Toroidal Conductivity Sensor

Similar documents
Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017

For additional information, please visit our website at SENSOR SPECIFICATIONS

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.b February 2011

Endurance TM Conductivity Sensors

Conductivity Sensors. Model 140, 141, 142. Product Data Sheet series/rev.a June 1998

Conductivity Sensors. Applications. 140 Series Conductivity Sensors Product Data Sheet LIQ_PDS_140_141_142_Conductivity_Sensors January 2014

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.G February 2006

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.I December 2008

Rosemount 402 and 402VP

ENDURANCE. Sanitary Flange Conductivity Sensors. Models 403 and 403VP. Product Data Sheet PDS /rev.A June 2005

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.K February 2013

Conductivity Sensors. Applications

General Purpose Conductivity Sensors ENDURANCE. Model 400 and 400VP Series. Product Data Sheet PDS /rev.J January 2011

General Purpose Toroidal Conductivity Sensors

Insertion/Submersion Flow Through Sensor

General Purpose ph/orp Sensors

Rosemount 228. Toroidal Conductivity Sensor. Product Data Sheet July Series LIQ-PDS-228

NEW QUICK CABLE-TO-SENSOR RELEASE,

ph/orp Sensor Model 399 ph/orp

Models 396/396P/396R. Retraction/Submersion/Insertion ph/orp Sensor

General Purpose ph/orp Sensors

Rosemount TM 242 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-242 Rev. F June 2017

ENDURANCE Conductivity Sensors

Analytical Instruments Two-Electrode Conductivity Sensors

Instruction Manual PN /rev.C June Models 140, 141, 142. Conductivity Sensor Assemblies

Powers Controls TT 184 Temperature Transmitters

Pasve Rotary Retraction Valve

Dissolved Oxygen, ph, and Conductivity

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

TUpH Retraction/Submersion/Insertion ph/orp Sensors

Model Q45H/ Residual Chlorine Monitor...

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

V550 Spring Lock Flanged Connection with Packing Gland

Dissolved Oxygen Measurement System with Air Blast Cleaner

SIGNET 2760 DryLoc ph/orp Preamplifier

Rosemount 485 Annubar Flanged Assembly

Type 80 Wafer and Type 81 Bolt-Thru Isolation Rings. Installation, Maintenance and Safety Instructions

Retractable ph/orp Sensors

Retractable ph/orp Sensors

Electronic Temperature Sensor

Instruction Manual PN /rev.C May Model 242. Flow-Through Toroidal Conductivity Sensor

Rosemount 1195 Integral Orifice Primary Element

High Purity ph Sensor

Retractable ph/orp Sensors

COMBINATION ph SENSOR

V200S. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double (150mm-1050mm)

Signet Conductivity/Resistivity Electrodes

Instruction Manual PN /rev.H March Model 385+ ph/orp Sensor

Liquid Conductivity Two & Four Electrode Sensors

Regular Models. V150 Spring Lock Threaded Components

Type 80 Wafer and Type 81 Bolt-Thru Isolation Rings. Installation, Maintenance and Safety Instructions I&M /14

Model Specifications V400S V400D Sensor Code Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

Retractable ph/orp Sensors

Sanitary Sensors. High Quality, Precision. Sanitary Sensors. THORNTON Leading Pure Water Analytics

Signet Conductivity/Resistivity Electrodes

Model 385+ Instruction Manual PN February ph/orp Sensor

Temperature: TYPE A (1" 3") TYPE B (1/2" TYPE C (1/2" 4") TYPE D (3"

Rosemount 285 Annubar Pak-Lok Assembly

F-2600 SERIES INLINE VORTEX FLOW METER

Rosemount 405 Compact Orifice Series

KDM ARMORED FLOW METER & SWITCH

Model Instruction Manual P/N January Conductivity Sensors

Rosemount 285 Annubar Primary Element Series

Installation for Porsche 911 PN

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Exhaust System Installation for Nissan GT-R PN 12658

ABB MEASUREMENT & ANALYTICS DATA SHEET. AC200 Series Industrial 2-electrode conductivity cells with rapid temperature response

INSTALLATION TROUBLESHOOTING SUPPLEMENT

Mid-Pipe & Rear Section Installation for KIA Soul

Installation for Chevrolet Corvette C7 Stingray PNs 60547* 60548, and 60558

Constant Flow Valves. Specifications PVC: 1/2", 3/4", 1", 2", 3", 4" PVC PVC Flanged ANSI EPDM Stainless Steel 304 with ETFE Coating º F

Installation for Dodge Charger R/T PN s , ,

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

LTX RF LEVEL SENSOR. Instruction Manual

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Combination ph/orp Sensor

F-2700 SERIES INSERTION VORTEX FLOW METER

Combination ph/orp Sensor

Triple Junction ph/orp Sensor

Instruction Manual PN /rev.D September 2009 Model 385. Retractable ph/orp Sensor

Accessories Guide ph/orp/conductivity Sensors

381+ Rebuildable ph Sensor. Instruction Manual LIQ_MAN_381+ January 2013

Constant Flow Valves. Specifications Sizes: PVC: 1/2", 3/4", 1", 2", 3", 4" CPVC: 1" and 2" Body: Bonnet: Models: Seals: Springs:

F-2600 SERIES INLINE VORTEX FLOW METER

Installation for Ford Explorer PN s , ,

Cat-Back Exhaust Installation , , ,

Exhaust System Installation for Toyota Tacoma PN s , , ,

RESISTIVITY MONITOR/CONTROLLERS

Installation, Operation and Maintenance Manual for Flame Check

, General Instructions for Handling and Installation of Rosemount 1199 Seal Systems

Rosemount Integral Orifice Flowmeter Series

Instruction Manual PN /rev.G March 2012 Model 381+ ph/orp Sensor

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Rosemount 485 Annubar Pak-Lok Assembly

OPERATING INSTRUCTION MANUAL MS SERIES CONDUCTIVITY CELLS

TRANSMITTER ATTACHES TO THIS SURFACE

Triple Junction Sensor

TORQUE TRANSDUCER TMHS-*NM (for Torque Transducer) Instruction Manual. MinebeaMitsumi Inc. Sensing Device Business Unit

Transcription:

Instruction Sheet PN 51A-222/rev.A January 2011 Model 222 Toroidal Conductivity Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. SPECIFICATIONS Wetted Materials: Teflon-lined carbon steel pipe, with carbon steel outer flanges. Option-21 has 316 SS outer flanges. Temperature and Pressure: Flange Option Temperature Pressure 150 lb -01 and -02 360 F (182 C) 125 psig (963 kpa abs) 300 lb -05 and -06 360 F (182 C) 250 psig (1825 kpa abs) Outside flanges: ANSI B16.5 raised face, threaded INSTALLATION First, decide whether the initial calibration will be done in the shop before installing the sensor or in the process piping after installing the sensor. Refer to the Calibration section for information about in-shop and in-process calibrations. NOTE Install the sensor in a location where it will be completely filled with process liquid. A vertical pipe run with the flow from bottom to top is best. 1. Remove the grounding strap from the outer flanges. See Figure 1. Save the strap and all the hardware for reassembly. 2. Carefully remove the nuts, bolts, insulating bushings, and washers from the flanges. Save the parts. They will be needed later and must be in good condition. Separate the flange sets. 3. Remove and save the flange gaskets. 4. Install the outer flanges on the process piping, observing the dimensions noted in Figures 2 and 3. Use pipe joint compound or pipe tape to ensure the connections do not leak. 5. Install a ½ inch FNPT thermowell in the process piping within 6 ft. (1.8m) of the sensor. For best results place the thermowell as close as possible to the sensor. 6. Position the sensor between the process mating flanges with the flange gaskets inserted between each set of flanges. If the process piping is lined with a non-conductive material, a metal orifice plate (contact ring) must be installed between the flanges. Consult the factory for more information. 7. Align the bolt holes. 8. Insert an insulating sleeve in each bolt hole. See Figure 1. 9. Place a metal washer on each bolt, followed by an insulating washer. Insert the bolt through the insulating sleeve. 10. Place an insulating washer followed a metal washer on each bolt.

INSTALLATION NOTE Before tightening the bolts (step 11), be sure the flange gaskets are installed between the system piping and the sensor and that the insulating sleeves and washers are in place. For the sensor to operate properly there must no metal to metal contact between the sensor and the process piping. 11. Screw a nut onto each bolt and tighten according to the table. Follow the torquing sequence shown in Figure 1. Flange Torque 1 inch flange bolts 10 ft-lb (7.37 N-m) 2 inch flange bolts 25 ft-lb (18.43 N-m) Do not over tighten the bolts. 12. Connect the grounding strap between the two outer flanges using the screws and washers removed in step 1. If an orifice plate contact ring is being used, connect the shorting strap to the two contact rings. 13. Install the temperature sensor in the thermowell. Use Teflon tape on the pipe threads. The insertion length is adjustable from 1.4 to 4.0 inches (36 to 102 mm). The temperature sensing zone, which extends 1.3 inches (33 mm) from tip of the sensor, must be inside the thermowell DWG. NO. REV. 40022208 D FIGURE 1. Model 222 Toroidal Conductivity Sensor/Assembly Installation 2

INSTALLATION MILLIMETER INCH Model 222-01 Model 222-02 DWG. NO. REV. 40022210 A DWG. NO. REV. 40022211 B FIGURE 2. Code-01 and -02 Dimensions 3

INSTALLATION MILLIMETER INCH Model 222-05 Model 222-06 DWG. NO. REV. 40022212 A DWG. NO. REV. 40022213 B FIGURE 3. Code-05 and -06 Dimensions 4

WIRING WIRING Keep sensor wiring away from ac conductors and high current demanding equipment. Do not cut cable. Cutting the cable may void the warranty. FIGURE 4. Wire Functions 222 FIGURE 5. Wiring 222 sensor to Model 1056 and 56 analyzers 222 FIGURE 6. Wiring 222 sensor to Model 54eC analyzer 5

WIRING 222 FIGURE 7. Wiring 222 sensor to Model Xmt-T panel mount transmitter 222 FIGURE 8. Wiring 222 sensor to Model Xmt-T pipe/wall mount transmitter TB2 TB1 RTN RCV B SENSE RCV A RTD IN SHLD RSHLD DRV B DRV A GREEN WHITE CLEAR BLACK GREEN BLACK WHITE DSHLD 228-54 222 FIGURE 9. Wiring 222 sensor to Model 1066 transmitter 222 FIGURE 10. Wiring 222 sensor to Model 5081-T transmitter 6

MODEL 228 WIRING WIRING THROUGH A REMOTE JUNCTION BOX 222 FIGURE11. Wiring sensor through a remote junction box Wire cable point to point. For wiring at the analyzer end, refer to the appropriate analyzer wiring diagram. FIGURE 12. Remote Junction Box (PN 23550-00) 7

CALIBRATION CALIBRATION The nominal cell constant of the 1-inch diameter sensor is 6/cm and the nominal cell constant of the 2-inch diameter sensor is 4/cm. The error in the cell constant is about ±10%, so conductivity readings made using the nominal cell constant will have an error of at least ±10%. For higher accuracy the sensor must be calibrated. The sensor can be calibrated using a standard solution or a previously calibrated sensor and analyzer. Calibration against a standard solution requires that the sensor and outer flanges be removed from the process piping. Generally it is a useful method only when the sensor is first installed. Otherwise, the sensor should be calibrated in place against a referee sensor and analyzer. To calibrate against a standard solution, screw a short length of metal pipe into one of the outer flanges and cap the open end of the pipe. Stand the sensor on the capped end and fill it with standard to the level of the upper surface of the second outer flange. Be sure the shorting strap is connected to both flanges. Adjust the analyzer reading to match the known conductivity of the standard. Do not place a temperature sensor or any object inside the conductivity sensor during calibration. Doing so will alter the measured conductivity and introduce an error in the measurement. Once the sensor has been installed in the process piping, removing it for calibration is impractical. In this case, calibrate the sensor against a referee sensor and analyzer, ideally while both sensors are simultaneously measuring the same process liquid. If this is not practical, calibrate the sensor against the results of a measurement made on a grab sample. For more information about calibrating toroidal conductivity sensors, particularly precautions to take during in-process calibrations, refer to application sheet ADS 43-025, available on the Rosemount Analytical website. 8

TROUBLESHOOTING TROUBLESHOOTING PROBLEM PROBABLE CAUSE SOLUTION Off-scale reading Wiring is wrong. RTD is open or shorted. Sensor is damaged. Noisy reading Fluctuating process liquid level in the sensor. Sensor cable is run near high voltage conductors. Sensor cable is moving. Verify and correct wiring. Check RTD for open or shorts. See Figure 13. Perform isolation checks. See Figure 13. Perform toroid check. Confirm that the sensor is installed in the process piping so that it is always filled with liquid. Installation in a vertical pipe run with flow from the bottom is best. Move the cable away from high voltage conductors. Keep the sensor cable stationary. Reading seems wrong (lower or higher than expected) Bubbles are trapped in the sensor Sensor is not completely filled with process liquid. Cell constant is wrong. Wrong temperature correction algorithm is being used. Temperature reading is inaccurate. Measured temperature does not match temperature at the sensor. Toroids are damaged. Increase the flow if possible. Confirm that the sensor is installed in the process piping so that it is always filled with liquid. Installation in a vertical pipe run with flow from the bottom is best. Calibrate the sensor. Check that the temperature correction is appropriate for the sample. See analyzer manual for more information. Disconnect the RTD leads (Figure 13) and measure the resistance between the in and common leads. The resistance should be close to the value in Table 1. Move the thermowell and RTD closer to the sensor. Perform toroid check. 9

TROUBLESHOOTING FIGURE 13. Disconnect wires from analyzer before measuring resistance. TABLE 1. Temperature Resistance 10 C 103.9 Ω 20 C 107.8 Ω 25 C 109.7 Ω 30 C 111.7 Ω 40 C 115.5 Ω 50 C 119.4 Ω Checking toroid operation Use the following procedure to check the operation of the toroids. 1. Disconnect the shorting strap from one of the outer flanges. The conductivity reading will drop to zero. 2. Pass a short piece of heavy gauge wire through the space between the toroid assembly and the pipe. 3. Connect the ends of the wire to a resistance decade box. 4. Turn off temperature correction in the analyzer. If raw conductivity is available as a temperature compensation selection, choose raw. If raw is not available, choose manual temperature correction and set the temperature to 25 C (77 F). 5. Adjust the resistance to the values shown in the table below. The conductivity reading displayed by the analyzer should be close to the values shown. Resistance 1-inch sensor K = 6/cm 2-inch sensor K = 4/cm 100 Ω 60 ms/cm 40 ms/cm 200 Ω 30 ms/cm 20 ms/cm The toroids are working properly if increasing the resistance by a factor of two causes the displayed conductivity to decrease by a factor of two. 10

MAINTENANCE REPLACEMENT PARTS PN Description 2002557 Insulation kit, 1 inch, 150 lb flange, 2 sets (See Note) 2002558 Insulation kit, 1 inch, 300 lb flange, 2 sets (See Note) 2002559 Insulation kit, 2 inch, 150 lb flange, 2 sets (See Note) 2002560 Insulation kit, 2 inch, 300 lb flange, 2 sets (See Note) 8950101 Pt 100 RTD assembly 23294-00 Interconnecting cable, specify length (maximum 100 ft (30.5m)) Note: Each insulation kit contains two flange gaskets and sufficient insulating sleeves, insulating washers, and stainless steel washers to replace both flange seals of one sensor. The kit does not contain flange bolts or nuts. 11

The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com 8 Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com Rosemount Analytical Inc. 2011