Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

Similar documents
A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

HVAC Drives Lenze AC Tech MCH Series Price Book May US Dollars

Sensorless Vector Drives

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

WARREN COUNTY, N.Y. M/E REFERENCE

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Lift Station Design Standards and Details. Summary of Revisions

Delta Products VFD CP2000 Bypass Control Packages.

ACH550 VARIABLE FREQUENCY DRIVES FOR HVAC APPLICATIONS

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

HVW701 HVAC Drive with By-Pass

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

ROBICON W120 enclosed drive

BAC Custom Engineered Controls

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

EPS-ECONOMY PUMP STARTER

VS1PFB 230V, 50/60 Hz, 3-Phase

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

SP600 AC Drives MODIFIED STANDARD V*S DRIVES SP600 Drives: 480 VAC (3)

Submittal Data Information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

SECTION PANELBOARDS

CITY OF WEST PALM BEACH

SED2 VFD NEMA Type 3R and Type 3R Harsh Environment (3RHE) Bypass

SECTION MOTOR CONTROL

SECTION 16483C ADJUSTABLE FREQUENCY DRIVE - CLEAN POWER (CPX)

VARIABLE FREQUENCY DRIVES

CTi Automation - Phone: Fax: Web:

P-SERIES VFD WITH BYPASS

Electronic Bypass Controller

Variable Frequency Drives

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Horizontal Circuit Switchers

RVS-DN Digital Reduced Voltage Motor Starter

Horizontal Circuit Switchers

SECTION MOTOR CONTROLLERS

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

RVS-DX Digital Reduced Voltage Motor Starter

SECTION MOTOR CONTROLLERS

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

Variable Speed Product Line

Features and Benefits. Control Features

HVAC-R Drive Products

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

Buildings. Product Name. THE SMART CHOICE FOR ENERGY SAVINGS. SmartVFD HVAC and BYPASS

Compact Circuit Protector (CCP)

Submittal Data Information

Description 1/8-7.5HP

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

Compact Circuit Protector (CCP)

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

ADJUSTABLE FREQUENCY CRANE CONTROLS

Reduced Voltage Starters Section 2

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Reduced Voltage Starters

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

BUSWAY Low Voltage (Pow-R-Flex)

Series A DC Link Chokes

JC-VSD FP Series II Drives Product Bulletin 1

Motors Automation Energy Transmission & Distribution Coatings EDP11. Enclosed Drive Panel USA EDP11

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

NC State University Design and Construction Guidelines Division 23 Energy Management

Solid State Starters. Standard and Combination Packages. NEMA 4/ 12 Units are Designed for Crusher Applications

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

BROCHURE. ABB drives for HVAC applications ACH550, 1 to 550 Hp

EPS-ECONOMY PUMP STARTER

.3 Section Waste Management and Disposal.

C E R T I F I C A T E O F C O M P L I A N C E

AC Drives Selection Guide

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

Transcription:

4 Project:_ Engineer:_ Mitsubishi Electric Automation, Inc. (MEAU) Variable Frequency Drives - HVAC System Submittal Summary Data Form NEMA 1 Bypass Systems Architect:_ Contractor:_ Submitted by: Date: Tag # Model # HP Rated Voltage Rated Current Standard Features The Mitsubishi Variable torque VFD system consists of the following standard features: NEMA 1 commercial construction with hinged cover. FR-F700 VFD with PWM control, RS-485 / Modbus RTU communication, & carrier frequency up-to 14.5KHz. The VFD includes EMC/RFI filter, 3 sets of user adjustable skip frequencies, PID, and choice of 0-5Vdc, 0-10Vdc or 4-20mA speed reference. VFD parameter unit for keypad entry and display. Disconnect {Optional Circuit Breaker or Fused Disconnect} for input power with provisions for three (3) padlocks. 3 contactor bypass allowing for positive disconnect of power to the VFD when in bypass and sequencing of output power based on operator selection. Damper end switch input and damper actuator output. E-Stop string with provisions for N.C. contacts. Catch a spinning load / Windmill start activated. A control transformer, with primary and secondary fusing. Bypass controller with LCD display of operation status Display includes, but not limited to: VFD MODE REAL-TIME CLOCK CURRENT DATE BYPASS TYPE SYSTEM OFF RUN CLOSED RUN OPEN RUN HOURS BYPASS MODE BYPASS FAULT I/O SCREEN FORCED RUN TEST MODE BYP HOURS VFD FAULT VERSION CONTROL Class 20 equivalent motor overload protection. VFD rated at 100KAIC. Convenient pushbutton selection of operator information and displays. Convenient power entry and exit from bottom of the panel with generous contractor wiring area. Wall mount enclosure with narrow footprint, no dead space required between systems. DC Link Choke {Optional 3% or 5% Input line reactor} to provide input impedance, power factor improvement and surge suppression. Wiring diagram for as-built system provides concise data for easy installation and serviceability. All internal wiring is individually marked and numbered with clearly printed labels. System hour meter, non-resetable, that will track the total motor run hours in any mode of operation. System hour meter, resetable, that will track the total motor run hours for maintenance intervals. A control circuit terminal strip, featuring replaceable terminals, shall be provided for simple contractor connections and shall be isolated from line and ground. 2 year warranty UL508A Industrial Control Panel. www.meau.com 1/8 F72-091-SLSMKTG-001-A

Selection HP 1 2 3 5 7.5 10 15 20 25 30 40 50 60 200-240V Class 460-480V Class Input: 3 Phase Output Voltage: 3 Phase 200-240V at 60Hz Voltage Tolerance: 170-264V FLA 4.6 7.7 10.5 16.7 25 34 49 63 77 93 125 FLA 4.2 - - - - 7 9.6 15.2 23 31 45 58 70 85 114 Input: 1 Phase/ 3 Phase Output Voltage: 3 Phase 380-480V at 50/60Hz Voltage Tolerance: 323-528V at 50/60Hz +110% OL / 1min 120% OL / 1min 110% OL / 1min 120% OL / 1min 120% OL / 3 sec 150% OL / 3 sec 120% OL / 3 sec 150% OL / 3 sec 77 70 77-75 - - 116 106 The chart below illustrates the meaning of each character in the bypass system part number. All Mitsubishi VFD s are current rated devices for variable torque loads. The power ratings (HP, amperage) referenced in this document are for 4 pole motors. Always ensure the VFD has a continuous current rating greater than or equal to the motor s full load amps (FLA). FLA 2.3 3.8 5.2 8.3 12.6 17 25 31 38 47 62 FLA 2.1 3.5 4.8 7.6 11.5 16 23 29 35 43 57 www.meau.com 2/8 F72-091-SLSMKTG-001-A

System dimensions: 208V: 1, 2, 3 & 5 HP Weight: 70lbs 460V: 1, 2, 3, 5, 7.5 & 10 HP www.meau.com 3/8 F72-091-SLSMKTG-001-A

System dimensions: 208V: 7. 5, 10 & 15 HP 460V: 15, 20 & 25 HP Weight: 150lbs \ www.meau.com 4/8 F72-091-SLSMKTG-001-A

System dimensions: 208V: 20, 25 & 30 HP 460V: 30 & 40 HP Weight: 200lbs www.meau.com 5/8 F72-091-SLSMKTG-001-A

System Dimensions : 208V 40HP 460V 50, 60, 75HP www.meau.com 6/8 F72-091-SLSMKTG-001-A

Bypass Schematic www.meau.com 7/8 F72-091-SLSMKTG-001-A

460V 208V Voltage Submittal Summary System Hp *1. Requires upstream branch circuit protection. Mitsubishi Electric Automation Pow-R-Gate Electrical Data Disconnect Circuit Breaker Fused Disconnect Amps AIC (*1) Amps AIC (*1) Switch Max Amps Fuse Amps Fuse Class AIC DC Choke 3% reactor 5% reactor Overload O/L Range O/L preset 1 30 50kA 6 10kA 30 8 CC 200kA DCA001203 12A, 5mH MRL-00401 4A, 3mH MRL-00402 4A, 6.5mH TH-N12(CX)KPUL5.0A 4.0-6.0A 4.6A 2 30 50kA 10 10kA 30 15 CC 200kA DCA001203 12A, 5mH MRL-00801 8A, 1.5mH MRL-00802 8A, 3mH TH-N12(CX)KPUL6.6A 5.2-8.0A 7.5A 3 30 50kA 25 10kA 30 20 CC 200kA DCA001203 12A, 5mH MRL-01201 12A, 1.25mH MRL-01202 12A, 2.5mH TH-N12(CX)KPUL11A 9.0-13.0A 10.6A 5 30 50kA 25 10kA 30 30 CC 200kA DCA001803 18A, 2.75mH MRL-01801 18A, 0.8mH MRL-01802 18A, 1.5mH TH-N20(CX)KPUL15A 12.0-18.0A 16.7A 7.5 60 50kA 32 10kA 60 40 J 200kA DCA003201 32A, 0.85mH MRL-02501 25A, 0.5mH MRL-02502 25A, 1.2mH TH-N20CXTAKPUL22A 18.0-26.0A 24.2A 10 60 50kA 50 10kA 60 50 J 200kA DCA004002 40A, 0.75mH MRL-03501 35A, 0.4mH MRL-03502 35A, 0.8mH TH-N20CXTAKPUL29A 24.0-34.0A 30.8 15 100 50kA 63 10kA 100 80 J 200kA DCA006201 62A, 0.32mH MRL-04501 45A, 0.3mH MRL-04502 45A, 0.7mH TH-N60KP54A 43-65A 46.2A 20 100 50kA 80 22kA 100 90 J 200kA 80RB001 80A, 0.31mH MRL-05501 55A, 0.25mH MRL-05502 55A, 0.5mH TH-N60KP54A 43-65A 59.4A 25 200 100kA 100 22kA 200 125 J 200kA 110RB001 110A, 0.25mH MRL-08001 80A, 0.2mH MRL-08002 80A, 0.4mH TH-N60TAKP82A 65-100A 74.8A 30 200 100kA 125 22kA 200 150 J 200kA 110RB001 110A, 0.25mH MRL-10001 100A, 0.15mH MRL-10002 100A, 0.3mH TH-N120TAKPUL105A 85-125A 88A 40 200 100kA 150 22kA 200 150 J 200kA DCA012502 125A, 0.22mH MRL-13001 130A, 0.1mH MRL-13002 130A, 0.2mH TH-N120TAKPUL105A 85-125A 114A 1 30 50kA 3 10kA 30 4 CC 200kA DCA001203 12A, 5mH MRL-00201 2A, 12mH MRL-00202 2A, 20mH N12(CX)KPUL2.1A 1.7-2.5A 2.1A 2 30 50kA 5 10kA 30 6 CC 200kA DCA001203 12A, 5mH MRL-00402 4A, 6.5mH MRL-00403 4A, 9mH TH-N12(CX)KPUL3.6A 2.8-4.4A 3.4A 3 30 50kA 8 10kA 30 8 CC 200kA DCA001203 12A, 5mH MRL-00402 4A, 6.5mH MRL-00403 4A, 9mH TH-N12(CX)KPUL5.0A 4.0-6.0A 4.8A 5 30 50kA 13 10kA 30 15 CC 200kA DCA001203 12A, 5mH MRL-00802 8A, 3mH MRL-00803 8A, 5mH TH-N12(CX)KPUL6.6A 5.2-8.0A 7.6A 7.5 30 50kA 16 10kA 30 20 CC 200kA DCA001803 18A, 2.75mH MRL-01202 12A, 2.5mH MRL-01203 12A, 4.2mH TH-N12(CX)KPUL11A 9.0-13.0A 11A 10 30 50kA 25 10kA 30 30 CC 200kA DCA001803 18A, 2.75mH MRL-01802 18A, 1.5mH MRL-01803 18A, 2.5mH TH-N20(CX)KPUL15A 12.0-18.0A 14A 15 30 50kA 40 22kA 30 30 CC 200kA DCA002503 25A, 1.275mH MRL-02502 25A, 1.2mH MRL-02503 25A, 1.8mH TH-N20CXTAKPUL22A 18.0-26.0A 21A 20 60 50kA 40 22kA 60 40 J 200kA DCA003202 32A, 1.62mH MRL-03502 35A, 0.8mH MRL-03503 35A, 1.2mH TH-N20CXTAKPUL29A 24.0-34.0A 27A 25 60 50kA 50 22kA 60 50 J 200kA DCA004003 40A, 1mH MRL-03502 35A, 0.8mH MRL-03503 35A, 1.2mH TH-N60KP35A 30-40A 34A 30 60 50kA 80 22kA 60 60 J 200kA 50RB002 50A, 0.97mH MRL-04502 45A, 0.7mH MRL-04503 45A, 1.2mH TH-N60KP42A 34-50A 40A 40 100 50kA 80 22kA 100 80 J 200kA 62RB004 62A, 1.2mH MRL-05502 55A, 0.5mH MRL-05503 55A, 0.85mH TH-N60KP54A 43-65A 52A 50 125 50kA 125 22kA 200 110 J 200kA DCA008005 80A, 1.25mH MRL-08002 80A, 0.4mH MRL08003 80A, 0.7mH TH-N60TAKPUL67A 54-80A 65A 60 125 50kA 125 22kA 200 110 J 200kA DCA009202 92A, 0.6mH MRL-08002 80A, 0.4mH MRL08003 80A, 0.7mH TH-N60TAKPUL82A 65-100A 77A 75 125 50kA 125 22kA 200 150 J 200kA 125RB003 125A, 0.5mH MRL-10002 100A, 0.3mH MRL10003 100A, 0.45mH TH-N120TAKPUL105A 85-125A 96A www.meau.com 8/8 F72-091-SLSMKTG-001-A