Electric Immersion Pumps PXA and PXK, sealless

Similar documents
Centrifugal pumps. Main catalogue.

PS/PSL Centrifugal pumps

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

PSR Centrifugal pumps

Electric Immersion Pumps PRT and PRA, sealless

PRA Centrifugal pumps

Immersion Pumps PMS and PMS-T sealless

Immersion Pumps PRG sealless

PS/PSL Centrifugal pumps

Electric Immersion Pumps PT sealless EN

PMS Centrifugal pumps

PAB Atex-certified centrifugal pumps

SF6. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS. Page - CONTENTS 100

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE DIMENSIONS AND WEIGHT 400 PUMP DRAWING 400 DIMENSION PUMP TABLE 401

LMP screw pumps for delivery pressures up to 120 bar

Company name: Created by: Phone: Note! Product picture may differ from actual product

SF6. EBARA PUMPS EUROPE S.p.A. SUBMERSIBLE PUMPS. Page - CONTENTS 100

- CONSTRUCTIONS 300 SECTIONAL VIEW (4N1 4N2 4N4) 300 SECTIONAL VIEW (4N7 4N10 4N15) 301 SECTIONAL VIEW TABLE 302 ITEM QUANTITY FOR MODEL 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial

EVM. VERTICAL MULTISTAGE ELECTRIC PUMPS in cast iron, AISI 304, AISI 316. Your Life, our Quality. Worldwide. 36 Commercial

CM1-8 A-R-I-E-AQQE F-A-A-N

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives

Single- and Multicircuit Pumps

Pressure boosting Single pumps

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 INTERMEDIATE CASING WITH BEARING POSITION 303

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CRK 2-180/18 A-W-A-AUUV 3x380 /415Y V

Data sheet: Wilo-Multivert MVI 805 (3~400 V, EPDM, PN 16)

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

CM3-5 A-R-I-E-AQQE F-A-A-N

CM5-9 A-R-I-E-AQQE F-A-A-N

GRUNDFOS DATA BOOKLET MTS. Screw pumps 50/60 Hz

Feed Pumps VP / VPB / VPBM

Contents. General data. Technical data, SPK/CRK. General data, MTA(D) Technical data, MTA(D) General data, MTR. General data, MTC

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

50 Hz. Z612, Z616, Z622 Z631, Z646, Z660 Series 6 SUBMERSIBLE ELECTRIC PUMPS. ErP 2009/125/EC

4.2 FIXED DISPLACEMENT DOUBLE PUMP

CM3-6 A-R-G-E-AQQE C-A-A-N

CM3-11 A-R-G-E-AQQE F-A-A-N

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

Side Channel Pumps Self-priming, segmental type

CM1-2 A-R-A-E-AQQE F-A-A-N

CRK 2-180/18 A-W-A-AUUV 3x230/400V 60HZ

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

S4G Series. Technical Guide. 4 submersible pumps

Axial Piston Fixed Pump A17FNO Series 10

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

EH -EHsp SERIES 50 Hz

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

CM5-5 A-R-G-V-AQQV F-A-A-N

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives Technical Data Sheet

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

Data sheet: Wilo-Multivert MVI 205 (3~400 V, EPDM, PN 16)

IPV catalog High-pressure internal gear pumps

High Pressure Centrifugal Pumps Product Overview

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-4 A-A-A-E-HQQE 3x230/400 50HZ

Change-Over Pressure Filter DFDK

Automatic metal-edge filter AF 71 G

Data sheet: Wilo-Multivert MVI 404 (1~230 V, EPDM, PN 16)

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

Automatic metal-edge filter AF 73 G/AF 93 G

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

Grease-lubricating pump FF... DSK US (05.05)

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

CRN10-02 A-P-G-E-HQQE 3x230/ HZ

High-pressure pumps Series HP45

CRE20-08 A-F-A-E-HQQE 3x HZ

Automatic metal-edge filters AF 72 G

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304

VECTOLUB Minimal Quantity Lubrication

Lowara. Centrifugal electric pumps made of AISI 316 stainless steel in compliance with EN 733. SH Series. 50 Hz

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CM10-1 A-R-A-E-AQQE F-A-A-N

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

CRN3-7 A-P-G-E-HQQE 3x230/400 50HZ

WINNER SUBMERSIBLE MULTISTAGE PUMPS EPA

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

Side Channel Pumps Self-priming, segmental type with verly low NPSH

CM1-6 A-R-I-E-AQQE F-A-A-N

CME5-5 A-R-I-E-AQQE S-A-D-N

Axial Piston Fixed Pump A2FO

UNIBAD. Bath water circulating pump

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

GRUNDFOS DATA BOOKLET MTR(E), MTH, MTA. Immersible pumps 50/60 Hz

CRN1S-9 A-P-G-V-HQQV 3x230/400 50HZ

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

DUMPER. Data Book 50 Hz

CM5-6 A-R-A-E-AQQE C-A-A-N

Transcription:

1-6062-US PXA and PXK, sealless MQUALITY MANAE ENT Cooling and lubricating with high-pressure... Centrifugal pumps for delivery pressures up to 25 bars Technical data Delivery rate Q max = 185 l/min Delivery head max = 250 m Temperature range 10 C to +90 C Product features igh-efficiency multi-section centrifugal pump Fast and simple startup Flexible drive concept igh depndability and a long service life PXK: compact, space-saving design

PXA and PXK Main applications Machine tools Coolant supply and conditioning systems Filtration systems Tempering equipment Washing and cleaning installations etc. Fluids delivered clean, turbid and air-free fluids without long-fibered or abrasive constituents aqueous emulsions low-viscosity cooling and cutting oils, synthetic and based on mineral oils The following limit values must be complied with when contaminated or highly viscous fluids are involved: Max. grain size: ø 2 mm Max. contamination: 50 g/m 3 Max. kinematic viscosity: 20 mm 2 /s Check the motor power when the density or viscosity deviates from that of water. Temperature range: 10 C to +90 C. Design features Mechanical design Components Material Pump port NI 40 (PXA) CI 25 (PXK) Pump shaft stainless steel 1.4305 Shaft adapter stainless steel 1.4122 Interm. chamber stainless steel 1.4301 Impeller stainless steel 1.4301 Shaft bearing Secondary seals Al-oxide/tungsten carbide FPM (Viton) Tie-rod stainless steel 1.4057 Pump bottom CI 25 ap bush Mechanical seal Accessories Sint-St Carbon/SIC/FPM Material Strainer stainless steel 1.4301 Bottom for extension tube stainless steel 1.4301 Extension tube steel Type and state of shaft seal Flange and port dimensions to DIN EN 12157 Shaft seal up to 15 bars with low-wear gap bush, after 16 bars with mechanical seal. Motor and pump shaft connection PXA Delivery heads up to 250 m (25 bars) Pump and motor shaft separated by coupling Use of a double-gimbal curved-tooth coupling Shaft bearing in pump section Use of standard motors PXK Delivery heads up to 70 m (7 bars) Direct but detachable connection of motor and pump shaft Compact version with small motor dimensions PXA and PXK power range Performance data for 50 z Performance data for 60 z 250 800 750 700 650 200 550 150 450 350 100 250 150 100 50 0 50 40 30 20 10 0 0 0 0 PXA02 PXK02 PXA04 PXK04 25 50 75 100 125 150 175 10 20 30 10 20 30 40 250 800 750 700 650 200 550 150 450 350 100 250 150 100 50 0 50 40 30 20 10 0 PXA02 PXK02 PXA04 PXK04 0 25 50 75 100 125 150 175 0 10 20 30 0 10 20 30 40 2

PXA and PXK Electrical design The drive motors meet VDE regulations as well as European motor standards (DIN EN 60034-1/02.99) and the requirements underlying the CE mark. Designs in conformity with non-european regulations, e.g. CSA, UL or special requirements, e.g. the USA or Japan, are possible. Degree of protection:..... IP 55 (DIN EN 60034-5/4.88) Direction of rotation:.... clockwise as viewed from above looking down on the motor's ventilation side. Insulation class:......... F Ambient temperature:.... max. 40 C (DIN EN 60034-1/02.99) at a max. of 1000 above sea level Electrical parameters..... 4 kw: 230/400 V, 50 z 265/460 V, 60 z > 4 kw: 400 V, 50 z 460 V, 60 z Installation and operation Other mains voltages on request. Suitable in the standard version for vertical installation in the reservoir. Other installation situations available on request. When the pump is switched on the minimum level of fluid has to be above the bottommost pump chamber ➀. The pump then delivers all the way to the intake in the chamber or tube ➁. The maximum permissible level of fluid amounts to 30 mm below the reservoir's cover ➂. Versions: with empty intermediate chambers with extension tube Type key Model PXA - up to 25 bars PXK - up to 7 bars Motor size 02 = 2 m 3 /h 04 = 4 m 3 /h Number of stages See the tables for details Material type = cast iron (standard) Seal type B = ap bush = Mechanical seal Pump type S = basic outfitting V = prepared for extension tube Immersion depth See the tables for details Motor index See the tables for details Electrical data 01 = 230/400 V 50 z; 265/460 V 60 z (standard up to 4 kw) 02 = 400/690 V, 50 z; 460 V, 60 z (standard after 5.5 kw) Andere Netzverhältnisse auf Anfrage Motor type AA = Standard (insulation class F, IP 55, 2-pole type) AI = Motor with frequency converter AC = UL /CSA version AD = Industrial connector (DESINA) Sectional drawing PXA PXA 02 04 B S 185 D 01 AA ➂ ➀ ➀ ➁ Fig.: different delivery characteristics at the same immersion depth. Dry running is not permitted in principle. A minimum volumetric flow of 5 to 10 % of the nominal delivery rate must be assured. Additional equipment for extension tube for intake strainer 3

PXA02 50 z Electrical data, dimensions and weights Immersion Rated Rated Rated Rated Dimensions [mm] Rated motor values for 230/400V Seal depth Motor Motor power current current Y speed Weight Model type 1 ) t [mm] index size P N [kw] I N [A] I N [A] n N [rpm] ø a b c ø d e [kg] PXA02 02 B 143 E 71M 0.37 1.73 1.00 2740 145 111 333 160 123 13.1 PXA02 03 B 164 PXA02 04 B 185 PXA02 05 B 206 PXA02 06 B 227 PXA02 07 B 248 PXA02 08 B 269 PXA02 09 B 290 PXA02 10 B 311 PXA02 11 B 332 PXA02 12 B 374 PXA02 13 B 374 PXA02 14 B 416 PXA02 15 B 416 PXA02 16 437 PXA02 17 479 PXA02 18 479 PXA02 19 521 PXA02 20 521 PXA02 21 584 PXA02 22 584 PXA02 23 584 PXA02 24 626 F 71M 0.55 2.36 1.36 2800 145 111 333 160 123 15 E 0.37 1.73 1.00 2740 13.4 F 71M 0.55 2.36 1.36 2800 145 111 333 160 123 15.3 E 0.37 1.73 1.00 2740 13.7 80M 0.75 3.00 1.73 2855 162 120 357 200 123 17.5 F 71M 0.55 2.36 1.36 2800 145 111 333 160 123 15.6 80M 0.75 3.00 1.73 2855 162 120 357 200 123 17.8 F 71M 0.55 2.36 1.36 2800 145 111 333 160 123 15.9 80M 1.1 4.16 2.40 2845 162 120 357 200 123 19.8 0.75 3.00 1.73 2855 18.1 80M 1.1 4.16 2.40 2845 162 120 357 200 123 20.1 0.75 3.00 1.73 2855 18.4 J 90S 1.5 5.63 3.25 2860 23.9 80M 1.1 4.16 2.40 2845 162 120 357 200 123 20.4 J 90S 1.5 5.63 3.25 2860 24.2 80M 1.1 4.16 2.40 2845 162 120 357 200 123 20.7 J 90S 1.5 5.63 3.25 2860 24.5 80M 1.1 4.16 2.40 2845 162 120 357 200 123 21.0 J 90S 1.5 5.63 3.25 2860 25.1 80M 1.1 4.16 2.40 2845 162 120 357 200 123 21.6 K 90L 2.2 7.88 4.55 2880 27.9 J 90S 1.5 5.63 3.25 2860 25.1 K 90L 2.2 7.88 4.55 2880 28.5 J 90S 1.5 5.63 3.25 2860 25.7 K 90L 2.2 7.88 4.55 2880 28.5 J 90S 1.5 5.63 3.25 2860 25.7 K 90L 2.2 7.88 4.55 2880 28.8 J 90S 1.5 5.63 3.25 2860 26.0 K 90L 2.2 7.88 4.55 2880 29.4 J 90S 1.5 5.63 3.25 2860 26.6 K 90L 2.2 7.88 4.55 2880 29.4 L 100L 3.0 10.57 6.1 2890 202 135 456 250 143 36.8 K 90L 2.2 7.88 4.55 2880 30 L 100L 3.0 10.57 6.1 2890 202 135 456 250 143 36.8 K 90L 2.2 7.88 4.55 2880 30 L 100L 3.0 10.57 6.1 2890 202 135 456 250 143 37.7 K 90L 2.2 7.88 4.55 2880 30.9 L 100L 3.0 10.57 6.1 2890 202 135 456 250 143 37.7 K 90L 2.2 7.88 4.55 2880 30.9 L 100L 3.0 10.57 6.1 2890 202 135 456 250 143 37.7 K 90L 2.2 7.88 4.55 2880 30.9 L 100L 3.0 10.57 6.1 2890 202 135 456 250 143 38.3 K 90L 2.2 7.88 4.55 2880 31.5 M 112M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3 PXA02 25 626 L 100L 3.0 10.57 6.1 2890 202 135 456 250 143 38.3 K 90L 2.2 7.88 4.55 2880 31.5 1) B = ap bush Power required to cover the entire characteristic curve = Mechanical seal 4

PXA02 50 z Characteristics and power curves PXA02 50 z 2850 rpm max. level of fluid min. level of fluid Data for a viscosity of 1 mm 2 /s at a density of 1 kg/dm 3 Minimum volumetric flow: 5 to 10 % of nominal delivery rate. η [%] P St [kw] Power curve P2 in kw per active stage (with impeller) and pump efficiency η in %. The pump's power requirements are determined by the operating point on the characteristic curve and by the number of impellers. When determining the required motor power please observe the recommended safety allowances set out in DIN ISO 9908 5

PXA02 60 z Electrical data, dimensions and weights Immersion Rated Rated Rated Rated Dimensions [mm] Rated motor values for 265/460V Seal depth Motor Motor power current current Y speed Weight Model type 1 ) t [mm] index size P N [kw] I N [A] I N [A] n N [rpm] ø a b c ø d e [kg] PXA02 02 B 143 E 71M 0.43 1.73 1.00 3340 145 111 333 160 123 13.4 PXA02 03 B 164 PXA02 04 B 185 PXA02 05 B 206 PXA02 06 B 227 PXA02 07 B 248 PXA02 08 B 269 F 0.63 2.36 1.36 3400 15 71M 145 111 333 160 123 E 0.43 1.73 1.00 3340 13.4 80M 0.86 3.00 1.73 3455 162 120 357 200 123 15.6 F 71M 0.63 2.36 1.36 3400 145 111 333 160 123 15 1.3 4.16 2.40 3445 18.1 80M 162 120 357 200 123 0.86 3.00 1.73 3455 15.6 1.3 4.16 2.40 3445 18.1 80M 162 120 357 200 123 0.86 3.00 1.73 3455 15.6 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 K 90L 2.55 7.88 4.55 3480 23.9 PXA02 09 B 290 J 90S 1.75 5.63 3.25 3460 19.8 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 PXA02 10 B 311 PXA02 11 B 332 K 90L 2.55 7.88 4.55 3480 23.9 J 90S 1.75 5.63 3.25 3460 19.8 K 90L 2.55 7.88 4.55 3480 23.9 J 90S 1.75 5.63 3.25 3460 19.8 PXA02 12 B 374 K 90L 2.55 7.88 4.55 3480 23.9 J 90S 1.75 5.63 3.25 3460 19.8 PXA02 13 B 374 PXA02 14 B 416 PXA02 15 B 416 PXA02 16 437 M 112M 4.6 13.51 7.8 3505 227 148 477 250 143 45.3 PXA02 17 479 1) B = ap bush Power required to cover the entire characteristic curve = Mechanical seal 6

PXA02 60 z Characteristics and power curves PXA02 60 z 3420 rpm max. level of fluid min. level of fluid Data for a viscosity of 1 mm 2 /s at a density of 1 kg/dm 3 Minimum volumetric flow: 5 to 10 % of nominal delivery rate. η [%] P St [kw] Power curve P2 in kw per active stage (with impeller) and pump efficiency η in %. The pump's power requirements are determined by the operating point on the characteristic curve and by the number of impellers. When determining the required motor power please observe the recommended safety allowances set out in DIN ISO 9908 7

PXA04 50 z Electrical data, dimensions and weights 1) B = ap bush *) > 4 kw : 400 V Power required to cover the entire characteristic curve = Mechanical seal 8 Immersion Rated Rated Rated Rated Dimensions [mm] Rated motor values for 230/400V up to 4 kw *) Seal depth Motor Motor power current current Y speed Weight Model type 1 ) t [mm] index size P N [kw] I N [A] I N [A] n N [rpm] ø a b c ø d e [kg] PXA04 02 B 143 PXA04 03 B 164 PXA04 04 B 185 PXA04 05 B 206 PXA04 06 B 227 PXA04 07 B 248 PXA04 08 B 269 PXA04 09 B 290 PXA04 10 B 311 PXA04 11 B 332 PXA04 12 B 374 PXA04 13 B 374 PXA04 14 B 416 PXA04 15 B 416 F 71M 0.55 2.36 1.36 2800 145 111 333 160 123 15 E 0.37 1.73 1.00 2740 13.4 80M 0.75 3.00 1.73 2855 162 120 357 200 123 15.6 F 71M 0.55 2.36 1.36 2800 145 111 333 160 123 15 80M 0.75 3.00 1.73 2855 162 120 357 200 123 15.6 F 71M 0.55 2.36 1.36 2800 145 111 333 160 123 15 80M 1.1 4.16 2.40 2845 162 120 357 200 123 18.1 0.75 3.00 1.73 2855 15.6 J 90S 1.5 5.63 3.25 2860 19.8 80M 1.1 4.16 2.40 2845 162 120 357 200 123 18.1 J 90S 1.5 5.63 3.25 2860 19.8 80M 1.1 4.16 2.40 2845 162 120 357 200 123 18.1 J 90S 1.5 5.63 3.25 2860 19.8 80M 1.1 4.16 2.40 2845 162 120 357 200 123 18.1 K 90L 2.2 7.88 4.55 2880 23.9 J 90S 1.5 5.63 3.25 2860 19.8 K 90L 2.2 7.88 4.55 2880 23.9 J 90S 1.5 5.63 3.25 2860 19.8 K 90L 2.2 7.88 4.55 2880 23.9 J 90S 1.5 5.63 3.25 2860 19.8 K 90L 2.2 7.88 4.55 2880 23.9 K 90L 2.2 7.88 4.55 2880 23.9 K 90L 2.2 7.88 4.55 2880 23.9 K 90L 2.2 7.88 4.55 2880 23.9 PXA04 16 437 K 90L 2.2 7.88 4.55 2880 23.9 M 112M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3 PXA04 17 479 K 90L 2.2 7.88 4.55 2880 23.9 PXA04 18 479 PXA04 19 521 PXA04 20 521 M 112M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3 M 112M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3 M 112M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3 PXA04 21 584 M 112M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3 N 112M 5.5 10.3 2925 227 148 514 250 143 45.3 PXA04 22 584 M 112M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3 N 112M 5.5 10.3 2925 227 148 514 250 143 45.3 PXA04 23 584 M 112M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3 PXA04 24 626 PXA04 25 626 N 112M 5.5 10.3 2925 M 4.0 13.51 7.8 2905 227 148 514 250 143 45.3 N 112M 5.5 10.3 2925 227 148 514 250 143 45.3 M 4.0 13.51 7.8 2905 227 148 477 250 143 45.3

Electrical Immersion Pumps PXA04 50 z Characteristics and power curves PXA04 50 z 2850 rpm max. level of fluis min. level of fluid Data for a viscosity of 1 mm 2 /s at a density of 1 kg/dm 3 Minimum volumetric flow: 5 to 10 % of nominal delivery rate. η P St [%] [kw] Power curve P2 in kw per active stage (with impeller) and pump efficiency η in %. The pump's power requirements are determined by the operating point on the characteristic curve and by the number of impellers. When determining the required motor power please observe the recommended safety allowances set out in DIN ISO 9908 9

PXA04 60 z Electrical data, dimensions and weights Immersion Rated Rated Rated Rated Dimensions [mm] Rated motor values for 265/460V up to 4,6 kw *) Seal depth Motor Motor power current current Y speed Weight Model type 1 ) t [mm] index size P N [kw] I N [A] I N [A] n N [rpm] ø a b c ø d e [kg] PXA04 02 B 143 F 71M 0.63 2.36 1.36 3400 145 111 333 160 123 15 E 0.43 1.73 1.00 3340 13.4 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 PXA04 03 B 164 80M 0.86 3.00 1.73 3455 162 120 357 200 123 15.6 F 71M 0.63 2.36 1.36 3400 145 111 333 160 123 15 E 71M 0.43 1.73 1.00 3340 145 111 333 160 123 13.4 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 PXA04 04 B 185 80M 0.86 3.00 1.73 3455 162 120 357 200 123 15.6 F 71M 0.63 2.36 1.36 3400 145 111 333 160 123 15 E 71M 0.43 1.73 1.00 3340 145 111 333 160 123 13.4 PXA04 05 B 206 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 80M 0.86 3.00 1.73 3455 162 120 357 200 123 15.6 F 71M 0.63 2.36 1.36 3400 145 111 333 160 123 15 PXA04 06 B 227 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 80M 0.86 3.00 1.73 3455 162 120 357 200 123 15.6 PXA04 07 B 248 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 80M 0.86 3.00 1.73 3455 162 120 357 200 123 15.6 PXA04 08 B 269 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 80M 0.86 3.00 1.73 3455 162 120 357 200 123 15.6 PXA04 09 B 290 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 PXA04 10 B 311 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 PXA04 11 B 332 80M 1.3 4.16 2.40 3445 162 120 357 200 123 18.1 M 112M 4.6 13.51 7.8 3505 227 148 477 250 143 45.3 PXA04 12 B 374 M 112M 4.6 13.51 7.8 3505 227 148 477 250 143 45.3 PXA04 13 B 374 M 112M 4.6 13.51 7.8 3505 227 148 477 250 143 45.3 PXA04 14 B 416 M 112M 4.6 13.51 7.8 3505 227 148 477 250 143 45.3 PXA04 15 B 416 N 112M 6.3 10.3 3525 227 148 514 250 143 45.3 M 112M 4.6 13.51 7.8 3505 227 148 477 250 143 45.3 PXA04 16 437 N 112M 6.3 10.3 3525 227 148 514 250 143 45.3 PXA04 17 479 M 112M 4.6 13.51 7.8 3505 227 148 477 250 143 45.3 1) B = ap bush; = Mechanical seal *) > 4 kw : 400 V Power required to cover the entire characteristic curve 10

Electrical Immersion Pumps PXA04 60 z Characteristics and power curves PXA04 60 z 3420 rpm max. level of fluid min. level of fluid Data for a viscosity of 1 mm 2 /s at a density of 1 kg/dm 3 Minimum volumetric flow: 5 to 10 % of nominal delivery rate. η [%] P St [kw] Power curve P2 in kw per active stage (with impeller) and pump efficiency η in %. The pump's power requirements are determined by the operating point on the characteristic curve and by the number of impellers. When determining the required motor power please observe the recommended safety allowances set out in DIN ISO 9908 11

Electrical Immersion Pumps PXA Pump section Motor Coupling boss Coupling sleeve Fastener 1 Port 2 Coupling boss 3 Shaft adapter 4 Radial deep-groove ball bearing 5 Shaft seal 6 Venting screw 7 Washer 8 ap bush or mechanical seal 9 O-ring or packing ring 10 Tie-rod 11 Washer 12 exagon nut 13 Shaft 14 Snap ring 15 Stop collar 16 Impeller 17 Intermediate chamber bearing 18 Carbide bush-bearing 19 Spacer bushing bearing 20 Intermediate chamber with guide vane 21 Chamber spacer bushing 22 Empty chamber 23 Empty chamber spacer bushing 24 Intermediate chamber without guide vane 25 End bush 26 exagon nut 27 Bottom Z Intake strainer 12

Electrical Immersion Pumps PXK roup PXK multistage, vertical centrifugal pump sealless multi-section design with closed impellers flange and port dimensions to DIN EN 12157 hydraulic components from the modular multi-section PX. pump system space-saving expansion of roup PXA developed for the low and medium pressure range (up to approx. 7 bars) unit consisting of pump and motor with a rigid shaft compact design with high efficiency potential greatly improved dependability and service ease Sectional drawing of PXK Additional equipment for extension tube for intake strainer Immersion depth Weight Model t [mm] [kg] PXK02 02 143 12.2 PXK02 03 164 12.5 PXK02 04 185 12.8 PXK02 05 206 13.1 PXK02 06 227 13.4 PXK02 07 248 13.7 PXK04 02 143 12.3 PXK04 03 164 12.7 PXK04 04 185 13.1 max. level of fluid PXK04 05 206 13.5 PXK04 06 227 13.9 min. level of fluid PXK04 07 248 14.3 Seal type = ap bush 13

Electrical Immersion Pumps PXK02 Characteristics, power curves and electrical data Charactteristics for 50 z Characteristics for 60 z PXK02 50 z 2850 rpm PXK02 60 z 3420 rpm Data for a viscosity of 1 mm 2 /s at a density of 1 kg/dm 3 η [%] P St [kw] η P St [%] [kw] Power curve P2 in kw per active stage (with impeller) and pump efficiency η in %. The pump's power requirements are determined by the operating point on the characteristic curve and by the number of impellers. When determining the required motor power please observe the recommended safety allowances set out in DIN ISO 9908 14 Electrical data Motor Motor Rated power Rated voltage Rated frequency Rated current Rated current Y Rated speed Model index size P N [kw] U N [V] f N [z] I N [A] I N [A] n N [min -1 ] 0.55 2.06 1.19 2836 F 71M PXK02 02 0.37 0.91 0.37 2902 PXK02 03 0.63 2.06 1.19 3430 F 71M 265 / 460 60 0.43 1.73 1.00 2740 PXK02 04 PXK02 05 PXK02 06 PXK02 07 0.75 3.46 2.00 2846 0.55 2.87 1.66 2860 0.86 3.30 1.91 3403 265 / 460 60 0.63 2.87 1.66 3450 1.00 4.07 2.35 2769 0.75 3.46 2.00 2846 1.10 3.55 2.05 3325 265 / 460 60 0.86 3.30 1.91 3403 1.00 4.07 2.35 2769 0.75 3.46 2.00 2846 1.26 4.15 2.40 3320 265 / 460 60 1.00 3.55 2.05 3325 1.00 4.07 2.35 2769 0.75 3.46 2.00 2846 Power required to cover the entire characteristic curve

Electrical Immersion Pumps PXK04 Characteristics, power curves and electrical data Characteristics for 50 z Characteristics for 60 z PXK04 50 z 2850 rpm PXK04 60 z 3420 rpm Data for a viscosity of 1 mm 2 /s at a density of 1 kg/dm 3 η P St [%] [kw] η P St [%] [kw] Power curve P2 in kw per active stage (with impeller) and pump efficiency η in %. The pump's power requirements are determined by the operating point on the characteristic curve and by the number of impellers. When determining the required motor power please observe the recommended safety allowances set out in DIN ISO 9908 Electrical Data Motor Motor Rated power Rated voltage Rated frequency Rated current Rated current Y Rated speed Model index size P N [kw] U N [V] f N [z] I N [A] I N [A] n N [min -1 ] PXK04 02 PXK04 03 PXK04 04 PXK04 05 F F 71M 71M 0.55 2.06 1.19 2836 0.37 1.57 0.91 2902 0.63 2.06 1.19 3430 265 / 460 60 0.43 1.57 0.91 3490 0.75 3.46 2.00 2846 0.55 2.87 1.66 2860 0.86 3.30 1.91 3403 265 / 460 60 0.63 2.87 1.66 3450 0.75 3.46 2.00 2846 0.55 2.87 1.66 2860 1.26 4.15 2.40 3320 265 / 460 60 1.10 3.55 2.05 3325 1.00 4.07 2.35 2769 0.75 3.46 2.00 2846 1.26 4.15 2.40 3320 265 / 460 60 1.10 3.55 2.05 3325 1.00 4.07 2.35 2769 PXK04 06 0.75 3.46 2.00 2846 PXK04 07 71 L 1.00 4.07 2.35 2769 Power required to cover the entire characteristic curve 15

Electrical Immersion Pumps PXK Fastener Dowel pin O-ring Motor 1 Port 4 Radial deep-groove ball bearing 5 Shaft seal 8 ap bush or mechanical seal 9 O-ring or packing ring 10 Tie-rod 11 Washer 12 exagon nut 13 Shaft 14 Snap ring 15 Stop collar 16 Impeller 17 Intermediate chamber bearing 18 Carbide bush-bearing 19 Spacer bushing bearing 20 Intermediate chamber with guide vane 21 Chamber spacer bushing 22 Empty chamber 23 Empty chamber spacer bushing 24 Intermediate chamber without guide vane 25 End bush 26 exagon nut 27 Bottom Z Intake strainer Motzener Strasse 35 / 37, 12277 Berlin, ermany P.O. Box 97 04 44, 12704 Berlin, ermany Phone (++49) 30-720 02-0 Fax (++49) 30-720 02-111 E-mail: info@vogel-berlin.de Internet: www.vogelag.com Subject to change without notice. 16 W000 05 2003