Field Test of Green Base Station Designed for Environmental Friendliness and Reliability during Disasters. Research Laboratories

Similar documents
NTT DOCOMO Technical Journal. Kazuhiro Komiya Takashi Furutani Masaki Nakamura Yurie Mura Takayuki Tamura. 1. Introduction

Development of Emergency Train Travel Function Provided by Stationary Energy Storage System

Construction of power supply system using electric vehicle for stable power delivery from PV generation

Prototype Micro Fuel Cell for FOMA Terminals

Development of Power Conditioner with a Lithium Ion Battery

Panasonic Develops Industry's First *1 Nickel-Cadmium Battery Operable at Minus 40 C

Increasing community demonstration smart-grid projects involving consumers

Technology from the New Product SANUPS K for a Smart Grid Society

THE BUSINESS CASE FOR INDUSTRIAL-SCALE BATTERIES

Optimum Operation Control of Distributed Energy Resources Using ENERGYMATE-Factory

April 25, 2013 FOR IMMEDIATE RELEASE

Grid Modernization - Integration of Storage

Development of the SANUPS P73K Power Conditioner with Peak Power Cut Function

Development of Higher-voltage Direct Current Power Feeding System for ICT Equipment

Development of Catenary and Batterypowered

NAS batteries for Technical Challenges with Renewable Energy

Evaluation of photo voltaic generating system performance for fishing light application

January 28, 2015 Mitsui Fudosan Co., Ltd. NGK INSULATORS, LTD.

TECHNICAL ISSUES IN DEVELOPMENT OF A VARIABLE HYBRIDITY FUELCELL LOCOMOTIVE

Market Drivers for Battery Storage

Study of techniques for inter-regional comparison about air temperature sensitivity of electric power supply

Design and Installation of A 20.1 kwp Photovoltaic-Wind Power System

Off-grid Power for Wireless Networks. Training materials for wireless trainers

Focusing on Electric Double Layer Capacitors

The evaluation of endurance running tests of the fuel cells and battery hybrid test railway train

Development of Compact & High Efficiency Polymer Electrolyte Fuel Cell System for Enclosed Spaces

Development and Demonstration of Redox Flow Battery System

A STUDY ON A SUPPLY-DEMAND SIMULATION MODEL FOR THE STAND-ALONE HYBRID POWER SUPPLY CONSISTING OF FUEL CELL AND ENERGY CAPACITOR SYSTEMS

Corresponding Author, Dept. of Mechanical & Automotive Engineering, Kongju National University, South Korea

Investigation of CO 2 emissions in usage phase due to an electric vehicle - Study of battery degradation impact on emissions -

Metal-air batteries. Joan Gómez Chabrera Alejandro Andreu Nácher Pablo Bou Pérez

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

Combining Wind Electricity with Storage in Electric Vehicles

Microgrid System for Isolated Islands

Energy Storage (Battery) Systems

Stationary Batteries OPzS Cells

There are several technological options to fulfill the storage requirements. We cannot use capacitors because of their very poor energy density.

Mathematical Model of Electric Vehicle Power Consumption for Traveling and Air-Conditioning

Demonstration Project utilizing Hybrid Storage Battery System in the Oki-islands

Remarkable CO 2 Reduction of the Fixed Point Fishing Plug-in Hybrid Boat

10 MINUTE LTO ULTRAFAST CHARGE PUBLIC TRANSIT EV BUS FLEET OPERATIONAL DATA - ANALYSIS OF 240,000 KM, 6 BUS FLEET SHOWS VIABLE SOLUTION"

Technology of Estimating Short Circuit Current and Ground Fault for Direct Current Distribution Systems

MATERIAL SAFETY DATA SHEET Page 1 of 5 MSDS#: BA

Innovative Uses of Nickel. Joint Study Groups Seminar New & Innovative Applications for Metals. 28 April 2010 Lisbon, Portugal

Batteries generally classifies into two main groups: primary and secondary battery types. Primary batteries are

EXPERIMENTAL STUDY ON EFFECTIVENESS OF SHEAR STRENGTHENING OF RC BEAMS WITH CFRP SHEETS

Use of Aqueous Double Layer Ultracapacitor using Hybrid CDI-ED Technology for the use in Hybrid Battery Systems

Is there really anything wrong with it? Generation II 2007 Toyota Prius 311,000 miles

PRODUCT SAFETY DATA SHEET

PRODUCT SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET & IATA T1 T8 CERTIFICATE. Model(s): AM

Guidelines for Battery Electric Vehicles in the Underground

Redflow Telco Application Whitepaper

sonnen Energy Storage Presented by Boris von Bormann, CEO, sonnen, Inc. 2

Toyota Environmental Challenge 2050

Supercapacitors: A Comparative Analysis

Unit 13 Batteries and Other Electrical Sources

An energy storage and rapid charge system using EDLC for the Solar Light Rail

Energy Storage Advancement

MATERIAL SAFETY DATA SHEET Page 1 of 5 MSDS#: BA

Special edition paper Development of an NE train

Solar Storage Technologies Part of the BRE Trust

Specifications and schedule of a fuel cell test railway vehicle. T. Yoneyama, K. Ogawa, T. Furuya, K. Kondo, T. Yamamoto

Technology for Estimating the Battery State and a Solution for the Efficient Operation of Battery Energy Storage Systems

CSIRO Energy Storage Projects: David Lamb Low Emission Transport Theme Leader

Course of development of the lithium-ion battery (LIB), and recent technological trends

Cultivating New Business Based on the Spread of EVs - Marubeni s Graphite Business in Mozambique

The Great East Japan Earthquake and Lessons Learned ~Oil and Electricity~

Battery-powered Drive Systems: Latest Technologies and Outlook

Functional PCS power supply system with EV battery storage for stable PV power delivery

Development of New Model Residential PEMFC micro-chp Systems

EV market trends and outlook Shift Up a Gear

HYDROGEN ON TRACK. Andreas Hoffrichter. Doctoral Researcher University of Birmingham 4 th of July 2012

Conference on, Article number 64020

A Structure of Cylindrical Lithium-ion Batteries

Lithium-Ion Battery Simulation for Greener Ford Vehicles

CHAPTER 7 ELECTRIC VEHICLE CHARGING FACILITIES

A Study of Triangle Current Charge Method in Ni-MH Battery

A Portable Photovoltaic Powerplant for Emergency Electrical Power Supply in Disaster Affected Areas

HOMER OPTIMIZATION BASED SOLAR WIND HYBRID SYSTEM 1 Supriya A. Barge, 2 Prof. D.B. Pawar,

Components for Powertrain Electrification

Solar System Battery Backups for Reactor Coolant Pumps During Electricity Outages Resulting from Natural Disasters

Cathode material for batteries the safe bridge to e-mobility

Investigation of Solar Energy Applications with Design and Implementation of Photovoltaic Traffic Light Signal System for Qatar

Batteries: Stored Energy Discussion Questions:

B&B Power. We hope to establish a long-term business relations with you

Title Goes Here and Can Run Solar Photovoltaic up to 3 lines as shown here Systems as you see

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

MATERIAL SAFETY DATA SHEET SECTION 1 MANUFACTURER S INFORMATION SECTION 2 MATERIALS AND INGREDIENTS INFORMATION

StorEdge Solar and Energy Storage System Review

Train traffic control system on the Yamanashi Maglev test line

Use of Aqueous Double Layer Ultracapacitor using Hybrid CDI-ED Technology for the use in Hybrid Battery Systmes

Initial Project and Group Identification Document. Senior Design I EEL Off-Grid Clean Energy Power Generation

Course Syllabus and Information

Optimal Design of PV-Fuel Cell Hybrid Power System for Rural Electrification

Wave Power Generating Ships

A STUDY ON ENERGY MANAGEMENT SYSTEM FOR STABLE OPERATION OF ISOLATED MICROGRID

EENERGY EFFICIENCY. German-Japanese Energy Symposium Lithium-Ion-Technology in mobile und stationary applications. February 10 th, 2011

Battery technologies and their applications in sustainable developments. Dr. Denis Y.W. Yu Assistant Professor School of Energy and Environment

Investor Open Day 2017 The Olde House, Cornwall, 25 October Scott McGregor, Chief Executive Officer

Transcription:

Green Base Station Solar Power Generation Remote Control Field Test of Green Base Station Designed for Environmental Friendliness and Reliability during Disasters NTT DOCOMO Technical Journal 1. Introduction After the Great East Japan earthquake, NTT DOCOMO announced its intention to create a Green base station in May of 2011 - an environmentally friendly mobile telephone base station designed to withstand disasters. In March of 2012, operations such as solar panel were tested using a prototype green base station in NTT DOCOMO s R&D center [1]. To deploy commercial versions of the green base station, solar panel characteristics, and large capacity battery charging characteristics must be evaluated in an actual mobile base station under a range of weather conditions. To those aims, we began field testing green base stations in April of 2013 by installing extra green base station facilities in operational mobile telephone base stations in three locations (Kanagawa prefecture, Tokyo and Yamanashi prefecture), once stability of the operating green base station facilities had been confirmed in the R&D center. In this article, we describe the advantages of the green base station and its structure, provide an overview of the field test sites in which green base stations were installed, and discuss the effects of solar panel characteristics. Research Laboratories Kazuhiro Komiya Takashi Furutani Takafumi Yamauchi Kazuhiko Takeno 2. Green Base Station Structure Figure 1 shows the green base station structure. In contrast to existing mobile telephone base stations that normally use commercial, or use battery during a disaster (during a blackout), green base stations are designed to use an independent and environmentally friendly source (mainly solar ) both under normal conditions and during disasters. As shown in Fig. 1, a green base station can be achieved by adding the facilities shown in the green frame to an existing mobile telephone base station. Structural elements of the green base station facility are shown below. (1) Solar panels Solar panels with more capacity than the consumed by the base stations were installed for the green base station field tests. If the solar panels are positioned to collect sufficient sunlight, the mobile telephone base stations can run on solar panels alone. (2) Large capacity cycle-type* 1 batteries Large capacity cycle-type batteries with more than twice the storage capacity of the float-type* 2 lead batteries* 3 used in existing mobile telephone base stations were installed in the green base 2014 NTT DOCOMO, INC. Copies of articles may be reproduced only for personal, noncommercial use, provided that the name NTT DOCOMO Technical Journal, the name(s) of the author(s), the title and date of the article appear in the copies. *1 Cycle-type: A battery system involving cyclic charging and discharging. *2 Float-type: A type of battery that charges as is supplied to the load, and discharges during a outage. *3 Lead battery: A battery that uses lead materials for the positive and negative electrodes. These are inexpensive compared to other types of battery, but are large and heavy. 48 NTT DOCOMO Technical Journal Vol. 16 No. 1

Green base station facility (1) Solar panel NTT DOCOMO Technical Journal Power company Alternating current (AC) Existing base station facility Rectifier Direct current (DC) Direct current (DC) stations (nickel hydride batteries* 4 and lithium ion batteries* 5 ). These batteries provide backup to the base station for a long time (from14 to 16 hours), and are space-saving. (3) Green controller The green controller installed in the green base stations can be operated by remote control to combine the three sources used in the base station (commercial, solar and battery ). The controllers also enable visualization of such as the amount generated by the solar panels and the amount remaining in batteries. Green base station operations differ from existing mobile telephone base stations in that large capacity cycle-type batteries are always actively used. Following are examples of control. Peak shift control During fine weather in the daytime, communications can be ensured with mobile telephone base stations operating on electricity generated by solar panels alone. If more is generated than required by the base station during the day, (3) Green controller 3 Facility mode: Solar panel priority mode (Power generated by solar panel runs base station and charges batteries) Discharge (2) Large 2 capacity cycle-type battery Figure 1 Green base station structure Charge Existing base station facility Mobile phone base station Direct current (DC) the extra is stored in the batteries for use at night. Night-time usage control Using cheap off-peak available at nighttime to charge batteries and then using that battery during the following day can reduce base station costs. The green controller enables direct current generated by solar panels to be used as it is, which reduces loss - losses that result from converting direct current to alternating current (approximately 10% of all ), thus enabling more efficient usage. Increasing the number of green base station facilities has the following advantages. *4 Nickel hydride battery: These batteries use nickel for the positive electrode and solid metal hydride for the negative electrode (a hydrogenstoring metal). These batteries are very safe because both the electrolyte and electrodes are non-flammable. *5 Lithium ion battery: These batteries use metallic lithium oxide for the positive electrode and carbon for the negative electrode, and are characterized by their high energy density and low self discharge. NTT DOCOMO Technical Journal Vol. 16 No. 1 49

(a) Environmental friendliness Because ecologically-friendly can reduce the amount of commercial used - that since the Great East Japan Earthquake is increasingly reliant on fossil fuels for - these systems can contribute to a reduction in environmental load. (b) Reliability during disasters Even if commercial supplies to mobile telephone base stations stop during a disaster, the mobile telephone base station can operate on generated by solar panels alone, ensuring mobile telephone communications during the day. Furthermore, this system is designed with large capacity cycle-type batteries to supply backup for a long time to the mobile telephone base station when solar panels cannot supply such as night-time. 3. Green Base Station Field Tests Photographs and facility specifications for the three mobile telephone base stations fitted with the green base station facilities for the field tests (Kanagawa, Tokyo, Yamanashi) are shown in Photo 1 and Table 1 respectively. In all three field test sites, the amount of electricity generated by the solar panels installed surpassed the amount of electricity consumed by the base station. Hours of backup entailed design values determined by the base station consumption at each site, and the battery capacity that could fit into the installation space. Below are descriptions of each field test site. (1) Kanagawa field test site Because this was a relatively spacious site, it was well suited for solar panel installation. This site has the highest solar capac- (1) Kanagawa (2) Tokyo (3) Yamanashi Photo 1 Green base station field test sites Table 1 Specifications for Green base stations installed at field test sites Kanagawa Tokyo Yamanashi Base station consumption Approx. 2.0 kw Approx. 0.7 kw Approx. 1.0 kw Solar capability 4.2 kw 1.7 kw 1.4 kw Battery type Lithium ion Nickel hydride Lithium ion Battery capacity 32 kwh 9.8 kwh 16 kwh Hours of backup Approx. 16 hours Approx. 14 hours Approx. 16 hours 50 NTT DOCOMO Technical Journal Vol. 16 No. 1

ity of the three sites. Solar panels at this site have the capacity to generate more than twice the amount of consumed by the base station, making it possible to charge batteries with the excess while the base station is operating in fine weather. The facility was designed for about 16 hours of backup using 32 kwh of lithium iron battery capacity. (2) Tokyo field test site Because this was an urban site, solar panels had to be installed in an almost completely flat position in consideration of adjacent environments (the solar panels were also given antiglare treatment). Nickel hydride batteries provide about 14 hours of backup for the 0.7 kw facility load. (3) Yamanashi field test site This site is in a mountainous area that has had solar panel facilities since 2001. In this test, the solar panels were updated for direct current connection, and large capacity batteries and a green controller were included in the facility to create a green base station. With 16 kwh capacity lithium batteries, this station is designed to have the same amount of backup time as the facility in Kanagawa. Each field test site is remote-monitored from the NTT DOCOMO R&D Center via a mobile data terminal installed at each facility. Figure 2 shows field Fine (September 27, 2013) Solar Cloudy (September 22, 2013) test results for the Tokyo site as an example. The figure shows how much was independently secured () by solar in fine, cloudy and rainy weather conditions over one day during September 2013 (for a 24 hour period including night time). The self-supplied does not involve the use of commercial. Therefore, the portion of self supply is the same as the portion of commercial reduction (reduction in electricity charges). Being autumn, there were about 12 hours of daylight from sunrise to sunset, thus, these portions would be twice the values noted in Figure 2 during the 12 daylight hours under each of the weather conditions. In other words, during the daytime in fine weather, about 60 to 70% of electricity can be by solar. As a result of these tests, we were able to raise daily capacity in fine weather by about 1/3 at the test site by including control mechanisms to preferentially use solar panel. 4. Conclusion By the end of November 2013, NTT DOCOMO had built a total of 10 stations under different climatic conditions along the Pacific Coast, along the Sea of Japan Coast and inland in the Kanto-Koshinetsu region. We plan to continue to collect data from the green base station field test sites, and use it to further advance designed for control optimization. Solar Rain (September 15, 2013) Solar Solar : 5.4 kwh : 10.9 kwh Approx. 33 % of Solar : 4.0 kwh : 12.3 kwh Approx. 24 % of Solar : 1.3 kwh : 15.0 kwh Approx. 8 % of Figure 2 Example of data gathered from Tokyo field test site NTT DOCOMO Technical Journal Vol. 16 No. 1 51

Moreover in future, we intend to diversify our lineup of green base station sources with wind and fuel cells* 6 etc, and strengthen our approaches to creating mobile telephone base stations that are environmentally friendly and disaster resistant, by continuing to study optimized source operations through the green controller, and at the same time finding ways to lower costs associated with installing and operating additional green base station facilities. REFERENCES [1] K. Komiya et al.: Environmentally-Friendly, Disaster-Resistant Green Base Station Test Systems, NTT DOCOMO Technical Journal, Vol. 15, No.1, pp. 35-41, Jul. 2013. *6 Fuel cells: Cells that generate electricity through a chemical reaction between hydrogen and oxygen. 52 NTT DOCOMO Technical Journal Vol. 16 No. 1