Hydrogen Station Equipment Performance Device (HyStEP Device) Specification

Similar documents
Industry-Wide Light Duty Hydrogen Vehicle Fueling Protocol up to 70MPa: Created by Math Modeling and Confirmed by System Testing

An Advanced Fueling Algorithm The MC Method. Ryan Harty and Steve Mathison Honda R&D Americas, Inc

AVL SERIES BATTERY BENCHMARKING. Getting from low level parameter to target orientation

This document is a preview generated by EVS

TRANSPORT OF DANGEROUS GOODS

Pressure Control SYSTEMS

Proposal for amendments to UN Regulation No. 110 CNG/LNG vehicles

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

ABB MEASUREMENT & ANALYTICS. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

Team Aware Perception System using Stereo Vision and Radar

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

TEMPERATURE CHANGE OF A TYPE IV CYLINDER DURING HYDROGEN FUELING PROCESS

Oshkosh Corporation MTVR On Board Vehicle Power Program Update. May 5, Built Strong. Building for the Future.

POWERTRAIN SOLUTIONS FOR ELECTRIFIED TRUCKS AND BUSES

Autonomous Power Supply Uninterruptible Power Supply (UPS)

Features. V max (Vdc) I max (A) typ. (W) P d

SERIES Pulse and 12 Pulse DC Power Supplies for Electrocoating and Industrial DC Powered Systems MODELS 506 & 5012

Measurement made easy. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

GENERAL SPECIFICATION

Accelerated Testing of Advanced Battery Technologies in PHEV Applications

Surface Mount > 0603L Series. Description. Features. Applications. Maximum Time To Trip Current (A) P d typ. (W)

Evaporative Emissions

Critical Power Switchboards. Selection and Application Guide

EC type-examination certificate UK/0126/0072 Revision 2

LIQUID MEASUREMENT STATION DESIGN Class No

Compressed Natural Gas Vehicle Fuel System Inspection Guidance

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

D. Operation and Maintenance Data. In addition to items specified in Division 1 Section "Operation and Maintenance Data," include the following:

Advanced Techniques US Inc.

Features. Samples. I max (A) P d. typ. (W)

VIA Platform Environmental Qualification Testing Standards

Hydrogen & Fuel Cell Standards Update. Julie Weis, Sara Marxen, and Julie Cairns August 2014

BUSWAY Low Voltage (Pow-R-Flex)

POLY-FUSE Resettable PTCs. 2920L Series. Surface Mount > 2920L Series E R RoHS. Description

2012 Dalhousie University Formula SAE Design Report

SECTION GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT

(2111) Digital Test Rolling REVISED 07/22/14 DO NOT REMOVE THIS. IT NEEDS TO STAY IN FOR THE CONTRACTORS. SP

Lithium Ion Medium Power Battery Design

University of Houston Master Construction Specifications Insert Project Name

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

Life Extension Testing of Electrical Penetration Assemblies

Exhibit 5. Vapor to Liquid Volume Ratio (Executive Orders VR-201-F and VR-202-F) (Healy Model 900 EVR Nozzle)

National Robotic Arc Welding Conference Joy Global Welding Automation June, 2013

Earthsafe Systems, Inc. Emergency Power Fuel Systems Recommended System Standard

Number Title Year Organization Page

Titelgrau belassen! Leere Vorlage

Natural Gas for Transportation Codes & Standards Issues

NO ENTRY No entry for Models 605, 610 or 620. Enter maximum flow rate for Model 600 with external flow sensor

FreezeFree TM Nitro Anti-Icing System GENERAL SPECIFICATIONS

ECTOS Deliverable 4. European Commission. Fifth Framework For Research And Development

Surface Mount > 1210L Series. Description. Features. Applications. Maximum Time To Trip Current (A) P d typ. (W) Time (Sec.)

Jet Dispensing Underfills for Stacked Die Applications

Ampd Silo. Energy Storage System. Maintenance-free Li-ion energy storage for mission critical backup. Power to Empower

Surface Mount > 1812L Series. Description. Features. Applications. I max (A) typ. (W) P d. Current (A)

Refuelling High-Performance Components for Hydrogen Vehicles and Fuelling Stations

A Guide to Dry Block Calibration

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Automated and precise static load testing with absolute control and high performance

SMC Standard SMC-S June Supersedes: New issue. Air Force Space Command SPACE AND MISSILE SYSTEMS CENTER STANDARD

Product Data Sheet. Part Number: Gen 2 Back of Cab. Product Technical Specifications

Positive Temperature Coefficient (PTC) Data Sheet

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Kanpur , Uttar Pradesh, India Centre for Lasers and Photonics

Quick Installation Guide for X50 Plus Car OBD Multi-function instrument Product introductions

Temperature Control Systems

AVL FUEL BALANCE & FUEL TEMPERATURE CONTROL

MCS. Important Information on MCS 012 Issue 2.1 for MCS Solar Photovoltaic and Solar Thermal Contractors. Last Updated: 25 th September 2017

Overview. Selection of System Components VT BBK/CWH. Chart LNG Vehicle Tank and Fuel System Installation Guidelines

Specifications for Arc welding Robot with Hot wire TIG welding Unit Specifications for Arc welding Robot

Hydrogen Fueling Standardization: Enabling ZEVs with "Same as Today" Fueling and FCEV Range and safety

UNCLASSIFIED FY 2017 OCO. FY 2017 Base

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Variable Intake Manifold Development trend and technology

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

TEST REPORT. The following merchandise was submitted and identified by the vendor as:

Steering Module Test Simulator SMTS

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

TECHNICAL WHITE PAPER

VTZ variable speed Reciprocating compressors

Heating Cost Allocation Valve with local acquisition of the flow temperature

Gleason Phoenix 450 Project

TEST METHODS CONCERNING TRANSPORT EQUIPMENT

MOTOR CONTROLLER SPECIFICATION

Selection Guide. Control Circuit and Load Protection

Selection Guide Motor Control Device Solutions

DORMA Automatics, Inc. 924 Sherwood Drive Lake Bluff, Illinois U.S.A. Toll Free: Fax:

ADJUSTABLE FREQUENCY CRANE CONTROLS

Electric buses Solutions portfolio

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Performance of Batteries in Grid Connected Energy Storage Systems. June 2018

Asia Pacific Research Initiative for Sustainable Energy Systems 2011 (APRISES11)

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

RULE 449 TRANSFER OF GASOLINE INTO VEHICLE FUEL TANKS

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Delivering unsurpassed quality, design and value.

Smart Grid Update Supplier Conference. Kevin Dasso Senior Director Technology & Information Strategy. October 27, 2011

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Smarter Solutions for a Clean Energy Future

Beyond 60% - Pioneering H-class Efficiency with World Class Flexibility

Transcription:

Hydrogen Station Equipment Performance Device (HyStEP Device) Specification Overview Policies and technology solutions need to be developed and implemented to help reduce the time from when a new hydrogen station is completed to when the station has been approved by all of the fuel cell electric vehicle OEMs for customer fills. The current practice of station acceptance, which burdens vehicle OEMs with serial testing of stations because each OEM conducts their own testing and evaluation, can take months. This process is not practical or sufficient to support the timely development of a hydrogen fueling station network. This is especially true in the state of California where new stations are coming online currently and as many as 35 new stations are scheduled to be commissioned in the next year and half. Ultimately, a hydrogen station test device that can be used to verify station fueling protocol according to the SAE J2601 standard, average daily and peak fueling capacity, and fuel quality would be desirable to commission new stations. In the near-term, a test device designed specifically to test station fueling protocol that is technically effective, safe, robust, and user friendly will accelerate the commissioning of CA stations. This device must be safe and robust enough to survive travel from station to station to be useful, but also simple enough to design, fabricate, assemble and implement quickly to meet the CA timetable. This project aims to develop such an alpha version device within six months of contract award, with the option to allow for later expansion to enable additional capabilities. This device will initially include one or two Type IV 70 MPa tanks capable of storing a total of 4-7 kg H2. The tank(s) will have a thermal pressure relief device and will be instrumented with pressure and temperature sensors. The tank will be connected to a 70 MPa receptacle equipped with pressure and temperature sensors and will have IrDA communications capability. All will be integrated with a data acquisition, analysis, and control system. A valve near the receptacle attached to a vent manifold will be used to both simulate a leak for fault detection tests and for controlled defueling. Additional temperature sensors will record ambient temperature near the receptacle and various external system temperatures. The station test device will be capable of performing key tests defined in CSA HGV 4.3. These include IrDA communication tests, fault detection tests, and communication and non-communication fills at 70 Mpa (H70). Additionally, the device must be capable of carrying out communication and non-communication fill tests at 35 MPa (H35). All test parameters listed in HGV 4.3 Table I will be provided in an easily accessible data file. Overall System Requirements

SAE J2601 includes fueling in ambient conditions from -40C to +50C and gas fueling temperature between -40C and +85C. The pressures for fueling are up to 87.5MPa or 1.25x NWP. However, as this is a test device to ensure the fueling meets SAE J2601, fault conditions may occur and the tank should therefore be rated above this maximum fueling limit. The tank(s) rating should follow SAE J2579 which includes cycling validation at a temperature range of -40 C to 85 C, testing up to 1.5 nominal working pressure (NWP) of 70 MPa, and a minimum 2.25 NWP burst pressure. The following system requirements for the station test device apply to the entire system with the exception of the hydrogen storage tank(s) Table 1: System Requirements Required MAWP (MPa) 96.6 Ambient Temperature Range -40 to 50 ( C) Tank Gas Temperature Range -45 to 85 ( C) Maximum Flow rate (g/s) 60 Receptacle to Tank Pressure 20 (15 to 20 preferred) drop (MPa)* * This pressure drop is defined according to J2601 as: When tank pressure is 10 MPa and fuel temperature is -15 C at the nozzle and mass flow is 1.5 x the average mass flow to fill the storage volume in 3 minutes Primary Component List Type IV 70MPa rated tank(s) compliant with SAE J2579 with a H2 storage capacity in the 4-7kg range (preferred 4.5-6.5 kg range). A single large tank is preferred. o (Option) Provide flexibility in the design and configuration of the device for additional tank(s) to be added in the future. o (Option) Provide additional tank(s) to allow for back-to-back fills and/or testing in the 7-10 kg range. Automotive-type in-tank valve that includes a check valve for fueling, a solenoid valve for defueling, and a thermal pressure relief device (TPRD) is preferred. Equivalent external components are acceptable. H70 rated SAE J2600 compatible receptacle Vehicle-side IrDA communications capability per SAE J2799 IrDA control interface with the ability to simulate signals Leak valve near receptacle for fault detection tests In-line pressure relief valve and shut-off valve In-line particle filter (< 5m) Vent manifold with flow limiter and interface for connection to station vent stack for defueling Standalone vent stack and tubing as alternative to station vent stack

If the system is enclosed, venting must be provided to prevent the accumulation of hydrogen and a hydrogen leak detector must be mounted within the enclosed space Data acquisition and analysis system with minimum sampling frequency of 10 Hz Mobile Platform: o (Option 1) System should be mounted on a trailer towable by a half ton pickup truck. Trailer suspension must prevent damage to system from shock and vibration. o (Option 2) System designed to fit into standard ½ ton, full size pick up bed (4 8 ) inside wheel wells. Recommended maximum dimensions, approximately 36 W 48 L 36 H including nozzle receptacle. Must weigh no more than 750 lbs. and lifting and mounting features must be supplied to accommodate lift truck (below) and chain lift (above). All systems should be able to withstand road vibrations, wind, rain and other forces associated with transport and field use. All electronic systems should be Class 1, Division 2, Group B. Materials of Construction All components of the device exposed to hydrogen gas (tubing, fittings, valves, instrumentation, etc.) shall be fabricated from materials compatible with high pressure hydrogen using sound engineering practices. Metal alloys shall be limited the list provided in SAE J2579 Table B2 QUALIFICATION OF HYDROGEN COMPATIBILITY BASED ON USAGE CONDITIONS. This table lists 316 and 316L stainless steel as well as several high nickel content steels and several aluminum alloys. Non-metal parts (seals, valve seats, etc.) shall be screened to ensure performance under the conditions listed in Table 1. Guidance can be found in ISO/PDTR 15916 and NSS 1740.16 from NASA as well as CSA HGV 3.1and HPRD1. Required Instrumentation Sensor Location Measurement Range Accuracy Receptacle Pressure Receptacle Temperature Tank Gas Pressure Tank Gas Temperature* Ambient Temperature In-line near receptacle In-line near receptacle In-line at tank inlet. Must be representative of pressure inside tank. At least one sensor inside tank out of gas flow path. Multiple sensors preferred. External near receptacle protected 0 to 100 MPa 0.1% of full scale -45 to 100 C ± 1 C 0 to 100 MPa 0.1% of full scale -45 to 100 C ± 1 C -45 to 55 C ± 1 C

from environmental effects External Tank External mounted to -45 to 55 C ± 1 C Temperature the outside skin of tank with thermally conductive material H2 Flow Rate (Optional)** In-line between receptacle and tank 1.5 to 75 grams/sec ± 2.5% of reading * From CSA HGV 4.3: The HDTA shall have at least one tank temperature sensor used to accurately measure the gas temperature in the tank. The sensor shall be installed inside the tank in the same end as the hydrogen supply piping and shall protrude no more than 20 cm (8 in) into the vessel beyond the neck section of the tank. Sensor shall avoid contact with the wall and out of the incoming flow path. ** A hydrogen flow meter should be quoted as an option for the project team to consider Test Requirements per CSA HGV 4.3 Will perform Communication Tests 2.2.1 through 2.2.5 o ABORT test, HALT test, data loss then ABORT, data loss and resumed fueling, and thermocouple fault Will perform Fault Detection Tests 2.3.1 through 2.3.3 o Receptacle leak at start of fueling, high pressure leak during fueling, and full tank refusal Will perform Performance Tests 2.4.1 and 2.4.2 o Communication fill and non-communication fill with Type IV tank under 7kg Will not perform Performance Tests 2.4.3, 2.4.4, and 2.4.5 Note: CSA HGV 4.3 is currently undergoing revision to be harmonized with the recently published SAE J2601 standard. Depending on timing, these test requirements may be changed to reference the new HGV 4.3 document. Data Acquisition, Analysis and Reporting The data acquisition system (DAQ) shall be designed to provide the test parameters listed in CSA HGV 4.3 Table I. These parameters will be either directly measured or calculated from directly measured quantities and saved in an Excel-compatible file format. The DAQ shall also be designed to accommodate up to 4 additional temperature sensors and 2 additional pressure gauges. A real-time data display capability shall be included that, at a minimum, will display tank pressure and temperature as well as safety-related parameters. An approved DAQ software shall be used that will allow the end user flexibility to modify calculated parameters, automated procedures and/or data acquisition rate. Parameter Description Measured Calculated Tamb Ambient temperature at the dispenser Pstart Initial tank pressure

Tstart Initial tank temperature Pmax Maximum observed tank pressure during fueling (average of 3 points) Tmax Maximum observed gas temperature in the tank during fueling (average of 3 points) Fmax Maximum fuel flow rate (Fuel flow rate will be estimated if a fuel flow meter is not included) (optional) SOC State of charge calculated 5 seconds after the end of fueling FEtime Fueling duration Ptarget Target fueling pressure Pend tank Final tank pressure (average of 3 points) P5 Tank pressure 5 seconds after end of fueling GT5 Tank temperature 5 seconds after end of fueling SOC5 State of charge 5 seconds after end of fueling P30 Tank pressure 30 minutes after end of fueling GT30 Tank temperature 30 minutes after end of fueling D30 Hydrogen density in tank 30 minutes after end of fueling SOC30 State of charge 30 minutes after end of fueling Tfuel Fuel delivery temperature GT15 Fuel delivery temperature 15 seconds into fueling APRR15 Average pressure ramp rate (averaged over 15 second intervals) APRRaverage Overall average pressure ramp rate APRRtarget Target APRR based on SAE J2601 tables DP Pressure drop from receptacle to tank PPulse Initial pressure pulse mass Post processing of the data will be required to verify compliance with SAE J2601 and NFPA 2 leak and hose checks. Data shall be available to verify the following: Parameter Definition Criteria LC Leak check at beginning of fill Verify pause, t < 15 sec. LCP20 Leak check at 20MPa intervals Verify pauses and pause times NFZ No fueling zone Tank is not filled if start conditions are in no fueling zones of J2601 tables

Ppulse Number of fueling pauses ( 10) Verify # pauses < 10 Validation Testing Prior to acceptance, the system shall be tested to ensure operability. The following tests shall be carried out at a minimum: By the device supplier: Leak check: Verify the system is leak tight at 87.5 MPa. Pressure drop shall be less than 10% over a 6 hour hold. Fitting tightness check: Torque check on all bolts/fasteners Communications check: Verify the IrDA transmitter and control unit operate as expected Safety checks: Verify the operation of all passive and active engineered safety controls and document. Final validation testing of the device will be carried out at the NREL Energy Systems Integration Facility (ESIF). The device supplier shall provide technical support and training on device operation at ESIF for a duration of one week following delivery of the device. The goal of this testing is to verify that it meets the requirements of this specification. Testing will be carried out at the ESIF facility with a research dispenser equipped for 70 MPa fueling with -40 C pre-cooling (H70-T40). All of the required tests will be carried out and test procedures will be verified per CSA HGV 4.3. Measured and calculated parameters will be recorded and checked for completeness and accuracy. All required tests will be performed multiple times to satisfy the requirements of a Gauge R&R study. The device must complete all of the required tests and produce the required data to be considered acceptable. Documentation Documentation shall be included with the device and shall include the following: A user manual including operating instructions and a troubleshooting guide will be provided upon completion of the device and prior to final validation testing. A maintenance schedule and instructions document will be provided upon completion of the device and prior to final validation testing. A final piping and instrumentation diagram that must accurately represent the as-built device Dimensioned drawings of the overall system An electrical wiring diagram The data acquisition software code, description, and instructions for modification A report summarizing the results of the HA/FMEA

An individual component parts list (Bill of Materials) and the manufacturer s documentation (if applicable) for all components All component certifications received by the contractor Leak and pressure tests of individual components and/or the entire device manifold should be documented and certifications provided. Training The device supplier shall provide technical support and training on device operation at NREL for a duration of one week following delivery of the device. Project team members will be trained on the operation of the device including troubleshooting and maintenance. Supplier representative(s) will also support initial H70-T40 tests at ESIF. Spare Parts To help ensure maximum up time in the field, the device should be delivered with a minimal amount of common, and if possible, long lead time, wear-related spare parts such as o-rings, valves, etc. Also, a list of specific tools required to repair and/or maintain the device should be included (type of torque wrench, metric tools, etc). Piping and Instrumentation Diagram Figure 1 shows a reference P&ID for the station test device. The diagram shows an example configuration with many of the key components required. The supplier shall create their own detailed P&ID diagram during execution of the project. Figure 1. Reference piping and instrumentation diagram.