Everest XV. ErP. High Efficiency HRV Fan Unit READY

Similar documents
VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

CYCLONE F 400 smoke extraction casing

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series

1/11 29/06/2016 CONTENTS 1. GENERAL DUCTS, AIR VENTS, VALVES MONOBLOCK UNITS FILTRATION CONTROL...

EVEREST XV Installation instructions EN

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

ACOUSTIC CABINET FANS FOR SUPPLY AIR APPLICATIONS CAIB/T PRO-REG Series

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

BRIZA 22 HYBRID HEATING & COOLING

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

ROOF FAN ROOFMASTER STEC

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Accessories. Series REC

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

VARYCONTROL VAV Dual Duct Terminal Boxes

Swimming Pool CSR2 Heat Recovery Equipment

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

Fan coil units MAJOR 2 CV/CH

APP EOLE4. Applicable to program versions TAC5 Version DT & DG 2.7.0

Air-Cooled Liquid Chiller with integrated hydraulic module

HEXAMOTION RANGE HEAT RECOVERY

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

DIRECT-AIR ILB / ILT Series Rectangular duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

MIRUVENT. Power roof ventilator with 27 different airflow variants up to 24,000 m 3 /h

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

Variable Air Volume Dampers

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

Fan coil unit NBS 100/150

GigaBox centrifugal fans Product specific information

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Heat recovery units type GTDHR

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

42GW. Hydronic Cassette Fan Coil Units PRODUCT SELECTION DATA INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS EASY INSTALLATION

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

EC Axial Fan Catalogue

Silent centrifugal air heater hot water supply

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Hybrid. DUTIES UP TO 0.95 m 3 /s (950 l/s) Ecovent Hybrid part of a complete range of innovative, flexible products from the HVAC experts

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

something new in the air Technical Bulletin

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

RC-DO. Room controllers with display and manual forced ventilation function

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

IN-LINE CENTRIFUGAL DUCT FANS VT Series

42N. Room Fan Coils PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Simpified installation & large options choice

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

CH5000 Heat Recovery Ventilator

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

UMXCA/UMXCBA ECVA/ECVBA

BASTONE (dual) fancoil Units

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Product Brochure Fan coil units for suspended ceilings HyPower-Geko. Energy efficient Powerful Hygienic Low noise

VAV TERMINAL BOXES TYPE: BA BT

AHN 064 to 304 EHN/CHN 064 to 304

Ceiling swirl diffusers

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Alfa Laval Optigo CS. Commercial air coolers - Slim line

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Modular fan coil unit model PS

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

DCV-SP Pressure control unit

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Air Cooled Packaged Units

VAV controller. TROX Auranor Norge AS. Telephone Fax

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

RECU-NOVO. heat recovery unit

VARIABLE SPEED WATER BOOSTER SETS WITH MULTISTAGE VERTICAL ELECTRIC PUMPS FLOW RATES UP TO 400 m 3 /h. 50 Hz GHV30 GHV40 SERIES

Transcription:

High Efficiency HRV Fan Unit ErP READY Field of application Installation Advantages Description Range Technical details Aeraulic and electrical details Acoustic specifications Aldes Smart Control system Servicing Options & Accessories

High Efficiency HRV Fan Unit Conformity EUROVENT certified air-air heat exchanger system (based on the AAHE heat exchanger programme). CE compliant. Compliant with 2016 and 2018 ErP regulations Advantages High-efficiency (>90%) HRV units. Exclusive Aldes Smart Control system. Optimal air quality and thermal comfort. Easy to install and activate. Selector software specific to Everest for product selection and performance calculations. FIELD OF APPLICATION Heat recovery ventilation for energy-efficient nonresidential buildings of all types: offices, schools, hotels, residences for the dependent elderly, etc. Filtration and preheating / cooling of incoming air. INSTALLATION Utility rooms / flat roofs. Indoors / outdoors Rectangular (or optional circular) connections. Choice of side for equipment fittings (left or right). Customised plan supplied with the machine and its accessories. DESCRIPTION 4 Everest models up to 2,300 m 3 /h. Pre-cabled monoblock units. Self-supporting construction with dual-wall panels. 50 mm mineral wool insulation. Access to all components via hinged doors on the front, and to the control system via its own dedicated central hatch. Aluminium or galvanised steel + paint coating condensate collection tray. Factory-mounted single-piece cowl for outdoor versions. Pre-lacquered steel exterior finish (RAL 9006 dark grey). M0 galvanised steel Z275 interior finishes. High efficiency counterflow plate heat exchanger (up to 90 % and more). EC motor with backward curved impeller. Adjustable 100 % bypass. G4 flat filters on exhaust air and F7 on fresh air. Built-in switch. Aldes Smart Control system: - Constant speed. - Constant airflow. - Constant pressure. Airflow control using CO2/VOC sensor (0-10V signal). - Controlled pressure. - Built-in clock: operating hours can be controlled with timer. Configuration & monitoring via: - Hard-wired remote control. - Built-in webserver. - BMS communication via ModbusTRU, Bacnet, TCP/ IP and LON (optional) protocols. Smart frost protection via controlled opening of the bypass. ErP READY UNIT CUSTOMISATION Configurable components Access panel Version Control mode Filters Additional options (delivered within the unit) Internal coils Heat-exchanger frost protection Communications system Filter clogging alarm Left or Right hand side Interior or exterior (leak-tight factory-fitted single-block roofing element). Variable speed or Constant airflow or Constant pressure or Variable airflow controlled by CO2/VOC sensor (0-10V signal) or Controlled pressure or Airflow adjusted via 0-10V signal Fresh air supply filter: F7 50 mm flat mini-fold filter as standard or F7 HE 100 mm mini-fold low-pressure loss filter as option. Optional G4 pre-filter. Exhaust air filter: G4 as standard, F7 flat 50 mm mini-fold as an option. Electrical heating coil or Hot water coil or Cold water coil* or Reversible coil* Electrical coil (frost protection via controlled opening of the standard bypass). LON (Modbus, TCP/IP, BACnet as standard) Differential pressure sensor (measures pressure loss in real time) * available starting on 1 st October 2015 2

High Efficiency HRV Fan Unit RANGE Designation Code 600 11069010 1200 11069011 1600 11069012 2300 11069013 EVEREST XV 2300 EVEREST XV 1600 EVEREST XV 1200 EVEREST XV 600 0 500 1000 1500 2000 2500 Q (m 3 /h) ACCESSORIES Designation Code 600 motorised damper 11068452 1200 motorised damper 11068451 1600 motorised damper 11068450 2300 motorised damper 11069018 600 standard flexible sleeve 11068417 1200 standard flexible sleeve 11068416 1600 standard flexible sleeve 11068415 2300 standard flexible sleeve 11068414 600 insulated flexible sleeve 11068349 1200 insulated flexible sleeve 11068348 1600 insulated flexible sleeve 11068347 2300 insulated flexible sleeve 11068346 600 rigid adapter piece 11068431 1200 rigid adapter piece 11068386 1600 rigid adapter piece 11068385 2300 rigid adapter piece 11068384 SPARE FILTER KIT Designation Code 600 F7 flat filter kit 11068458 1200 F7 flat filter kit 11068458 (x2) 1600 F7 flat filter kit 11069350 2300 F7 flat filter kit 11069354 600 G4 filter kit 11068459 1200 G4 filter kit 11068459 (x2) 1600 G4 filter kit 11069349 2300 G4 filter kit 11069353 600 F7 HE filter kit 11068457 1200 F7 HE filter kit 11068457 (x2) 1600 F7 HE filter kit 11068456 2300 F7 HE filter kit 11068455 3

1260 1260 389 638 685 435 High Efficiency HRV Fan Unit TECHNICAL DETAILS Everest general diagram Fresh air Recycling Recycling Fresh air Discharge Air supply Air supply Discharge Right panel access Left panel access Electrical connectivity and power table Model Power supply P max [W] XV 600 1 ~ 230VAC +E 50Hz 600 XV 1200 1 ~ 230VAC +E 50Hz 1100 XV 1600 1 ~ 230VAC +E 50Hz 1100 XV 2300 1 ~ 230VAC +E 50Hz 1420 Dimensions - weight Model Height (mm) Depth (mm) Length (mm) Branch connection size (mm) Connector size (mm) Weight (kg) XV 600 1260 570 1200 134 x 389 190 x 435 165 XV 1200 1260 840 1200 134 x 638 190 x 685 230 XV 1600 1500 907 1500 200 x 725 240 x 765 290 XV 2300 1730 907 1900 300 x 695 340 x 740 365 Dimensional drawings 600 134 190 1200 570 1200 134 190 1200 840 4

1730 1500 725 695 740 765 High Efficiency HRV Fan Unit Dimensional drawings 1600 200 240 907 1500 2300 300 340 907 1900 Clearance required for maintenance All components are accessible via the front panel, regardless of model. Therefore, the Everest unit can be placed against a wall or back-toback with another unit. 700 700 AERAULIC AND ELECTRICAL DETAILS Table of rated flow rates and pressures Model Nominal airflow (m3/h) Power absorbed (W) Pressure XV 600 600 500 200 XV 1200 1200 780 200 XV 1600 1600 1011 200 XV 2300 2300 1400 250 Pa MOTOR DETAILS - Single phase motor for models 1,000 to 3,500 m 3 /h (230 V AC +E) or 3-phase for models from 4,500 to 7,000 m 3 /h (400 V AC +N +E) - Integrated thermal protection. IP54 Class F, controlled by 0-10V signal Model Impeller Max. fan power (kw) Imax per fan (A) 1~200 277V or 3~380...480V XV 600 Ø225 00:24 1.7-1.25 XV 1200 Ø250 0.45 2.2-1.65 XV 1600 Ø250 0.49 2.6-1.85 XV 2300 Ø310 0.7 3.65-2.7 5

High Efficiency HRV Fan Unit AERAULIC AND ELECTRICAL CURVES Airflow range Model Pressure Max. airflow Min. airflow Reserved at max. airflow XV 600 200 650 90 18% XV 1200 200 1200 200 5% XV 1600 200 1650 250 10% XV 2300 300 2500 300 8% Curves obtained using French standard NF EN ISO 5801 P (Pa) = static pressure P (W) = power consumption. 600 800 1200 1000 700 900 P (Pa) 600 500 400 300 P (Pa) 800 700 600 500 400 200 300 100 200 100 0 100 200 300 400 500 600 700 Q (m 3 /h) 0 200 400 600 800 1000 1200 1400 Q (m 3 /h) P (W) 500 450 400 350 300 250 200 150 100 50 P (W) 1000 900 800 700 600 500 400 300 200 100 0 100 200 300 400 500 600 700 0 200 400 600 800 1000 1200 1400 Q (m 3 /h) Q (m 3 /h) 1600 P (Pa) 1000 900 800 700 600 500 400 300 200 100 2300 P (Pa) 800 700 600 500 400 300 200 100 0 200 400 600 800 1000 1200 1400 1600 1800 Q (m 3 /h) 0 500 1000 1500 2000 2500 Q (m 3 /h) 1000 900 800 700 1600 1400 1200 P (W) 600 500 P (W) 1000 800 400 300 200 100 600 400 200 0 200 400 600 800 1000 1200 1400 1600 1800 Q (m 3 /h) 0 500 1000 1500 2000 2500 Q (m 3 /h) 6

ACOUSTIC DETAILS Criteria complying with standards: - ISO 5136 sound levels in ducts - ISO 3741 radiated sound High Efficiency HRV Fan Unit Lwc asp: sound power in ducts during aspiration Lwc dis: sound power in duct during air supply Lp - db(a): sound pressure radiated at 4 m from connected casing. Frequency (Hz) 63 125 250 500 1000 2000 4000 8000 Global (db(a)) 600 (450 m 3 /h - 200 Pa) Lwc asp - db 58 68 70 72 69 61 63 62 77 Lwc sup - db 69 67 71 71 69 66 60 55 77 Lp - db(a) 23 13 13 19 20 17 <10 <10 27 1200 (1100 m 3 /h - 200 Pa) Lwc asp - db 65 71 70 71 70 65 67 71 78 Lwc sup - db 72 72 72 71 72 72 66 64 80 Lp - db(a) 25 17 14 18 23 22 13 <10 29 1600 (1500m 3 /h - 200 Pa) Lwc asp - db 56 65 67 71 70 66 68 69 77 Lwc sup - db 69 68 71 73 74 71 67 63 79 Lp - db(a) 22 12 13 20 25 22 13 <10 29 2300 (2100m 3 /h - 200 Pa) Lwc asp - db 55 64 71 70 67 65 67 68 77 Lwc sup - db 68 67 73 72 73 71 67 65 80 Lp - db(a) 21 12 16 19 24 22 14 <10 29 7

High Efficiency HRV Fan Unit FILTER DETAILS Minifold F7 filter on fresh air, pleated G4 filter on exhaust air. Filters fitted to rails to facilitate access during servicing and maintenance work Optional sensors to measure differential pressure Model Filter class Dimensions (mm)* CONDENSATE CHARACTERISTICS Total filter surface area F7 (m²) Evacuation of condensates from heat exchanger via front panel (machine access panel). Water trap required (not supplied). Further details are provided in the installation instructions. For cold water or changeover coils built into the unit: the discharge point is under the machine. Water trap required (not supplied). Further details are provided in the installation instructions. Total filter surface area F7 HE (m²) Total filter surface area G4 (m²) XV 600 G4/F7 255 x 350 01:48 2.93 00:24 XV 1200 G4/F7 2 filters 255 x 350 2.93 5.86 0.48 XV 1600 G4/F7 592 x 400 on fresh air 292 x 592 on exhaust air 3.92 2.86 7.77-0.64 0.47 XV 2300 G4/F7 592 x 592 on fresh air 400 x 592 on exhaust air 5.80 3.92 11.5-0.95 0.64 * Frame included ALDES SMART CONTROL SYSTEM General presentation Aldes Smart Control provides a wide range of possible configurations and control methods for the Everest HRV system. Configuration is possible via: - Built-in webserver (local or remote RJ45 connection to PC, MAC, smartphone, etc.) - Ergonomic remote control system (single-handed use) - BMS via ModBus TCP/IP; Modbus RTU; BACnet & LON protocols Control function Designation Menu User Advanced menu Secure access Expert* menu Secure access Functions for optimum air quality Fan control mode 6 control modes: - Constant speed - Constant airflow - Constant pressure - Airflow control using CO2/VOC sensor (0-10V signal) - Controlled pressure - Airflow adjusted via 0-10V signal Possible imbalance between inlet and extraction Slave mode possible Can be controlled via external contacts Fan set point compensation based upon exterior temperature (with coils) Timer switch Timer (week, day, hour) used to program timed operation Summer/Winter management 8

High Efficiency HRV Fan Unit Control function Designation Menu User Advanced menu Secure access Expert* menu Secure access Functionalities designed to provide optimal thermal comfort. Temperature control 3 temperature control methods - T C constant - air supply - T C constant - exhaust air - Constant difference between air supply/exhaust Possible to change controlled temperature during switch from summer to winter mode (and vice versa). Bypass control Cooling via automatic opening of the bypass according to outdoor conditions (Free cooling) - Night cooling function Heat exchanger frost protection Damper adjustment Coil control Unit monitoring functions Frost protection by controlling the opening of the bypass Smart frost protection by controlling the opening of the bypass + electrical coil Damper control Closed when stopped Coil control Frost-protection and water coil protection Temperature set point compensation based on outdoor temperature (with coils) Alarms Types - Multiple configurable alarms (including a fire alarm using an external contact, filter clogged alarm, etc.) - Alarm forwarding by e-mail Display - Current active alarms - Display of future alarms - Alarm log Verification of operational status - Real-time data on component status (filter pressure loss, etc.) - Operational data log - Data update/backup using SD cards - Override mode for components operational tests Installation Aftersales service - Unit can be reconfigured on-site: reassignment of I/Os; - Reset to factory settings - Advanced settings available for each component * Expert menu - only accessible via the webserver. 9

High Efficiency HRV Fan Unit FUNCTIONS FOR OPTIMAL AIR QUALITY Fan control modes Constant pressure Constant speed Fan pressure Pa Fan pressure Pa High pressure set point Pa Low pressure set point Pa Low speed set point % High speed set point % Principle Principle: the fan adjusts its operation to provide a constant pressure. 2 pressure set points can be used for each fan: low pressure and high pressure. Settings - Various possible configurations: - Air supply pressure set points + exhaust pressure set points - Air supply pressure set points + exhaust slaved to air supply - Exhaust air pressure set points + air supply slaved to exhaust Equipment supplied with the unit: - 2 differential pressure sensors fitted to the fans to measure airflows - 2 differential pressure sensors supplied with the unit to be fitted inside the ductwork, with RJ12 cabling (see installation guide for sensor connections). Constant airflow Fan pressure Pa Fan airflow (m 3 /h) Principle The fan operates at the same speed at all times. 2 speed settings can be used for each fan: low speed and high speed. Settings: Air supply speed set points + exhaust speed set points. Equipment supplied with the unit: No differential pressure sensor needed. Variable airflow controlled by CO2/VOC sensor Fan pressure Fan airflow (m 3 /h) Qmax Qmin Low airflow set point m 3 /h High airflow set point m 3 /h Fan airflow (m 3 /h) Low CO 2 limit set point e.g. 800 ppm High CO 2 limit set point e.g. 1100 ppm CO 2 ppm Principle The fan adjusts its operation to provide a constant airflow. 2 airflow set points can be used for each fan: low airflow and high airflow. Settings: Air supply airflow set points + exhaust airflow set points. Equipment supplied with the unit: 2 differential pressure sensors fitted to the fans to measure airflows. Principle The fan varies the airflow rate according to the CO 2 level. 2 possible threshold levels for CO 2. Settings: Exhaust controlled by a CO 2 or VOC sensor. Air supply controlled in slave mode to balance air flow rates. Equipment supplied with the unit: 2 differential pressure sensors fitted to the fans to measure airflows. Accessory: CO 2 sensor, range 0-2000 ppm, 0-10 V output signal. 10

High Efficiency HRV Fan Unit Fan control modes Controlled pressure Pmax Pmin Fan pressure Pa Set point Principle Fan controlled to ensure pressure increases alongside airflow 1 set point per fan. The unit will change the pressure set point to match the measured airflow Settings: Indicate the max. and min. airflow rates for each ductwork with their associated pressure losses. E.g. Air supply: Qmax 5000 m 3 /h Pmax 300 Pa / Air supply: Qmin 2000 m 3 /h Pmin 150 Pa Exhaust air Qmax 5000 m 3 /h Pmax 290 Pa / Exhaust air Qmin 2000 m 3 /h Pmin 145 Pa. Qmin Timer switch Weekly programming (possible for all control modes) Qmax Fan airflow (m 3 /h) Equipment supplied with the unit: - 2 differential pressure sensors fitted to the fans to measure airflow rates - 2 differential pressure sensors supplied with the unit to be fitted inside the ductwork, with RJ12 cabling (see installation guide for sensor connections inside the ducts). Principle Timed programming of set points: - Low setting, - High setting, - Stop. Settings: Example of constant airflow operation: High setting Low setting 11

High Efficiency HRV Fan Unit FUNCTIONALITIES DESIGNED TO PROVIDE OPTIMAL THERMAL COMFORT. Temperature control Air supply temperature Principle The unit is controlled to maintain a constant air supply temperature. Settings: Air supply temperature set point Equipment supplied with the unit: Air supply temperature sensor supplied already wired into the unit, to be fitted to the aeraulic ductwork. Example of use: This control method will mainly be used when the Everest unit is only used for ventilation and not for cooling and/or heating the building. The EVEREST unit ensures a constant air supply temperature defined by a set point close to the desired temperature inside the building. Variations in the temperature inside the building are handled by heating and cooling systems independently of the EVEREST unit. Temperature control Exhaust temperature Principle: The unit is controlled to maintain a constant exhaust air temperature Settings: The exhaust temperature set point is configured in the User menu; the minimum and maximum air supply temperatures are configured in the Advanced menu. Equipment supplied with the unit: Extracted air temperature sensor, delivered pre-cabled into the unit. Air supply temperature sensor supplied already wired into the unit, to be fitted to the aeraulic ductwork. Example of use: This method will mainly be used when the Everest unit is used for ventilation, cooling and/or heating the building. By adjusting the exhaust temperature you can adjust the ambient temperature. These settings therefore take into account any increases/decreases in temperature (opening a window, sunlight on windows) and adapts the cooling/heating provided by the EVEREST unit accordingly. Temperature difference between exhaust air and air supply Principle: The unit is controlled to maintain a constant temperature differential between the air supply and exhaust air. Settings: The differential setting between the air supply and exhaust air is configured in the User menu; the minimum and maximum air supply temperatures are configured in the Advanced menu. Equipment supplied with the unit: Extracted air temperature sensor, delivered pre-cabled into the unit. Air supply temperature sensor supplied already wired into the unit, to be fitted to the aeraulic ductwork. Example of use: This setting method will principally be employed when the building is fitted with a separate heating system. The air supply temperature varies with the exhaust air temperature, which in turn is related to the independent heating/cooling systems. The Everest unit is therefore slaved to the external systems. Bypass control Free cooling - Night cooling Principle: Free cooling & Night cooling involve bypassing the heat exchanger in order to use the outdoor temperature to cool the building, free of charge, during the summer. Free cooling is used to provide cooling while the unit is running. Night cooling activates the free cooling function when the fans are stopped. Operation: Everest units are fitted with an adjustable 100% bypass. Depending on the temperatures, the control system adjusts the opening of the bypass dampers to achieve the pre-set air supply temperature. If the free cooling & night cooling functions are active, the fans will run in high speed mode. Settings: The bypass is opened according to the temperatures of the exhaust air / outside air / air supply set point / timer programming. 12

High Efficiency HRV Fan Unit Frost protection for the the heat exchanger The exchanger plates cause condensation on the discharge. If this condensation takes place at a low temperature, the water can freeze and ice-up the exchanger. This icing risk is present once the exhaust temperature drops below 5 C (configurable temperature). The Everest unit has two methods of protection: - by controlling the bypass - by controlling the bypass and an electrical coil on the exhaust outlet. Smart frost-protection via bypass control Principle: This management mode involves bypassing some of the exterior air to avoid overcooling the discharged air air. Description: The use of a bypass reduces the fresh air inflow to the exchanger, therefore reducing the exchange of heat and preventing overcooling of the discharged air. The opening of the bypass is adjusted to assure a discharged air temperature > 5 C (configurable) The airflow that bypasses the heat exchanger is routed directly to the air supply outlet, thereby maintaining the inflow rate. Example: Outside temperature = -10 C No frost-protection: With frost protection using bypass control: -10 C Discharge temperature = 1 C => risk of freezing 20 C -10 C 75% airflow 25% airflow 20 C -10 C 1.4 C FROST 17 C 5 C NO FREEZING 18.5 C 11 C Smart frost protection via bypass control + an electrical coil. Principle: This frost-protection method involves: - heating the exhaust air using an internal electrical coil to prevent ice forming on the discharge - bypassing some of the fresh air to maintain a comfortable air supply temperature. Description Heating the exhaust air ensures the air discharged is > 5 C and prevents ice forming on the exchanger. Bypass opening is controlled to lower the air supply temperature, mixing the air supply from the heat exchanger with the cold outside air that has bypassed the exchanger. The air supply temperature set point is therefore respected. Example: Outdoor temperature = -10 C Air supply temperature set point to ensure frost protection = 19 C Discharge temperature = 1 C => risk of icing Discharge temperature = 1 C => risk of icing The coil is activated so that the discharge temperature > 5 C Outside air bypasses the exchanger to obtain the required air supply temperature. With coil frost-protection: 30% airflow -10 C 20 C -10 C 70% airflow 33 C kw 20 C -10 C 1.4 C 17 C 17 C No risk of freezing as discharge temperature > 5 C 31.5 C 19 C Temperature set point reached 13

Damper adjustment High Efficiency HRV Fan Unit Principle: The dampers are used to prevent the circulation of air inside the unit when it is stopped. The dampers are motorised and they operate in conjunction with the fans. The damper servomotor is fitted with a return spring, allowing the damper to close if there is an electricity blackout. Coil control Principle: The Aldes Smart Control system controls the coils directly. Operation: The electrical coil is activated proportionally by a 0-10V signal transmitted by the control system. Equipment supplied with the unit: Coil built into the unit, pre-cabled and ready for connection to the power supply. UNIT MONITORING FUNCTIONS Communications method Water coil Principle: The Aldes Smart Control system operates the valve. Operation: The valve is controlled proportionally by a 0-10V signal transmitted by the control system. The water coil is supplied with a temperature sensor to be fitted into the water return circuit. Depending on the temperature of the returning water, the control system will activate the coil frost-protection function: valve opened to maximum. In the event of an extreme temperature, the control system will shut down the fans. Equipment supplied with the unit: Coil delivered built into the unit. Valve supplied, circulator and temperature sensor to be cabled and fitted to the water return circuit. General information: The Aldes Smart Control system provides a multitude of possible methods for controlling the unit. Fire alarm An external contact is available to set the unit to 'fire' mode. This enables a dedicated control mode (e.g. unit shutdown), when a fire alarm is transmitted to the Aldes Smart Control System. Backup Reset to factory settings. Save to a PC or SD Card, the control parameters used when installing the equipment. Component status readings Real-time data on component status Examples: speed (%) of each fan, set-points, temperature of each sensor, status of dampers, loss of pressure through filters, coil states, etc. Web server Aldes Smart Control ModBus RTU TCP IP PC Smartphone Remote control BMS 14

High Efficiency HRV Fan Unit MAINTENANCE RECOMMENDATIONS To ensure correct operation of the ventilation system, we recommend that the equipment is inspected and maintained by a suitable provider. This maintenance is facilitated by following the indications for the installation and assembly of the equipment. All elements requiring intervention (filters, fans, heat exchanger) are easily accessible via the two removable hinged panels. For rapid tool-free interventions, filters and coils are fitted to rails. The fan motor unit is fixed in place using a quick-release system. Element 1 month 6 months 1 year Filter Inspection + Potential replacement Replacement Fan Inspection + dust removal Dust removal (if necessary) Coil Inspection Inspection + dust removal (if necessary) Dust removal + verification of safety thermostat on fan motor OPTIONS & ACCESSORIES F7 filter (50 mm) - on exhaust air or fresh air As an option, it is possible to fit the unit with a low-pressure loss F7 filter. Mini-fold filter with an increased surface area (dihedral filter): - Initial pressure loss lower than flat filters - Larger filtration surface area - Longer service life (for equal pressure loss, improved dust retention). Element Filter class Dimensions (mm) Total filter surface area F7HE (m²) XV 600 F7 255 x 350 01:48 XV 1200 F7 2 filters 255 x 350 2.93 XV 1600 F7 592 x 400 on fresh air 292 x 592 on exhaust air 3.92 2.86 XV 2300 F7 592 x 592 on fresh air 400 x 592 on exhaust air 5.80 3.92 F7 HE filter (100 mm) - on fresh air Model Filter class Dimensions (mm) Total filter surface area F7 (m²) XV 600 F7 255 x 350 2.93 XV 1200 F7 2 filters 255 x 350 5.86 XV 1600 F7 592 x 400 7.77 XV 2300 F7 592 x 592 11.5 Pre-filter (50 mm) - on exhaust air or fresh air Model Filter class Dimensions (mm) Total filter surface area G4 (m²) XV 600 G4 255 x 350 00:24 XV 1200 G4 2 filters 255 x 350 0.48 XV 1600 G4 592 x 400 on fresh air 292 x 592 on exhaust air 0.64 0.47 XV 2300 G4 592 x 592 on fresh air 400 x 592 on exhaust air 0.95 0.64 15

High Efficiency HRV Fan Unit Internal electrical heating coil Description: - AISI 304 stainless steel heating element. - Manual and auto-reset safety thermostat - Proportional control (0-10V) Installation - Pre-cabled coil - PSU 3 x 400 V AC 50 Hz +N +E (see installation instructions for connections) Power table Model Pw (W) XV 600 1700 XV 1200 3400 XV 1600 5650 XV 2300 7500 Internal water coils Description: Single row hot water coil or cold water/reversible or hot water high power dual-row coil; - Aluminium fins - Galvanised steel frame Motorised (24 V) 3-way valve, proportional control via 0-10 V signal (supplied). Model Airflow (m 3 /h) Type XV 600 450 Coil 1 XV 1200 2300 Coil 1 XV 1600 1500 Coil 1 XV 2300 2000 Coil 1 Air Coil inlet conditions T int. = 17 C 14 % HR T int. = 17 C 14 % HR T int. = 17 C 14 % HR T int. = 17 C 14 % HR Water Coil inlet conditions Nbr of tubes Nbr of rows Coil 1 = Hot water coil Coil 2 = high power hot water coil or cold water coil or changeover coil. Installation - Coil delivered pre-fitted into the unit. - Structure pre-drilled for coil water supply pipes. - 3 way valve supplied with the unit, to be installed outside of the machine. - See installation instructions for connections. Nbr of circuits Temp. air Humidity supply C % HR Power kw incl. P sensitive kw Water flow l/h m/s Water pressure loss kpa Water-air pressure loss Pa Ext. collector ø Water: T int 60 C / T out 40 C 6 1 1 28.2 1.58 80.00 0.35 2.2 1 13 14 14 Water: T int 60 C / T out 40 C 6 1 1 28.1 3.13 140.00 0.61 2.6 3 17 14 14 Water: T int 60 C / T out 40 C 10 1 2 28.2 5.58 250.00 1.09 2.5 2 15 14 14 Water: T int 60 C / T out 40 C 14 1 2 28.2 8.05 350.00 1.53 2.6 6 15 14 14 16

High Efficiency HRV Fan Unit Electrical frost-protection coil Description: - AISI 304 stainless steel heating element. - Manual and auto-reset safety thermostat - Control via SSR relay Installation - Coil supplied pre-cabled with control system - PSU 3 x 400 V AC +N +E 50Hz - See installation instructions for connections Power table Model Pw (W) XV 600 1700 XV 1200 3400 XV 1600 5650 XV 2300 7500 Filter clogging alarm 2 differential pressure sensors measuring the losses caused by the filtration of the fresh and exhaust air in real time. With this system we can instantly see the filter clogging level, as opposed to a simple pressure switch, which is only triggered when the filter is totally clogged. The fitter defines a threshold pressure loss level, upon which the unit will transmit a 'change filter' warning message. The clogging threshold level can either be a pressure loss level (e.g.: 60 Pa) or a maximum increased percentage of pressure loss compared to the new filter levels (e.g.: 50 %). Damper Description: - Motorised damper on fresh air and exhaust air with 24 V actuator fitted with return spring. Installation See installation instructions for fitting & connections. Dimensions Model Length (mm) Height (mm) XV 600 405 160 XV 1200 655 160 XV 1600 735 210 XV 2300 710 310 17

High Efficiency HRV Fan Unit EVEREST SELECTOR Principle Aldes has developed the Everest Selector software to help you choose your high-efficiency Everest HRV unit. In just a couple of minutes you can define your technical and economic choices, and put together a complete technical dossier for your clients or to integrate into your specifications manuals. 1. Integrating all the components required for your project. Your operational restrictions and the summer/winder temperature data Your options: preheating, post-heating, post-cooling, filter efficiency, etc. Additional information relating to your required configuration: Active silencers, dampers, etc. Using powerful algorithms, the Selector Everest software can find the perfect unit for your needs in just a few seconds. 2. Obtain a complete technical dossier. The performance stats of your unit (efficiency, SFP, etc.) as well as a general plan CAD plans and wiring diagrams The technical and commercial documentation for the product Regulatory texts Costing in just a few clicks Download, save and distribute your technical dossier. The advantages of the Everest Selector software - Intuitive, 4-step interface with interactive flowcharts - Rapid data entry and loading - Visualisation of all units for a project - Multi-project management - Transmission of technical dossiers by e-mail Start your design work right now: The Everest Selector software can be downloaded free of charge, from www.aldes.fr, Professional section, under the heading "Software" (Logiciels). 18

High Efficiency HRV Fan Unit Schéma général 5 1 4 6 8 7 3 2 9 1 Casing 2 Fan 3 Heat Exchanger 4 Bypass 6 Filters 7 Coil connections 8 Electrical heating coil 9 Condensate discharge 5 Aldes Smart Control System 19

High High Efficiency HRV HRV Fan Fan Unit Unit EVEREST XV Field of application Heat recovery ventilation for energy-efficient nonresidential buildings of all types: offices, schools, hotels, residences for the dependent elderly, etc. Filtration and preheating / cooling of incoming air. Installation Utility rooms / flat roofs. Indoors / outdoors Rectangular (or optional circular) connections. Choice of side for equipment fittings (left or right). Customised plan supplied with the machine and its accessories. Advantages High-efficiency (>90%) HRV units. Exclusive Aldes Smart Control system. Optimal air quality and thermal comfort. Easy to install and activate. Selector software specific to Everest for product selection and performance calculations. ALDES AÉRAULIQUE - Head Office: Tel: +33 4 78 77 15 15 - Fax: +33 4 78 76 15 97 ALDES INTERNATIONAL - Tel: +33 4 78 77 15 34 - Fax: +33 4 78 77 15 56 Everest_XV_Tech_Corp_Gb_1-08/2015 - RCS Lyon 956 506 828 - Aldes - Aldes reserves the right to modify its products at any time to introduce new technologies. www.aldes.com