow Through Sensor

General Purpose ph/orp Sensors

Conductivity Sensors. Applications

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

TUpH Retraction/Submersion/Insertion ph/orp Sensors

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

ENDURANCE. Sanitary Flange Conductivity Sensors. Models 403 and 403VP. Product Data Sheet PDS /rev.A June 2005

Toroidal Conductivity Sensor

For additional information, please visit our website at SENSOR SPECIFICATIONS

Dissolved Oxygen, ph, and Conductivity

Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017

Retractable ph/orp Sensors

ENDURANCE Conductivity Sensors

Dissolved Oxygen Measurement System with Air Blast Cleaner

Liquid Conductivity Two & Four Electrode Sensors

PN October Liquid Division. Mounting Solutions

Analytical Instruments Two-Electrode Conductivity Sensors

Conductivity. Inductive Conductivity Sensors. Features and Benefits DATA SHEET. Wide Measuring Range. Low-maintenance Design. Complete Digital System

TUpH 396, 396VP, 396P, 396PVP, 396R, 396RVP

Retractable ph/orp Sensors

Accessories Guide ph/orp/conductivity Sensors

Retractable ph/orp Sensors

PN /rev. B April Liquid Division. Mounting Solutions

Model 385+ Instruction Manual PN February ph/orp Sensor

Endurance TM Conductivity Sensors

Rosemount 402 and 402VP

Pasve Rotary Retraction Valve

Retractable ph/orp Sensors

Instruction Manual PN /rev.H March Model 385+ ph/orp Sensor

Combination ph/orp Sensor

Rosemount TM 242 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-242 Rev. F June 2017

Analytical Instruments Four-Electrode Conductivity Sensors for Process Monitoring Model TB4

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Triple Junction ph/orp Sensor

Combination ph/orp Sensor

COMBINATION ph SENSOR

UniMag DT Series Electromagnetic Flow Tubes

Triple Junction Sensor

Model Q45H/ Residual Chlorine Monitor...

Miniature Multimedia Valves

Encapsulated Differential ph and ORP Sensors (available in LCP, foreground, or Ryton body materials)

ProMinent delta Solenoid Diaphragm Metering Pumps

Mobrey MSM400 Ultrasonic sludge density measurement system

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP

Instruction Manual PN /rev.C June Models 140, 141, 142. Conductivity Sensor Assemblies

Instruction Manual PN /rev.G March 2012 Model 381+ ph/orp Sensor

Signet Conductivity/Resistivity Electrodes

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

381+ Rebuildable ph Sensor. Instruction Manual LIQ_MAN_381+ January 2013

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

Signet Conductivity/Resistivity Electrodes

Signet DryLoc ph/orp Electrodes

Mallard Control Control Valves

Signet DryLoc ph/orp Electrodes

SATRON VDt Differential Pressure Transmitter

Instruction Manual PN /rev.D September 2009 Model 385. Retractable ph/orp Sensor

Performance Series ph/orp Sensors

OPERATING INSTRUCTION MANUAL

Transmitting Transducer. Gas/Air Velocity Range:

Inductive conductivity meter

INTRODUCTION BODY SUB-ASSEMBLY (FIGURE 1) 2 G X L GLOBE CONTROL VALVE VALTEK SULAMERICANA. Top entry assembly: quick and easy maintenance

EPDM,(Options for Buna, Viton - Depending on Process) B-7 All Thread w/ Stainless Sleeve

Combination ph/redox (ORP) Sensors

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Royce Total Suspended Solids Systems. Water & Wastewater

SIGNET 2760 DryLoc ph/orp Preamplifier

TRANSMITTER ATTACHES TO THIS SURFACE

Variable Area Flowmeters Ori-Flowrator TM Meters

PISTON STYLE GAUGE. Mid-West Instrument

Digital ph transmitter

Inductive conductivity meter

Signet ph/orp Electrodes

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

High Purity ph Sensor

* * Rev. 9 01/18 Product Manual

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

Instruction Manual PN /rev.C May Model 242. Flow-Through Toroidal Conductivity Sensor

Digital ph transmitter

Signet ph/orp Electrodes

In Situ Oxygen Transmitter For High Sulfur Environments

Combination ph/redox (ORP) Sensors

Eclipse. The Power of Design Innovation. Series

Instruction. MI September PH12 Series ph and ORP Sensors and Accessories Installation, Troubleshooting, and Maintenance

Technical Information Cleanfit CPA451

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

AGUABEL. Index. Aguapure Aguapure Lara APS 3. P-Pump 4. Aspendose 5. Tank for chemical 6. Tank with mixer 6. Glass Sensor 7.

SATRON VVFe Pressure Transmitter

Transcription:

Product Data Sheet PDS 71-226/228/revF January 2011 Model 226 and 228 General Purpose Toroidal Conductivity Sensors NON-CONTACTING (TOROIDAL) SENSORS resist corrosion and fouling. SENSORS ARE IDEAL for measuring concentrations of acid, base, and salt solutions. A VARIETY OF MOUNTING CONFIGURATIONS ARE AVAILABLE: submersion, insertion, and retractable. APPLICATIONS Rosemount Analytical toroidal conductivity sensors are ideal for use in corrosive liquids or in liquids containing high levels of suspended solids that would otherwise corrode or foul metal-electrode sensors. Toroidal conductivity sensors are also well-suited for measuring highly conductive electrolyte solutions. FEATURES The Model 226 and 228 toroidal (inductive) conductivity sensors consist of a pair of wire-wound metal toroids overmolded with either corrosionresistant PEEK or Tefzel 1. When the sensor is immersed in a conductive liquid and an AC voltage is applied to the drive coil, a voltage is induced in the liquid surrounding the coil. The voltage causes an ionic current to flow proportional to the conductance of the liquid. The ionic current induces a current in the receive coil, which the analyzer measures. The induced current is directly proportional to the conductivity of the solution. Toroidal sensors work well in highly conductive liquids, up to about 2 S/cm (2,000,000 us/cm). Performance in low conductivity samples is somewhat limited, with the minimum conductivity depending on the dimensions of the toroids, the number of windings in each, and the analyzer. When used with the Model 1056 and 56 analyzer the limits are 15 us/cm for the 228 sensor and 5 us/cm for the 226 sensor. When used with other instruments, the limits are 200 us/cm for the 228 sensor, and 50 us/cm for the 226 sensor. The measurement is insensitive to flow rate and direction. The sensor must be installed so that it is completely flooded, and the toroid hole must remain open. The Model 226 and 228 sensors have integral RTDs to allow temperaturecompensated conductivity measurements. A insertion/retraction assembly is available for the Model 228. MODEL 226 MODEL 228 MODEL 228 with retraction assemblies 1 Tefzel is a registered trademark of E.I. dupoint de Nemours and Co.

MODEL 226 SUBMERSION/INSERTION SENSOR The Model 226 is a rugged, large bore sensor molded in glass-filled PEEK (polyetheretherketone). A metal frame supports the toroids and reinforces the mounting shaft, so the sensor can readily withstand harsh conditions. The large bore means the sensor resists plugging, so the sensor is ideal for liquids containing high levels of suspended solids that would tend to plug the smaller opening in the 228 sensor. The large toroids in the 226 sensor allow it to measure lower conductivities than the 228 sensor. MODEL 228 SUBMERSION/INSERTION SENSOR The Model 228 has rugged construction similar to the 226 sensor. A metal frame supports the toroids and reinforces the mounting shaft, so the sensor tolerates high vibration applications such as drilling mud shaker trays. The metal frame and toroids are overmolded with either PEEK (glass-filled) or Tefzel (glass-filled or unfilled).there are no seams or welds to crack and cause leakage and failure. RETRACTION ASSEMBLIES FOR THE MODEL 228 SENSOR The retraction assembly allows the 228 sensor to be removed from piping and tanks without shutting down and draining equipment. Manual and mechanical retraction assemblies are available. Each requires a 1-1/2 inch full port ball valve, which must be ordered separately. Two wash ports in the retraction chamber allow the sensor to be washed clean of corrosive liquids before it is removed. SPECIFICATIONS (Model 226) Conductivity range: analyzer minimum maximum 1056 and 56 5 us/cm 500 ms/cm all others 50 us/cm 1000 ms/cm Process connection: option connection -80 1-inch MNPT -81 7/8-inch 9 UNC Wetted Materials: Glass-filled PEEK Temperature: 248ºF (120ºC) maximum Pressure: 295 psig (2135 kpa abs) Cable length: 20 ft (6.1 m) Maximum cable length: 200 ft (61 m) Installation: Install the sensor so that it is completely immersed in the process liquid. Mounting in a vertical pipe run is best. If the sensor must be installed in a horizontal pipe run, place the sensor in the 3 o clock position. Weight/shipping weight: 2 lb/3 lb (1.0 kg/1.5 kg) (rounded up to nearest 1 lb or 0.5 kg) MILLIMETER INCH 226-80 Dimensional Drawing 2

SPECIFICATIONS (Model 226 - continued) MILLIMETER INCH 226-81 Mounting & Dimensional Drawing 3

Conductivity range: analyzer minimum maximum 1056 and 56 15 us/cm 1500 ms/cm all others 200 us/cm 2000 ms/cm Wetted materials: option Process connection: wetted materials -02 and -03 glass-filled PEEK -04 glass-filled Tefzel -05 unfilled Tefzel -20 has EPDM gasket option connection -20 5/8-inch 11 UNC -21 3/4-inch MNPT SPECIFICATIONS (Model 228) Temperature and pressure: option temperature (max.) pressure (max.) -02 248ºF (120ºC) 295 psig (2135 kpa) -03 392ºF (200ºC) 295 psig (2135 kpa) -04 248ºF (120ºC) 200 psig (1480 kpa) -05 248ºF (120ºC) 200 psig (1480 kpa) Pressure (for CRN registration only): option pressure (max.) -02 220 psig (1618 kpa abs) -03 220 psig (1618 kpa abs) -04 150 psig (1135 kpa abs) -05 150 psig (1135 kpa abs) Cable length: 20 ft (6.1 m) Maximum cable length: 200 ft (61 m) Installation: Install the sensor so that it is completely immersed in the process liquid. Mounting in a vertical pipe run is best. If the sensor must be installed in a horizontal pipe run, place the sensor in the 3 o clock position. Weight/shipping weight: 2 lb/3 lb (1.0 kg/1.5 kg) (rounded up to nearest 1 lb or 0.5 kg) MILLIMETER INCH 5/8-11 UNC AMER STD UN THD DIA 30.48 1.20 3/4 MNPT 1 WRENCH OPENING 124.5 4.90 102.9 4.05 EPDM GASKET 10.80.425 DIA. THRU 37.6 1.48 DIA. 124.5 4.90 74.4 2.93 10.80.425 DIA. THRU 37.6 1.48 DIA. 18.8.74 18.8.74 17.0 CODE 20.67 CODE 21 17.0.67 3/4 FNPT 150.3 5.92 171.45 6.75 25.4 1.0 PEEK SUBMERSION ADAPTER P/N 33104-01 (FOR USE WITH CODE 20) TYPICAL THREAD CUTAWAY FOR CODE 20 PEEK FOXBORO ADAPTER P/N 23277-01 (FOR USE WITH CODE 20) FOXBORO 3/4 TRUNCATED PIPE THREAD STRAIN RELIEF BOOT Model 228 Dimensional Drawing 4

SPECIFICATIONS (insertion adapters for Model 228 sensor) Sensor compatibility: PN use with 23242-02 228-21 23242-03 228-20 2001990 228-21 Process connection: PN process connection 23242-02 1-1/2 inch MNPT 23242-03 1-1/2 inch MNPT 2001990 2 inch MNPT Wetted materials: PN wetted materials 23242-02 316 stainless steel, glass-filled PEEK, Viton 2 23242-03 316 stainless steel, glass-filled PEEK, Viton 2001990 CPVC, Viton Adapter PN 23242-02 use with 228-21 Temperature and pressure: PN temperature (max.) pressure (max.) 23242-02 392ºF (200ºC) 295 psig (2135 kpa abs) 23242-03 392ºF (200ºC) 295 psig (2135 kpa abs) 2001990 100ºF (38ºC) 185ºF (85ºC) Pressure (for CRN registration only): 100 psig (791 kpa abs) 45 psig (412 kpa abs) PN pressure (max.) 23242-02 220 psig (1618 kpa abs) 23242-03 220 psig (1618 kpa abs) Adapter PN 23242-03 use with 228-20 2001990 NA Installation: Install the sensor so that it is completely immersed in the process liquid. Mounting in a vertical pipe run is best. If the sensor must be installed in a horizontal pipe run, place the sensor in the 3 o clock position. Weight/Shipping weight: PN Weight Shipping Weight 23242-02 3 lb (1.5 kg) 4 lb (2.0 kg) 23242-03 3 lb (1.5 kg) 4 lb (2.0 kg) 2001990 1 lb (0.5 kg) 2 lb (1.0 kg) (rounded up to nearest 1 lb or 0.5 kg) 2Viton is a registered trademark of DuPont Performance Elastomers. Adapter PN 2001990 use with 228-21 5

SPECIFICATIONS (retraction assemblies for Model 228 sensor) Sensor compatibility: The retraction assemblies are used with 228-[ ]-20-54-62 only. Wetted materials: 316 stainless steel, EP rubber, unfilled Teflon 3, carbon-filled Teflon Process connection: 1-1/2 inch MNPT Temperature: 392ºF (200ºC) maximum Pressure: 295 psig (2135 kpa abs) maximum Maximum retraction/insertion conditions: PN description temperature pressure 23311-00 mechanical 392ºF (200ºC) 295 psig (2135 kpa abs) 23311-01 manual 266ºF (130ºC) 35 psig (343 kpa abs) Maximum insertion travel: PN description travel (max) 23311-00 mechanical 10.5 in (267 mm) 23311-01 manual 12.0 in (305 mm) Installation: Install the retraction assembly so that the sensor will be completely immersed in the process liquid. Weight/shipping weight: PN description weight/shipping weight 23311-00 mechanical 12 lb/15 lb (5.5 kg/7.0 kg) 23311-01 manual 9 lb/12 lb (4.5 kg/5.5 kg) (rounded up to nearest 1 lb or 0.5 kg) 3Teflon is a registered trademark of E.I. dupoint de Nemours and Co. SPECIFICATIONS (Ball valve PN 9340065 for use with Model 228 retraction assemblies) Wetted materials: 316 stainless steel, Teflon TFE Process connection: 1-1/2 inch FNPT Pressure and Temperature: See graph Weight/Shipping weight: 4 lb/5 lb (2.0 kg/2.5 kg) 6

SPECIFICATIONS (retraction assembly for Model 228 sensor) MILLIMETER INCH Manual Retraction Assembly 7

SPECIFICATIONS (retraction assembly for Model 228 sensor) cont. MILLIMETER INCH Mechanical Retraction Assembly 8

MODEL 226 TOROIDAL CONDUCTIVITY SENSOR The Model 226 Large Bore Submersion/Insertion Toroidal Conductivity Sensor is molded of chemically-resistant glass-filled PEEK. The sensor includes an integral RTD for temperature compensation and 20 ft of cable. The sensor is compatible with the 1056, 56, 54eC, 5081-T, 1066 and Xmt-T instruments. For improved EMI/RFI shielding, choose cable option -56. MODEL 226 LARGE BORE TOROIDAL CONDUCTIVITY SENSOR CODE BODY MATERIAL (required selection) 02 Glass-filled PEEK (Note 1) CODE CABLE (required selection) (Note 2) 54 Standard cable 56 Cable with additional shielding for improved EMI/RFI protection (Note 3) CODE MOUNTING OPTIONS (required selection) 80 Submersion (see mounting and dimensional drawing) 81 Insertion through flange (see mounting and dimensional drawing) 82 No mounting kit 226-56 -56-82 EXAMPLE -82 EXAMPLE NOTES: 1. The sensor is supplied with an EPDM gasket. A Viton gasket is available as PN 33151-01. 2. Cables can be extended using the remote junction box PN 23550-00. See also EXTENSION CABLE on page 11. 3. Option 56 cable is recommended for use with the 1056, 56, 54eC, 5081-T, 1066, and Xmt-T instruments. ACCESSORIES (MODEL 226 SENSOR) PART NUMBER DESCRIPTION 2001492 Stainless steel tag, specify marking 23550-00 Remote junction box 33151-00 Gasket, EPDM 33151-01 Gasket, Viton 33185-01 Mounting adapter, submersion, 3-in length, 1-in MNPT, PEEK (spare for 226-80) 33185-02 Mounting adapter, flange insertion, 1-in length, PEEK (spare for 226-81) 33219-00 7/8-in 9 UNC X 1-in MNPT for conduit connection, (spare for 226-81) 9

MODEL 228 TOROIDAL CONDUCTIVITY SENSOR The Model 228 Submersion/Insertion Toroidal Conductivity Sensor is molded of chemically-resistant PEEK (glass-filled) or Tefzel (glass-filled or unfilled). The sensor includes an integral RTD for temperature compensation. The sensor is compatible with the 1056, 56, 54eC, 5081-T, 1066 and Xmt-T instruments. For improved EMI/RFI shielding, choose cable option -56. MODEL 228 INSERTION/SUBMERSION TOROIDAL CONDUCTIVITY SENSOR CODE BODY MATERIAL (required selection) 02 Glass-filled PEEK, standard temperature to 248ºF (120ºC) 03 Glass-filled PEEK, high temperature to 392ºF (200ºC) 04 Glass-filled Tefzel, standard temperature to 248ºF (120ºC) (not available with code 54-62) 05 Unfilled Tefzel, standard temperature to 248ºF (120ºC) (not available with code 54-62) CODE PROCESS CONNECTION (required selection) 20 5/8-in 11 UNC, requires mounting adapter (Note 1) 21 3/4-in MNPT (not available with code -62) CODE CABLE (required selection) (Note 2) 54-61 Standard integral cable, 20 ft 56-61 Integral cable with additional shielding for improved EMI/RFI protection, 20 ft (Note 3) 20-inch (508 mm) cable for connection to junction box used in retraction assembly. Requires extension 54-62 cable from junction box to analyzer. (Note 4) 228-02 -21-56 -61 EXAMPLE NOTES: 1. The sensor is supplied with an EP gasket. Viton (PN 33075-00) and Kalrez (PN 33075-03) gaskets are also available. 2. Cables can be extended using the remote junction box PN 23550-00. See also EXTENSION CABLE on page 11. 3. Option 56-61 cable is recommended for use with 1056, 56, 54eC, 5081-T, 1066, and Xmt-T instruments. 4. Choose either cable 23294-00 or 23294-04. Cable 23294-04 has more EMI/RFI shielding and is recommended for use with the 1056, 56, 54eC, 5081-T, 1066, and Xmt-T instruments. ACCESSORIES (MODEL 228 SENSOR) PART NUMBER DESCRIPTION 2001492 Stainless steel tag, specify marking 23550-00 Remote junction box 2001990 Mounting adapter, 2-in MNPT, CPVC for use with 228-21 (see drawing) 23242-02 Mounting adapter, 1-1/2 in MNPT, PEEK, for use with 228-21 (see drawing) 23242-03 Mounting adapter, 1-1/2 in MNPT, PEEK, for use with 228-20 (see drawing) 23277-01 Mounting adapter, Foxboro, PEEK, 5/8 11 UNC, for use with 228-20 23277-01 SQ7182 Mounting adapter, Foxboro, Tefzel, 5/8 11 UNC, for use with 228-20 23311-00 Retraction assembly, mechanical, for 228-20-54-62 only 23311-01 Retraction assembly, manual, for 228-20-54-62 only 33075-00 Gasket, Viton, for 228-20 33075-01 Gasket, EPDM, for 228-20 33075-03 Gasket, Kalrez, for 228-20 10

ACCESSORIES (MODEL 228 SENSOR Continued) PART NUMBER DESCRIPTION 33081-00 SQ7091A Adapter insert, Tefzel, for 23242-02 33080-01 SQ7091B Adapter insert, Tefzel, for 23242-03 33104-01 Submersion adapter, PEEK, for 228-20 9340065 Ball valve, full port, 1 1/2 inch FNPT for 23311-00 and 23311-01 9550179 O-ring, EP rubber, for 2001990 EXTENSION CABLE All extension cable is terminated at both ends. PN Description 23294-00 Interconnecting cable for use with 226-54 and 228-54 sensors 23294-04 Interconnecting cable for use with 226-56 and 228-56 sensors. Cable has more EMI/RFI shielding than 23294-00, and is recommended for use with 1056, 56, 54eC, 5081-T, 1066, and Xmt-T instruments. 23294-05 Interconnecting cable for use with 228-03-56-61 (high temperature) sensors. Cable has more EMI/RFI shielding than 23294-00. ENGINEERING SPECIFICATION FOR MODEL 226 SENSOR 1. The sensor shall measure electrolytic conductivity using the inductive or toroidal method. 2. The sensor shall have a large bore to reduce fouling from fibrous materials in the process stream. 3. The sensor shall be molded from glass-filled PEEK. 4. The sensor shall be suitable for submersion mounting or for insertion mounting through a pipe flange. 5. The sensor shall withstand 248ºF (120ºC) at 295 psig (2135 kpa). 6. The sensor shall be Rosemount Analytical Model 226 or approved equal. ENGINEERING SPECIFICATION FOR MODEL 228 SENSOR 1. The sensor shall measure electrolytic conductivity using the inductive or toroidal method. 2. The sensor shall be molded from glass-filled PEEK, glass-filled Tefzel, or unfilled Tefzel. 3. The sensor shall be suitable for submersion mounting using a 3/4 inch MNPT, insertion through a pipe flange using a 5/8 inch 11 UNC thread, or insertion through an adapter. Insertion adapters shall have 1-1/2 inch MNPT connections. 4. The glass-filled PEEK sensor shall withstand 248ºF (120ºC) at 295 psig (2135 kpa). A high temperature glassfilled PEEK sensor that can withstand 392ºF (200ºC) at 295 psig (2135 kpa) shall also be available. The Tefzel sensor shall withstand 248ºF (120ºC) at 200 psig (1480 kpa). 5. The sensor shall be Rosemount Analytical Model 228 or approved equal. 11

COMPATIBLE ANALYZERS AND TRANSMITTERS The Model 1056 Dual Input Analyzer offers the choice of single or dual sensor inputs in any combination of ph/orp, contacting and toroidal conductivity (resistivity), chlorine, oxygen, and ozone. High purity water, percent slope, and cation conductivity temperature corrections are standard for the conductivity measurement. Conductivity readings can also be converted to TDS, % concentration, ratio, and % rejection. The large backlit display is easy to read and can be customized to fit user requirements. Diagnostic variables to aid in troubleshooting are displayed at the touch of a button. The analyzer has two fully programmable analog outputs. Programming and calibrating is so simple and intuitive that a manual is almost not necessary The Model 5081 Conductivity Transmitter and an Endurance Conductivity Sensor can be used to monitor conductivity or resistivity in a variety of processes. The Model 5081 uses state-of-the-art microprocessor technology. Two digital communication protocols are available: HART and Foundation Fieldbus. Digital communications allows access to AMS (Asset Management Solutions). Use AMS to set up and configure the transmitter, read process variables, and troubleshoot problems from a personal computer or host anywhere in the plant. A handheld infrared remote controller or the HART Model 275 communicator can also be used for programming and calibrating the transmitter. The remote controller works from as far away as six feet.the user-friendly menus of the Model 5081 (Calibrate/Program/ Diagnose), coupled with descriptive headers and prompts, almost eliminate the need for an instruction manual. The Model 56 Analyzer can be used with any ENDURANCE family conductivity sensor to measure electrolytic conductivity in a variety of applications. The Model 56 can be set up as either a dual input conductivity analyzer, or the second input can be connected to a ph, ORP, chlorine, oxygen, ozone, or turbidity sensor. The analyzer has four fully programmable analog outputs and four fully programmable alarm relays, including PID and TPC control. The high contrast, full color display shows measurement results in large, easy-to-read digits. Menu screens for programming and calibration are simply and intuitive. Information screens, offering detailed explanation of programming features and calibration methods as well as troubleshooting assistance, are available at the touch of a button. An event and data logger and a dual graphical display are also standard. HART and Profibus DP digital communication are optional. The Solu Comp Model Xmt-C Conductivity Transmitter can be used with most ENDURANCE conductivity sensors. The transmitter has a two-line display. Menu screens for calibrating and configuring are simple and intuitive. Plain language prompts guide the user through the procedures. Two digital communication protocols are available: HART (model option -HT) and FOUNDATION fieldbus (model option -FF). Digital communications allow access to AMS (Asset Management Solutions). Use AMS to set up and configure the transmitter, read process variables, and troubleshoot problems from a personal computer or host anywhere in the plant.the keypad allows local programming and calibrating of the transmitter. The HART Model 375 communicator can also be used for programming and calibrating the transmitter. All Rosemount Analytical Conductivity Instruments feature automatic temperature correction for high purity water and cation conductivity. Programmable percent change per C temperature correction is also available. The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2011