PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

Similar documents
Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

LIQUID DIELECTRIC TEST SET MODEL NUMBER LD60 VERSION 3.2

VACUUM INTERRUPTER TEST SET

AC DIELECTRIC TEST SET 600P SERIES

Phenix Technologies, Inc. 75 Speicher Drive Accident, Maryland 21520

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

DC DIELECTRIC TEST SET - 400P

DC REGULATED POWER SUPPLY

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

Instruction Manual. Model Y5020. Current Shunt. P/N September 1979

PORTABLE PRODUCTS for Field Testing High Voltage High Current High Power Test Systems and Components

DC REGULATED POWER SUPPLY

Model Volt-Amp-Wattmeter INSTRUCTION MANUAL

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

SURE TRIP SLT-201 SECONDARY TEST SET

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

INSTRUCTION MANUAL Model 1743B

AC DIELECTRIC TEST SET 600P SERIES

Digital-Control and Programmable DC Power Supply Models: , , , & User Manual

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

CN-TOT SERIES Portable Thermocouple Temperature Controller

Hand Held Pull Tester Instruction Manual Order No

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

University of Houston Master Construction Specifications Insert Project Name

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

BROMAN MODEL 123XL PORTABLE LOAD BOX. Series 2

OPERATING INSTRUCTIONS BULLETIN MODEL DA750 March MAGNETIC INSPECTION UNIT

Switching DC Power Supply

HLS Watt Halogen Illuminator Service Manual

DC POWER SUPPLY ALIMENTATION C.C.

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

Force Test Stands Series ES MODELS ESM & ES30. User s Guide

Owner's/Installation Manual

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

CTFRP Series Power Supplies

ALL PURPOSE CNC/HEAVY DUTY

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

XENON POWER SUPPLY 4000 Watt Gladiator IV

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

Advanced Test Equipment Rentals ATEC (2832)

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Mini Multimeter with Non-Contact Voltage Detector (NCV)

B BASIC HEAT TREATMENT CONSOLE

R & D SPECIALTIES ROTROL I USER'S MANUAL

Instruction Bulletin. Jockey Pump Controller

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

Technical Manual. DLM Module. This manual should remain with the unit.

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Accu-Meter Oil Pump. Instruction Manual. Model #2114. Cincinnati, OH USA. Part No Revised June 1996

GF-30AC. Ground Circuit Tester COMPLIANCE WESTUSA. Instruction Manual

AC DIELECTRIC TEST SET 600P Series

PBA Series Prelube Controls

BREAK-SAFE Load Break & Pick-up Tool

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Cart Power. Power Distribution System. Operation Manual Version 1.0 Copyright 2003 Professional Sound Corporation Printed in the U.S.A.

INSTALLATION GUIDE AND USER MANUAL

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

MODEL 422 Submersible Pump Controller

SOLAR-150HD. 150-Watt Dual Halogen Illuminator. Service Manual Bowdendale Avenue Jacksonville, FL 32216

LB LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS

1993 Lionel Trains, Inc., Chesterfield, MI LIONEL RS-I TRANSFORMER

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Instruction Manual. Fudge Puppy Display Case

POWERLINE 2000 Energy Management System TM

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Owner's Manual. LTS Load Shed Switch. This manual should remain with the unit.

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

MODEL ELC-12/40-CVM-D BATTERY CHARGER

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

Owner's Manual. LTS Load Shed Switch. This manual should remain with the unit.

CONTROL FEATURES AVAILABLE OPTIONS

03561 SPEED BOOSTER INSTRUCTION MANUAL. for the Ultra Tugger

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

MS2001L LPR Corrosion Monitor

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

Electric Vehicle Charging Station

Using Your SMT Micro Anodizer 0-120VDC/0-1A

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

GFM-200A. Instruction Manual

OLYMPIAN MODEL 740 Operation and Service Manual

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Transcription:

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0 MM September 21, 2012

TABLE OF CONTENTS Section Number DANGER INTRODUCTION AND TECHNICAL SPECIFICATIONS 1 CONTROL AND METERING DESCRIPTION 2 OPERATION AND CALIBRATION 3 CIRCUIT DIAGRAM SYMBOLS 4 ELECTRICAL DRAWINGS 5 PARTS LIST 6 RECOMMENDED SPARE PARTS 7 PARTS ORDERING INFORMATION 8 RETURNED MATERIAL 9

GENERAL SAFETY PRECAUTIONS HIGH VOLTAGE This equipment is capable of providing POTENTIALLY LETHAL VOLTAGES! Improper operation or test practices may result in injury or death to the operator or surrounding personnel. The operation of High Voltage test equipment should only be performed by personnel familiar with HIGH VOLTAGE testing and safety procedures. The operator of this equipment must be aware of all hazards associated with High Voltage testing. The operator is responsible for himself and others in close proximity of the testing area. Some General Safety Practices for working with High Voltage Test Equipment have been listed below for your reference. Become familiar with your instrument before performing an actual test Know your work area, check that all circuits are de-energized and locked out. Never work alone; always work with another qualified worker. Mark off entire work area with barriers and warning tape. Make all personnel aware of your testing activities. Be aware of dangerous conditions that may arise from energizing a test specimen. Never modify test equipment, modifications to equipment could introduce an unknown hazard or hinder a designed-in safety feature. DO NOT operate damaged equipment. Remove power, and do not use the equipment until safe operation can be verified by service-trained personnel. Phenix Technologies, Inc. assumes no liability for unsafe or improper use of test equipment.

INTRODUCTION 1-1 The Phenix Technologies VMS-1 Portable Power Supply is well equipped with the various features listed on the specifications page to allow for the easy testing of the operational voltage/current of electro-mechanical devices. The VMS-1 allows the user to carefully dial in an output voltage or current to determine the operational voltage or current levels needed for the switching state of various electro-mechanical devices. Both the voltage and current output levels can be simultaneously read and monitored with the highly accurate, onboard meters. The output terminals in the form of binding posts provide convenient hookup configurations depending on the type of component being tested.

1-2 TECHNICAL SPECIFICATIONS Model: VMS-1 Portable Power Supply Input: Output: 120 Volts, 10 Amps, 60 Hz, Single Phase 0-120VAC; 10AAC MAX through binding posts. Instrumentation: Features: Digital Voltmeter, 3 ½ digit resolution Scale: 0-199.9VAC. Accuracy: 0.4% FS 2 counts Digital Ammeter, 3 ½ digit resolution Scale: 0-19.99AAC. Accuracy: 0.15% FS 6 counts Main power circuit breaker with indicator lamp. Output via binding posts. Heavy-duty construction designed for continuous duty. Portable case with handle. Simultaneous digital readouts of both RMS Voltage and Current Two levels of adjustment: Coarse and Fine Push button resettable circuit breakers for Overload protection Onboard storage for Power Cord and Output leads and cables Two copies of instruction manual, parts list, and schematics Size: 20 L x 16 W x 7 H; 29 lbs.

2-1 CONTROL AND METERING DESCRIPTION (Key numbers refer to Figure 1) 1. Main Power In. 2. Main Power Circuit Breaker. Serves dual function as main switch and provides overload protection for all circuits in test set. 3. Main Power Indicator Lamp. Lights when main power circuit breaker is energized and in the ON position. 4. Coarse Adjust. Adjusts voltage and current output levels. 5. Fine Adjust. Adjusts voltage and current output with finer precision than coarse adjust knob. 6. Digital Voltmeter. Provides continuous display of output voltage in Volts. 7. Digital Ammeter. Provides continuous display of output current in Amps. 8. Overload Circuit Breakers. Push button circuit breakers for each adjustment circuit. Button will pop up when breaker is tripped, push down to reset breaker. 9. Output Binding Posts. Output connection terminals to hook up components to be tested with the power supply. 10. Cable Storage Area. Onboard cable storage for input power cord and output clip lead wires.

PHENIX TECHNOLOGIES

3-1 OPERATION AND CALIBRATION OPERATION Setup 1. Open unit and connect input power supply cord to the power inlet and a standard wall outlet. 2. Ensure Coarse and Fine adjustment knobs are dialed to their zeroed out positions before connecting output terminals. 3. If either of the two Overload circuit breakers are tripped, press the push button to reset the breakers. 4. Connect the output supply via the binding posts and hook up the component to be tested with the two leads that would switch the state of the component. Operation 5. Turn on main circuit breaker switch to power on unit. Note indicator light comes on. 6. Using the component manufacturer s current ratings as a guide, slowly dial the Coarse adjust to within 5V of the desired level. 7. Once the output is dialed to within a ~5V margin below the desired level, slowly dial the Fine adjust until the component activates. 8. Upon completion of testing, turn off main power by switching off the main breaker before disconnecting the output leads from the test component. 9. Disconnect input power cord and output power cables and place back into the onboard storage area after each use. 10. For safety reasons, dial back the Coarse and Fine adjust knobs to their zeroed out positions before placing the unit back in storage.

3-2 CALIBRATION Your VMS-1 portable power supply itself does not require any calibration for normal operation. The onboard digital Voltmeter and Ammeter will also hold its normally calibrated settings during the lifetime of your VMS-1 for all normal indoor operations. In the rare case that either meter needs calibration adjustments, the procedure for doing so should be performed by qualified technical personnel such as the Phenix Technologies Service Department during a scheduled service appointment. MAINTENANCE During the lifetime of your portable power supply, certain items will need replacement. Common replacement parts are listed on page 7-1 under Recommended Spare Parts. With the exception of the input and output cables, all other components that may need replacement require the removal of the front panel from the Portable Power Supply enclosure case. This is done through the removal of the mounting screws and washers along the perimeter of the front panel, and pulling the panel with its attached components from the enclosure. After the needed components are replaced, replace the front panel with the mounting screws and washers, carefully hand tightening the screws into place. Using screwdrivers or over-tightening the screws may cause the brass hardware to dislodge from the frame.

5-1 ELECTRICAL DIAGRAMS Drawing Number Description 1. 9907000 VMS-1 Electrical Schematic

6-1 VMS-1 PARTS LIST QTY. ITEM # PHENIX PART # DESCRIPTION 1 2100479 Portable Power Supply Case with Carry Handle 1 CON1 1153328 Screw MNT Power Inlet Receptacle 2 F1-2 1603601 AGC-1 Fuse 2 F1-2 1603910 Single Pole Fuse Holder for AGC type Fuse 1 CB1 1601310 10A Single Pole CKT BRKR 1 CB2 1601413 Push Button CKT BRKR 1A 1 CB3 1601423 Push Button CKT BRKR 10A 1 LP1 1423270 Neon Lamp Yellow 1 CON2 1351100 Binding Post Black 1 CON3 1351104 Binding Post White 1 T3 1890209 1210B Variable Transformer 1 T2 1890100 171 Variable Transformer 1 T1 1894431 100VA Transformer 1 VM1 1506511 Digital AC Voltmeter 1 CM1 1506512 Digital AC Current meter 1 1077164 Input Power Cord 16/3 10FT 2 N/A Output lead wires 1 1353205 Banana Plug Black 1 1356200 Banana Plug Red 2 1353042 Gator Clip 20 Amp 1 1353041 Gator Clip Boot Black 1 1353040 Gator Clip Boot Red

7-1 RECOMMENDED SPARE PARTS QTY. ITEM # PHENIX PART # DESCRIPTION 2 F1-2 1603601 AGC-1 Fuse 1 LP1 1423270 Neon Lamp Yellow 1 1077164 Power Cord 16/3 10FT 1 VM1 1506511 Digital AC Voltmeter 1 CM1 1506512 Digital AC Current meter 2 N/A Output lead wires 1 1353205 Banana Plug Black 1 1356200 Banana Plug Red 2 1353042 Gator Clip 20 Amp 1 1353041 Gator Clip Boot Black 1 1353040 Gator Clip Boot Red

8-1 PARTS ORDERING INFORMATION Replacement parts are available from Phenix Technologies, Inc. Changes to Phenix Technologies' products are sometimes made to accommodate improved components as they become available, and to give you the benefit of the latest technical improvements developed in our Engineering Department. It is, therefore, important when ordering parts to include the serial number of the unit as well as the part number of the replacement part. When your purchase order is received at our office, a representative of Phenix Technologies will contact you to confirm the current price of the part being ordered. If a part you order has been replaced with a new or improved part, an Applications Engineer will contact you concerning any change in part number. Your order for replacement parts should be sent to: Replacement Parts Department Phenix Technologies, Inc. 75 Speicher Drive Accident, Maryland 21520

9-1 RETURNED MATERIAL If for any reason it should become necessary to return this equipment to the factory, the Service Department of Phenix Technologies, Inc. must be given the following information: Name Plate Information Model Number Serial Number Reason for Return Cause of Defect If Phenix Technologies, Inc. deems return of the part appropriate, it will then issue an "Authorization for Return". If return is not deemed advisable, other inspection arrangements will be made. NOTE: Material received at this plant without the proper authorization shall be held as "Customer's Property" with no service until such time as the proper steps have been taken. Your cooperation is requested in order to ensure prompt service.