Installation Instructions

Similar documents
Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

Installation Instructions

Owner s Information Manual

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Installation Instructions

Supplemental Installation Instructions -- August 2016

Supplemental Installation Instructions -- August 2016

Technical Manual. DLM Module. This manual should remain with the unit.

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Installation Instructions

Owner's/Installation Manual

Electrical Data Supplement

Electrical Data Supplement

Electrical Data Supplement

Electrical Data Supplement

Installation Instructions

ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTION. 20, 30 & 40 kw for 15 Ton Split System Air Conditioners Models: LB180 & LL A-0102

Installation and Start-Up Instructions

AHKD SERIES ELECTRIC RESISTANCE HEAT KITS INSTALLATION & OPERATING INSTRUCTIONS

Installation Instructions

Installation Instructions

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

Wiring Diagrams DIAGRAM INDEX

Installation Instructions

Installation Instructions For Motor Control Center (MCC) Units

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

TECHNICAL SUPPORT MANUAL Split System Air Conditioner H4A3, 3 Phase

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Installation Instructions

LED Downlight Ceiling Fixtures

Installation Manual. E-design A Transfer Switches A

TECHNICAL SUPPORT MANUAL Split System Heat Pump H2H3, 3 Phase

SERVICE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

IMPORTANT ATTENTION INSTALLERS:

Wiring Diagrams (Including Accessories) (50/60 Hz)

AUXILIARY ELECTRIC HEATER KITS FOR 7.5, 10, 15 AND 20 TON COMMERCIAL AIR HANDLERS RXHE-CE, DE

8300 Series Installation Guidelines

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A0, 3-Phase

E.S.P. Embedded Sensing Probes for Motor Brushes

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Installation Instructions

O & M Manual for the EATON Generator Ready Loadcenter

Model G14SD Vapor Management System

TECHNICAL SUPPORT MANUAL Split System Heat Pump R2HM, R2H3, WCH3**2

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Installation Instructions

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Owner s Manual. For Automatic Transfer Switch. 100 Amp. Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Installation and Start Up Instructions

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

TECHNICAL SUPPORT MANUAL WT A Coils for Replacement Service EXA, EPA

3ATS & 3NTS J-design 600 A 3ADTS & 3NDTS A Transfer Switches. Installation Manual. Installation A DANGER. Table of Contents WARNING

TECHNICAL SUPPORT MANUAL Split System Air Conditioner N2A3, 3-Phase

SM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety

Florham Park, NJ USA Call (ASCO) for sales or service

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

MODEL SCA Installation and Operation Manual Important:

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

Florham Park, NJ USA Call (ASCO) for sales or service

Manual Transfer Switch

ACCESSORY KIT INSTALLATION INSTRUCTIONS

MODEL ELC-12/60-D BATTERY CHARGER

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

5300 Series Installation Guidelines

Table of Contents General Information Safety Message Classifi cation...2 Safety Notes...3 Terminology...4 Coupler Lifting Lug...

Installation Instructions

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

poollux Power plx-pw60 & plx-pw100

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

TECHNICAL SUPPORT MANUAL Fan Coils FSM4X6000AT

Transcription:

NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Installing and servicing air conditioning equipment can be hazardous due to system pressures, electrical components, and fuel gases. Only trained and qualified personnel should install, service, or repair air conditioning equipment. Untrained personnel can perform basic maintenance functions such as cleaning coils, or cleaning and replacing filters. All other operations should be performed by trained service personnel. When working on air conditioning equipment, observe precautions in the literature, on tags, and on labels attached to the unit. Recognize safety information. This is the safety-alert symbol. When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING, and CAU- TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in serious injury or death. WARNING signifies a hazard which could result in serious injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. Follow all safety codes. Wear safety glasses and work gloves. Have a fire extinguisher available. Before proceeding with heater installation, inspect thoroughly for shipping damage. Notify shipper immediately if any damage is found. Clean all dirt, dust and moisture from heater package. Check for proper clearances of live parts, between phases and to ground. Make sure that all required barriers are in place. Check conductors run in multiple to insure that they are properly wired. Refer to unit installation instructions for complete unit installation details. The minimum air quantity for safe electric heater operation is shown in Table. Before performing installation, service or maintenance operations on this system turn off all main power switches and/or disconnects. There may be more than one switch or disconnect. Turn off accessory heater power switch if applicable. Electrical shock can cause serious injury or death. TAG DISCONNECT SWITCH(S) WITH A SUITABLE WARNING LABEL. INTRODUCTION This electric heater series is engineered, designed and listed to be installed only in the models shown in Table 1. Before proceeding, verify the heater label for correct voltage and kw requirements. Small Packaged Products 1-1/ to 5 Tons Accessory Electric Heaters Installation Instructions Electric Heaters 5 0 kw Cancels: New DESCRIPTION AND USAGE These SPP Electric heaters are to be used per Table 1 in SPP Electric Cooling & Electric Heat Pump units. Table 1 Electric Heater Usage Chart UNIT SIZE 50ZP/564A/PA1Z 0 060 50ZH/664A/PH1Z 0 060 IIK 564A--1 8-01 INSTALLATION HEATER INSTALLATION 1. Open all electrical disconnects and install lock-out tag before beginning any installation or service work.. Verify that unit duct work is installed per base unit instructions. 3. Remove top cover of the unit to access heater compartment (See Fig. 1). 4. Check proper equipment model number from list. 5. Locate and remove the heater knockout plate in the indoor blower housing (See Fig. 1). 6. Remove electric heater from the packaging. Route control and heater high voltage wire through knockout as shown in Fig. 1. 7. Install heater, sliding assembly carefully into heater area in the blower housing (See Fig. 1). Ensure that mounting holes of heater align with mounting holes on the unit. Secure heater assembly with screws provided. 8. Dress wires with wire ties provided. Route heater wires along existing unit wire bundles behind and away from capacitors. 9. Fused Units: Remove fuse links of the fuse block, attach fuse block with screws () on mounting holes provided and re-install the fuse links. Attach lid to unit panel with (4) screws provided. Align with existing mounting holes (See Fig. 1). 10. Non-Fused Units: Adhere schematic in lieu of fused block inside unit panel (See Fig. ). 11. Install ground lug in mounting hole provided adjacent to -v. compartment (See Fig. ). ELECTRICAL CONNECTION 1. Open all electrical disconnects and install lock-out tag before beginning any installation or service work.. All electrical connections, wire sizes and type of conduit shall meet the National Electric Code and State and Local Codes. Main power supply, minimum wire sizes, circuits, fusing, etc. is shown on schematic wiring diagrams. NOTE: Use minimum 75 C copper wire only. 3. Refer to base unit instructions for recommended wiring procedures. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 1 PC 101 Catalog No. 535-00038 Printed in U.S.A. Form 50Z-1SI Pg 1 8-01 Replaces: New Tab 1b 5a

UNIT VIEW ATTACHED LID WITH 4 SCREWS ADHERE GASKET (8 x 1/4) (ON FUSED MODELS) TO UNIT SIDE PANEL BETWEEN AND PANEL POWER AND CONTROL THROUGH KNOCKOUT BLOWER HOUSING HEATER AREA Fig. 1 Unit Control Box C01055 4. Connect low voltage wires as shown in heater schematic diagrams (See Figs. 5-). These connections must be made in the -v. barrier section inside the unit panel (See Fig. ). 5. Connect field power wiring as shown in heater wiring diagram. All connections should be made inside the unit and comply with the National Electric Code and State and Local Codes. Heaters with factory installed fuses may be installed on a branch circuit protected by either a fuse or circuit breaker. For all other heaters, the branch circuit must be protected by a fuse or a circuit breaker supplied by others. 6. Make all high voltage wire splice connections inside the unit control box (See Figs. 5-). Use splice connectors provided. Properly insulate connectors. Separate all wires from incoming power leads. 7. Be sure that all electrical terminal connections, clamps, screws, etc. are tight before proceeding. 8. Check wiring diagram supplied with heater for specific connections and information. 9. Check operation as described in Start-Up section. Before performing installation, service or maintenance operations on this system turn off all main power switches and/or disconnects. There may be more than one switch or disconnect. Turn off accessory heater power switch if applicable. Electrical shock can cause serious injury or death. TAG DISCONNECT SWITCH(S) WITH A SUITABLE WARNING LABEL. START-UP Before proceeding, verify that all wiring is correct per factory approved schematic. Notify factory immediately of any discrepancies. 1. Refer to base unit installation instructions as required.. Check for loose terminal connections. 3. Check that all fuse and circuit breaker short circuit interrupting ratings are adequate. 4. Turn on unit and heater power. 5. Set thermostat to call for heat. 6. Check operation of heater. 7. Check that airflow across the heater is at or above the minimum recommended CFM requirement (See Table ). Adjust indoor blower heat speed as required. 8. Any modifications or repairs to this equipment without written permission from the factory will be done at the installer s own risk and expense. TROUBLESHOOTING 1. Fuses -Malfunction will interrupt power to the unit. Check for cause of failure, replace fuses.

TOP VIEW BLOWER HOUSING PRESSOR POWER / CONTROL / / WHEN REQUIRED ADHERE SCHEMATIC WHEN NON-FUSED GROUND LUG LOCATION (SEE #11) BARRIER CONTROL PANEL V CAPACITORS HEATER S HR1, HR POWER & CONTROL HARNESS USE WIRE TIES 5 PLACES (SEE#8) C01056 Fig. Schematic Location. Limit Switch -Malfunction prevents heating element(s) from being energized. Replace switch if malfunction occurs. 3. Contactor -Malfunction will not allow heater to come on or shut off. Replace faulty contactor. Do not attempt to replace coil or dress contacts. PACKAGE CONTENTS ELECTRIC HEATER PACKAGE CONTENTS 1. Heater assembly.. UPC heater label. 3. Installation Instructions. 4. Identification label. 5. Schematic on lid door for all fused units. 6. Schematic on sticker to be placed inside unit panel for non-fused units (See Fig. ). 7. Wire connectors (3). 8. Wire ties 6 (5). TABLE Minimum Airflow for Heater Operation UNIT HEAT PUMP ELECTRIC COOLING MINIMUM AIRFLOW (CFM) UNIT SIZE 0 030 036 04 048 060 600 750 900 1050 100 1500 600 750 900 1050 100 1500 9. Screws #10B (1). 10. Splice Connectors (4). 11. Strip Gasket (8 in. x -1/4 in.) Fused models only (1). 1. Hinged lid with latch Fused models only (1). 13. Ground Lug (1) See Fig.. 3

Fig. 3 Typical A/C Wiring Schematic 08/30-1 C0100 4

Fig. 4 Typical Heat Pump Wiring Schematic 08/30-1 C010 5

V 10 AWG * T HEATER FUSES, T, 7.5/10.0 08/0-1-60 1 36.1/41.7 60A 50A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses CPHEATER0A00 Fig. 5 CPHEATER0A00 Wiring Diagram C01057 TO UNIT CONTROL V 10 AWG T * HEATER FUSES, T, CPHEATER05A00 11.3/15.0 08/0-1-60 1 54./6.5 30A 60A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses Fig. 6 CPHEATER05A00 Wiring Diagram C01058 6

V 10 AWG TO UNIT POWER 3.8/5.0 08/0-1-60 1 18.1/0.8 Replace Auto Reset with Therm-O-Disc CPHEATER06A00 Fig. 7 CPHEATER06A00 Wiring Diagram C01059 TO UNIT CONTROL V 10 AWG T * EL4 HEATER FUSES, T, CPHEATER07A00 15.0/0.0 08/0-1-60 7./83.3 60A 60A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses Fig. 8 CPHEATER07A00 Wiring Diagram C01060 7

V 10 AWG T EL4 * T5 T6 HEATER FUSES, T6 T,,, T5 CPHEATER08A00 15.0/0.0 08/0-1-60 7./83.3 50A 60A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses Fig. 9 CPHEATER08A00 Wiring Diagram C01061 TO UNIT CONTROL V 10 AWG TO 3.8/5.0 08/0-3-60 10.4/1.0 Replace Auto Reset with Therm-O-Disc CPHEATER09A00 Fig. 10 CPHEATER09A00 Wiring Diagram C0106 8

V 10 AWG TO 7.5/10.0 08/0-3-60 0.8/.1 Replace Auto Reset with Therm-O-Disc CPHEATER030A00 Fig. 11 CPHEATER030A00 Wiring Diagram C01063 TO UNIT CONTROL V 10 AWG TO 11.3/15.0 08/0-3-60 31.3/36.1 Replace Auto Reset with Therm-O-Disc CPHEATER031A00 Fig. 1 CPHEATER031A00 Wiring Diagram C01064 9

V 10 AWG T EL4 * T5 T6 HTR FUSES,, T5 T,, T6 CPHEATER03A00 11.3/15.0 08/0-3-60 31.3/36.1 50A 30A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses Fig. 13 CPHEATER03A00 Wiring Diagram C01065 TO UNIT CONTROL V 10 AWG T EL4 * T5 T6 CPHEATER033A00 HTR FUSES,, T5 T,, T6 15.0/0.0 08/0-3-60 41.7/48.1 40A 30A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses Fig. 14 CPHEATER033A00 Wiring Diagram C01066 10

V 10 AWG TO 5.0 480-3-60 6.0 Replace Auto Reset with Therm-O-Disc CPHEATER034A00 Fig. 15 CPHEATER034A00 Wiring Diagram C01067 TO UNIT CONTROL V 10 AWG TO 10.0 480-3-60 1.0 Replace Auto Reset with Therm-O-Disc CPHEATER035A00 Fig. 16 CPHEATER035A00 Wiring Diagram C01068 11

V 10 AWG TO 15.0 480-3-60 18.0 Replace Auto Reset with Therm-O-Disc CPHEATER036A00 Fig. 17 CPHEATER036A00 Wiring Diagram C01069 1

V 10 AWG TO 0.0 480-3-60.0 Replace Auto Reset with Therm-O-Disc CPHEATER037A00 Fig. 18 CPHEATER037A00 Wiring Diagram C01070 13

V 10 AWG T * HEATER FUSES, T, 3.8/5.0 08/0-1-60 1 18.1/0.8 30A 50A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses CPHEATER038A00 Fig. 19 CPHEATER038A00 Wiring Diagram C01071 TO UNIT CONTROL V 10 AWG TO UNIT POWER 7.5/10.0 08/0-1-60 1 36.1/41.7 Replace Auto Reset with Therm-O-Disc CPHEATER039A00 Fig. 0 CPHEATER039A00 Wiring Diagram C0107 14

V 10 AWG T * T5 T6 CPHEATER040A00 HEATER FUSES, T6 T, T5, 11.3/15.0 08/0-1-60 54./6.5 50A 60A 30A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses Fig. 1 CPHEATER040A00 Wiring Diagram C01073 TO UNIT CONTROL V 10 AWG T EL4 * T5 T6 HTR FUSES,, T5 T,, T6 CPHEATER041A00 14.9/19.9 08/0-3-60 41.4/47.9 60A 30A Replace Auto Reset with Therm-O-Disc Replace with 50VAC type Slo-Blow fuses Fig. CPHEATER041A00 Wiring Diagram C01074 15

Copyright 001 Carrier Corporation iik564a1 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 1 PC 101 Catalog No. 535-00038 Printed in U.S.A. Form 50Z-1SI Pg 16 8-01 Replaces: New Tab 1b 5a