Rosemount 8750W Magnetic Flowmeter System

Similar documents
Rosemount 8750WB Magnetic Flowmeter System

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8700M Magnetic Flowmeter Platform

Rosemount 8700M Magnetic Flowmeter Platform

Rosemount 3051CFA Annubar Flowmeter

Rosemount 3051T In-Line Pressure Transmitter

ISTEC MAGNETIC METERS

Quick Start Guide , Rev CA March Rosemount 8750W Magnetic Flowmeter System for Utility, Water, and Wastewater Applications

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

Rosemount Magnetic Flowmeter Systems (Transmitter and Flowtube)

Electro-Magnetic Flowmeters Sensors MagMaster MFE

Appendix. Clearance. Skewed profiles. Application Schematics

Field IT Electro-Magnetic Flowmeters Sensors

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

F-2700 SERIES INSERTION VORTEX FLOW METER

Rosemount DP Flowmeters and Primary Elements

Model 8800C Vortex Flowmeter

FPI-X FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODEL 395X MAG METER SUBMITTAL

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

FPI Mag FULL PROFILE INSERTION ELECTROMAGNETIC FLOW METER MODELS 394L AND 395L MAG METER SUBMITTAL

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

Low Profile Insertion Vortex

Rosemount 8800D Series Vortex Flowmeter

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Rosemount 8800D Series Vortex Flowmeter

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Micro Motion F-Series Coriolis Flow and Density Meters

F-2700 SERIES INSERTION VORTEX FLOW METER

Rosemount 3051S Series of Instrumentation

VLM20 In-line Vortex Flowmeter

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Smart Pressure Transmitter

Electromagnetic Flow Meter Owner s Manual HARDWARE

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Continuous level measurement Capacitance transmitters

F-1500 SERIES INSERTION TURBINE FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Rosemount 8800D Series Vortex Flowmeter

Rosemount 3051S Electronic Remote Sensor (ERS) System

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

THE ROSEMOUNT 8800C DELIVERS RELIABILITY Rosemount Reliability -The 8800C Vortex eliates impulse lines, ports, and gaskets to improve reliabil

Rosemount 3051 Pressure Transmitter

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Armstrong In-Line and Insertion Vortex Flow Meters

Rosemount DP Flowmeters and Primary Elements

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Electromagnetic Flowmeters. Product Overview.

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

SATRON VVFe Pressure Transmitter

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Rosemount 8700 Series Magnetic Flowmeter Sensors

Rosemount 3051 Pressure Transmitter

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

M3500 Industrial Pressure Transmitter

Rosemount 4088 MultiVariable Transmitter

Hot Tap Insertion Vortex

Level Measurement Point level measurement - RF Capacitance switches

SATRON VDt Differential Pressure Transmitter

Rosemount 4088 MultiVariable Transmitter

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

UTM10 Series Ultrasonic Transit-time Flowmeters

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Magnetic-inductive flow meter for hazardous areas

Masoneilan Series

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Rosemount 3051S Series of Instrumentation

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Rosemount 3051S Series of Instrumentation

Level Measurement Continuous level measurement Ultrasonic transmitters

Detector (for water measurement applications)

CANADA SENSORS TECHNOLOGY INC.

UniMag DT Series Electromagnetic Flow Tubes

Rosemount 8800D Series Vortex Flowmeter

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Start FINAL. Step 8: Process Leak Protection (Optional) Step 9: Power up the Transmitter. Step 10: Check Process Connections

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

Ultra Mag SUBMITTAL PACKAGE

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Time Delta S Fixed Transit-Time Flow Meter System

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Micro Motion Model CNG050 Compressed Natural Gas Flowmeters

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Product Data Sheet , Rev GA Catalog Content

SATRON VT Pressure Transmitter

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Model FVP General Specification. Flanged Vortex Plate. Product Features

Transcription:

Product Data Sheet 00813-0300-4750, Rev CA February 2018 Rosemount 8750W Magnetic Flowmeter System for Utility, Water, and Wastewater Applications Best in class value with performance, reliability, and diagnostics suited for monitoring applications Reliable all welded coil housing and lightweight sensor design rated to IP68 Available in 4 20mA with HART, Modbus RS-485, Process Diagnostics, and SMART Meter Verification to improve reliability and performance Available with drinking water certifications

Product Selection Guide The Rosemount 8750W Magnetic Flowmetersensor is available in a flanged style and transmitter is available in remote and integral transmitter configurations to ensure compatibility with all utility, water, and wastewater applications. Transmitter selection Transmitter Field mount General characteristics Integral and remote configurations available HART/Analog and Pulse outputs available Modbus RS-485 and Pulse output available Advanced Diagnostics available Optical Switch local operator interface (optional) Two discrete channels (optional) Wall mount Wall mount configuration HART/Analog and Pulse outputs available Modbus RS-485 and Pulse output available Advanced Diagnostics available 15 button tactile key pad and LOI (optional) Two discrete channels (optional) Contents Product Selection Guide... 2 Magmeter Diagnostics... 3 Magnetic Flowmeter Sizing... 4 Ordering Information... 7 Product Specifications... 18 Product Certifications...32 Dimensional drawings... 32 2 www.rosemount.com

Sensor selection Table 1: Sensor Selection Sensor Flanged General characteristics Flanged process connections Welded coil housing ½-in. (15 mm) to 48-in. (1200 mm) Standard, reference, and bullet-nose electrodes available Selecting materials For guidance on selecting materials, refer to the Rosemount Magnetic Flowmeter Material Selection Guide (00816-0100-3033), available at www.emerson.com/rosemount. Magmeter Diagnostics Rosemount diagnostics reduce cost & improve output by enabling new practices Rosemount Magnetic Flowmeters provide device diagnostics that detect and warn of abnormal situations throughout the life of the meter - from installation to maintenance and meter verification. With Rosemount Magnetic Flowmeter diagnostics enabled, plant availability and throughput can be improved, and costs through simplified installation, maintenance and troubleshooting can be reduced. Table 2: Magnetic flowmeter diagnostics Diagnostic name Diagnostic category Product capability Basic diagnostics Tunable Empty Pipe Process Standard Electronics Temperature Meter Health Standard Coil Fault Meter Health Standard Transmitter Fault Meter Health Standard Reverse Flow Process Standard Coil current Maintenance Standard Electrode saturation Process/Maintenance Standard Advanced diagnostics High Process Noise Process Suite 1 (DA1) Grounding and Wiring Fault Installation Suite 1 (DA1) Coated Electrode Detection Process Suite 1 (DA1) Commanded Smart Meter Verification Meter Health Suite 2 (DA2) Continuous Smart Meter Verification Meter Health Suite 2 (DA2) www.rosemount.com 3

Table 2: Magnetic flowmeter diagnostics (continued) Diagnostic name Diagnostic category Product capability 4-20 ma Loop Verification (1) Installation Suite 2 (DA2) (1) Available with HART output only. Options for accessing diagnostics Rosemount Magmeter Diagnostics can be accessed through the Local Operator Interface (LOI), ProLink III v3.1, a HART Field Communicator (1), and AMS Suite: Intelligent Device Manager (1). Contact your local Rosemount representative to activate diagnostics or for diagnostic availability on existing transmitters. Access diagnostics through the LOI for quicker installation, maintenance, and meter verification Rosemount Magnetic Flowmeter Diagnostics are available through the LOI to simplify maintenance. Access diagnostics through ProLink III v. 3.0 (HART)/ProLink III v. 3.1 (HART, Modbus) Simplify maintenance and troubleshooting practices by utilizing ProLink III v3.0/v3.1 to access diagnostics and troubleshooting information, log variable data, run SMART Meter Verification, and print verification reports. Access diagnostics through AMS Intelligent Device Manager (1) for the ultimate value The value of the diagnostics increases significantly when AMS Intelligent Device Manager is used. AMS Intelligent Device Manager provides a simplified screen flow and procedures for how to respond to the diagnostic messages. Magnetic Flowmeter Sizing Selecting the appropriate sensor size is an important step when considering a magnetic flowmeter. The physical properties of the process fluid, as well as the fluid velocity should be considered. It may be necessary to select a flow sensor that is larger or smaller than the adjacent piping to ensure the fluid velocity is in the recommended flow range for the application. Operation outside these guidelines may also give acceptable performance. Table 3: Sizing guidelines Application Velocity range (ft/s) Velocity range (m/s) Normal Service 0 39 0 12 Preferred Service 2 20 0.6 6.1 Note Operation outside these guidelines may also give acceptable performance. To convert flow rate to velocity, use the appropriate factor listed in Table 4 and the following equation: Velocity = Flow Rate Factor (1) Available with HART output only. 4 www.rosemount.com

Example: English units Magmeter Size: 4 in. (factor from Table 4 = 39.679) Normal Flow Rate: 300 GPM Example: SI units Magmeter Size: 100 mm (factor from Table 4 = 492.78)Normal Flow Rate: 800 L/min Velocity = 300 (gpm) 39.679 Velocity = 800 (L/min) 492.78 Velocity = 7.56 ft/s Velocity = 1.62 m/s Table 4: Line size vs. conversion factor Nominal line sizeinches (mm) Gallons per minute factor Liters per minute factor ½ (15) 0.947 11.762 1 (25) 2.694 33.455 1½ (40) 6.345 78.806 2 (50) 10.459 129.89 2 ½ (65) 14.923 185.33 3 23.042 286.17 4 (100) 39.679 492.78 5 (125) 62.356 774.42 6 (150) 90.048 1,118.3 8 155.93 1,936.5 10 245.78 3,052.4 12 (300) 352.51 4,378.0 14 (350) 42 5,237.3 16 (400) 550.80 6,840.6 18 (450) 697.19 8,658.6 20 (500) 866.51 10,761 24 1,253.2 15,564 30 (750) 2006.0 24,913 36 (900) 2,935.0 36,451 40 (1000) 3,652.1 45,357 42 (1050) 4,115.1 51,107 48 (1200) 5,407.6 67,159 www.rosemount.com 5

Table 5: Line size vs. velocity/rate Nominal line size in inches (mm) Minimum/maximum flow rate Gallons per minute at 0.04 ft/s (low-flow cutoff) at 1 ft/s (min range setting) at 3 ft/s at 39.37 ft/s (max range setting) Liters per minute at 0.012 m/s (low-flow cutoff) at 0.3 m/s (min range setting) at 1 m/s at 12 m/s (max range setting) ½ (15) 0.038 0.947 2.841 37.287 0.141 3.529 11.76 141.15 1 (25) 0.108 2.694 8.081 106.05 0.401 10.04 33.45 401.46 1½ (40) 0.254 6.345 19.04 249.82 0.946 23.64 78.81 945.67 2 (50) 0.418 10.459 31.38 411.77 1.559 38.97 129.89 1,558.7 2½ (65) 0.597 14.923 44.77 587.51 2.224 55.60 185.33 2,224.0 3 0.922 23.042 69.13 907.17 3.434 85.85 286.17 3,434.0 4 (100) 1.587 39.679 119.04 1,562.2 5.913 147.84 492.78 5,913.4 5 (125) 2.494 62.356 187.07 2,454.9 9.293 232.33 774.42 9,293.0 6 (150) 3.602 90.048 270.14 3,545.2 13.42 335.50 1,118.3 13,420 8 6.237 155.93 467.79 6,138.9 23.24 580.96 1,936.5 23,238 10 9.831 245.78 737.34 9,676.3 36.63 915.73 3,052.4 36,629 12 (300) 14.10 352.51 1,057.5 13,878 52.54 1,313.4 4,378.0 52,535 14 (350) 16.87 421.71 1,265.1 16,603 62.85 1,571.2 5,237.3 62,848 16 (400) 22.03 550.80 1,652.4 21,685 82.09 2,052.2 6,840.6 82,087 18 (450) 27.89 697.19 2,091.6 27,448 103.90 2,597.6 8,658.6 103,903 20 (500) 34.66 866.51 2,599.5 34,114 129.14 3,228.4 10,761 129,137 24 50.13 1,253.2 3,759.6 49,339 186.77 4,669.2 15,564 186,769 30 (750) 80.24 2,006.0 6,018.0 78,976 298.96 7,474.0 24,913 298,959 36 (900) 117.40 2,935.0 8,805.1 115,553 437.42 10,935 36,451 437,416 40 (1000) 146.09 3,652.1 10,956 143,785 544.29 13,607 45,357 544,286 42 (1050) 164.60 4,115.1 12,345 162,011 613.28 15,332 51,107 613,278 48 (1200) 216.30 5,407.6 16,223 212.898 805.91 20,148 67,159 805,908 Upstream and downstream piping To ensure specified accuracy over widely varying process conditions, install the sensor with a minimum of five straight pipe diameters upstream and two pipe diameters downstream from the electrode plane. 6 www.rosemount.com

February 2018 Figure 1: Upstream and downstream straight pipe diameters A. Five pipe diameters (upstream) B. Two pipe diameters (downstream) C. Flow direction Installations with reduced upstream and downstream straight runs are possible. In reduced straight run installations, the meter may not meet absolute accuracy specifications. Reported flow rates will still be highly repeatable. Sensor grounding A reliable ground path is required between the sensor and the process fluid. Optional grounding rings or process reference electrodes are available with 8750W Sensors to ensure proper grounding. See Table 5 and Table 6. Ordering Information Rosemount 8750W Magnetic Flowmeter Platform The Rosemount 8750W Magnetic Flowmeter is available in a flanged sensor design. The sensors are fabricated from stainless and carbon steel and welded to provide a sealed coil housing that protects against moisture or other contaminants. Sizes range from 1/2-in. (15 mm) to 48-in. (1200 mm). The field mount transmitter has a die cast aluminum housing for excellent reliability. The wall mount transmitter features an easy to use operator interface. Both transmitter styles are available with advanced diagnostics to provide the best insight into the process and the meter's health. Note The starred ( ) offerings represent the most common options, and should be selected for best delivery. Model code structure Example model code with one selection out of each category: 8750W D M T 1 A 1 F P S A 010 C A1 Z5 DA2 AX M4 BD G5 B6 R15 V1 Q4 HR7 WG YF Table 6: Requirements - select one from each available choice Example code Category 8750W Base model Magnetic Flowmeter System (utility, water, and wastewater) D Sensor design revision Revision "D" M Transmitter class (Table 8) T Transmitter mount (Table 9) 1 Transmitter power (Table 10) www.rosemount.com 7

Table 6: Requirements - select one from each available choice (continued) Example code Category A Transmitter outputs (Table 11) 1 Conduit entries (Table 12) F Sensor style (Table 13) P Lining material (Table 14) S Electrode material (Table 15) A Electrode type (Table 16) 010 Line size (Table 17) C Flange type and material (Table 18) A1 Flange rating (Table 19) Table 7: Options - select only as needed Example code Category Z5 Hazardous area certifications (Table 20) DA2 Advanced diagnostics (Table 21) AX Discrete input/output (Table 22) M4 Display (Table 23) BD Certifications (Table 24) G5 Grounding rings (Table 25) B6 Miscellaneous (Table 26) R15 Submergence protection (Table 27) V1 Special paint (Table 28) Q4 Quality certificates (Table 29) HR7 Revision configuration (Table 30) WG Witness inspection (Table 31) Yx Quick Start Guide language (Table 32) Requirements Table 8: Rosemount 8750W transmitter class Description M Revision 4 electronics 0 Spare sensor, no transmitter Table 9: Rosemount 8750W transmitter mount Description T Integral field mount R Remote field mount 8 www.rosemount.com

Table 9: Rosemount 8750W transmitter mount (continued) Description W Remote wall mount Table 10: Rosemount 8750W transmitter power Description 1 AC Power Supply (90-250VAC, 50/60Hz) 2 DC Power Supply (12-42VDC) 0 Spare sensor, no transmitter Table 11: Rosemount 8750W transmitter outputs Description A 4-20mA output with digital HART protocol & scalable pulse output M Modbus RS-485 electronics, scalable pulse 0 Spare sensor, no transmitter Table 12: Rosemount 8750W conduit entries Description Integral mount quantity Remote mount quantity 1 ½ 14 NPT 2 4 2 M20 adapters 2 4 4 (1) ½ 14 NPT, additional entry 3 5 5 (1) M20, additional entry 3 5 0 Spare sensor, integral mount only, no transmitter (1) Not available with the wall mount transmitter. N/A N/A Table 13: Rosemount 8750W sensor style Description F Flanged 0 Spare transmitter, no sensor Table 14: Rosemount 8750W lining material Description T (1) PTFE P (2) Polyurethane N (3) Neoprene 0 Spare transmitter, no sensor (1) Available in ½ - to 36-in. (15 mm to 900 mm) line sizes. (2) Available in line sizes 1- to 36-in., 42-in., and 48-in. (25 mm to 900 mm, 1050 mm, and 1200 mm) line sizes. (3) Available in line sizes 1- to 48-in. (25 mm to 1200 mm) line sizes. www.rosemount.com 9

Table 15: Rosemount 8750W electrode material Description S 316L stainless steel H Nickel alloy 276 (UNS N 10276) 0 Spare transmitter, no sensor Table 16: Rosemount 8750W electrode type Description A 2 Measurement electrodes standard B (1) 2 Measurement electrodes bulletnose E 2 Measurement electrodes plus 1 reference electrode standard F (1) 2 Measurment electrodes plus 1 reference electrode bulletnose 0 Spare transmitter, no sensor (1) Not available in ½-in. (15mm). Table 17: Rosemount 8750W line size Line size 005 ½-in. (15 mm) Liner availability In this table, the starred ( ) offerings represent available liner based on line size. Consult factory for additional Flange Type/Rating sensor availability PTFE code T Poly code P Neoprene code N 010 1-in. (25 mm) 015 1½-in. (40 mm) 020 2-in. (50 mm) 025 2½-in. (65 mm) 030 3-in. (80 mm) 040 4-in. (100 mm) 050 5-in. (125 mm) 060 6-in. (150 mm) 080 8-in. (200 mm) 100 10-in. (250 mm) 120 12-in. (300 mm) 140 14-in. (350 mm) 160 16-in. (400 mm) 180 18-in. (450 mm) 200 20-in. (500 mm) 240 24-in. (600 mm) 300 30-in. (750 mm) 360 36-in. (900 mm) 400 40-in. (1000 mm) 10 www.rosemount.com

Table 17: Rosemount 8750W line size (continued) Line size Liner availability In this table, the starred ( ) offerings represent available liner based on line size. Consult factory for additional Flange Type/Rating sensor availability PTFE code T Poly code P Neoprene code N 420 42-in. (1050 mm) 480 48-in. (1200 mm) 000 Spare transmitter, no sensor Table 18: Rosemount 8750W flange type and material Description (see Table 33 for line size vs. flange type and rating) C Slip-on,raised-face, carbon steel S Slip-on,raised-face, 304/304L SST F Slip-on, flat-face, carbon steel G Slip-on,flat-face, 304/304L SST 0 Spare transmitter, no sensor Table 19: Rosemount 8750W flange rating Description (see Table 33 for line size vs. flange type and rating) A1 ASME B16.5, Class 150 A3 ASME B16.5, Class 300 AD AWWA C207Class D; line size 30-in. and above; flat face flange only AE AWWA C207Class E; line size 30-in. and above; flat face flange only DD EN1092-1,PN10 DE EN1092-1,PN16 DF EN 1092-1, PN25 DH EN 1092-1, PN40 GD GB/T9119,PN10 GE GB/T9119,PN16 GH GB/T9119,PN40 JP JISB2220, 10K JR JISB2220, 20K KU AS4087, PN16 KW AS4087, PN21 KY AS4087, PN35 TK AS2129, Table D TL AS2129, Table E 00 Spare transmitter, no sensor www.rosemount.com 11

Options Note These are not required, but they must be included in the model number if desired. Table 20: Rosemount 8750W hazardous area certifications Description - (1) Ordinary Locations - (no code required) Z5 US Approvals, Class I Div 2, Non-Incendive and Dust for Non-Flammable Fluids Z6 Canadian Approvals, Class I Div 2, Non-Incendive and Dust for Non-Flammable Fluids ND ATEX Dust Z1 ATEX Non-Sparking and Dust for Non-Flammable Fluids NF IECEx Dust Z7 IECEx Non-Sparking and Dust for Non-Flammable Fluids Z3 NEPSI Non-Sparking and Dust for Non-Flammable Fluids (1) CSA (C/US) marked, CE marked, EAC marked and C-tick marked. Table 21: Rosemount 8750W advanced diagnostics DA1 Description Process Diagnostics, High Process Noise Detection, Ground/Wiring Fault Detection, and Electrode Coating DA2 Smart Meter Verification Table 22: Rosemount 8750W discrete input/discrete output Description AX (1) Two Discrete Channels (DI/DO 1, DO 2) (1) Requires Conduit Entry code 4 or 5 when ordered with field mount transmitter. Table 23: Rosemount 8750W display Description M4 LCD with Local Operator Interface M5 (1) (1) Field mount transmitter only. LCD display only Table 24: Rosemount 8750W certifications Description PD European Pressure Equipment Directive Certification (PED) CR Canadian Registration Number (CRN) Certification BD ASME B31.3 Process Piping Standard 12 www.rosemount.com

Table 24: Rosemount 8750W certifications (continued) Description DW (1) NSF DrinkingWater Certification (1) NSF drinking water certification is available with the PTFE liner in line sizes 0.5- to 36-in (15 mm to 900 mm) and the polyurethane liner in line sizes 4-to 36-in., 42-in., and 48-in. (80 mm to 900 mm, 1050 mm, and 1200 mm). Table 25: Rosemount 8750W grounding rings Description G1 316L stainless steel (Qty 2) G2 Nickel alloy C-276; UNS N 10276 (Qty 2) G5 316L stainless steel (Qty 1) G6 Nickel alloy C-276; UNS N 10276 (Qty 1) Table 26: C1 D1 B6 P05 (1) Rosemount 8750W miscellaneous Description Custom Configuration (completed CDS form required with order) High Accuracy Calibration (base ref accuracy 0.25% of rate) 316 SST Mounting Bracket with U-bolt Kit for 2-in. Pipe Mount 5-point verification P10 (2) 10-point verification (1) Available for ½ - to 24-in (15 mm to 600 mm) at velocities 1, 3, 5, 7, 10 ft/s; 30-in. (700 mm) at velocities 1, 3, 5, 7, 9.5 ft/s; 36-in. (900 mm) at velocities 1, 2, 3, 5,6.5 ft/s;40- to 48-in.(1000mm to 1200mm). (2) Available for ½ - to 24-in. (15 mm to 600 mm) at velocities 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 ft/s; 30- to 48-in. (700 mm to 1200 mm) not available. Table 27: R05 R10 R15 R20 R25 R30 Rosemount 8750W submergence protection Description Potted junction box with 50 feet of combo cable/cable gland Potted junction box with 100 feet of combo cable/cable gland Potted junction box with 150 feet of combo cable/cable gland Potted junction box with 200 feet of combo cable/cable gland Potted junction box with 250 feet of combo cable/cable gland Potted junction box with 300 feet of combo cable/cable gland Table 28: V1 Rosemount 8750W special paint Description Coal tar paint (submersible/direct burial) Table 29: Rosemount 8750W quality certificates Description Q4 Calibration certificate per ISO 10474 3.1B/EN 10204 3.1 Q8 Material traceability per ISO 10474 3.1B/EN 10204 3.1 www.rosemount.com 13

Table 30: Rosemount 8750W revision configuration Description HR7 HART Revision 7 Table 31: WG Rosemount 8750W witness inspection Description Witness Inspection Table 32: Rosemount 8750W Quick Start Guide language Description YF French YG German YI Italian YK Korean YM Chinese (Mandarin) YP Portuguese (Brazil) YR Russian YS Spanish Table 33: Slip on flange options by line size Size code Flange code and rating A1 A3 AD AE DD DE DF DH GD GE GH JP JR KU KW KY TK TL ASME Class 150 ASME Class 300 AWWA Class D AWWA Class E EN PN10 EN PN16 EN PN25 EN PN40 005 010 015 020 025 030 040 050 060 080 100 120 140 160 GB/T PN 10 14 www.rosemount.com GB/T PN 16 GB/T PN 40 JIS 10K JIS 20K AS4087 PN16 AS4087 PN21 AS4087 PN35 AS2129 Table D AS2129 Table E

Table 33: Slip on flange options by line size (continued) Size code Flange code and rating A1 A3 AD AE DD DE DF DH GD GE GH JP JR KU KW KY TK TL ASME Class 150 ASME Class 300 AWWA Class D AWWA Class E EN PN10 EN PN16 EN PN25 EN PN40 180 200 240 300 360 400 420 480 GB/T PN 10 GB/T PN 16 GB/T PN 40 JIS 10K JIS 20K AS4087 PN16 AS4087 PN21 AS4087 PN35 AS2129 Table D AS2129 Table E www.rosemount.com 15

Ordering flowmeter equipment Ordering procedure To order, select the desired sensor and/or transmitter by specifying model codes from the ordering table. For remote transmitter applications, note the cable specification requirements. Standard configuration Unless the Configuration Data Sheet is completed, the transmitter will be shipped as follows: Engineering units: ft/sec 4mA: 0 20mA: 30 Sensor size: Empty pipe: 3-in. On Sensor calibration number: 1000005010000000 Integrally mounted transmitters are factory configured with the paired sensor size and appropriate calibration number. Custom configuration (option code C1) If Option C1 is ordered, the Configuration Data Sheet (CDS) must be submitted at the time of order. Standard tagging Instrument tags for the transmitter and sensors are as follows: 316SST laser etched label, permanently attached Main label - Tag name: 1 line 21characters Additional 316SST 'wire-on' tag available: 5 lines, 17 characters per line (6mm height) Interconnecting cable Interconnecting cables are required to connect a remote mount transmitter to the sensor. When ordering cable, review the hazardous area approval requirements and the installation location requirements for proper cable selection. Cables can be ordered as individual component cables or a combination coil drive/electrode cable. Cables can be ordered as part of the transmitter model number or as a spare parts kit. Integrally mounted transmitters are factory wired and do not require additional interconnecting cables. Individual component cables require equal lengths of coil drive cable and electrode cable and should be limited to less than 500 feet (152 m). Consult Technical Support for lengths between 500-1000 feet (152-304 m). Combination coil drive/electrode cable is only available for Ordinary Locations and should be limited to less than 330 feet (100 m). Component cable kits Standard temp (-20 C to 75 C) Cable kit # Description Component Rosemount p/n Alpha p/n 08732-0065-0001 (feet) 08732-0065-0002 (meters) Kit, Component Cables, Std Temp, (includes Coil and Electrode) Kit, Component Cables, Std Temp (includes Coil and Electrode) Coil 08732-0060-0001 2442C Electrode 08732-0061-0001 2413C Coil 08732-0060-0002 2442C Electrode 08732-0061-0002 2413C 16 www.rosemount.com

Standard temp (-20 C to 75 C) 08732-0065-0003 (feet) 08732-0065-0004 (meters) Kit, Component Cables, Std Temp (includes Coil and I. S. Electrode) Kit, Component Cables, Std Temp (includes Coil and I. S. Electrode) Coil 08732-0060-0001 2442C I. S. Electrode 08732-0061-0003 Not available Coil 08732-0060-0002 2442C I.S. Electrode 08732-0061-0004 Not available Extended temp (-50 C to 125 C) Cable kit # Description Component Rosemount p/n Alpha p/n 08732-0065-1001 (feet) 08732-0065-1002 (meters) 08732-0065-1003 (feet) 08732-0065-1004 (meters) Kit, Component Cables, Ext Temp (includes Coil and Electrode) Kit, Component Cables, Ext Temp (includes Coil and Electrode) Kit, Component Cables, Ext Temp (includes Coil and I. S. Electrode) Kit, Component Cables, Ext Temp (includes Coil and I. S. Electrode) Coil 08732-0060-1001 Not available Electrode 08732-0061-1001 Not available Coil 08732-0060-1002 Not available Electrode 08732-0061-1002 Not available Coil 08732-0060-1001 Not available I. S. Electrode 08732-0061-1003 Not available Coil 08732-0060-1002 Not available I.S. Electrode 08732-0061-1004 Not available Combo cable kits Coil/electrode cable (-20 C to 80 C) Cable Kit # (1) 08732-0065-2001 Kit, Combo Cable, Standard (feet) 08732-0065-2002 (meters) 08732-0065-3001 Kit, Combo Cable, Submersible (2) (feet) 08732-0065-3002 (meters) (1) Only available for Ordinary Locations. (2) 80 C dry/60 C wet/33ft continuous submergence. www.rosemount.com 17

Product Specifications Basic specifications The tables below outline some of the basic performance, physical, and functional specifications. Table 34: Wall mount transmitter Specifications Style Wall mount Base accuracy (1) 0.5% Standard 0.25% High Accuracy Option Mounting Remote Power supply Global AC or DC User interface 15 button tactile keypad Communication protocol HART or Modbus RS-485 Diagnostics Basic, DA1, DA2 Sensor compatibility All Rosemount plus other manufacturers Detailed specifications Transmitter specifications Ordering information Ordering Information (1) For complete accuracy specifications, please refer to Transmitter functional specifications. Table 35: Field mount transmitter specifications Style Field mount Base accuracy (1) 0.5% Standard 0.25% High Accuracy Option Mounting Integral or Remote Power supply Global AC or DC User interface 4 Optical Switch LOI or no display Communication protocol HART or Modbus RS-485 Diagnostics Basic, DA1, DA2 Sensor compatibility All Rosemount plus other manufacturers Detailed specifications Transmitter specifications Ordering information Ordering Information (1) For complete accuracy specifications, please refer to Transmitter functional specifications. Table 36: Sensor specifications Style Base accuracy (1) Line sizes Design features Detailed specifications Flanged 0.5% Standard 0.25% High Accuracy Option ½-in. to 48-in. (15 mm to 1200 mm) Standard Process Design Sensor specifications 18 www.rosemount.com

Table 36: Sensor specifications (continued) Ordering information (1) For complete accuracy specifications, refer to the sensor detailed specifications. Ordering Information Table 37: Lining Material Selection Liner material PTFE General characteristics Highly chemical resistant Excellent high temperature capabilities Process temperature: -58 to 350 F (-50 to 177 C) Polyurethane Limited chemical resistance Excellent abrasion resistance for slurries with small and medium particles Process temperature: 0 to 140 F (-18 to 60 C) Typically applied in clean water Neoprene Very good abrasion resistance for small and medium particles Better chemical resistance than polyurethane Typically applied in water with chemicals, and sea water Preferred liner for high pressure > ASME B16.5 Class 900 Process temperature: 0 to 176 F (-18 to 80 C) Table 38: Electrode Material Electrode material 316L Stainless Steel Nickel Alloy 276 (UNS N10276) General characteristics Good corrosion resistance Good abrasion resistance Not recommended for sulfuric or hydrochloric acids Better corrosion resistance High strength Good in slurry applications Effective in oxidizing fluids Table 39: Electrode Type Electrode type Standard Measurement Measurement + Reference Electrode General characteristics Lowest cost Good for most applications Low cost grounding option especially for large line sizes Minimum conductivity of 100 microsiemens/cm www.rosemount.com 19

Table 39: Electrode Type (continued) Electrode type (Also see Table 40 and Table 41 for grounding options and installation) Bulletnose General characteristics Not recommended for electrolytic or galvanic corrosion applications Extended head protrudes into the flow stream for self-cleaning Best option for coating processes Table 40: Process Reference Options Grounding options No Grounding Options (grounding straps) Reference Electrode Grounding Rings General characteristics Acceptable for conductive unlined pipe Grounding straps provided at no cost Same material as measurement electrodes Sufficient grounding option when process fluid conductivity is greater than 100 microsiemens/cm Not recommended in electrolysis applications, galvanic corrosion applications, applications where the electrodes may coat, or non-conductive pipe. Low conductivity process fluids Cathodic or electrolysis applications that may have stray currents in or around the process Variety of materials for process fluid compatibility Table 41: Process Reference Installation Type of pipe Grounding straps Grounding rings Reference electrode Lining protectors Conductive unlined pipe Acceptable Not required Not required Not required Conductive lined pipe Not acceptable Acceptable Acceptable Acceptable Non-conductive pipe Not acceptable Acceptable Not recommended Acceptable Transmitter specifications Transmitter functional specifications Transmitter coil drive current 500mA Flow rate range Capable of processing signals from fluids with velocities between 0.04 and 39 ft/s (0.01 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full scale continuously adjustable between 39 and 39 ft/s ( 12 to 12 m/s). Conductivity limits Process liquid must have a conductivity of 5 microsiemens/cm (5 micromhos/cm) or greater. 20 www.rosemount.com

Power supply 90-250VAC @ 50/60Hz or 12-42VDC Line power fuses 90-250VAC systems: - 2 amp quick acting - Bussman AGC2 or equivalent 12-42VDC systems - 3 amp quick acting - Bussman AGC3 or equivalent Power consumption 90-250VAC: 40VA maximum 12-42VDC: 15W maximum Switch-on current At 250VAC: Maximum 35.7A (< 5ms) At 42VDC: Maximum 42A (< 5ms) AC power supply requirements Units powered by 90-250VAC have the following power requirements. Peak inrush is 35.7A at 250VAC supply, lasting approximately 1ms. Inrush for other supply voltages can be estimated with: Inrush (Amps) = Supply (Volts) / 7.0 Figure 2: AC current requirements A 0.24 0.22 0.20 0.18 0.16 0.14 0.12 90 110 130 150 170 B 190 210 230 250 A. Supply current (amps) B. Power supply (VAC) Figure 3: Apparent power A 34 32 30 28 26 24 22 20 90 110 130 150 170 B 190 210 230 250 A. Apparent power (VA) B. Power supply (VAC) DC power supply requirements Units powered by 12VDC power supply may draw up to 1.2A of current steady state. Peak inrush is 42A at 42VDC supply, lasting approximately 1ms. Inrush for other supply voltages can be estimated with: Inrush (Amps) = Supply (Volts) / 1.0 www.rosemount.com 21

Figure 4: DC current requirements A 1.2 1.1 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 12 17 22 27 B A. Supply current (amps) B. Power supply (VDC) 32 37 42 Ambient temperature limits Operating: - 58 to 140 F ( 50 to 60 C) without local operator interface - 4 to 140 F ( 20 to 60 C) with local operator interface - The Local Operator Interface (LOI) will not display at temperatures below -20 C Storage: - 58 to 185 F ( 50 to 85 C) without local operator interface - 22 to 176 F ( 30 to 80 C) with local operator interface Humidity limits 0 95% RH to 140 F (60 C) Altitude 2000 meters maximum Enclosure rating Type 4X, IEC 60529, IP66 (transmitter) Transient protection rating Built in transient protection that conforms to: IEC 61000-4-4 for burst currents IEC 61000-4-5 for surge currents IEC 611185-2.2000, Class 3 up to 2kV and up to 2kA protection Turn-on time 5 minutes to rated accuracy from power up 5 seconds from power interruption Start-up time 50ms from zero flow Low flow cut-off Adjustable between 0.01 and 38.37 ft/s (0.003 and 11.7 m/s). Below selected value, output is driven to the zero flow rate signal level. 22 www.rosemount.com

Overrange capability Signal output will remain linear until 110% of upper range value or 44 ft/s (13 m/s). The signal output will remain constant above these values. Out of range message displayed on LOI and the Field Communicator. Damping Adjustable between 0 and 256 seconds Advanced diagnostics capabilities Basic Self test Transmitter faults Analog output test Pulse output test Tunable empty pipe Reverse flow Coil circuit fault Electronics temperature Process diagnostics (DA1) Ground/wiring fault High process noise Electrode coating diagnostic Smart Meter Verification (DA2) Smart Meter Verification (continuous or on-demand) 4-20mA loop verification (2) Output signals Analog output adjustment (3) 4 20mA, switch-selectable as internally or externally powered. Analog loop load limitations Internally powered 24VDC max, 500 ohms max loop resistance Externally powered 10.8-30VDC max. Loop resistance is determined by the voltage level of the external power supply at the transmitter terminals: (2) Available with HART output only. (3) For transmitters with intrinsically safe outputs (option code B), power must be supplied externally. www.rosemount.com 23

Figure 5: Analog loop load limitations 600 A C 0 10.8 30 A. Load (ohms) B. Power supply (volts) C. Operating region R max = 31.25 (V ps 10.8) V ps = power supply voltage (volts) Rmax = maximum loop resistance (ohms) B The analog output is automatically scaled to provide 4mA at lower range value and 20mA at upper range value. Full scale continuously adjustable between -39 and 39 ft/s (-12 to 12 m/sec), 1 ft/s (0.3 m/s) minimum span. HART Communications is a digital flow signal. The digital signal is superimposed on the 4 20mA signal and is available for the control system interface. A minimum of 250 ohms loop resistance is required for HART communications. Analog alarm mode High or low alarm signal is user-selectable via the Alarm switch on the front of the electronics. NAMUR-compliant alarm limits are software configurable and can be preset via CDS (C1). Individual diagnostic alarms are also software configurable. Alarms will drive the analog signal to the following ma values. High or low alarm signal is user-selectable via the Alarm switch on the front of the electronics. NAMUR-compliant alarm limits are software configurable and can be preset via CDS (C1). Individual diagnostic alarms are also software configurable. Alarms will drive the analog signal to the following ma values. Low 3.75 ma Requires CDS (C1) High 22.50 ma Factory default NAMUR Low 3.5 ma Requires CDS (C1) NAMUR High 22.6 ma Requires CDS (C1) Modbus RS-485 Output Transmitters with a Modbus output provide an RS-485 signal to a Modbus host system; data rates can be configured from 1200 baud to 115.2 kilobaud. Scalable pulse frequency adjustment (4)(5) 0-10,000Hz, switch-selectable as internally or externally powered Pulse value can be set to equal desired volume in selected engineering units Pulse width adjustable from 0.1 to 650 ms Internally powered: Outputs up to 12VDC (4) For transmitters with intrinsically safe outputs (option code B), power must be supplied externally. (5) For transmitters with intrinsically safe outputs (option code B), frequency range is limited to 0-5000Hz. 24 www.rosemount.com

Externally powered: Input 5-28VDC Output testing Analog output test (4) Pulse output test (5) Transmitter may be commanded to supply a specified current between 3.5 and 23mA. Transmitter may be commanded to supply a specified frequency between 1 and 10,000Hz. Optional discrete output function (AX option) Externally powered at 5-28VDC, 240mA max, solid state switch closure to indicate either: Reverse flow Activates switch closure output when reverse flow is detected. Zero flow Empty pipe Transmitter faults Flow limit 1, flow limit 2 Totalizer limit Diagnostic status Activates switch closure output when flow goes to 0 ft/s or below low flow cutoff. Activates switch closure output when an empty pipe condition is detected. Activates switch closure output when a transmitter fault is detected. Activates switch closure output when the transmitter measures a flow rate that meets the conditions established for this alert. There are two independent flow limit alerts that can be configured as discrete outputs. Activates switch closure output when the transmitter measures a total flow that meets the conditions established for this alert. Activates switch closure output when the transmitter detects a condition that meets the configured criteria of this output. Optional discrete input function (AX option) Externally powered at 5-28VDC, 1.4-20mA to activate switch closure to indicate either: Reset Totalizer A (or B or C) Resets Totalizer A (or B or C) value to zero. Reset All Totals Positive Zero Return (PZR) Resets all totalizer values to zero. Forces outputs of the transmitter to zero flow. Security lockout Security lockout switch on the electronics board can be set to deactivate all LOI and HART-based communicator functions to protect configuration variables from unwanted or accidental change. LOI lockout The display can be manually locked to prevent unintentional configuration changes. The display lock can be activated through a HART communication device, or by holding the UP arrow for 3 seconds and then following the on-screen instructions. When the display lock is activated, a lock symbol will appear in the lower right hand corner of the display. To deactivate the display lock, hold the UP arrow for 3 seconds and follow the on-screen instructions. Display auto lock can be configured from the LOI with the following settings: OFF, 1 Minute, or 10 Minutes Sensor compensation Rosemount sensors are calibrated in a flow lab at the factory and are assigned a calibration number. The calibration number must be entered into the transmitter, enabling interchangeability of sensors without calculations or a compromise in standard accuracy. Transmitters and other manufacturers sensors can be calibrated at known process conditions or at the Rosemount NIST-Traceable Flow Facility. Transmitters calibrated on site require a two-step procedure to match a known flow rate. This procedure can be found in the operations manual. www.rosemount.com 25

Performance specifications System specifications are given using the frequency output and with the unit at reference conditions. Accuracy Includes the combined effects of linearity, hysteresis, and repeatability. Standard system accuracy: - ±0.5% of rate from 1 to 39 ft/s (0.3 to 12 m/s) - ±0.005 ft/s (0.0015 m/s) from the low flow cutoff to 1 ft/s (0.3 m/s) Optional high accuracy: (6) - ±0.25% of rate ±1.0 mm/sec from 3 to 39 ft/s (1 to 12 m/s) 2.5 2.0 A 1.5 1.0 0.5 0.5% 0.25% 0 0 3 (1) 6 (2) A. Percentage of rate B. Velocity in ft/s (m/s) 12 (4) B 18 (6) 24 (8) 30 (10) Analog output effects Analog output has the same accuracy as frequency output plus an additional ±4 μ A at room temperature. Repeatability Response time (analog output) Stability Ambient temperature effect ±0.1% of reading 20 ms max response time to step change in input ±0.1% of rate over six months ±0.25% change over operating temperature range Wall mount transmitter physical specifications Materials of construction Standard housing Paint Optional housing Cover gaskets Low copper aluminum Type 4X and IEC 60529 IP66 Polyurethane coat (1.8 to 2.2 mils thick) Not available Silicone (6) For sensor sizes greater than 12 in. (300 mm) the high accuracy is ±0.25% of rate from 3 to 39 ft/sec (1 to 12 m/sec). 26 www.rosemount.com

Electrical connections Conduit entries ½ inch NPT or M20 Terminal block screws 6-32 (No. 6) suitable for up to 14 AWG wire Safety grounding screws External stainless assembly, M5; internal 8-32 (No. 8) Vibration rating 2G per IEC 61298 Dimensions See Dimensional drawings. Weight Wall mount transmitter Aluminum Approximately 9 lbs. (4 kg) Add 1 pound (0.5 kg) for local operator interface. Field mount transmitter physical specifications Materials of construction Standard housing Paint Optional housing Cover gasket Low copper aluminum Type 4X and IEC 60529 IP66 Polyurethane coat (1.8 to 2.2 mils thick) 316/316L unpainted, option code SH Type 4X and IEC 60529 IP66 Aluminum housing: Buna-N Electrical connections Conduit entries Available in 1/2 inch NPT or M20. See ordering table footnotes for details Terminal block screws 6-32 (No. 6) suitable for up to 14 AWG wire Safety grounding screws External stainless assembly, M5; internal 8-32 (No. 8) Vibration rating Integral mount 2G per IEC 61298 Remote mount 5G per IEC 61298 Dimensions See Dimensional drawings. Weight Field mount transmitter only Aluminum Approximately 7 lbs. (3.2 kg) www.rosemount.com 27

316 stainless steel Approximately 23 lbs. (10.5 kg) Add 1 pound (0.5 kg) for local operator interface. Sensor specifications Functional specifications Service Conductive liquids and slurries Line sizes ½ in. to 48-in. (15 mm to 1200 mm) Sensor coil resistance 7-16 Ω Interchangeability System accuracy is maintained regardless of line size or optional features. Each sensor nameplate has a sixteen-digit calibration number that can be entered into a transmitter through the Local Operator Interface (LOI) or the Field Communicator. Upper range limit 39.37 ft/s (12 m/s) Ambient temperature limits 20 to 140 F ( 29 to 60 C) standard design Pressure limits See Process temperature limits. Vacuum limits PTFE lining All other standard sensor lining materials Full vacuum to 350 F (177 C) through 4-in. (100 mm) line sizes. Consult Technical Support for vacuum applications with line sizes of 6 inches (150 mm) or larger Full vacuum to maximum material temperature limits for all available line sizes. 28 www.rosemount.com

Submergence protection IP68 The remote mount sensor is rated IP68 for submergence to a depth of 33 ft (10 m) for a period of 48 hours. IP68 rating requires that the transmitter must be remote mount. Installer must use IP68 approved cable glands, conduit connections, and/or conduit plugs. For more details on proper installation techniques for IP68, reference Rosemount Technical Note 00840-0100-4750 available on www.rosemount.com. Conductivity limits Process liquid must have a minimum conductivity of 5 microsiemens/cm (5 micromhos/cm) or greater. Process temperature limits PTFE lining Polyurethane lining Neoprene lining 58 to 350 F ( 50 to 177 C) 0 to 140 F ( 18 to 60 C) 0 to 176 F ( 18 to 80 C) Table 42: Temperature vs. Pressure Limits for ASME B16.5 class flanges (1) Sensor temperature vs. pressure limits for ASME B16.5 class flanges ( ½ -in. to 24-in. Line Sizes) (2) Pressure Flange material Flange rating @ -20 to 100 F (-29 to 38 C) @ 200 F (93 C) @ 300 F (149 C) @ 350 F (177 C) Carbon Steel Class 150 285 psi 260 psi 230 psi 215 psi Class 300 740 psi 675 psi 655 psi 645 psi 304 Stainless Steel Class 150 275 psi 235 psi 205 psi 190 psi Class 300 720 psi 600 psi 530 psi 500 psi (1) Liner temperature limits must also be considered. (2) 30-in. and 36-in. AWWA C207 Class D rated to 150 psi at atmospheric temperature. Table 43: Temperature vs. Pressure Limits for AS2129 Table D and E flanges (1) Sensor temperature vs. pressure limits for AS2129 Table D and E flanges (4-in. to 24-in. line sizes) Pressure Flange Material Flange Rating @ -29 to 50 C (-20 to 122 F) @ 100 C (212 F) @ 150 C (302 F) @ 200 C (392 F) Carbon Steel D 101.6 psi 101.6 psi 101.6 psi 94.3 psi E 203.1 psi 203.1 psi 203.1 psi 188.6 psi (1) Liner temperature limits must also be considered. Table 44: Temperature vs. Pressure Limits for EN 1092-1 flanges (1) Sensor temperature vs. pressure limits for EN 1092-1 flanges (15 mm to 600 mm Line Sizes) Pressure Flange material Flange rating @ -29 to 50 C (-20 to 122 F) @ 100 C (212 F) @ 150 C (302 F) @ 175 C (347 F) Carbon Steel PN 10 10 bar 10 bar 9.7 bar 9.5 bar www.rosemount.com 29

Table 44: Temperature vs. Pressure Limits for EN 1092-1 flanges (1) (continued) Sensor temperature vs. pressure limits for EN 1092-1 flanges (15 mm to 600 mm Line Sizes) Flange material Flange rating Pressure @ -29 to 50 C (-20 to 122 F) @ 100 C (212 F) @ 150 C (302 F) @ 175 C (347 F) PN 16 16 bar 16 bar 15.6 bar 15.3 bar PN 40 40 bar 40 bar 39.1 bar 38.5 bar 304 Stainless Steel PN 10 9.1 bar 7.5 bar 6.8 bar 6.5 bar PN 16 14.7 bar 12.1 bar 11.0 bar 10.6 bar PN 40 36.8 bar 30.3 bar 27.5 bar 26.5 bar (1) Liner temperature limits must also be considered. Table 45: Temperature vs. Pressure Limits for GB/T 9119 Flanges (1) Temperature vs. Pressure Limits for GB/T 9119 Flanges Pressure (Mpa) Flange material Flange rating 20 C @ 100 C (212 F) @ 150 C (302 F) Carbon steel Group 3E0 PN 10 1.00 0.92 0.88 PN 16 1.60 1.48 1.40 PN 40 4.00 3.71 3.52 304 SST Group 11E0 PN 10 1.00 0.90 0.81 PN 16 1.60 1.45 1.31 PN 40 4.00 3.63 3.27 (1) Liner temperature limits must also be considered. Table 46: Temperature vs. Pressure Limits for JIS B2220 Flanges (1) Temperature vs. Pressure Limits for JIS B2220 Flanges Flange material Flange rating Pressure (Mpa) 50 C (122 F) Carbon steel 10K 1.4 1.4 304 stainless steel (15 mm to 65 mm) 10K 1.4 1.4 304 stainless steel ( 80 mm) 10K 1.4 1.4 @ 120 C (248 F) (1) Liner temperature limits must also be considered. Physical specifications Non-wetted materials Sensor Pipe Type 304/304L SST 30 www.rosemount.com

Flanges Coil housing Paint Carbon steel, Type 304/304L SST Rolled carbon steel Polyurethane coat (2.6 mils or greater) Process-wetted materials Lining PTFE, Polyurethane, Neoprene Electrodes 316L SST, Nickel Alloy 276 (UNS N10276) Flat-faced flanges Flat-faced flanges are manufactured with full-face liners. Available in Neoprene only. Process connections ASME B16.5 AWWA C207 EN 1092-1 AS2129 AS4087 GB/T9119 JIS B2220 Class 150: ½ -in. to 24-in. (15 mm to 600 mm) Class 300: ½ -in. to 24-in. (15 mm to 600 mm) Class D: 30-in. to 48-in. (750 mm to 1200 mm) Class E: 30-in. to 48-in. (750 mm to 1200 mm) PN10: 200 mm to 900 mm (8-in. to 36-in.) PN16: 50 mm to 900 mm (2 -in. to 36-in.) PN40: 15 mm to 900 mm (½-in. to 36-in.) Table D and Table E: 15 mm to 900 mm (½-in. to 36-in.) PN16, PN21: 2-in. to 40-in., 48-in. (8-in. excluded) (50 mm to 1000 mm, 1200 mm) PN35: 2-in. to 36-in. (8-in. excluded) (50 mm to 900 mm) PN10: 8- and 24-, 36-, 40-, 48-in. (200 mm to 600 mm, 900 mm, 1000 mm, 1200 mm) PN16: 4- and 24-, 36-, 40-in. (100 mm to 600 mm, 900 mm, 1000 mm) PN40: ½- to 24-in. (15 mm to 600 mm) 10K, 20K: ½- to 24-in. (15 mm to 600 mm) Electrical connections Conduit entries Available with 1/2 inch NPT and M20 Terminal block screws 6-32 (No. 6) suitable for up to 14 AWG wire Safety grounding screws External stainless assembly, M5; internal 8-32 (No. 8) Process reference electrode (optional) A process reference electrode can be installed similarly to the measurement electrodes through the sensor lining. It will be made of the same material as the measurement electrodes. Grounding rings (optional) Grounding rings can be installed between the flange and the sensor face on both ends of the sensor. Single ground rings can be installed on either end of the sensor. They have an I.D. slightly larger than the sensor I.D. and an external tab to attach ground wiring. Grounding rings are available in 316L SST, and Nickel Alloy 276 (UNS N10276). Dimensions See Dimensional drawings. www.rosemount.com 31

Weight See Table 47 through Table 54. Product Certifications For detailed approval certification information and installation drawings, please see the appropriate document listed below: Document number 00825-MA00-0004: Rosemount 8750W Approval Document - IECEx and ATEX Document number 00825-MA00-0005: Rosemount 8750W Approval Document Class Division Document number 00825-MA00-0006: Rosemount 8750W Approval Document North America Zone Dimensional drawings Figure 6: Remote field mount transmitter 7.49 (189,8) 6.48 (164,6) 5.77 (146,4) 1.94 (49,3) A B 10.29 (261,3) 5.00 (127,0) 2.81 (71,4) 3.00 (76,2) 2.22 (56,4) 3.07 (78,0) D 8.86 (225,1) 7.64 (194,0) C 5.00 (127,0) 1.80 (45,7) A 10.18 (258,6) A. ½-in. 14 NPT or M20 conduit entry B. LOI cover C. 2-in. pipe bracket D. Ground lug Figure 7: Integral field mount transmitter 5.82 (147,8) 32 www.rosemount.com

Figure 8: Wall mount transmitter with standard cover 4.31 (109) 9.01 (229) 2.81 (71) 3.11 (79) 0.44 12.02 (305) 11.15 (283) A B 2.96 (75) A. Ground lug B. ½-in. 14 NPT conduit connection (four places) Figure 9: Wall mount transmitter with LOI cover A Figure 10: Raised face flanged sensor ½ - to 2½ -in. (15 mm to 65 mm) 4.00 (101,6) (50,8).90 (22,9) 3.26 (82,8) 5.00 (127) F F Flange bolts to straddle center line www.rosemount.com 33

Table 47: Raised face flanged sensor ½ - to 2½ -in. (15 mm to 65 mm) dimensions Overall length Size, description PTFE Neoprene Poly Dim B Dim C Dim D Dim J Flow tube wgt (lbs./ kg ) 0.5-in. (15 mm) ASME - 150, 3.50 (89) 4.50 (114) 4.41 (112) 1.38 (35) 9 (4) 0.5-in. (15 mm) ASME - 300, 3.74 (95) 4.50 (114) 4.41 (112) 1.38 (35) 10 (5) 0.5-in. (15 mm) EN 1092-1 - PN40, 3.74 (95) 4.50 (114) 4.41 (112) 1.77 (45) 10 (5) 0.5-in. (15 mm) AS 2129 table D, 3.74 (95) 4.50 (114) 4.41 (112) 1.85 (47) 8 (4) 0.5-in. (15 mm) AS 2129 table E, 3.74 (95) 4.50 (114) 4.41 (112) 1.85 (47) 8 (4) 0.5-in. (15 mm) JIS B2220-10K, 3.74 (95) 4.50 (114) 4.41 (112) 1.77 (45) 10 (5) 0.5-in. (15 mm) JIS B2220-20K, 3.74 (95) 4.50 (114) 4.41 (112) 1.77 (45) 10 (5) 0.5-in. (15 mm) GB/T9119 PN40, 3.74 (95) 4.50 (114) 4.41 (112) 1.77 (45) 10 (5) 1-in. (25 mm) ASME - 150, 4.25 (108) 4.50 (114) 4.41 (112) 11 (5) 1-in. (25 mm) ASME - 300, 4.88 (124) 4.50 (114) 4.41 (112) 14 (6) 1-in. (25 mm) EN 1092-1 - PN40, 4.53 (115) 4.50 (114) 4.41 (112) 2.68 (68) 14 (6) 1-in. (25 mm) AS 2129 table D, 4.53 (115) 4.50 (114) 4.41 (112) 2.56 (65) 10 (5) 1-in. (25 mm) AS 2129 table E, 4.53 (115) 4.50 (114) 4.41 (112) 2.48 (63) 10 (5) 1 -in. (25mm) JISB2220-10K, 4.92 (125) 4.50 (114) 4.41 (112) 2.64 (67) 13 (6) 1-in. (25 mm) JIS B2220-20K, 4.92 (125) 4.50 (114) 4.41 (112) 2.64 (67) 14 (6) 1-in. (25 mm) GB/T9119 PN40, 4.53 (115) 4.50 (114) 4.41 (112) 2.68 (68) 14 (6) 1.5-in (40 mm) ASME - 150, 7.80 (198) 5.00 (127) 5.21 (132) 4.82 2.88 (73) 15 (7) 1.5-in. (40 mm) ASME - 300, 7.80 (198) 6.12 (155) 5.21 (132) 4.82 2.88 (73) 21 (9) 1.5-in. (40 mm) EN 1092-1 - PN40, 7.80 (198) 5.91 (150) 5.21 (132) 4.82 3.46 (88) 19 (9) 1.5-in. (40 mm) AS 2129 table D, 7.80 (198) 5.31 (135) 5.21 (132) 4.82 3.07 (78) 12 (6) 1.5-in. (40 mm) AS 2129 table E, 7.80 (198) 5.31 (135) 5.21 (132) 4.82 3.07 (78) 13 (6) 1.5-in. (40 mm) JIS B2220-10K, 7.80 (198) 5.51 (140) 5.21 (132) 4.82 3.19 (81) 16 (7) 34 www.rosemount.com

Table 47: Raised face flanged sensor ½ - to 2½ -in. (15 mm to 65 mm) dimensions (continued) Overall length Size, description 1.5-in. (40 mm) JIS B2220-20K, 1.5-in. (40 mm) GB/T9119 PN40, PTFE 2-in. (50 mm) ASME - 150, 2-in. (50 mm) ASME - 300, 2-in. (50 mm) EN 1092-1 - PN40, 2-in. (50 mm) AS 2129 table D, 2-in. (50 mm) AS 2129 table E, 2-in. (50 mm) JIS B2220-10K, 2-in. (50 mm) JIS B2220-20K, 2-in. (50 mm) AS 4087 PN16, 2-in. (50 mm) AS 4087 PN21, 2-in. (50 mm) AS 4087 PN35, 2-in. (50 mm) GB/T9119 PN40, 2.5-in. (65 mm) ASME - 150, 2.5-in. (65 mm) ASME - 300, 2.5-in. (65 mm) EN 1092-1 - PN16, 2.5-in. (65 mm) EN 1092-1 - PN40, 2.5-in. (65 mm) AS 2129 table D, 2.5-in. (65 mm) AS 2129 table E, 2.5-in. (65 mm) JIS B2220-10K, 2.5-in. (65 mm) JIS B2220-20K, 2.5-in. (65 mm) AS 4087 PN16, 7.82 (199) 7.82 (199) 7.82 (199) 7.82 (199) 7.82 (199) 7.82 (199) 7.82 (199) 7.82 (199) 7.82 (199) Neoprene 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.80 (198) 7.76 (197) 7.76 (197) 7.76 (197) 7.76 (197) 7.76 (197) 7.76 (197) 7.76 (197) 7.76 (197) 7.76 (197) Poly Dim B Dim C Dim D Dim J 5.51 (140) 5.91 (150) 6.00 (152) 6.50 (165) 6.50 (165) 5.91 (150) 5.91 (150) 6.10 (155) 6.10 (155) 5.91 (150) 6.50 (165) 6.50 (165) 6.50 (165) N/A 7.00 (178) N/A 7.50 (191) N/A 7.28 (185) N/A 7.28 (185) N/A 6.50 (165) N/A 6.50 (165) N/A 6.89 (175) N/A 6.89 (175) N/A 6.50 (165) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 5.21 (132) 6.31 (160) 6.31 (160) 6.31 (160) 6.31 (160) 6.31 (160) 6.31 (160) 6.31 (160) 6.31 (160) 6.31 (160) 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 4.82 5.37 (136) 5.37 (136) 5.37 (136) 5.37 (136) 5.37 (136) 5.37 (136) 5.37 (136) 5.37 (136) 5.37 (136) Flow tube wgt (lbs./ kg ) 3.19 (81) 17 (8) 3.46 (88) 19 (9) 3.62 (92) 20 (9) 3.62 (92) 23 (11) 4.02 (102) 24 (11) 3.54 (90) 14 (6) 3.54 (90) 15 (7) 3.78 (96) 18 (8) 3.78 (96) 19 (9) 3.54 (90) 16 (7) 4.06 (103) 4.06 (103) 4.02 (102) 4.12 (105) 4.12 (105) 4.80 4.80 4.06 (103) 4.06 (103) 4.57 (116) 4.57 (116) 4.06 (103) 34 (16) 96 (44) 23 (11) 27 (12) 32 (15) 27 (12) 31 (14) 17 (8) 19 (9) 25 (11) 26 (12) 18 (8) www.rosemount.com 35