TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Similar documents
TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-RHH/RHW-2 USE-2 Copper

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

MC, THHN/THWN-2 Copper

MC or MV-105 Copper, TR-XLPE Insulated

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper


Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

UNSHIELDED MULTI CONDUCTOR

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

IEEE 1580 TYPE T/N CABLE

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

Omni Cable is a master distributor of specialty wire and cable selling

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

MEDIUM VOLTAGE

C-L-X Aluminum Sheath Type IEC

TUNNELING POWER CABLES

Okoguard -Okoseal Type IEC

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

High Voltage Copper, Smooth Aluminum Shield/Sheath

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

EcoSystem Cable Low-Voltage Cables. Features Internal conductors match EcoSystem device terminal and lead color scheme.

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

Section 8. Portable Cordage & Power Cable

Wired for Power Generation

Type MMV-WP Medium Voltage Wind Power Cable

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

Technical Data Sheet Unshielded (YY) PVC Control Cable

Type P Drilmar 125-XE Signal & Instrumentation

INDUSTRIAL

Easier! Faster! Safer!

Type P Drilmar 125-XE Signal & Instrumentation

Medium Voltage Power Cables

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

Technical Data Sheet Shielded (CY) PVC Control Cable

E R C. R E R C ; ; W T E C

Technical Data Sheet Unshielded (YY) PVC Control Cable

ELECTRICAL MATERIALS. Hot-dip galvanize the inside and outside surfaces of rigid steel conduit and fittings.

Automotive Cables. The Global Cable Solutions Company

75 OHM COAXIAL CABLE (RG6)

HW250 REV 8/16 TYPE SOOW. 600 Volt UL/CSA, -40 C to 90 C Black Jacket Flexible Copper Conductors

KALAS ENTERTAINMENT CABLE

Variable Frequency Drive (VFD) Cable Solutions

Technical Data Sheet Shielded (CY) PVC Control Cable

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

Power & Control Cables

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

CABLED TWISTED PAIRS CONDUCTORS

CABLED SINGLE CONDUCTORS

Power & Control Cable IEC

Technical Data Sheet Shielded (CY) PVC Control Cable

Agency Approvals UL and CSA China RoHS - Below MCV Yes Color Red EU RoHS Compliant Yes Maximum Recommended Voltage Rating 600 Volt Units per Box 100

Printer-friendly format 3M Scotchlok Electrical Spring Connectors Y- BOX 5-8#22, 4-6#20, 2-5#18, 2-3#16 AWG, 100 per box, Yellow. Learn More...

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET

Marine Wire and Cable

Detailed Specifications & Technical Data

STABILOY BRAND FeeDeR SOLuTIONS

Detailed Specifications & Technical Data

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

LUTZE Flexible Cable and Wire Management for Industrial Automation. USA Cable Solutions

Power & Control Cable IEC

Category # 1 - Overhead, Primary, & Secondary Conductors

Primary, Secondary, Post-Secondary Education Facilities

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

Medium Voltage Cables for PermaLife Nuclear Utility Applications

Detailed Specifications & Technical Data

Product Descriptions

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

Airfield Ground Lighting

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

NEC 2014 Code Changes

VFD CABLES FOR MOTOR AND DRIVE APPLICATIONS

Power & Control Cables. U o. /U 0.6/1 kv - IEC

ATHLETIC STADIUMS AND SPORTS ARENAS

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

TECHNICAL GUIDELINE. Medium Voltage Conductor Ampacities ALUMINUM COPPER. Single Conductor 5kV - 35kV

PVC motor cables unshielded

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Transcription:

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated PVC Jacketed; ER; FT4; RoHS; 600 V Features Standards Complete cable is RoHS compliance. UL Listed as TC ER sizes 14 AWG 5 AWG. The complete cable (18 AWG and up) is UL listed as FT4 rated and meets the following 70,000 Btu/h Vertical Tray Flame Tests: IEEE 383 ICEA T-30-520 IEEE 1202/FT4 Single conductors are dual rated THHN/THWN-2. Application These cables are specifically approved for power, control, lighting and signal circuits, in manufacturing, industrial and commercial installations. For use in accordance with NEC, Article 336, in cable trays, in raceways, or where supported in outdoor locations by a messenger wire. In cable tray in hazardous (classified) locations Class I, Division 2 per NEC, also as Class I circuits per Article 725. UL 1277 Electrical Power and Control Tray Cables with Optional Optical-Fiber Members. UL 83 Thermoplastic-Insulated Wires and Cables. ICE A S-73-5 32 NEMA WC57 Standard for Control Cables. ICE A S-95-658 Standard for Non-shielded Power Cables Rated 2000 Volts or Less. Specifications Maximum operating voltage: 600 volts Maximum conductor operation temperatures: 90 C wet and dry Engineering Information 1. Conductor: Soft annealed uncoated copper compressed Class B or C stranding or unilaycompressed (19 wires) per ASTM B8, or combination unilay per ASTM B787. Sizes: 14 AWG up to 1000 kcmil. 1 2 2. Insulation: RoHS and flame retardant thermoplastic polyvinyl chloride (PVC) and nylon covering. Conductor Identification ICEA: 14 AWG 10 AWG: Color coded per Method 1 Table E-2, without White and Green colors. On request, Table E-1, which includes White and Green colors. Sizes 8 AWG 1000 kcmil: Black insulation with Printed numbers, 1, 2, 3, or 4. On request, Color coded, BL, WH and Red or Green. 3. Grounding (Optional): One bare or one or more insulated conductors. 4. Assembly: Phase and optional grounding conductor(s) cabled with non hygroscopic fillers, as required and binder tape. C o n t r o l C a b l e P o w e r C a b l e 3 4 5 5. Jacket: Black RoHS, sunlight resistant and flame retardant polyvinyl chloride (PVC) compound. Tray Cables

Technical Data Size Strands Insulation: PVC/Nylon Nominal Insulated OD 18 AWG 16 15/5 mil 77 mil 2 Flat 45 0.18 x 0.27 33 3 45 0.29 46 4 45 0.31 55 5 45 0.33 67 6 45 0.36 79 7 45 0.36 83 8 45 0.41 105 9 45 0.45 110 10 45 0.45 114 12 45 0.46 130 15 45 0.51 163 16 45 0.51 167 18 60 0.56 203 19 60 0.56 207 20 60 0.59 224 24 60 0.64 269 42 60 0.79 419 Size Strands Insulation: PVC/Nylon Nominal Insulated OD 16 AWG 19 15/5 mil 88 mil 2 Flat 45 0.19 x 0.29 45 3 45 0.31 59 4 45 0.34 72 5 45 0.36 88 6 45 0.39 105 7 45 0.39 111 8 45 0.45 140 9 45 0.49 147 10 45 0.49 153 12 45 0.51 177 14 60 0.56 218 15 60 0.59 240 16 60 0.59 246 18 60 0.62 275 19 60 0.62 281 20 60 0.65 304 24 60 0.71 366 26 60 0.74 378 30 60 0.76 420 33 60 0.79 459 37 60 0.82 505

Size Strands Insulation: PVC/Nylon Nominal Insulated OD 14 AWG 19 15/5 mil 102 mil 2 Flat 45 0.21 x 0.32 57 3 45 0.34 77 4 45 0.37 96 5 45 0.40 119 6 45 0.43 142 7 45 0.43 152 8 45 0.50 191 9 60 0.58 219 10 60 0.58 229 12 60 0.59 264 14 60 0.62 301 15 60 0.66 331 16 60 0.66 340 18 60 0.69 381 19 60 0.69 391 20 60 0.72 422 24 60 0.79 509 26 60 0.82 528 30 80 0.89 627 33 80 0.92 684 37 80 0.95 752

Size Strands Insulation: PVC/Nylon Nominal Insulated OD 12 AWG 19 15/5 mil 120 mil 2 Flat 45 0.22 x 0.35 78 2 45 0.36 87 3 45 0.38 112 4 45 0.41 134 5 45 0.45 167 6 45 0.49 199 7 45 0.49 216 8 60 0.60 288 9 60 0.65 306 10 60 0.65 322 12 60 0.67 374 14 60 0.70 428 15 60 0.74 470 16 60 0.74 486 18 60 0.78 545 19 60 0.78 561 20 60 0.82 605 24 80 0.94 769 26 80 0.97 801 30 80 1.00 896 33 80 1.04 981 37 80 1.08 1082

Size Strands Insulation: PVC/Nylon Nominal Insulated OD 10 AWG 19 20/5 mil 154 mil 2 Flat 45 0.26 x 0.42 113 2 45 0.43 128 3 45 0.45 167 4 45 0.49 212 5 60 0.57 270 6 60 0.62 321 7 60 0.62 346 8 60 0.72 434 9 60 0.79 460 10 60 0.79 485 12 60 0.81 567 14 80 0.90 689 15 80 0.94 755 16 80 0.94 780 18 80 0.99 874 19 80 0.99 900 20 80 1.04 971 24 80 1.14 1173 26 80 1.18 1221 30 80 1.22 1374 33 80 1.27 1504 37 80 1.32 1663 Size AWG or kcmil Two Number of Strands Insulation PVC/Nylon * At the option of manufacturer, Ground Conductor can be divided in three, one in each interstice. Optional Grounding* Conductor Jacket Approximate Outside Diameter Approximate Net Weight W/O Ground Ground mil AWG lb/kft 8 7 30/6 10 60 0.56 214 251 6 19 30/6 8 60 0.63 299 355 4 19 40/7 8 60 0.77 453 518 2 19 40/7 6 80 0.93 692 791 1 19 50/8 6 80 1.05 867 977 1/0 19 50/8 6 80 1.13 1045 1164 2/0 19 50/8 6 80 1.22 1265 1395 3/0 19 50/8 4 80 1.32 1539 1720 4/0 19 50/8 4 80 1.46 1900 2102 250 37 60/9 4 80 1.57 2214 2432 300 37 60/9 3 110 1.74 2701 2964 350 37 60/9 3 110 1.84 3089 3369 500 37 60/9 2 110 2.09 4232 4599 600 61 80/10 2 110 2.33 5108 5529 750 61 80/10 1 110 2.54 6235 6751

Size AWG or kcmil Three Number of Strands Insulation PVC/Nylon Optional Grounding* Conductor Jacket Approximate Outside Diameter Approximate Net Weight W/O Ground Ground mil AWG lb/kft 8 7 30/6 10 60 0.59 279 311 6 19 30/6 8 60 0.67 396 448 4 19 40/7 8 60 0.82 606 660 2 19 40/7 6 80 0.99 929 1011 1 19 50/8 6 80 1.12 1168 1257 1/0 19 50/8 6 80 1.21 1418 1512 2/0 19 50/8 6 80 1.30 1728 1827 3/0 19 50/8 4 80 1.41 2115 2259 4/0 19 50/8 4 80 1.56 2618 2773 250 37 60/9 4 110 1.74 3164 3328 300 37 60/9 3 110 1.85 3712 3912 350 37 60/9 3 110 1.96 4260 4469 500 37 60/9 2 110 2.24 5878 6149 600 61 80/10 2 110 2.50 7093 7393 750 61 80/10 1 110 2.72 8692 9062 Four 8 7 30/6 10 60 0.65 354 387 6 19 30/6 8 60 0.74 508 560 4 19 40/7 8 80 0.95 821 873 2 19 40/7 6 80 1.09 1199 1281 1 19 50/8 6 80 1.23 1508 1590 1/0 19 50/8 6 80 1.33 1836 1922 2/0 19 50/8 6 80 1.44 2243 2334 3/0 19 50/8 4 80 1.56 2752 2886 4/0 19 50/8 4 110 1.79 3521 3663 250 37 60/9 4 110 1.92 4109 4257 300 37 60/9 3 110 2.05 4829 5012 350 37 60/9 3 110 2.17 5551 5740 500 37 60/9 2 110 2.48 7683 7927 600 61 80/10 2 140 2.83 9449 9714 750 61 80/10 1 140 3.08 11573 11901 * At the option of manufacturer, Ground Conductor can be divided in three, one in each interstice.