Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

Similar documents
Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

NRB Disconnector for outdoor installation

Elimsan High Voltage Disconnectors

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

TECHNICAL SPECIFICATIONS

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Single-Column Pantograph Disconnectors for Outdoor Installation Type TFB three poles installation

Product Specifications for Aluminum Vertical Break Switches

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

OUTDOOR OFF LOAD DISCONNECTORS HCB/HDB Range

Product Specifications for Phase Over Phase GOABS(r)

Section 2 - Substation Switchgear

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Aluminum Vertical Break Switch kv A.

Indoor disconnectors ITr. single- and three-pole design rated voltage 12, 25 and 38.5 kv rated current A

Aluminum Vertical Break Switch 345 kv, 1300 kv BIL 2000 A A.

3TM Vacuum Contactors

Copper Vertical Break Switch kv A.

RAPIER DSB Disconnectors

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Transmission Switching

Publication No.: PSG

33KV INDOOR SWITCHGEAR

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

B kv T&D GAS INSULATED SWITCHGEAR

Operators/Accessories. Type V2-CA Aluminum. Vertical Break Switch. Ordering Information Furnish: Available Accessories. Standard Operator Features

3AP1 DTC for 145 and 245 kv

Earthing Switch Class B Hochspannungstechnik Peters & Thieding GmbH

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Rapier AX Air Break Switch Disconnector. engineering brilliant solutions

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

TYPE V CENTER BREAK SWITCH

AIR CORE REACTORS. Phoenix Electric Corporation

Gas Insulated Switchgear

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

B kv Gas-insulated Substations

3EK7 Distribution Class Surge Arresters. Answers for energy.

MEDIUM VOLTAGE SWITCHGEAR

Outdoor vacuum breaker for railway applications - FSK II

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Independent Testing Laboratory for High Voltage Equipment

3EK7 Medium Voltage Silicone Insulated Surge Arresters

3EK7 Distribution Class Surge Arresters. Answers for energy.

High-Voltage Products. Reliable products for all customer requirements. siemens.com/energy-management

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

cor Long Run Experience

Disconnectors and earthing switches up to 25 kv AC

Vacuum Circuit Breaker

Raising the bar. UHV switchgear and components

Energy Division. PCA Single Column Polymeric Surge Arrester

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

MEDIUM VOLTAGE NETWORKS

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Copper Double Break Switch

ZX2 Gas-insulated medium voltage switchgear

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

SF 6 Gas Insulated Load Break Switch

ZX-Family Gas-insulated medium voltage switchgear

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Distribution transformers Efficiency over life-cycle

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

15/60 15/60. FLa ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. Operating and maintenance instructions

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

ZX2.2 Gas-insulated medium voltage switchgear

Air-insulated switchgear UniGear type ZS1

TYPE EE and EEB CENTER- SIDE-BREAK SWITCH TYPE VEE and CBV CENTER BREAK V SWITCH 1200, 1600, 2000 & 3000 Amperes 7.

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

TECHNICAL SPECIFICATION FOR 11 KV DROP OUT (D.O.) FUSE with Polymeric Insulators:

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

3.0OVERHEAD TRANSMISSION SWITCHES

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A


M-Force three-phase switch

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Gas Insulated Metal-clad Switchgear, HMGS!

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & S HNE GMBH D MOOSBURG TEL. ( ) FAX ( )

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Transcription:

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

Table of contents Disconnectors from ABB 2 Applications 2 Standards 2 Maximum reliability and minimal maintenance 3 Technical data 4 Mode of operation 5 Easy installation 6 Main dimensions (mm) 6 Series Installation 7 Parallel installation 7 ABB is a leader in power and automation technologies that enables utility and industry customers to improve their performance while lowering environmental impact. The ABB Group of companies operates in approximately 100 countries and employs around 145,000 people. Disconnectors from ABB ABB disconnectors have been in service across the world for over two decades providing maintenance-free service with the highest records of operational reliability. The worldwide experience, often under severe climatic conditions, is applied for continual product improvement. Applications A mechanical device for providing isolation of power equipment from the network, a disconnector is suitable for switching very small currents or where no significant change in voltage occurs across the terminals. The option of earthing sections of power systems can be made available by providing each disconnector pole with one or two earthing switches. The horizontal center break disconnectors type SDF are available for rated voltages up to 550kV. Standards The SDF disconnectors are designed as per IEC 62271-102 and IEC 62271-1 standards. Other international regulations can be met on request. Type tests on the disconnectors are carried out by accredited testing laboratories in accordance with the latest regulations. Comprehensive electrical and mechanical routine tests are carried out on the poles and operating mechanism of each disconnector ensuring world class quality. 2 Horizontal Centre Break Disconnector Product brochure

Maximum reliability and minimal maintenance Minimized contact resistance The current carrying aluminum conductors are welded to minimize joint resistance. No external springs in contact fingers for maximum reliability The contact fingers of the moving contacts of disconnector type SDF are designed from special conducting material and without external springs for increased reliability. Easy and quick erection The conductors and rotary pedestals that carry current are designed for easy alignment and adjustment. Low friction design for smooth operation Maintenance-free linkages with stainless steel rod-end bearings require less drive power for operation and provide smooth motion transmission without any disturbance in the setings. Dead center interlocking for reliability under extreme conditions The dead center interlocking of operating mechanisms ensures there are no inadvertent changes in the open or close switching position even under extreme external conditions such as storms, earthquakes etc. or close switching position even under extreme external conditions such as storms, earthquakes etc. Superior design of mechanical interlock The mechanical interlock between the earth switch and main blade is designed such that there is no scope for malfunction. Ice breaking capacity The disconnectors are capable of operating under severe ice conditions. Strong rotary pedestals This ensures that the deflection remains unchanged at high static mechanical loads. Suitable for wide range of environmental conditions The disconnectors can operate in a wide range of temperatures as well as under polluted environmental conditions. Minimal maintenance Superior material and lubricant used in the encapsulation of the pedestals and rotary terminal pads makes the disconnectors practically maintenance-free. Design based on cuting-edge technology and experience The horizontal center break disconnectors type SDF consist of a steel base frame with two rotary pedestals, insulators, current carrying conductors (current path) and driving mechanisms. Steel components are hot dip galvanized to protect against atmospheric influences. Each of the three phases of the disconnector consists of two insulators mounted on maintenance free, sealed rotary pedestals which are carried by the steel base frame. The support post insulators carry the current paths consisting of two halves, with finger contacts and fist contacts. The current transfer takes place at the rotary heads of the two current paths via tulip-type contact fingers. The rotary heads can be turned 360 0 and therefore the installation of a pipe connection or the straining of connection cable is possible in any direction. Flat terminal plates can be provided as per DIN standard 46203, NEMA or any other standards. Tulip contacts of 1600 A current path terminal head Fist side current path rated for 1600 A Finger side path rated for 1600 A with earthing fixed contact mounted. Product brochure Horizontal Centre Break Disconnector 3

Technical data Voltage 72.5 kv * 123 kv 145 kv 170 kv 245 kv 300 kv 362 kv 420 kv 550 kv Type designation SDF72.5 SDF123 SDF145 SDF170 SDF245 SDF300 SDF362 SDF420 SDF550 Rated voltage (U r ) kv 72.5 123 145 170 245 300 362 420 550 Rated frequency (f r ) Hz 50/60 Rated normal current (I r ) A 1600, 2500, 3150, 4000 ** Rated short-withstand current, rated duration of short circuit (I k,t k ) ka, s 40/50/63, 1*** Rated peak withstand current (I p ) kap 2.5x I k (for 50 Hz) / 2.6x I k (for 60 Hz) Basic insulation level Power frequency withstand voltage for 1 minute To earth and between poles kv 140 230 275 325` 460 395 450 520 620 Across the isolatting distance kv 160 265 315 375 530 435 520 610 800 Lightning impulse withstand voltage To earth and between poles kvp 325 550 650 750 1050 1050 1175 1425 1550 Across the isolating distance kvp 375 650 750 860 1200 1050(+170) 1175(+205) 1425(+240) 1550 (+315) Switching impulse withstand voltage To earth and between poles kvp - - - - - 850 950 1050 1175 Across the isolating distance kvp - - - - - 700(+245) 800(+295) 900(+345) 900(+450) * 36 kv on demand ** Higher currents on demand *** 3s for 40 ka 72.5 kv SDF disconnector 4 Horizontal Centre Break Disconnector Product brochure

Mode of operation The disconnector and earthing switch are operated via independent operating mechanisms. The operating energy from the operating mechanism of the disconnectoris transmitted to one of the rotary pedestals of one phase. A diagonal rod connects both the rotary pedestals of each column ensuring simultaneous operation of both columns. The three phases of the disconnector are connected by gang operating linkages for three phase operation. During opening and closing operation both the current paths rotate through an angle of 90 0. The current paths will be at right angles to the base frame in open position. Interlocks The disconnector and earthing switch (when supplied) are mechanically interlocked. In operating mechanisms a blocking magnet can be installed as an additional interlocking facility, which in disconnected condition, makes operation of the operating mechanism impossible. Operating mechanism All disconnectors can be supplied by manual or motor operated mechanism, as required by the customer. Each three-pole disconnector or earthing switch group requires only one operating mechanism. The coupling rods between the individual poles can be continuously adapted. Operating mechanisms contain auxiliary switches for control and signaling as well as provisions for electrical interlocks. Bearing on frame assembly Earthing switch unit The earthing switch unit, an optional assembly, consists of a hingedtype earthing switch fixed at the base frame. The unit can be mounted on either of the contact sides or on both sides as required. In case of the earthing switch, the operating energy is transmitted to the earthing switch shaft. The tubular contact arm swings upwards when the unit is closing. Linkages with spherical bearings Three phase operation is conducted via mechanical or electrical gang operation. For maximum reliability the main contacts of the disconnector and earthing switch pass through the dead center positions shortly before they reach the end positions. This prevents accidental opening or closing of the units due to external influences (e.g. short-circuits, storm, earthquake). Product brochure Horizontal Centre Break Disconnector 5

Easy installation The disconnectors are delivered in following assemblies - lower part with rotary pedestals and diagonal rod, current path halves, support insulators and operarting mechanism. As all mechanical adjustments are carried out in the factory, only mounting of the assemblies, installation of the coupling rods between the poles, connection of the high-tension leads and the electrical connection leading to the operating mechanisms is required at the site. Stud bolts are provided to compensate rapidly and exactly any inaccuracies in insulator position caused due to tensile forces. Earthing switch contact side Earthing switch finger side Main dimensions as in drawing (mm) SDF72.5 SDF123 SDF145 SDF170 SDF245 SDF300 SDF362 SDF420 SDF550 A Support insulator distance 1000 1400 1650 1830 2620 2620 3200 3800 4200 B Base frame length 1300 1300 1950 2130 2920 2920 3500 4066 4466 C Disconnector height 1600 A 1325 1775 2055 2255 2855 3205 3255 2500 A 1375 1825 2105 2305 2905 3255 3255 4090 3150 A 1425 1875 2155 2355 2955 3305 3305 4140 4790 4000 A 1425 1875 2155 2355 2955 3305 3305 4140 4790 D Support insulator height 770 1220 1500 1700 2300 2650 2650 3350 4000 E Disconnector width (open) 560 760 925 1030 1370 1370 1725 2100 2380 F Isolating distance 800 1200 1450 1630 2420 2300 2700 3385 3810 G Length of earthing switch attachment 450 450 450 450 450 450 450 1050 1050 6 Horizontal Centre Break Disconnector Product brochure

Type Installation (with or without earthing switch) In series Pmin(mm) In parallel Pmin(mm) SDF72.5 1790 1270 SDF123 2700 1970 SDF145 3150 2330 SDF170 3530 2640 SDF245 4920 3520 SDF300 5350 4070 SDF360 6925 4755 SDF420 On request SDF550 On request Series installation Parallel installation Product brochure Horizontal Centre Break Disconnector 7

Contact us ABB Limited High Voltage products Maneja, Vadodara 390 013, India Phone: +91-265-2638930 Email: pt-exports.inabb@in.abb.com ABB Bulgaria EOOD High Voltage Products Sevlievo, 32, Nikola Petkov Str, Bulgaria Phone: +359 675 30043 Email: abb.sevlievo-branch@bg.abb.com www.abb.com/highvoltage Note: ABB Ltd is working continuously to improve the products. We therefore reserve the right to change designs, dimensions and data without prior notice. Public on1hyd800001e Rev.C 2012 12 Horizontal center break disconnector Type SDF up to 550 kv Copyright 2012 ABB. All rights reserved.