Translation from the German original, not verified by the Deutsches Institut für Bautechnik. Zulassungsstelle für Bauprodukte und Bauarten

Similar documents
Z from: 1 November 2016

English translation authorized by DIBt Original version in German language

General Technical Approval

EEA AGREEMENT - ANNEX XIII p. 99 APPENDIX 2 { 1 }

Section 1 Scope of application

Modulares Rigolensystem für die Versickerung von Niederschlagswasser mit der Bezeichnung "ACO Stormbrixx"

Certification Scheme

KBA Kraftfahrt-Bundesamt

Sound-absorbing spacer Sorp10

ANNEX MOTOR VEHICLES AND MOTOR VEHICLES' PARTS. Article 1. General Provisions

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen

European Technical Assessment ETA-13/0900 of 10/04/2014

SFI SPECIFICATION 39.2 EFFECTIVE: August 25, 2017 *

Keymark Conference. Demands of Mineral Wool Manufacturers

Classification report No K1

ANNEX MOTOR VEHICLES AND EQUIPMENT AND PARTS THEREOF. Article 1. Definitions

Broetje-Automation Company Standard Structural component specification for welded parts

PETROLEUM PRODUCTS INSPECTION OPERATIONS MANUAL

Polymeric membrane for roof waterproofing. Uses Roof waterproofing membrane for exposed flat roofs: Loose laid and mechanically fastened

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

EU-Mexico Free Trade Agreement EU TEXTUAL PROPOSAL

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

(Text with EEA relevance)

INDUSTRIAL HAUL AGREEMENT

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

PTV TECHNICAL PRESCRIPTIONS. ELASTOMERIC SEALS: Part 1: Vulcanized Rubber FOR. Impartial institute for the monitoring of construction products

SFI SPECIFICATION 49.2 EFFECTIVE: MARCH 22, 2011 *

DEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

European Technical Assessment ETA-09/0355 of

NSAI Licensed Adaptor Scheme. Guidance Document for. Individual Vehicle Approval (IVA)

Product Evaluation Report

ISO INTERNATIONAL STANDARD

CITY OF SALEM, ILLINOIS ALTERNATIVE TRANSPORTATION APPLICATION AND INSPECTION REPORT (GOLF CARS) Applicant Name:

Sarnafil TS E. Polymeric membrane for roof waterproofing. Product Description

COMMISSION REGULATION (EU) / of XXX

Guideline of the Railway Vehicles Coordination Committee (Draft Guideline DVS 1619)

E/ECE/324/Rev.2/Add.112/Rev.3/Amend.6 E/ECE/TRANS/505/Rev.2/Add.112/Rev.3/Amend.6

European Technical Approval ETA-10/0198

SFI SPECIFICATION 4.2 EFFECTIVE: OCTOBER 26, 1994*

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

- 2 - Holders of foreign driving licences who have taken up employment in the Federal Republic of Germany but only return to the family residence they

Diesel Exhaust Fluid Certification Program Overview FEBRUARY 2009 REVISION 01

Certification Scheme

Operating Instructions Inline Detonation Flame Arrester and

Information for the Certification of Weld Shops in Rail Vehicle Construction According to DIN EN

Safety Assessment & Approval System of Shanghai Maglev Demonstration Line and its Practice

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

VITLAB Dispenser. Standard Operating Procedure (SOP)

TOWNSHIP OF RARITAN COUNTY OF HUNTERDON, NEW JERSEY ORDINANCE #16-06 REVISED

CertRom. BUCHAREST, S5 Calea 13 Septembrie 231A; Ph: , Fax: ;

GREATER VANCOUVER SEWERAGE AND DRAINAGE DISTRICT BYLAW NO. 307, A Bylaw to License Commercial Waste Haulers

City of San Juan Capistrano Agenda Report

Obtaining ASTM D6400- D6868 Approval

SFI SPECIFICATION 15.2 EFFECTIVE: MAY 1, 2008 *

QUESTION / CLARIFICATION

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

Electric Vehicle Charging Station Incentives PROGRAM HANDBOOK

SFI SPECIFICATION 6.1 EFFECTIVE: FEBRUARY 26, 2014 *

Instruction Manual. Ex-Time 40 / 50

PUR-O-STOP FS-L. General Building Inspectorate Approval for curtain grouting CE-marking in accordance with EN

Land Transport Rule Traction Engines [2008]

High Performance Axial Fans

UNIGLAS Tender Specifications

Practice Note on the Sourcing of Threaded Rod Used for Foundation Bolts

ELECTRICAL DISTRICT # 2

SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines

CITY COUNCIL OF THE CITY OF NOVATO ORDINANCE NO. 1620

A Guide to the Carriage. by Road of Detonators. with Blasting Explosive Substances

SFI SPECIFICATION 7.2 EFFECTIVE: DECEMBER 15, 2006 *

CE DECLARATION OF CONFORMITY

BMW of North America, LLC, Grant of Petition for Decision of. AGENCY: National Highway Traffic Safety Administration (NHTSA),

RALEIGH COUNTY ALL-TERRAIN VEHICLES (ATV) ORDINANCE

Deutsche Akkreditierungsstelle GmbH

ORDINANCE NO WHEREAS, the City Council wishes to advance the use of electric vehicles; and

Bourdon tube pressure gauge, copper alloy Panel mounting series Models and

City of Ely Golf Cart/ATV Registration

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies

Report Test Report

ECOMP.3.A EUROPEAN UNION. Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 ENT 229 MI 914 ENV 837 AGRI 596 PREP-BXT 58 CODEC 2164

Assessment Report. Stanley Black & Decker Deutschland GmbH Richard-Klinger-Str Idstein

E/ECE/324/Add.5/Rev.6/Amend.2 E/ECE/TRANS/505/Add.5/Rev.6/Amend.2

Certificate: _01 / 29 April 2014

SFI SPECIFICATION 15.4 EFFECTIVE: JULY 20, 2010 * PRODUCT: Top Fuel and Funny Car Drag Race Drive Beadlock Wheels

ANSI/AGRSS Automotive Glass Replacement Safety Standard

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

TITLE 280 DEPARTMENT OF REVENUE 2.1 PURPOSE 2.2 AUTHORITY 2.3 APPLICATION 2.4 SEVERABILITY 2.5 DEFINITIONS 280-RICR

(Acts whose publication is not obligatory) COUNCIL COUNCIL DIRECTIVE

Certificate: / 22 March 2013

MINISTRY OF TRANSPORT, INFRASTRUCTURE, HOUSING, URBAN DEVELOPMENT AND PUBLIC WORKS

SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *

Information Sheet. concerning the Issuing of Multi-stage Typeapprovals in accordance with Directive 2007/46/EC (MMT) Version: March 2016.

Road Transport Act 1

QUESTIONS & ANSWERS. Q1: Why does EASA not simply mandate accomplishment of a Service Bulletin (SB)?

Carbon Intensity Records under the Renewable and Low Carbon Fuel Requirements Regulation

AIIPA Standardized Best Practices Recommendations

Operating Instruction Inline Detonation Flame Arrester

7 The revised IS 8034:2002 and revised STI be implemented w.e.f. 1 Feb 2005.

Kraftfahrt-Bundesamt. Guideline for the test of conformity of vehicles in operation in connection with the EC type approval (exhaust emission)

Transcription:

Allgemeine bauaufsichtliche Zulassung () Zulassungsstelle Bauprodukte und Bauarten Bautechnisches Prüfamt Eine vom Bund und den Ländern gemeinsam getragene Anstalt des öffentlichen Rechts Member of EOTA and UEAtc Our ref.: Date: April 18, 2012 III 41-1.56.2-65/11 Approval number: Z-56.28-3564 Valid until: April 18, 2017 Applicant: Akzo Nobel Wood Coatings GmbH Geschäftsbereich Zweihorn Düsseldorfer Straße 96-100 40721 Hilden Object of approval: Three-layer paint system "Wigranit " on MDF boards with fire behaviour B- s2, d0. The above-mentioned object of approval is hereby provided with the. This consists of six pages. Kolonnenstraße 30 B D-10829 Berlin Tel.: +4930 78730-0 I Fax: +49 3078730-320 I E-Mail: dibt@dibt.de I www.dibt.de

Page 2 of 6 April 18, 2012 I GENERAL PROVISIONS 1 The proves the usability and/or applicability of the object of approval for the purpose of the State Building Laws. 2 As far as the should put demands on particular competence and experience of the persons entrusted with the manufacturing of construction products and building elements according state regulations equivalent to Art. 17 Par. 5 of the Model Building Regulation, it must be considered, that this competence and experience can also be proved by equivalent proofs of other member states of the European Union. This also applies to equivalent proofs provided under the Agreement on the European Economic Area (EEA) or other bilateral agreements. 3 The does not replace the legally required approvals, consents and certificates necessary for the execution of building projects. 4 The is granted irrespective of the rights of third parties, especially of private proprietary rights. 5 Irrespective of other regulations in the section "Special Provisions", manufacturers and sellers of the object of approval have to provide the user of the object of approval with copies of the and have to point out that the must be available at the place of application. Upon request, the authorities concerned must be provided with copies of the. 6 The may only be duplicated completely. Any publication in extracts requires the approval of the. Texts and drawings in leaflets may not be inconsistent with the. Translations of the General must be marked with "Translation from the German original, not verified by the ". 7 The is granted revocably. The provisions of the may be completed or changed subsequently, especially if this should be required due to new technical findings. Seal of

Page 3 of 6 April 18, 2011 II SPECIAL PROVISIONS 1 Object of Approval and Range of Application 1.1 Object of Approval The applies to the manufacturing and application of the three-layer paint system "Wigranit" applied to one side of an MDF board (henceforth referred to as "coated MDF board") with the fire behaviour Class C-s1,d0 according to DIN EN 13501-1 1,2, but only on a MDF board with a gross density of 790 kg/m 3, a thickness of 19 mm and a fire behaviour of class B-s2,d0. (Class C-s1,d0 corresponds to the general technical designation "flame-resistant".) 1.2 Range of Application 1.2.1 The coated MDF board according to DIN EN 13986 3 and Par. 2.1 may be used for interior constructions of wall and ceiling finishes. It may also be applied as top layer of suspended ceilings according to the standard DIN EN 139 64 4 and must meet the requirements of that standard. It may be mounted with metal fixtures on metal supporting structure elements. The distance to the same or other flat construction products must be 80 mm. The joints between the coated MDF boards must be butt joined or closed by means of metal joint profiles. 1.2.2 Irrespective of this, components and special components in which the coated MDF board is used require in proof of their standard of fire resistance separate regulations (depending on the component, e.g., a General Appraisal Certificate or a General Technical Approval). The provisions concerning the coated MDF board contained in these proofs must be taken into account. 1.2.3 When using the coated MDF board for components in load-bearing or stiffening function (e.g., as load-bearing or stiffening covering), the provisions of the Building Rules List B, Part 1, cons. No. 1.3.2.2 must be taken into account. In normal case, dimension is made in accordance with the standards DIN 1052 5 combined with DIN V 20000 6 or DIN V ENV 1995-1 -1 7 together with the national application document 8. 1 DIN EN 13501-1 :2010-01 Fire classification of construction products and building elements - Part 1: Classification using data from reaction to fire tests 2 Note: Please note that the classification in a construction product class according to DIN EN 13501-1 is a preliminary decision in default of a harmonized European decision. Future harmonized product specifications may define deviating test requirements, which may require re-testing. 4 DIN EN 13964:2007-02 und A1 :2006 Suspended ceilings - Requirements and test methods 5 DIN 1052:2008-12 Design, calculation and dimensioning of timber structure - General rules and rules for buildings. Revision l:2010-05 must be taken into account. 6 7 DIN V 20000-1:2005-12 DIN V ENV 995-1-1:1994-06 Application of construction products in structure - Part 1: Wood based panels Eurocode 5 - Design, calculation and dimensioning of timber structure; General rules and rules for buildings 8 National Application Document (NAD) "Directive concerning the application of DIN V ENV 1995-1-i ", Edition February 1995 Seal of

Page 4 of 6 April 18, 2012 1.2.4 This does not govern the suitability of the coated MDF board for purposes, which are subject to requirements concerning heat or sound insulation. 1.2.5 Fire behaviour is not attested if the surface of the MDF board coated on one side is additionally coated with paints, laminations or similar. 1.2.6 After the evidence of the smoulder behaviour of the coated MDF board in the fire shaft according to DIN 4102-1 9, has been provided, it may be used as flame-resistant building material. 2. Building Product Requirements 2.1 Properties and Composition 2.1.1 The MDF board (untreated board) must meet the requirements of the DIN EN 13986 standard and must have a thickness of 19 mm, a gross density of at least 790 kg/m 3 and a fire behaviour of at least B-s2,d0. The untreated board may be coated with a three-layer paint system consisting of Wigranit Isolierfüller Two-Pack Insulating Filler WIG-IF wet film thickness:</= 250 g/m² Wigranit Novacolor WNC/Colour, wet film thickness:</= 130 g/m² and Crystallit Two-Pack Solvent-Based Varnish CL wet film thickness:</= 120 g/m² on one side. When doing so, the individual constituent parts of the system in different mixing ratios are mixed with the Hardener S8888 (WIG-IF) and PUR 5085 (WNC and CL) according to the manufacturer's instructions. 2.1.2 When the MDF board coated on one side is used on the substrates mentioned in Section 1.2, it must meet the fire behaviour requirements of Class C-s1,d0 according to DIN EN 13501-1, Par. 11. 2.1.3 The MDF board coated on one side will not smoulder. During the fire shaft test according to the DIN 4102-16 standard it has met the requirements on building materials of the building material class 'flame-resistant' (DIN 4102-B1) according to DIN 4102.1, Par. 6.1.2.2.a) and 6.1.2.2c). 2.1.4 The chemical composition of the individual materials must correspond with the data deposited with the. Modifications may only be made with the consent of the. 2.2 Manufacture and Marking 2.2.1 Manufacture During the manufacture of the building product, the requirements of Par. 2.1 must be met. 2.2.2 Marking In addition to the CE marking according to the standards DIN EN 13986 and DIN EN 13964, the manufacturer has to mark the board, its packaging, the instruction leaflet of each packing unit or the delivery note with the mark of conformity in accordance with the regulations concerning conformity of the Federal States. Marking may only be made if the requirements according to Par. 2.3 have been met. The following information has to be indicated on the board, the packaging, the instruction leaflet of each packing unit or the delivery note of the building product: - Name of the product - Mark of conformity with - Name of the manufacturer - Approval number: Z-56.28-3564 Seal of 9 DIN 4102-1:1998-05 Fire behaviour of building materials and building components - Part 1: Building materials; concepts, requirements and tests

Page 5 of 6 April 18, 2012 - Logo or name of the testing institute - Manufacturing site - Fire behaviour: Class C-s1,d0 according to DIN EN 13501 1 (corresponds with the technical designation "flame-resistant"), acc. to the application requirements - The building product does not smoulder. - Other requirements according to DIN EN 13986 and DIN EN 13964 2.3 Proof of Conformity 2.3.1 General The proof of conformity of the building product with the regulations of this has to be effected for each manufacturing site based on an in-plant manufacturing control and a regular external control including an initial test of the building product according to the following regulations. For granting the certificate of conformity and the external control including the product test to be carried out in this connection, the manufacturer of the building products has to employ a certification body and a supervision body that is licensed according to cons. No. 23/3 of the "Verzeichnis der Prüf-, Überwachungs- und Zertifizierungsstellen nach den Landesbauordnungen" (Testing laboratories, inspection bodies and certification bodies recognized according to the Landesbauordnungen ('Building Regulations of the Land'), Part IIa 10. The declaration that a certificate of conformity has been issued must be given by the manufacturer by marking the building products with the mark of conformity with reference to the designated use. The certification body has to provide the with a copy of the certificate of conformity issued by the certification body. 2.3.2 In-Plant Manufacturing Control Each manufacturing site must provide and carry out an in-plant manufacturing control. An in-plant manufacturing control is the continuous control of production to be carried out by the manufacturer in order to ensure that the produced building products correspond with this. The execution of the in-plant manufacturing control is subject to the "Richtlinien zum Übereinstimmungsnachweis schwerentflammbarer Baustoffe (Baustoffklasse DIN 4102 B1) nach allgemeiner bauaufsichtlicher Zulassung" 11 (Guidelines for proof of conformance of flame-resistant building materials (Building Material Class DIN 4102 B1) as per ) in the applicable version. The results of the in-plant manufacturing control must be recorded and analyzed. The records must at least contain the following information: - Designation of the building product and/or of the raw material and the components - Type of control or test - Date of manufacture and of the test of the building product and/or of the raw material and the components - Results of controls and tests and, if applicable, comparison with the requirements - Signature of the person responsible for the in-plant manufacturing control Seal of 10 11 last published in the "Mitteilungen" of the lnstitut, Special edition No. 37 of May 20, 2009 last published in the "Mitteilungen" of the lnstitut, Edition No. 2 of April 1, 1997

Page 6 of 6 April 18, 2012 The recordings must be kept for at least five years and must be presented to the supervision body employed for external control. Upon request, they must be presented to the and the supreme building control authority concerned. In case of an insufficient test result, the manufacturer has immediately to take measures required to remedy the deficiency. Building products, which do not meet the requirements, must be handled so that they cannot be confused with products meeting the requirements. After the deficiency has been remedied and if feasible and required in proof of the rectification of deficiencies, the test must be repeated immediately. 2.3.3 External Control In each manufacturing site, the in-plant manufacturing control must be verified by an external control at regular intervals, at least once a year. The execution of the supervision is subject to the "Richtlinien zum Übereinstimmungsnachweis schwerentflammbarer Baustoffe (Baustoffklasse DIN 4102 B1) nach allgemeiner bauaufsichtlicher Zulassung" (Guidelines for proof of conformance of flame-resistant building materials (Building Material Class DIN 4102 B1) as per ) in the applicable version. In addition, the smouldering resistance test in the fire shaft must be carried out every second year. Within the framework of external control, an original inspection of the building product must be carried out, and it is also possible to take samples for sampling inspection. The authorized supervision body is responsible for sampling and inspections. The results of the certification and of the external control must be kept for at least five years. Upon request, the certification authority or the supervision body has to submit the results to the and to the supreme building control authority concerned. 3 Fire Behaviour When the instructions according to Par. 1.2 and Par. 2 are met, the MDF board coated on one side with the paint system is a flame-resistant building material (fire behaviour Class C-s1,d0 according to DIN EN 13501-1). The building product does not smoulder. 4 Implementary Regulations 4.1 The provisions of Par. 1.2 must be met. 4.2 The MDF board with a thickness of 19 mm, a gross density of at least 790 kg/m 3 and a fire behaviour of at least B-s2,d0 may be coated with a three-layer paint system consisting of - Wigranit Isolierfüller Two-Pack Insulating Filler WIG-IF with an application quantity of 250 g/m 2 - Wigranit Novacolor WNC/Colour with an application quantity of 130 g/m 2 and - Crystallit Two-Pack Solvent-Based Varnish CL with an application quantity of 120 g/m 2 on one side. When doing so, the individual constituent parts of the system in different mixing ratios are mixed with the Hardener S 8888 and PUR 5085 according to the manufacturer's instructions. Peter Proschek Head of Division Seal of Certified: Signature