Xiangping Wang,PGGI, ABB Engineering (Shanghai) Co. Ltd.,Nov ABB 1000kV Grid Integration AIS Solution in PP. ABB November 16, 2016 Slide 1

Similar documents
MOBILE SUBSTATION GUIDE

Raising the bar. UHV switchgear and components

High Voltage Surge Arresters Buyer s Guide Section Line Surge Arrester PEXLINK

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

Compact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS)

B kv T&D GAS INSULATED SWITCHGEAR

ABB Wind Power Solution

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SPEN, Rasmus Larsson, High Voltage Breakers Innovative breaker solutions Substation design

Small wonder. Station service voltage transformers for small power requirements

BROCHURE. End-to-end microgrid solutions From consulting and advisory services to design and implementation

132/11 kv, 25 MVA MOBILE SUBSTATION

Overview Overvoltage protection

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

15 Nelson-Marlborough Regional Plan

Substation Concepts for the Future

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

SF6 free high-voltage GIS installation in Zürich, CH.

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

15 Nelson-Marlborough Regional Plan

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Renewable and Distributed Energy Resource Technologies

ABB POWER SYSTEMS CONSULTING

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

EE 741 Over-voltage and Overcurrent. Spring 2014

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Minnesota Power Systems Conference Insulation Coordination Tutorial November 6, 2014

Next Generation of UHVDC System. R. Montaño, D Wu, L. Arevalo, B. Jacobson ABB - HVDC Sweden

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

MINISOLA, PGHV ITABB ABB Power Products High Voltage Italy

ABB s High Voltage Products Business overview - Legacy of over 100 years. ABB Group June 5, 2015 Slide 17

HIS Highly Integrated Switchgear up to 550 kv, 63 ka, 5000 A Type 8DQ1

Gas Insulated Substation Testing and Application

ABB Wind Care Service Offering

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

INNOVATIVE SUBSTATION SOLUTIONS TO REDUCE INVESTMENT COSTS - IMPROVED AVAILABILITY AND RELIABILITY

Fault management for grid automation Advanced fault location solution

A 500kV AIS Switchyard Rejuvenation in British Columbia using Hybrids

Cigre SC B4 Activities Towards HVDC Grids. HVDC Grid Workshop Belgium

Microgrid solutions Delivering resilient power anywhere at any time

Pankaj Khali, ABB India Limited Representing :ABB Switzerland limited, September 2016 Generator Circuit-Breakers. Technical Seminar: PLN

Innovative technologies ready for the Supergrid

Application and Prospect of Smart Grid in China

Retrofit for GIS. Service High Voltage Products, Transmission GIS, January Overview

OBJECTIVES LCC HVDC SYSTEMS VSC HVDC SYSTEMS COMMON EQUIPMENT DIFFERENT OPTIONS ECONOMIC IMPACTS CONCLUSIONS

3AP1 DTC for 145 and 245 kv

B kv Gas-insulated Substations

Protection with distributed generation, experience with the Mont-Soleil wind farm project

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

III. Substation Bus Configurations & Substation Design Recommendations

Stefano Cervidi - ABB S.p.A. PPHV Santiago de Chile J.T. ABB Chile de Abril 2015 PASS - Plug and Switch System Subestaciones con tecnologìa

When power interruptions happen.

Seabrook Substation Reliability Improvement Project

CPG.0 Single busbar gas-insulated cubicles

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Age-dependent & multi-load reliability analysis in transmission systems

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Service and Rehabilitation Electrical Power Systems

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

Gas Insulated Metal-clad Switchgear, HMGS!

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

The Energy Queensland Group Notice of no non-network options

Use of High-Power Thyristor Technology for Short-Circuit Current Limitation in High Voltage Systems

Power Products Division. Power Services Service underpins everything we do

Generation Interconnection Facilities Study For

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Enabling the power of wind. Competence and expertise for wind power customers

Electric Utility Power Systems. Generation of Electricity

Mikael Dahlgren, ABB Corporate Research, 02 December 2011 ABB Technology providers perspective Energidagen Chalmers Energyinitiative

The substation. Olof Samuelsson

PPL Gas Insulated Substations: Design Considerations and Lessons Learned. Nicholas Matone Support Engineer, T&S Standards

ABB Next Level Big shift in power attractive opportunities

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

REQUEST FOR PROPOSALS FOR THE ESTABLISHMENT OF SOLAR PV POWER PLANT ON BUILD, OWN AND OPERATE BASIS. International Competitive Bidding (ICB)

CHAPTER 4 SUBSTATION CONFIGURATION RELIABILITY ESTIMATION BY SUCCESSFUL PATH METHOD

IEEE PES Panel Discussion

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

PRAGATI ENGINEERING COLLEGE

Transmission and Distribution Substation Projects. Operating Company: Entergy Gulf States - Texas. Customer: PID # 202

Fundamentals of Modern Electrical Substations Part 3: Electrical Substation Engineering Aspects

2015 WDC Disturbance and Protection Standards Overview

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A

Flanders Electric Engineering Division

Substation Committee K2 TF1 of the GIS Subcommittee GIS/GIL/SF 6 -Tutorials

ABB solar inverters Product portfolio

Product overview. ABB High Voltage Products Surge arresters

ABB November 7, Slide 1

GROUP D. Switch & Protective device.

The Deutsche Akkreditierungsstelle GmbH attests that the testing laboratory

WESTERN INTERCONNECTION TRANSMISSION TECHNOLGOY FORUM

David Park, EPMV ABB South Africa / Africa Channel Partner event, 2016 ABB Africa Channel Partner event Medium Voltage Apparatus

Washington, DC Area Low Voltage Disturbance

Breaking news. Ultra-high-voltage switchgear to power China Walter Holaus, Fredi Stucki. Product innovations

ABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition

Unified requirements for systems with voltages above 1 kv up to 15 kv

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

Transcription:

Xiangping Wang,PGGI, ABB Engineering (Shanghai) Co. Ltd.,Nov. 2016 ABB 1000kV Grid Integration AIS Solution in PP Slide 1

ABB 1000kV Grid Integration AIS Solution in PP 1000kV Grid Plan Demand and advantage of EHV grid Demand and advantage of EHV grid integration in PP Advantage of EHV integration AIS solution in PP Relevant EHV specification ABB step-up substation scheme in PP EHV Switchgears Single-line diagram types for 1000kV step-up substation Highlights of the scheme Roadmap of ABB 1000kV grid integration AIS solution in PP Slide 2

1000kV Grid Plan National EHV grid development during period of 12.5 (3 vertical & 3 horizontal) 3 Vertical Ximeng~Beijing (E)~Tianjin(S)~Jinan~Xuzhou~Nanjing Zhangbei~Beijing(W)~Shijiazhuang~Henan(N)~ Zhumadian~Wuhan~Nanchang Neimeng(W)~Sanxi(M)~Sanxi(ES)~Nanyang~Jingmen~ Changsha 3 horizontal Shanxi(N)~Sanxi(N)~ Shijiazhuang ~ Jinan ~Weifang Jingbian~ Sanxi(B) ~ Henan(N) ~Xuzhou~Lianyungang Yaan~Leshan~Chongqin~Changshou~Wanxian~ Jingmen ~ Wuhan ~Anhui(S)~Zhejiang(N)~Shanghai Slide 3

1000kV Grid Plan 1000kV Slide 4

Demand and advantage of EHV grid Transmission over long distance Reduce land occupation of corridor Enhance interconnection of national grid Strengthen security & stability of grid operation Improve the structure of grid Enlarge integration of remote area renewables Reduce PM2.5 emission 1200 U [kv] 1000 Optimum Voltage level for energy transmission 800 600 2000 km 200 km 400 200 0 Slide 5 P [MW 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Data from A. Clerici, ABB Italy. Single transmission line circuit(200/2000km distance) Transmission Power vs Optimum Voltage Requirement of transmission line corridor (5000MW)

Demand and advantage of EHV grid integration in PP No line corridor or no spare bay at opposite substation(500kv grid integration) 1000MW generator units being pushed forward 1000kV EHV grid integration by National policy Reduce intermediate step-up process, shorten electrical distance, and save land resource and project investment by adopting EHV grid integration Upgrading power transmission capability and efficiency of a channel unit and improving benefit from PP and grid performance when EHV concentration output exploited at large scale energy base Slide 6

Advantage of EHV integration AIS solution in PP Cost of construction moderate and cutting down the investment of early stage by AIS solution Lead time of equipment production is short than that of GIS Easily expandable, convenient maintenance and test Optimal tradeoff between land occupation and investment saving in case of the land of electric power station near coal-mines is relatively sufficient or loose Slide 7

Relevant EHV specification Q/GDW 1786-2013 Code for design of 1000kV substation Q/GDW 312-2009 Technical specification of Oil-immersed Transformer for 1000kV System GB 50697-2011 Code for design of 1000kV substation GBZ 24842-2009 Overvoltage and insulation coordination of 1000kV UHV AC transmission project GBZ 24838-2009 Specification for 1100 kv alternating-current high-voltage circuit-breakers GBZ 24837-2009 Specification for 1100 kv alternating-current disconnectors and earthing switches GBZ 24841-2009 Technical specification for capacitor voltage transformers of 1000kV AC system GBZ 24845-2009 Specification of metal-oxide surge arresters without gaps for 1000 kv AC system GBZ 24840-2009 Technical specification for bushing of 1000 kv AC system Slide 8

Relevant EHV specification Q/GDW 1786-2013 Code for design of 1000kV substation ------Main electrical circuit connection and 1000kV conductor Simplified connection scheme with less circuit breakers shall be used. Slide 9

Relevant EHV specification Recommended transitional type for 3/2 breakers main electrical circuit connection Slide 10

Relevant EHV specification Min. clearance for 1000kV outdoor switchgear installation Split conductor to ground Tubular conductor to ground Single tubular. Conductor to ground. Split OH Slide 11

Relevant EHV specification Overvoltage level and protection level for ZnO arrestor Power frequency OV of phase to earth S/S side for line circuit breaker line side for line circuit breaker Rated voltage Continuous operating voltage Slide 12

Relevant EHV specification TR, Reactor (CB,DS) BIL SIL AR IS,ES) Bushing TR, Reactor Switchgear longitudinally TR NP Slide 13 Insulation level rating for 1000kV equipment

Relevant EHV specification Circuit breaker and disconnector AIS was not preferred due to the overall consideration of manufacturing ability and safety operation, project schedule and land resource save,etc. Slide 14 Height of bus to ground,about 28m; Height to outgoing line to ground, about 38m. Distance of phase to phases: about 15m

Relevant EHV specification Bay width, 54m Bay width of 1000kV switchgear and VFTO of disconnector VFTO result from many times refraction & reflection inside GIS Slide 15

ABB step-up substation scheme in PP EHV Switchgears Single-line diagram types for 1000kV step-up substation (1) Expanded-unit scheme/2 generators & 1 line (2) Triangle scheme / 3 outgoings (3) One and half breaker scheme (2 diameters) / 3 outgoings (4) One and half breaker scheme (3 diameters) / 6 outgoings (5) One and half breaker scheme (4 diameters) / 6 outgoings (6) Hexagon scheme / 6 outgoings Slide 16

2x54m (108m) (1) Expanded-unit scheme/2 generators & 1 line #2 G-T #1 G-T Line Slide 17 2X52m (104m)

(1) Expanded-unit scheme/2 generators & 1 line Expanded line-transformer unit, two generators and one line; Two circuit breakers, save one breaker compared to triangle scheme; Similar to triangle scheme, power output from two generators by one line, but this connection is unsuitable to be retrofit to one and half breaker scheme at a later stage; Two generator units can be put in or out of service separately without mutual influence; It is suitable for no later extension project, while two generators can be built by stages; If a permanent fault occurs on line, two generators should be outage therefore and no power from PP can be output; For AIS plane layout, refer to the following: Slide 18

Slide 19

Slide 20

Slide 21

Slide 22

Slide 23

20m + 3x54m + 20m (202m) (2) Triangle scheme / 3 outgoings Slide 24 11m + 4X52m + 11m (230m)

(2) Triangle scheme / 3 outgoings Three circuit breakers,3 outgoings(line or generatortransformer unit); Similar to 1 1/2 breaker scheme, with high reliability and many performance cases; For example, it has been adopted in Pingwei PP and will be retrofit to 1 1/2 breaker scheme at a later stage with a bigger change; It is suitable for no later extension project the same as the initial scheme; Power output from two generators by one line If a permanent fault occurs on line, two generators should be outage therefore and no power from PP can be output; For AIS plane layout, refer to the following: Slide 25

Slide 26

Slide 27

Slide 28

Slide 29

Slide 30

Slide 31

Slide 32

Slide 33

20m + 3x54m + 20m (202m) (3) One and half breaker scheme (2 diameters) / 3 outgoings 11m + 6X52m + 11m (334m) Slide 34

(3) One and half breaker scheme (2 diameters) / 3 outgoings Five circuit breakers,3 outgoings(line or generator-transformer unit); With high reliability and many performance cases; Two more circuit breakers compared to triangle scheme; Flexible and convenient for extension at a later stage; It can be formed and transited from earlier triangle scheme; More easily and expediently expandable at a later stage for AIS solution; Power output from two generators by one line. If a permanent fault occurs on line, two generators should be outage therefore; It is widely used in 500kV step-up substation of PP (GIS, AIS solution); Slide 35

20m + 3x54m + 20m (202m) (4) One and half breaker scheme (3 diameters) / 6 outgoings 横向 11m + 4X52m +11m (230m) (80m) 11m + 4X52m +11m (230m) Slide 36

(4) One and half breaker scheme (3 diameters) / 6 outgoings Nine circuit breakers,6 outgoings(line or generator-transformer unit); With high reliability and many performance cases; Three more circuit breakers compared to Hexagon scheme; Power output from four generators by two lines. If a permanent fault occurs on line, the power from four generators can still be output; It is often used as the future scheme in planned 1000kV PP; It is widely used in 500kV step-up substation of PP (GIS, AIS solution) ; There is no performance case of transiting from earlier scheme up to now in 1000kV PP (perhaps lasting for 8 years in triangle scheme) ; Slide 37

20m + 3x54m + 20m (202m) (5) One and half breaker scheme (4 diameters) / 6 outgoings 11m + 5X52m + 11m (282m) 11m + 5X52m + 11m (282m) Slide 38

(5) One and half breaker scheme (4 diameters) / 6 outgoings Ten circuit breakers,6 outgoings(line or generator-transformer unit) With high reliability and many performance cases; Four more circuit breakers compared to Hexagon scheme; One more circuit breaker compared to same scheme with three diameters; There is less interface to earlier stage compared to three diameters because of an independent part consists of two diameters; Power output from four generators by two lines. If a permanent fault occurs on line, the power from four generators can still be output; It is widely used in 500kV step-up substation of PP (GIS, AIS solution); Slide 39

20m + 3x54m + 20m (202m) (6) Hexagon scheme / 6 outgoings 11m + 3X52m + 11m (178m) 11m + 3X52m + 11m (178m) Slide 40

(6) Hexagon scheme / 6 outgoings Six circuit breakers,6 outgoings(line or generator-transformer unit) It does not lead to one line or generator outage in case of one CB maintenance; Three circuit breakers less than the scheme with three diameters Power output from four generators by two lines. If a permanent fault occurs on line, the power from four generators can still be output; A fault in one bay (line/generator) circuit shall result from hexagon string opened, two more lines/generators outage will happen in case another fault furtherly occurs; It is suitable for PP constructed at one time with no further extension at a later stage; Slide 41

ABB step-up substation scheme in PP EHV Switchgears Highlights of the scheme The adopted steel structure layout is the same as the filter circuit in the EHV converter station; The design style is a kind of 1 1/2 breaker matrix scheme; Independent and very clear to single bay maintenance and test for AIS solution, and with less affected area; A hybrid GIS FES is adopted for the rapid ES on the line side; It is irrespective of VFTO, because there is no reflection problem of transient wave for AIS solution; Insulation level under the pollution class of corresponding environment has been taken into account for AIS solution (IV Class); It is necessary for PP to benefit from appropriate connection scheme and land occupation; Reduce construction cost of equipment in step-up substation. Slide 42

Roadmap of ABB 1000kV grid integration AIS solution in PP Advantage of HPL CB; Big cost difference ABB EHV AIS solution in PP Acknowledge d By Customer Power DI participation SGCC expert group approval Introduction to step-up station EHV AIS solution in PP by ABB team roadmap Detailed feasibility design solution provided by DI and approved by SGCC expert group PG BD in charge of integrating all PG resource Slide 43