General Design Features

Similar documents
EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

Installation Instructions For EZ-View Flow Meter and EZ-View Flow-Alert Flow Meter FORM # HLIT 300 I. INTRODUCTION II. OPERATING PRINCIPLE

EZ-View. Flow Meters ISO CERTIFIED 9001

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

CAUTION CAUTION IN-LINE LIQUID FLOW METER INSTALLATION & MAINTENANCE INSTRUCTIONS FORM # HLIT205-2G

Flow-Alert Flow Switch Installation & Maintenance Instructions

In-line Pneumatic Flow Meter Installation & Maintenance Instructions

MODEL 200 MULTI-JET FLOW METER

MODEL 200 MULTI-JET FLOW METER

MODEL 900 IMPELLER-TYPE FLOW METER

Model 1100 Turbine Flow Meter

MODEL 1100 TURBINE FLOW METER

Model 1100 Turbine Flow Meter Repair Kits

Flow-Alert Flow Switches (Micro Switch)

KOBOLD DF-MA Flow Transmitter. User Instructions

Variable Area Flow Meters Improve productivity and reduce maintenance costs through reliable flow metering and process control technology.

KOBOLD DF-WM Flow Monitor. User Instructions

Model 1100 Turbine Flow Meter

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

KOBOLD KSK FLOWMETER. User Instructions

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

EZ-IN Series Turbine Flowmeter

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

Liquid Turbine Flowmeter

Variable Area Flow Meters. Inline Pneumatic Flow Meter. User Manual. VAM-UM EN-02 (August 2014)

M-50/55 Series. Fixed setting flow switch with in-line flow

DIGIFLO ELECTRONIC FLOWMETER

COMPANY. Flow Rate Alarms Installation, Operating & Maintenance Manual

Installation, Operation & Maintenance Manual

7430 Series Hastelloy / Monel / Stainless Steel Installation Instructions

ELECTRONIC CONTROLLER

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

MODEL B1750 POSITIVE DISPLACEMENT FLOW METER

TBM Series 3-Way Ball Valve

ZDM Positive Displacement Flow Meter User Instructions

Variable Area Flow Meters and Flow Switches. Easy-to-Use and Reliable Flow Measurement.

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

COMPANY. Liquid Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:FLOWLIQUIDMETERMAN082516

Flow Meters. Installation, Operation & Maintenance Manual.

Flow-Alert Flow Switch

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

100 Series Flow Switches

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Tracer VM with User Interface

THE INSIDE STORY OF THE QPV OR MPV:

100 Series Flow Switches Technical Reference Manual

Manifold w/ Needle Valve Instruction Manual

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Tracer VMA with AutoReg

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Motorized Stainless 2-Way Valves

MODEL G300 BRAKE BLEEDER

M-200 Series. High flow, Adjustable flow switch with right-angle flow

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

MS Application. Features. Proportional Valve Actuator General Instructions

Signet 2517 Brass Paddlewheel Flow Sensor * *

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Flow-Alert. Flow Switch GPM LPM OIL FLOW-ALERT FLOW SWITCH 6000 PSI / 414 BARS MAX. User Manual. VAM-UM EN-02 (September 2014)

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

Gauge Adapter Instruction Manual

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

10 S e r i e s PRESSURE SWITCH. features

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

Mid-West. Instrument ELECTRICAL DIVISION 1 LOCATIONS:

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

TOTALIZER-TRANSMITTER

± ± ± ± ± ± ± ± 85.

INSTALLATION AND OPERATION MANUAL

Analog Hydraulic Testers

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

700 Series FluidVision

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

BULLETIN NO.ELEC IM240/11A Supersedes IM240/10A

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

500 SERIES METERING FLOW SWITCHES TECHNICAL REFERENCE MANUAL. Proteus Industries Inc. Proteus 5-Year Warranty

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

Installation and Operating Manual

MODEL Q-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

Air Control Kits INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

CORROSION RESISTANT IN LINE FLOW SWITCHES

Installation Instructions F-440N. Model No. F F F F F F F /16 157mm. Inline.

INSTALLATION INSTRUCTIONS SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

Installation, Operation and Maintenance Manual

MODEL 5120 Tire Repair Station

B21 Series BASOTROL Gas Valve

P70, P72, and P170 Controls for Low Pressure Applications

Transcription:

General Design Features OPERATING PRINCIPLE The Hedland flow meter is a variable area instrument. A precision machined, sharp-edged Orifice ➀ located within the Piston Assembly ➁, forms an annular opening with the contoured Metering Cone ➂. The Piston Assembly carries a cylindrical PPS/Ceramic Magnet ➃ that is magnetically coupled to an external Flow Indicator ➄ that moves precisely, in direct response to movement of the Piston. A calibrated Spring ➅ opposes flow in the forward direction. This spring decreases viscosity sensitivity and allows the flow meter to be used in any position, including inverted. Bi-directional flow capability: If required, a reverse flow by-pass option is available and is depicted on individual product pages. Note that flow is measured in the forward direction only. Operates in any position: The Hedland in-line flow meter s unique spring-loaded variable area design allows meters to be installed in any position without affecting accuracy. An optional inverted flow scale is also available. Easier to read linear scale: This flow meter is the most readable product in its class. Brightly colored indicators move over the graduated, linear Flow Scale ➆ which contains bold, easy-to-read numerals and gauge marks. This enhanced resolution virtually eliminates parallax problems associated with competitive, direct reading flow meters. RELIABLE FLOW MEASUREMENT 360 Rotatable guard/scale: Hedland s unique design allows the meter to be installed in any orientation without regard to scale direction. Once the meter is permanently installed, the guard/scale can be rotated 360 to optimize readability. Rugged construction: Flow meters are available in anodized aluminum, brass, T303 and T316 stainless steel, with SAE, NPTF, BSPP, and Code 61 and Code 62 4-bolt flanged ports. This easyto-read flow meter is a reliable and trouble-free flow rate indicator, monitoring a variety of liquids and gases (including aggressive chemicals), under a wide range of pressures, temperatures and rigorous conditions encountered in industrial applications. No flow straighteners or special piping: The Hedland design does not require special plumbing or accessories to stabilize turbulent flow. Flow meters can be installed immediately adjacent to 90-degree elbows or other components to provide greatest system design flexibility, while saving installation time and money. Relatively insensitive to shock and vibration: This unique design is inherently less sensitive to shock and vibration than other variable area flow meters. The new, improved coupling forces between the internal and external magnets greatly reduce the chance of decoupling the flow indicator under high flow and pressure transients. The magnetic coupling also eliminates the need for mechanical linkages that wear, loosen and leak over the functional life of competitive meters. FAX 800-245-3569 2

EZ-View Flow Meters For Oil, Water, Air & Compressed Gases 1/2 to 1 inch ports EZ to install, in any position No special piping or flow SPECIFICATIONS: MATERIALS: Polysulfone plastic body, piston and cone T300-series stainless spring Buna N flow indicator ring and pressure seals C360 Brass, PVC, or T303 stainless fittings Polypropylene limit indicators PH15 7MO stainless retaining ring Optional: Teflon coated spring and retaining ring, consult factory. FITTINGS/ THREADS: NPT ANSI/ASME B1.20.1, BSPT ISOR7 See Ordering Information Table, page 64 TEMPERATURE RANGE: 32 F to 250 F (0 C to 121 C) 1 PRESSURE RATING: Liquid: 325 psi / 22.4 bar maximum 1 PRESSURE DROP: See Differential Pressure Charts, page 64 ACCURACY: ±5% of full scale REPEATABILITY: ±1% DIMENSIONS: See Ordering Information Table, page 64 straighteners needed No electrical connections Direct reading indication Accuracy within ±5% full scale Relatively insensitive to shock and vibration 1 1 Meters with Type 1 PVC fittings: Pressure rating per normal PVC system specifications Temperature range - 32 F to 140 F (0 C to 60 C) Teflon is a registered trademark of E.I. dupont de Nemours & Co. 63 TEL. 800-433-5263 GOOD VISCOSITY STABILITY 1

PRESSURE DROP (PSID) 8.00 6.00 4.00 2.00 10 GPM 4 GPM EZ-View Flow Meters For Oil, Water, Air & Compressed Gases OIL & WATER METERS 7GPM 16 GPM 18 GPM 0.0 0.0 3 6 9 12 15 18 21 24 27 30 FLOW (GPM) AIR METERS 28 GPM Ordering Information PRESSURE DROP (PSID) 8.00 6.00 4.00 2.00 150 SCFM 100 SCFM 70 SCFM 170 SCFM 0.0 0.0 25 50 75 100 125 150 175 200 225 250 45 SCFM FLOW (SCFM) 250 SCFM 1/2" NPTF 1/2" NPTF 1/2" BSPT 3/4" NPTF 3/4" BSPT 3/4 or 1 inch 1" NPTF 1" nominal 1" NPTF Fluid Flow Range female, female, female, male, male, nominal, male, socket weld male, Media swivel swivel swivel swivel swivel swivel sweat plastic PVC swivel brass fitting T303 SS fitting brass fitting brass fitting brass fitting brass fitting polysulfone fitting PVC fitting fitting 0.5 4 GPM 2 15 LPM H624-104 H626-104 H627-104 H625-104 H630-104 H621-104 H628-104 H629-104 1.0 7 GPM 4 26 LPM H624-107 H626-107 H627-107 H625-107 H630-107 H621-107 H628-107 H629-107 Oil 1.0 10 GPM 4 35 LPM H624-110 H626-110 H627-110 H625-110 H630-110 H621-110 H628-110 H629-110 0.876 s.g. 1.0 16 GPM 5 60 LPM H624-116 H626-116 H627-116 H625-116 H630-116 H621-116 H628-116 H629-116 3.0 18 GPM 15 65 LPM H625-118 H630-118 H621-118 H628-118 H629-118 4.0 28 GPM 20 100 LPM H625-128 H630-128 H621-128 H628-128 H629-128 0.5 4 GPM 2 15 LPM H624-004 H626-004 H627-004 H625-004 H630-004 H620-004 H621-004 H628-004 H629-004 1.0 7 GPM 4 26 LPM H624-007 H626-007 H627-007 H625-007 H630-007 H620-007 H621-007 H628-007 H629-007 Water 1.0 10 GPM 4 35 LPM H624-010 H626-010 H627-010 H625-010 H630-010 H620-010 H621-010 H628-010 H629-010 1.0 s.g. 1.0 16 GPM 5 60 LPM H624-016 H626-016 H627-016 H625-016 H630-016 H620-016 H621-016 H628-016 H629-016 3.0 18 GPM 15 65 LPM H625-018 H630-018 H620-018 H621-018 H628-018 H629-018 4.0 28 GPM 20 100 LPM H625-028 H630-028 H620-028 H621-028 H628-028 H629-028 10 45 SCFM 5 20 LPS H624-204 H626-204 H627-204 H625-204 H630-204 H621-204 H629-204 20 70 SCFM 10 30 LPS H624-207 H626-207 H627-207 H625-207 H630-207 H621-207 H629-207 Air 25 100 SCFM 15-45 LPS H624-210 H626-210 H627-210 H625-210 H630-210 H621-210 H629-210 1.0 s.g 30 150 SCFM 20 70 LPS H624-216 H626-216 H627-216 DISCONTINUED H625-216 H630-216 H621-216 H629-216 55 170 SCFM 30 80 LPS H625-218 H630-218 H621-218 H629-218 75 250 SCFM 35 110 LPS H625-228 H630-228 H621-228 H629-228 DIMENSIONS: Length in (mm) 7.75 (196.8) 7.75 (196.8) 7.75 (196.8) 8.25 (209.5) 8.25 (209.5) 7.75 (196.8) 5.25 (133.3) 8.46 (214.9) 8.86 (225.0) Fitting Flats in (mm) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) 1.50 (38.1) 1.50 (3.81) 1.50 (38.1) N/A 1.54 (39.1) 1.50 (38.1) Weight lb (kg) 0.95 (0.43) 0.85 (0.39) 0.95 (0.43) 0.90 (0.41) 0.90 (0.41) 0.75 (0.34) 0.20 (0.09) 0.35 (0.16) 0.55 (0.25) Fits 3/4" copper tube types K, L, M; 1" copper tube type M only. DO NOT use pipe dope. Use Teflon tape only. Use with plastic pipe fittings only. Fits 1" Sch 40/80 PVC, CPVC pipe. Requires 1" pipe coupling. Length includes end fittings. ACCURATE OVER A WIDE VISCOSITY RANGE FAX 800-245-3569 64

Installation Instructions For EZ-View Flow Meter and EZ-View Flow-Alert Flow Meter DIVISION OF RACINE FEDERATED INC. FORM # HLIT 300 8635 Washington Avenue Racine Wisconsin 53406-3738 USA TEL 800-HEDLAND FAX 800-CHK-FLOW CAUTION This product should be installed and serviced by technically qualified personnel trained in maintaining industrial class flow instrumentation and processing equipment. CAUTION Read instructions thoroughly before installing the unit. If you have any questions regarding product installation or maintenance, call your local supplier for more information. I. INTRODUCTION The EZ-View series flow meter is a rugged, low-cost direct reading industrial class flow meter that is simple to install. It can be mounted (installed) in any position from vertical to horizontal without costly flow straighteners or other special plumbing. Constructed of high impact polysulfone plastic, the EZ-View product line offers excellent structural integrity and chemical compatibility with a wide range of industrial chemicals. EZ-View flow meters provide instantaneous, directreading flow rate measurement of liquids in closed piping systems. The transparent polysulfone plastic body allows visual inspection of the fluid condition as well as viewing of the internal flow indicator relative to a calibrated flow scale. See Figure 1. EZ-View meters do not require electrical connections for operation, and provide measurement by creating a predictable differential pressure across a sharp-edged orifice that is located in the piston assembly. II. OPERATING PRINCIPLE The EZ-View series flow meter is a piston-type variable area flow meter that uses a sharp-edged annular orifice, formed between an open-centered piston and a tapered metering cone. The piston is held in a no-flow position at the base of the cone by a precision retention spring. As flow in the pipe increases, the differential pressure correspondingly increases across the piston orifice, and moves the piston/flow indicator against the spring. The greater the flow rate, the further the piston moves along the tapered metering cone. The flow rate is measured by viewing the red indicator ring, mounted on the piston, relative to a graduated flow scale located on the transparent flow meter body (see Figure 2). Figure 1. EZ-View Flow Meter Figure 2. Flow Rate Indicator The unique design allows the EZ-View meter to be mounted in any orientation horizontal, vertical, upside down, etc. without sacrificing measurement performance. Flow straighteners, located in the inlet and outlet, allow the flow meter to be less sensitive to turbulent flow conditions. Liquid measurements are provided in GPM (Gallons per Minute) and LPM (Liters per Minute). Page 1

III. SPECIFICATIONS Accuracy ± 5% of full scale Repeatability ± 1% Pressure Rating 325 PSI (22.4 bar) Maximum Meters with Type 1 PVC fittings subject to normal PVC system ratings Temperature Range 32 F to 250 F (0 C to 121 C) 32 F to 140 F (0 C to 60 C) for meters with Type 1 PVC fittings Pressure Drop See Pressure Drop Charts on page 13. Fittings/Threads NPT ANSI/ASME B1.20.1 BSPT ISOR7 BSPP ISO228 Materials (wetted): Body Polysulfone Dimensions Piston Polysulfone Cone Polysulfone Spring T300 Stainless Steel Retaining Rings PH15-7MO Stainless Steel Seals Buna-N Indicator Ring Buna-N Limit Indicators Polypropylene Magnet Strontium Ferrite (switching units only) Fittings C360 Brass PVC T303 Stainless Steel Materials (non-wetted) Limit Indicator Polypropylene Scale Polyester Material Compatibility See Fluid Selection Chart on page 12. Calibration Fluid Oil 0.871 specific gravity 32 cst viscosity Water 1.0 specific gravity 1.0 cst viscosity 3.25 (82.5) BODY FLATS LENGTH 3.50 (88.9) DIA 40 LPM 100 200 300 325 psi @ 70 F MAX 22.4 bar @ 21 C MAX 380 1/2", 3/4" & 1" Sizes Size Material Connection Length Fitting Flats & Type in. (mm) in. (mm) 1/2" NPTF Brass Female 7.75 1.50 & BSPT & SS (196.8) (38.1) 3/4" NPTF Brass Male 8.25 1.50 & BSPT (209.5) (38.1) 3/4" & Brass Male 7.75 1.50 1" Sweat Brass Sweat (196.8) (38.1) 1" NPTF Polysulfone Male 5.25 N/A (133.3) 1" Nominal PVC Socket 8.46 1.54 Weld (214.9) (39.1) 1" NPTF PVC Male 8.86 1.50 (225.0) (38.1) 1-1/2" & 2" Sizes Size Material Connection Length Fitting Flats & Type in. (mm) in. (mm) 1 1 /2" NPTF Brass Female 8.72 3.00 & BSPP (221.5) (76.2) 2" NPTF Brass Female 8.72 3.00 & BSPP (221.5) (76.2) 2" Socket PVC Socket 11.48 N/A Weld Weld (291.6) -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- Page 2

IV. INSTALLATION CAUTION This unit should be installed and serviced by technically qualified personnel trained in maintaining industrial class flow instrumentation and processing equipment. 24 20 16 8 12 4 Flow Direction Indicator 90 80 60 40 20 GPM LPM WATER Installation Recommendations The flow meter is a simple device to install. However, the following measures are recommended for reliable, trouble-free operation: Don't - Allow liquid pipe sealant to come into contact with the plastic flow meter. Most pipe sealants contain solvents that are not compatible with polysulfone plastic and will result in the flow meter body weakening and potentially fracturing under pressure. If a pipe sealant is required, use of Teflon tape is recommended. Don't - Install the flow meter in piping systems that are not aligned or properly supported. Don't - Connect the flow meter male plastic NPT fittings to female metal NPT couplings. Differences in coefficients of expansion between metals and plastics can cause the plastic flow meter body to crack. Utilize a female-to-female plastic pipe coupling to connect metal pipe to the plastic flow meter. Don't - Use pipe wrenches on the flow meter body. To avoid scarring or otherwise damaging the external surface, use an open-end wrench on the integral hex flats during installation. Don't - Subject the flow meter to back pressure or back flow. The flow meter will operate as a leaky check valve when subjected to reverse flow, but can be damaged if the reverse hydraulic horsepower is too great. Don't - Install the flow meter on systems with large degrees of particulate contamination. Minimum filtration of 200 mesh (74 micron) is recommended for trouble-free operation. Don't - Install O-ring seals that have not been lubricated. Figure 3. Flow Direction Indicator Piping (Plumbing) CAUTION To avoid unnecessary pipe flexing that could cause structural stress on the flow meter body, independent support located as near as possible to the inlet and outlet of the meter should be used to isolate the meter from the piping system. Failure to provide this support could reduce the life of the meter. 1. Piping should be properly aligned with the meter inlet and outlet to minimize structural stress on the plastic meter body. Special attention should be given to this effort if higher operational pressures and/or temperatures are anticipated. Piping should be firmly supported by external mounting brackets, both upstream and downstream from the meter to avoid any pipe flexing that could reduce the life of the meter. 2. If the flow meter inlet or outlet are to be rigidly mounted, and the opposing port is to be connected to a flexible hose, the end connected to the flexible hose MUST be rigidly mounted. 3. This unique design does not require special plumbing or accessories to stabilize turbulent flow. Flow meters can be installed immediately adjacent to 90 elbows or other components, providing system design flexibility. 4. A 200 mesh (74 micron) or better filtration is required to assure reliable performance. Flow Direction These meters only accept flow in one direction. Make sure to align the Flow Arrow, located on the bottom of the meter s flow scale, in the same direction as the anticipated line flow. (See Figure 3). Mounting Orientation The meter can be installed to operate in any position. Page 3

H621-XXX 1" NPT Models (See Figure 4) 1. Apply a single layer of Teflon tape to the male NPT threads of the flow meter. 2. Thread the flow meter inlet into a 1" NPT plastic, female pipe coupling. 3. Thread the flow meter and coupling onto the inlet pipe and hand tighten. Make sure the flow direction arrow on the flow meter corresponds with the system flow direction (see Figure 3 on page 3). 4. Place an open-end wrench on the flow meter body hex and place a pipe wrench on the metal mating pipe. Tighten until snug. DO NOT overtighten. Make sure the flow meter scale is oriented for convenient viewing. DO NOT back off/unscrew fittings to rotate scale for better viewing. 5. Thread a 1" NPT plastic pipe coupling to the outlet connection of the flow meter. Stack a pipe nipple and half of a pipe union onto the pipe coupling. Tighten the assembly as required. 6. Install the other half of the pipe union to the outlet pipe and connect the union halves together. 7. Piping should be supported and aligned properly to avoid placing stress on the flow meter body. 8. Slide the limit indicators to point to appropriate positions on the flow meter scale. To remove the limit indicators, slide them fully towards the flow meter outlet. H628-XXX 1" and H619-XXX 2" PVC with Socket Weld Models (See Figure 5) 1. Remove the two end fittings from the flow meter. Lubricate the O-rings and install the fittings onto the flow meter. 2. Prepare the flow meter PVC fittings and PVC pipe couplings with PVC cleaner/solvent. 3. Apply a thing layer of PVC glue to the PVC flow meter fittings. Orient the meter during curing to ensure that excessive glue will not run into the flow meter internal components. Connect all PVC glue joints by inserting the pipes fully into their mating components and twisting 1/8 turn to guarantee adhesion. Allow sufficient drying time. Figure 4. Model H621-XXX 1" NPT Models Installation 4. Using the method outlined in steps 2 & 3, apply 1/2 of the PVC union to the flow meter outlet fitting. 5. Install the other 1/2 PVC pipe union to the outlet pipe. 6. Make sure the flow direction arrow on the flow meter corresponds with the system flow direction (see Figure 3 on page 3). Lubricate the union O-ring and connect the union together. 7. Piping should be supported and aligned properly to avoid placing stress on the flow meter body. 8. Slide the limit indicators to point to appropriate positions on the flow meter scale. To remove the limit indicators, slide them fully towards the flow meter outlet. Note: To replace meter body order P.N. H622-XXX Pipe Support 1" Coupling 1" Union PVC Pipe Figure 5. Model H628-XXX 1" & H619-XXX 2" PVC Socket Weld Models Installation Page 4

H620-XXX Brass Sweat Fitting Models (See Figure 6) 1. Remove both brass fittings from the flow meter inlet and outlet. Remove O-rings from the fittings. 2. Apply solder flux to the flow meter brass fittings and mating pipe surfaces. 3. Place the brass hex coupler onto the pipe with the threads facing the flow meter. Slide the brass sweat fitting onto the prepared pipe. 4. Sweat the fitting onto the pipe. DO NOT apply heat to the brass flow meter fitting with the plastic flow meter body or seals attached to the fitting. 5. Repeat steps 3 & 4 for the other flow meter fitting. Allow fittings to cool. 6. Lubricate the two O-rings removed in step 1. Place the O-rings onto the brass fittings. 7. Place the flow meter in between the two installed brass fittings. Make sure the flow direction arrow on the flow meter corresponds with the system flow direction (see Figure 3 on page 3). Thread the two brass hex couplers into the flow meter body. 8. Rotate the flow meter body so the scale can be conveniently viewed. Tighten the hex couplers. Typically, only hand tightening is required. 9. Piping should be supported and aligned properly to avoid placing stress on the flow meter body. 8. Slide the limit indicators to point to appropriate positions on the flow meter scale. To remove the limit indicators, slide them fully towards the flow meter outlet. Note: To replace meter body order P.N. H622-XXX Figure 6. Model H620-XXX Brass Sweat Fitting Models Installation All Models with Male, Metal or PVC, Threaded, End Fittings (See Figure 7 on page 6) 1. Remove both fittings from the flow meter inlet and outlet. Remove O-rings from the fittings. 2. Apply Teflon tape to the male pipe thread connections. 3. Place the brass or stainless steel hex coupler onto the pipe with the threads facing the flow meter. 4. Thread the flow meter fittings onto the mating pipe. 5. Tighten fittings by placing an open-end wrench onto the fitting and a pipe wrench onto the mating pipe. 6. Repeat steps 3-5 for the other flow meter fitting. 7. Lubricate the two O-rings removed in step 1. Place the O-rings onto the threaded fittings. 8. Place the flow meter between the two installed fittings. Make sure the flow direction arrow on the flow meter corresponds with the system flow direction (see Figure 3 on page 3). Thread the two hex couplers onto the flow meter body. 9. Rotate the flow meter body such that the scale can be conveniently viewed. Tighten hex couplers. Typically, only hand tightening is required. 10. Piping should be supported and aligned properly to avoid placing stress on the flow meter body. 11. Slide the limit indicators to point to appropriate positions on the flow meter scale. To remove the limit indicators, slide them fully towards the flow meter outlet. Note: To replace meter body order P.N. H622-XXX Page 5

Pipe Support Figure 7. All Models w/male, Metal, Threaded, End Fittings Installation All Models with Female, Metal, Threaded, End Fittings (See Figure 8) 1. Apply Teflon tape to the male pipe thread connections. 2. Thread the inlet of the flow meter onto the appropriate pipe connection. Make sure the flow direction arrow on the flow meter corresponds with the system flow direction (see Figure 3 on page 3). 3. Tighten flow meter connection by placing an openend wrench on the flow meter metal connection adjacent to the pipe that is being attached. Tighten until snug. Make sure flow meter scale is oriented for convenient viewing. DO NOT overtighten. DO NOT back off/unscrew to rotate scale for better viewing. CAUTION Do not tighten the flow meter by wrenching from the opposite fitting, as the meter body could crack. 4. Install a union fitting at the outlet end of the flow meter. 5. Piping should be supported and aligned properly to avoid placing stress on the flow meter body. 6. Slide the limit indicators to point to appropriate positions on the flow meter scale. To remove the limit indicators, slide them fully towards the flow meter outlet. Note: To replace meter body order P.N. H622-XXX Pipe Support Union Metal Pipe Figure 8. All Models w/female, Metal, Threaded, End Fittings Installation V. FLOW-ALERT SWITCH OPTIONS NOTE: All Flow-Alert switches are magnetically triggered. It is not possible to add a switch to the basic meter if it was not originally ordered with the switching magnet. Flow-Alert Latching Limit Switch The AC and DC powered Flow-Alert modules consist of a relay circuit housed in a sealed plastic enclosure. The modules have a normally open, dry relay contact that can be used to directly control alarms, warning lights, relays, or interface to a PLC. The relay will be Page 6

Figure 9. Latching Switches latched on as the magnet inside the flow meter passes by the module, and remain latched on until the magnet passes in the other direction, or power is interrupted (see Figure 9). The setpoint is adjustable from 0-100% of full scale. Flow meters can be equipped with one latching limit switch, either AC or DC. Flow-Alert Reed Limit Switch The reed switch Flow-Alert modules are available in three forms: Form A (normally open), Form B (normally closed), and Form C (single-pole, double throw). Figure 10. Reed Switches Reed switches are housed in a sealed plastic enclosure for environmental protection. The reed switch modules do not provide a latching function like the AC and DC powered units. When the magnet inside the flow meter comes within proximity of the module, the reed switch will change state (see Figure 10). The setpoint is adjustable from 0-100% of full scale. Two reed switch Flow Alerts may be installed on a single flow meter but one must be set for activation on increasing flow and the second must be set for activation on decreasing flow. Switch Specifications Specifications AC Latching DC Latching Specifications Reed Switch Reed Switch Reed Switch Form-A (NO) Form-B (NC) Form-C (SPDT) Operating Voltage 115 VAC ± 10% 10-30 VDC N/A N/A N/A Operating Current 25 ma maximum N/A N/A N/A Contact Rating 1A @ 30 VDC Watts Max 15 5 5 0.5A @ 125 VAC Voltage Max 200 175 175 Resistive Load Current Max 1A.25A.25A Operating 32-158 F (0-70 C) 32-250 F (0-121 C) Temperature Cable Not Included 3 ft, 24 AWG 3 ft, 20 AWG 3 ft, 24 AWG N/A 2 Conductor 2 Conductor 3 Conductor PVC Jacket PVC Jacket PVC Jacket Certification NA CE Enclosure Rating NEMA 12 & 13 (IP65) Page 7

! Figure 11. Latching Switch Installation Switches Positioned for Activation on Increasing Flow Flow-Alert Latching Switch Installation, Operation and Adjustment 1. Install one end of the vibration locking kit onto the LPM side of the meters serrated rail as shown in Figure 11. Install the switch by placing the adjustment arms over the serrated rail from the inlet end of the 1/2", 3/4" and 1" meters, or the outlet end of the 1 1 /2" or 2" meters. The direction of the connector and cable assembly indicates whether the switch will activate on increasing flow (connector and cable pointing up), or on decreasing flow (connector and cable pointing down). See Figure 12. Secure the other end of the vibration locking kit and tighten after positioning. 2. The connector has four solder lugs labeled 1, 2, 3 and 4. Soldering wires to the terminals first requires disassembly of the connector as shown in Figure 13. The specific wiring pinouts for each style latching switch are shown in Figure 14. NOTE: Before reassembly, it is recommended to label each wire with the corresponding lug position. 3. After securing wires to solder lugs, determine which direction the body of the connector should face. Before snapping the connector into place, refer to Figure 15. 4. After selecting direction A, B or C, snap connector back together, pull the excess wire out of the strain relief, then tighten the strain relief nut. Plug the connector into the switch module and secure with the screw provided. 90 80 60 40 20 LPM CAUTION 1. Only use Teflon tape to seal threaded fittings. DO NOT use pipe dope. 2. DO NOT sweat fit adaptor fittings into a system while mounted to the EZ-VIEW meter. Body Strain Relief Nut Loosen Strain Relief Nut and Run (4) Wires In Here Gasket Solder Lug Polarity Pin Switch Positioned for Activation on Decreasing Flow Figure 13. Latching Switch Installation Figure 12. Latching Switch Installation Page 8

2 Flow 4 Circuit Fuse 0.1 A DC Switch AC Switch Pin Function Pin Function 1 Relay (NO) 1 Relay (NO) 2 DC+ 2 AC Supply 3 Relay Common 3 Relay Common 4 DC- 4 AC Supply Figure 14. Latching Switch Installation AC Line 1 3 Switch Module Contacts AC Load 2 115 V Relay Coil AC Relay Contact Example shows a secondary (slave) relay with a 115 VAC coil integrated with the AC switch module. This combination allows switching of loads up to the rating of the relay contacts. NOTE: Load limited by relay contacts. Figure 17. AC Conventional Secondary Connections AC Line Flow-Alert Latching Switch AC Wiring Configurations AC Line C B 2 Flow 4 Circuit 1 3 Fuse 0.1 A AC Load 1 Switch Module Contacts NOTE: Load must be within specified contact rating range. 1A @ 30 VDC/500 ma @ 125 VAC. A WARNING Polarity Pin Figure 15. Polarity Pin All wiring should be made in accordance with the National Electrical Code and must conform to any applicable state and local codes. Figure 16. AC Conventional Connection AC Line 10-30 VDC 10-30 VDC 2 Flow 4 Circuit 1 3 Switch Module Contacts Fuse 0.1 A DC Load Figure 18. DC Conventional Connection 2 Flow 4 Circuit 1 3 Switch Module Contacts DC Load 2 Fuse 0.1 A DC Relay Coil DC Relay Contact Example shows a secondary (slave) relay with a DC coil integrated with the DC switch module. This combination allows switching of loads up to the rating of the relay contacts. NOTE: Load limited by relay contacts. Figure 19. DC Conventional Secondary Connection 1 DC Ground DC Ground Page 9

FORM A (Normally Open) RED FORM B (Normally Closed) BLACK BLACK FORM C BLACK (Normally Closed) WHITE WHITE (Common) RED (Normally Open) Figure 20. Form A, B & C Flow-Alert Reed Switch Installation 1. Install the switch on the flow meter by placing the adjustment arm over the serrated rail from the inlet end of the 1/2", 3/4", and 1" meters, or the outlet end of the 1 1 /2" and 2" meters. Each meter will accept up to two reed switches and the switch(es) for 1/2", 3/4" and 1" meters must be installed before the meter is plumbed into the system. 2. Flow-Alert reed switches are available in three configurations: Form A (normally open), Form B (normally closed), and Form C (SPDT). Wire color codes and switch configurations are shown in Figure 20. Flow-Alert Reed Switch Adjustment After the flow meter has been installed and the switch wired, the flow rate at which the switch will activate must be adjusted as follows: 1. With fluid running through the meter, gently move the switch adjustment tab(s) outward until the switch body is free to slide up or down on the serrated rail. See Figure 21. 2. Move the switch into position until the switch activates. See Figure 21. 3. Release the switch adjustment tab(s) to set the switch position. Figure 21. Switch Orientation WARNING FAIL-SAFE OPERATION If the flow meter and switch are to be installed in a critical application, be sure the system is fail-safe. The switch should be wired so any switch failure will stop the system. Failure to fail-safe the system may lead to system damage and/or personal injury. Page 10

VI. MAINTENANCE EZ-View Flow Meters are designed to provide many years of service with little or no maintenance requirements. Periodic cleaning may be required. Clean the outside of the flow meter with denatured alcohol or mild detergent and warm water. Should the inside of the flow meter become stained, it can be disassembled for cleaning. Should the flow meter become jammed with particulate, the meter will require disassembly as described below. The piston assembly should be pushed out from the inlet side to the outlet side. Clean the internal components and reassemble. Disassembly NOTE: Models with a 1" body-it is necessary to remove the spring retaining clip (located at the flow meter outlet port). NOTE: Models with a 2" body can be serviced by removing the two end fittings, then sliding the metering pin out from the inlet, and removing the piston and spring from the outlet. 1. Measure the insertion depth of the retaining ring into the flow meter body with a caliper or other measuring device. 2. Carefully remove the retaining clip with a small, flatblade screwdriver. 3. Remove the spring and piston assembly. 4. Clean the inside of the flow meter body and piston assembly with denatured alcohol or mild detergent and water. 5. Reassemble the meter in reverse order of disassembly. Install the retaining ring to the depth measured in step 1. Use a deep socket of approximately 0.9" diameter and hand pressure to install the retaining ring. For field conversion of the standard scale to other fluids, see Density Effect below. SPECIAL FLOW SCALES Special scales are available for liquids in any measurement unit, and other fluid viscosities and/or specific gravities. VISCOSITY EFFECT (SUS/CST) The design utilizes a sharp-edged orifice and biasing calibration spring that ensures operating stability and accuracy over the wide viscosity range common to many fluids. Generally, high flow models of each meter size provide good accuracy over a viscosity range of 40 to 500 SUS (4.2 to 108 cst). DENSITY EFFECT (SPECIFIC GRAVITY) Any fluid density change from stated standards has a proportional effect on meter accuracy. Special scales can be supplied if actual specific gravity decreases accuracy beyond application limits. Corrections for more or less dense fluids can be made to standard scales using the following correction factor: 1.0 Specific Gravity 0.876 Specific Gravity for water/water-based meters for petroleum-based meters. VII. APPENDIX Fluid Correction STANDARD FLOW SCALES Standard liquid flow scales are calibrated in GPM (Gallons per Minute) and LPM (Liters per Minute) at 0.876 specific gravity for petroleum-based fluids, and 1.0 specific gravity for water and water-based fluids. Page 11

Page 12

Pressure Drop Charts Page 13

NOTES Page 14

NOTES Page 15

LIMITED WARRANTY and DISCLAIMER Hedland, Division of Racine Federated Inc. warrants to the end purchaser, for a period of one year from the date of shipment from the factory, that all flow meters manufactured by it are free from defects in materials and workmanship. This warranty does not cover products that have been damaged due to misapplication, abuse, lack of maintenance, or improper installation. Hedland's obligation under this warranty is limited to the repair or replacement of a defective product, at no charge to the end purchaser, if the product is inspected by Hedland and found to be defective. Repair or replacement is at Hedland's discretion. A returned goods authorization number must be obtained from Hedland before any product may be returned for warranty repair or replacement. The product must be thoroughly cleaned and any process chemicals removed before it will be accepted for return. The purchaser must determine the applicability of the product for its desired use and assumes all risks in connection therewith. Hedland assumes no responsibility or liability for any omissions or errors in connection with the use of its products. Hedland will under no circumstances be liable for any incidental, consequential, contingent or special damages or loss to any person or property arising out of the failure of any product, component or accessory. All expressed or implied warranties, including the implied warranty of merchantability and the implied warranty of fitness for a particular purpose or application are expressly disclaimed and shall not apply to any products sold or services rendered by Hedland. The above warranty supersedes and is in lieu of all other warranties, either expressed or implied and all other obligations or liabilities. No agent or representative has any authority to alter the terms of this warranty in any way. DIVISION OF RACINE FEDERATED INC. Form # HLIT300 2007 02/07 8635 Washington Avenue, Racine, WI 53406-3738 USA Telephone 262.639.6770 or 800.HEDLAND Fax 262.639.2267 or 800.CHK-FLOW www.hedland.com HedlandTechHelp@Racinefed.com Materials & specifications are subject to change without notice. Hedland and EZ-View are registered trademarks of Racine Federated Inc. Flow-Alert is a trademark of Racine Federated Inc. Teflon is a registered trademark of E.I. dupont de Nemours and Company Printed in USA