SECULIFE PS100 PATIENT SIMULATOR

Similar documents
1 AMP CURRENT SOURCE

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

User's Manual. Earth Ground Resistance Tester. Model Introduction

KMP Insulation-Continuity Tester. Users Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

712 RTD Calibrator. Instruction Sheet. Introduction

INSTRUCTION MANUAL DM5B Fax: (503)

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

PY-11 Voltage & Continuity Tester

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

OPERATING INSTRUCTIONS

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

362 Clamp Meter. Users Manual

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

INSP-3 Wiring Inspection Tester

American Power Design, Inc.

KSZ 10B Current Probe Calibrator. Instruction Manual

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

THWD-3 and TH-3 Relative Humidity and Temperature Meters

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

User Guide. Model Insulation Tester / Megohmmeter. Introduction

i400s Calibration Information Introduction

INSTRUCTION MANUAL M110A Fax: (503)

TIME-10 Process Control Stopwatch

Go to to register your product and find more information.

KSZ 100B Current Probe Calibrator. Instruction Manual

PLS SLD. Laser Detector PACIFIC LASER SYSTEMS. For use with your PLS pulsed laser alignment tool. The Professional Standard

Digital Thermometers Instruction Manual MODELS 868 and 869

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

Model 1672, 1673 Triple Output Power Supply

365 Detachable Jaw True-rms Clamp Meter

i3000s/i2000 Flex AC Current Probe

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

Switching DC Power Supply

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

373 Clamp Meter. Users Manual

OPERATING INSTRUCTIONS

Tension your belts at the speed of light!

SUNTURA SOLAR TRACKER

Calibration Manual. Detachable Jaw True-rms Clamp Meter

ADI-125/750 ADI-125/1500 ADI-125/2500

Model 1693, 1694 Switching DC Power Supply

Four-Position Gang Charger for SAFEMTX Li-ION Battery Packs

Digital Body Weight Scale

SUNTURA HD SOLAR TRACKER

CANARY AUDIO. Vacuum Tube Preamplifier CA-800 OWNER S MANUAL. Handcrafted in California MADE IN USA

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

DC REGULATED POWER SUPPLY

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

ATD-5540 Digital Automotive Engine Analyzer/Multimeter Owner s Manual

Infrared Thermocouple Probe

PLEASE READ BEFORE RETURNING THIS PRODUCT FOR ANY REASON.

Triple Output High Resolution Power Supply. User Manual

302+/303 Clamp Meter. Users Manual

Chair-Check II User Manual

OWNERS MANUAL JANUARY 2007 ISO

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

Users Manual. Phase Rotation Indicator

Operator s Manual TC-253A. Temperature Converter

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

1000FLT. Users Manual. Fluorescent Light Tester

ATD-5570 Deluxe Automotive Meter with RPM and Temperature Functions Owner s Manual Features:

LIBERATOR USER MANUAL

233 True-rms Remote Display Digital Multimeter Safety Information

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

G3PE-Single-phase. Solid State Relays for Heaters

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Electrical Stability Meter. Part No Instruction Manual. Updated 12/10/2015 Ver. 3.0

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi


Phase Sequence Tester

MIL-24/2600Q MIL-24/3200DQ

323/324/325 Clamp Meter

HIGH VOLTAGE PROVING UNIT

Users Manual. Airflow Meter

Autoranging Industrial Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

362 Clamp Meter. Users Manual

12.0-Volt Lithium-Ion Power Source

S150,S300 Series Pure Sine Wave Inverter User s Manual

Item no Smart AC 200 USB. User s Manual

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

will result in death or serious injury. could result in death or serious injury. Indicates a hazardous situation which, if not avoided,

707Ex. Users Manual. ma Calibrator

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Transcription:

Operating Instructions SECULIFE PS100 PATIENT SIMULATOR 3-349-714-03 1/05.13

TABLE OF CONTENTS Page WARNINGS, CAUTIONS, NOTICES... 4 DESCRIPTION SECULIFE PS100 Patient Simulator... 7 LAYOUT... 9 LIMITED WARRANTY... 13 SPECIFICATIONS... 14 NOTES... 15 GMC-I Messtechnik GmbH 3

WARNINGS, CAUTIONS, NOTICES WARNING - USE The SECULIFE PS100 is intended for testing only and should never be used in diagnostics, treatment or any other capacity where it would come in contact with a patient. WARNING - CONNECTIONS All connections to patients must be removed before connecting the DUT to the SECULIFE PS100. A serious hazard may occur if the patient is connected when testing with the SECULIFE PS100. Do not connect any leads from the patient directly to the SECULIFE PS100 or DUT. CAUTION - SERVICE The SECULIFE PS100 is intended to be serviced only by authorized service personnel. Troubleshooting and service procedures should only be performed by qualified technical personnel. CAUTION - ENVIRONMENT Exposure to environmental conditions outside the specifications can adversely affect the performance of the SECULIFE PS100. Allow the SECULIFE PS100 to acclimate to specified conditions for at least 30 minutes before attempting to operate it. CAUTION - CLEANING Do not immerse. The SECULIFE PS100 should be cleaned by wiping gently with a damp, lint-free cloth. A mild detergent can be used if desired. 4 GMC-I Messtechnik GmbH

CAUTION - INSPECTION The SECULIFE PS100 should be inspected before each use for obvious signs of abuse or wear. The SECULIFE PS100 should not be used and should be serviced if any parts are in question. CAUTION - OPENING / REPAIR The equipment may be opened only by authorized service personnel to ensure the safe and correct operation of the equipment and to keep the warranty valid. Even original spare parts may be installed only by authorized service personnel. In case the equipment was opened by unauthorized personnel, no warranty regarding personal safety, measurement accuracy, conformity with applicable safety measures or any consequential damage is granted by the manufacturer. NOTICE SYMBOLS Symbol! Description Caution (Consult Manual for Further Information) Center Negative Per European Council Directive 2002/95/EC, do not dispose of this product as unsorted municipal waste. GMC-I Messtechnik GmbH 5

NOTICE ABBREVIATIONS AHA American Heart Association ANSI American National Standards Institute BPM Beats Per Minute C Celsius degree(s) ECG Electrocardiogram F Fahrenheit Hz hertz IEC International Electrotechnical Commission Lbs pounds LED Light Emitting Diode mm millimeter(s) mv millivolt(s) NEDA National Electronic Distributors Association Ω ohm(s) USA United States of America V Volts NOTICE DISCLAIMER WILL NOT BE RESPONSIBLE FOR ANY INJURIES SUSTAINED DUE TO UNAUTHORIZED EQUIPMENT MODIFICATIONS OR APPLICATION OF EQUIPMENT OUTSIDE OF THE PUBLISHED INTENDED USE AND SPECIFICATIONS NOTICE DISCLAIMER GMC-I MESSTECHNIK GMBH RESERVES THE RIGHT TO MAKE CHANGES TO ITS PRODUCTS OR SPECIFICATIONS AT ANY TIME, WITHOUT NOTICE, IN ORDER TO IMPROVE THE DESIGN OR PERFORMANCE AND TO SUPPLY THE BEST POSSIBLE PRODUCT. THE INFORMATION IN THIS MANUAL HAS BEEN CAREFULLY CHECKED AND IS BELIEVED TO BE ACCURATE. HOWEVER, NO RESPONSIBILITY IS ASSUMED FOR INACCURACIES. NOTICE CONTACT INFORMATION GMC-I MESSTECHNIK GMBH Südwestpark 15 90449 Nürnberg Germany Phone:+49 911 8602-111 Fax:+49 911 8602-777 www.gossenmetrawatt.com e-mail: info@gossenmetrawatt.com 6 GMC-I Messtechnik GmbH

DESCRIPTION SECULIFE PS100 Patient Simulator The Model SECULIFE PS100 is a Microprocessor based Patient Simulator. It provides ECG Simulation with four waveforms with constant QRS duration and six machine performance testing waveforms. The following are highlights of some of the main features: 10 UNIVERSAL PATIENT LEAD CONNECTORS ECG: 30, 60, 120 AND 240 BPM SINE: 10, 60 AND 100 Hz SQUARE: 0.125 AND 2.000 Hz TRIANGLE: 2.000 Hz HIGH LEVEL OUTPUT (1 V p-p) AMPLITUDE ACCURACY: ± 2 % FREQUENCY ACCURACY: ± 0.5 % OF SETTING 9 VOLT BATTERY POWER LOW BATTERY INDICATOR % BATTERY LIFE INDICATOR OPTIONAL BATTERY ELIMINATOR LEAD TEST FUNCTION HIGH IMPACT PLASTIC CASE LIGHT TOUCH KEYS OPTIONAL ACCESSORIES: SOFT-SIDED CARRYING CASE BATTERY ELIMINATOR (USA Version) BATTERY ELIMINATOR (Euro Version) GMC-I Messtechnik GmbH 7

8 GMC-I Messtechnik GmbH

LAYOUT This section looks at the layout of a SECULIFE PS100 and gives descriptions of the elements that are present. 10 Waveforms with LED Indicators for Selection: ECG Selection: 30, 60, 120, 240 BPM Performance Wave Selection: Sine: 10, 60, 100 Hz Square: 0.125, 2.000 Hz Triangle: 2.000 Hz Battery Eliminator Receptacle (not shown) High Level Output (+) Lead Test Terminals Universal Patient Lead Connectors: V2/C2 V3/C3 V4/C4 V5/C5 V6/C6 RA/R LA/L RL/N (-) LL/F V1/C1 4 Light Touch Keys for Power and Waveform Selection: On Off Up Down Lead Test Indicator LED Low Battery Indicator LED 9V Battery Compartment (Back) The unit is controlled by 4 light touch keys. They allow the user to select waveforms and control the power for the unit. There is an audio click when a key is depressed. There are 10 LEDs to provide the user with information about waveforms that are generated; 1 LED for Lead Test confirmation and 1 LED for Low Battery Indication. GMC-I Messtechnik GmbH 9

Universal Patient Lead Connectors The 10 Universal Patient Lead Connectors allow for 12 lead ECG simulation with independent outputs. AHA and IEC color-coded labels are located on the face of the unit to aid in connecting the corresponding AHA and IEC Patient Leads. AHA Label IEC Label Description RA R Right Arm LA L Left Arm RL N Right Leg (reference or ground) LL F Left Leg V1 V2 V3 V4 V5 V6 C1 C2 C3 C4 C5 C6 V Leads (V1-V6) (U.S. and Canada) also referred to as pericardial, precordial or unipolar chest leads Chest Leads (C1-C6) (International) High Level Output (+) An additional Universal Patient Lead Connector is located on the top of the unit for connecting the high level ECG output signal (1 Volt p-p ). The connection is between the High Level (+) and RL/N (-) Patient Lead Connectors. Waveform Selection There are two keys and 10 LEDs in the Waveform Selection Control Section. The LEDs indicate which waveform is generated. The keys sequentially select each waveform. The microprocessor sends the stored waveform information of the selected waveform to a Digital to Analog converter that generates an accurate analog representation. This waveform is then sent through a resistor network, developing the appropriate signals on the output terminals. 10 GMC-I Messtechnik GmbH

Lead Test Terminals There are two test terminals on the top of the unit that allow for a quick test of the continuity of the lead cables. Connecting one end of the cable to one terminal and the other end to the other terminal will test the cable. If the cable is OK (less than 1000 ohms), the LEAD TEST LED in the lower left of the face will light. Power Keys The keys control the power for the unit. Auto Power Off The unit will automatically turn off after 10 minutes of no key activity to conserve the battery. To override this feature and keep the unit on continuously, depress the key twice after the unit is on. This will keep the unit on until it is manually turned off. The Low Batt LED will illuminate for 3 sec to indicate that the Auto Power Off feature has been turned off. Percent of Battery Life Indicator The unit provides an indication of the Percent of battery life left on the 9 Volt Alkaline Battery. An analog to digital converter monitors the battery voltage. Continuously holding down the key will change the 10 waveform LEDs into a Percent of Battery Life display, with each LED representing 10 % intervals. The indicator will strobe up to the present level and flash. This sequence will continue while the key is depressed. GMC-I Messtechnik GmbH 11

Battery The unit utilizes a 9 Volt Alkaline Battery in the rear battery compartment. When the unit detects a LOW BATTERY, the LED in the lower right of the face will light, indicating the need to change the battery. Battery Eliminator Input A 2.1 mm receptacle is provided for the optional 9 VDC Battery Eliminator power supply that may be used for continuous run applications. It bypasses the internal battery when plugged in. NOTE: The unit is shipped with a Red Battery Lock-Out plug installed into the line power connector as shown below. Its purpose is to prevent the unit from accidentally being turned on during handling and transport, subsequently depleting the battery. This plug must be removed before any use. 12 GMC-I Messtechnik GmbH

LIMITED WARRANTY WARRANTY: GMC-I MESSTECHNIK GMBH WARRANTS ITS NEW PRODUCTS TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP UNDER THE SERVICE FOR WHICH THEY ARE INTENDED. THIS WARRANTY IS EFFECTIVE FOR TWELVE MONTHS FROM THE DATE OF SHIPMENT. EXCLUSIONS: THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. GMC-I MESSTECHNIK GMBH IS NOT LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. NO PERSON OTHER THAN AN OFFICER IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR ASSUME ANY LIABILITY. REMEDIES: THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY SHALL BE: (1) THE REPAIR OR REPLACEMENT OF DEFECTIVE PARTS OR PRODUCTS, WITHOUT CHARGE. (2) AT THE OPTION OF GMC-I MESSTECHNIK GMBH, THE REFUND OF THE PURCHASE PRICE. GMC-I Messtechnik GmbH 13

SPECIFICATIONS PATIENT SIMULATION NORMAL SINUS RHYTHM 30, 60, 120, 240 BPM RATE PERFORMANCE WAVEFORMS SINE SQUARE TRIANGLE 10, 60, 100 Hz 0.125, 2.0 Hz 2.0 Hz ACCURACY ± 0.5 % AMPLITUDE IMPEDANCE LEAD 1 LEAD 2 LEAD 3 ACCURACY LEAD TO LEAD LEAD TEST 1.75 mv 2.75 mv 1.00 mv ± 2 % Lead II 1000 Ω < 1000 Ω CONSTRUCTION PHYSICAL & ENVIRONMENTAL ENCLOSURE FACEPLATE ABS Plastic Lexan, Back printed SIZE WEIGHT OPERATING RANGE STORAGE RANGE 7.26 x 4.46 x 1.51 Inches (184.4 x 113.3 x 38.4 mm) 1 Lbs (0.45 kg) 15 to 40 C (59 to 104 F) -20 to 65 C (-4 to 149 F) ELECTRICAL BATTERY BATTERY ELIMINATOR (Optional) 9 V Alkaline Battery (ANSI/NEDA 1604A or equivalent) 9 VDC, 50 ma 14 GMC-I Messtechnik GmbH

NOTES GMC-I Messtechnik GmbH 15

Repair and Replacement Parts Service Calibration Center* and Rental Instrument Service If required please contact: GMC-I Service GmbH Service-Center Thomas-Mann-Strasse 16-20 90471 Nürnberg Germany Phone:+49 911 817718-0 Fax: +49 911 817718-253 E-mail service@gossenmetrawatt.com www.gmci-service.com This address is only valid in Germany. Please contact our representatives or subsidiaries for service in other countries. * DAkkS Calibration Laboratory for Electrical Quantities D-K-15080-01-01 accredited per DIN EN ISO/IEC 17025:2005 Accredited quantities: direct voltage, direct current value, direct current resistance, alternating voltage, alternating current value, AC active power, AC apparent power, DC power, capacitance, frequency and temperature Product Support If required please contact: GMC-I Messtechnik GmbH Product Support Hotline Phone:+49-911-8602-0 Fax: +49 911 8602-709 E-mail:support@gossenmetrawatt.com Edited in Germany Subject to change without notice A PDF version is available on the Internet GMC-I Messtechnik GmbH Südwestpark 15 90449 Nürnberg Germany Phone +49 911 8602-111 Fax +49 911 8602-777 E-mail info@gossenmetrawatt.com www.gossenmetrawatt.com