PSM72H Push-Button Start Module

Similar documents
EPM72 Engine Protection Module

SDM72 Start on Demand Modules

REVISED ATM72 Auto Transfer Module

BVF300 'Special' Battery Voltage Monitor

SUM340 SUMMATION BOARD

DEEP SEA ELECTRONICS PLC

1. AC VOLTS: Displays generator output in voltage. 2. AC FREQUENCY: Displays the speed of the generator set in Hertz.

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

DEEP SEA ELECTRONICS PLC

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

GCU-10. Automatic Engine Control Unit Operators Manual

DKG-114 MANUAL AND REMOTE START UNIT

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

DEEP SEA ELECTRONICS PLC

ANALOG CONTROL PANEL

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

GL1200T Cut & Seal. (GL1200 Seal only)

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

GENSET CONTROL MODULE LEVEL 1 A121CM / A241CM. Special logic to re-establish cranking following a false start.

AUTOSTART 705S V1.00 AUTOSTART 710S / 720S / 730S V1.04 Programming Reference and Check Sheets

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Deep Sea Electronics Plc

GENSET CONTROL MODULE A121A / A241A

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

GL1200T Cut & Seal. (GL1200 Seal only)

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

DEEP SEA ELECTRONICS PLC

AA4006 Speed Sensitive Trip Unit. User Manual

DEEP SEA ELECTRONICS PLC

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

R & D SPECIALTIES ROTROL I USER'S MANUAL

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

N1387 Series Troubleshooting Guide for N Alternators

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

STANDARD OWNER S MANUAL

ES52. Auto Start Engine Controller. Full Version. Installation and User Manual for the ES52 Auto Start Engine Controller.

HGM6410/6420 AUTOMATIC GENERATOR MODULE WITH J1939 INTERFACE SOFTWARE MANUAL

500 Series Troubleshooting Guide for C520 Alternators

ENGINE PROTECTION BOARD PDM1

DSEULTRA DSE6000 Quick Start Guide Document Number

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

DKG-109J AUTOMATIC MAINS FAILURE UNIT

DKG-215 MANUAL AND REMOTE START UNIT

Energy Division

HGM6000K Series Automatic Generator Module OPERATING MANUAL Smartgen Electronic

Crompton Controls. This is. Installation and Maintenance Instructions. S10 & Smooth-BRAKE DC Injection Brake Modules. Tel: +44 (0)

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

DKG-509 AUTOMATIC MAINS FAILURE UNIT

ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc.

GSC300. Auto Start Engine Controller. Installation and User Manual for the GSC300 Auto Start Engine Controller. Full Version

60 Series Engine Controls

Manual and Remote Start Unit with Key Switch, 72x72 DIN Size

Application Engineering

DKG-317 MANUAL AND REMOTE START UNIT

AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

Flight Systems. Replacement for KASSEC DESCRIPTION

Invertek. Battery Management Control System DC-SW-140 & DC-SW-140C DC-SW-70 & DC-SW-70C USER MANUAL

Application Engineering

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

ICON 2 1. FEATURES AND CHARACTEIRICS

GSC300 Auto Start Engine Controller

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

EC200 ELECTRONIC CONTROL SYSTEM

HGM6400 Automatic Genset Controller (With J1939 Interface) USER MANUAL Smartgen Technology

GSC300 Auto Start Engine Controller

OPERATING INSTRUCTIONS MCP-MT1

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

R-200A Digital Controller TECHNICAL MANUAL. A new standard of reliability. This manual should remain with the unit.

Deep Sea Electronics Plc

PSU EN54-4 Power Supplies

NT-500 Technical Support Guide. For use by qualified company approved Technicians

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

Designed for ease of integration with automation systems

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

PowerView PV380-R2 Mechanical Configuration

DKG-109 AUTOMATIC MAINS FAILURE UNIT

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

Troubleshooting Guide

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Installation Instructions & Users Manual

Phoenix Inverter

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

HSC940 Genset Controller CONTENTS 1 OVERVIEW PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION KEY FUNCTIONS...

Generator Controller Manual

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Caterpillar 1500kW XQ1500

Transcription:

Capricorn Controls DA02PSM72H1-2 Data & Application Note Page 1 of 6 PSM72H Push-Button Start Module Genset Controls - Timers/Monitors/Trips - Battery Charging Spares & Accessories - Custom Products Ultra compact 72mmsq DIN standard case... just 90mm deep 4 to 40Vdc single range supply no drop-out on cranking Selectable - LOP or HET inputs, open or close to Ve on fault Hours Counter and Timed Preheat Protected Solid-state outputs to drive external power relays Incorporating IP67 Push Button switches for use in harsh enviroments, these short 72mmsq DIN sized Modules can be easily mounted into almost any control panel or switchbox for use with a wide range of engine driven equipment. Five High Intensity LED s indicate system status. From the top, the symbols represent: Unit Powered, Low Oil Pressure, Cooling Fault, Preheat and Charge Fail. RED Button GREEN Button Press momentarily to stop the engine and reset all Shutdowns (! LED not lit). Always ensure that the engine is stationary before restarting. Press momentarily to power the module (! LED lit), energising the fuel solenoid and activating the Preheat output (and LED) for the pre-set time. As soon as the Preheat LED has extinguished, Press and hold the GREEN button to crank the engine (the Starter output is inhibited out until the Preheat timer has elapsed). Release the Button to disengage the starter motor as soon as the engine fires. The hold off timer is now running. Alternatively, if the engine fails to start after approx. 8 sec s cranking, release the Button, wait 10 sec s and try again. If the engine fails to start after three attempts, press the RED button to power-down the module (! LED not lit) and consult the engine manufactures Handbook. Note: - If the engine is continuously cranked for more than 10 sec s the module will shutdown on over-crank, as indicated on the top LED. Note: During Preheat time and engine cranking, the protection hold-off timer is held at reset. If the engine is not cranked within approx. 18 sec (from the end of either the Preheat time or the previous cranking period) the hold-off timer will elapse and the module will shutdown on Low Oil Pressure. This module incorporates a safety circuit which inhibits the starter output if 1. Pulse output or Preheat are active 2. Low Oil Pressure is NOT sensed 3. The engine has shutdown on a Low Oil Pressure or Cooling Fault condition Assuming that the engine fires, the GREEN button is released to disengage the Starter, the engine runs up to normal speed and the protection hold-off timer is running. When the hold-off timer has elapsed, the Low Oil Pressure and Cooling Fault circuits are enabled. In the event of a shutdown, the appropriate fault Led is lit, the Fuel relay is locked out (stopping the engine) and the LOP & HET channels disabled (first-up interlock). Note: This module incorporates circuitry to guarantee correct operation while experiencing voltage dips during cranking - without the need for internal batteries. Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 272360 Fax: +44 (0) 1295 264766 E-mail: sales@ capricorn-controls.com

Page 2 of 6 Excitation (term.7) is connected to the IGN terminal on the Charging Alternator. This is only active while the Fuel Solenoid is energised Charge Failure (term.8) is connected to the WL terminal on the Charging Alternator. When the fuel solenoid is energised but the engine is stationary or cranking the WL terminal will be at a potential close to Battery negative and the Charge Failure LED will be lit. During this time, an excitation current via an internal 82 Ohm resistor, is applied to the WL terminal. As the engine runs up to speed, the potential at the WL terminal rises to a level close to Battery positive, reducing the excitation current to zero and extinguishing the Charge Failure LED. The excitation supply is switched off at the end of the hold-off time (typically 18 sec from crank-cut). Should the Charging Alternator fail, the potential at the WL terminal will fall towards zero and the Charge Failure LED will light. Preheat (term.9) is connected to an external slave relay that powers the engine heater (or Glow Plugs). Use an insulated Pot adjuster or miniature insulated screwdriver to carefully adjust this timer (1 22 sec.) at the rear of the module. Fuel Pulse (term.10) is connected (if required) to an external slave relay that powers the Fuel Solenoid Pull-In coil for approx. 1 second. DC Supply (term.4 & 6) should be connected directly to the battery with a suitable fuse in the +Ve line. E. & O. E. The Proven Solution to Power Controls DA02PSM72H1-2

Capricorn Controls DA02PSM72H1-1 Data & Application Note Page 3 of 6 Connections 1 2 3 4 5 6 7 8 9 10 DIP Switches 2 LOP : 1 HET : ON for Close to Ve on Fault (OFF) for Open from Ve on Fault PreHeat Time Always ensure that the correct wire sizes are used and that all terminals are correctly tightened. Terminal Description Type Connect To ------ 1 LOP Low Oil Pressure - Ve Input Low Oil Pressure switch 2 HET Cooling Fault - Ve Input High Engine Temp / Coolant Level, Switch 3 Starter Starter Motor control +Ve Output External 4 Batt+ Supply +Ve ------------- Battery positive 5 Fuel Fuel Solenoid control +Ve Output External 6 Batt - Common DC -Ve supply ------------- Battery negative 7 Exc Excitation +Ve Output IGN terminal on the Charging Alternator 8 C.F. Charge Failure (see text) Input / Output WL terminal on the Charging Alternator 9 Preheat Timed Preheat control +Ve Output External 10 Pulse 1sec Fuel Pull-In Pulse - Ve Output External NOTE : Fully protected and current limited, DC solid-state switches designed to control external slave relays The PSM72H is pin for pin compatible with the KSM72CYZH C indicates that Overspeed protection is NOT fitted Y indicates 1sec pulse output for Fuel Solenoid with separate pull-in coil Z indicates the timed Preheat output H indicates an 'LCD' Hours Counter is fitted behind the windowed front label. An 'hour glass' indicator flashes every 6 th second to indicate that counting is in progress (only while the fuel solenoid is energised). Data retention is in excess of 20 years. Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 272360 Fax: +44 (0) 1295 264766 E-mail: sales@ capricorn-controls.com

Page 4 of 6 Application Notes PSM72H Oil Press. 1 Low Oil Pressure Cooling Fault Cooling Fault 2 Batt -Ve Start + Batt.+ Fuel + 3 4 5 F1 See note BATT +Ve Batt.- 6 IGN Exc+ 7 WL Chg.Fail 8 Preheat Pulse 9 10 BATT -Ve Fuel + Term5 Notes 1. Oil Press. & Cooling Fault inputs are shown as close to ground on fault (see text). 2. Cooling Fault can be used to indicate High Engine Temperature & / or Low Coolant Level 3. Fuse F1 = 5A Anti-surge 4. For s see Spares & Accessories section of our latest Price List. 5. All s should have flywheel suppression diodes fitted, to comply with EMC regulations ( ) 6. Terminals 7, 9 & 10 need only be connected if required. 7. The starter output is inhibited unless Low Oil Pressure is sensed. This safety circuit helps prevent operating the starter on a running engine. E. & O. E. The Proven Solution to Power Controls DA02PSM72H1-2

Capricorn Controls DA02PSM72H1-1 Data & Application Note Page 5 of 6 FAULT FINDING ----- PSM72H BASED SYSTEMS Always check the obvious first i.e. : System correctly wired Preheat Timer correctly set DIP switches correctly selected All connections use suitably rated cables to comply with all appropriate regulations. All terminal screw connections are correctly tightened. Battery(s) charged, in good condition, clean & tight connections and of the correct voltage The Module MUST be fitted in a control panel with adequate protection from adverse Temperature, Moisture & Vibration WARNING - Connecting any terminals to an AC supply may permanently damage this module. Unit Dead Charge Fail led not lit, set will not start Check for battery supply on term.4(b+) and term.6(b-) of the PSM72H using a DC voltmeter Preheat not operating (a) Observe Preheat LED, if lit for minimal time adjust on rear of module. (b) Check connections to slave relay and from there to the engine heater Over-crank shutdown (a) Engine has been continuously cranked for 10 seconds. Low oil pressure shutdown (a) Faulty oil pressure switch, incorrect type or trip setting (b) Check user selectable Input phasing (Dipswitch-2 = ON for close to Ve on fault) (c) Green button only pressed once (for Power-up and Preheat), engine not cranked Cooling Fault (High engine temp.) shutdown (a) Faulty temperature switch, incorrect type or trip setting (b) Check user selectable Input phasing (Dipswitch-1 = ON for close to Ve on fault) Charging Alternator fails to excite (a) Exc+ (term.7) not connected to the IGN connection on the charging alternator (if required) (b) Charge Fail (term.8) not connected to the WL. connection on the charging alternator MOUNTING The module must be fitted into a suitable control panel that provides adequate protection from the extremes of : Temperature, Humidity & Vibration. If this control panel is set-mounted then suitable Anti-Vibration mounts MUST be used SPECIAL BUILDS PSM72CYZH / X0? These 'X' numbers, indicate non-standard product, which have been manufactured to suit specific customer s requirements. They do not appear in any catalogues and may only be available to the original customer. When reordering, please quote the full part number together with the 'Serial Number' of the original unit(s). CUSTOMISED PRODUCTS If you have a specific requirement that is not listed above; please contact our Sales Desk for a quotation. We can normally customise a standard product within a matter of days in order to provide a prototype (if not, production) unit. Designed & manufactured in England by Capricorn Controls Telephone: +44 (0) 1295 272360 Fax: +44 (0) 1295 264766 E-mail: sales@ capricorn-controls.com

Page 6 of 6 SPECIFICATION Supply 12/24V Single range supply, operating from 6V to 30VDC Drop out : < 4 VDC Absolute maximum input : 40VDC Preheat Single turn potentiometer at rear of module 1 22 seconds. Over-crank Added starter motor protection, will shutdown if engine is continuously cranked for 10 seconds. Fault Inputs Low Oil Pressure Close / open from Batt.-Ve on fault (user selectable) Cooling Fault Close / open from Batt.-Ve on fault (user selectable) Hold-Off Timer Fixed 18 sec, held reset during Preheat time and while engine is cranking Outputs FUEL (+) DC solid-state switch, 1A current limited and fully protected (high side driver) FUEL PULSE (-) DC solid-state switch, 1A current limited and fully protected (low side driver) START (+) DC solid-state switch, 1A current limited and fully protected (high side driver) PREHEAT (+) DC solid-state switch, 1A current limited and fully protected (high side driver) Push Buttons Sealed to IP67, mechanical life = 1,000,000 operations, electrical life > 500,000 operations General Construction Ambient temperature -10 0 C to +55 0 C Operating, -25 0 C to +70 0 C Storage Through panel fitting, 72mm sq. DIN standard case. Reversed screen-printed LEXAN (or similar) front panel. Printed Circuit Boards varnished as standard. Dimensions 72 72 90 Notes : 1/ Not to Scale 2/ Dimensions in mm 3/ Panel cut-out 68 x 68 mm For a spare or replacement, please quote the Serial Number of the original unit. CAPRICORN CONTROLS LIMITED INDUSTRIAL ELECTRONIC ENGINEERS SPECIALIST CONTROLS FOR ENGINE APPLICATIONS Thorpe Close, Banbury, Oxon., OX16 4SW. England Tel: +44 (0) 1295 272360 Fax: +44 (0) 1295 264766 E-mail: sales@capricorn-controls.com Web: www.capricorn-controls.com Keystart, Remote Start, Start-on-Demand, Mains Failure, Mutual Standby & Multi-set Controllers. Annunciators and Lamp Modules. Voltage, Current, Frequency, Speed, and Temperature Monitors. Timers. Transport Refrigeration Spares. Batteries, Battery Chargers and Power Supplies. Spares and Accessories. Customised Products and Bespoke Designs. E. & O. E. The Proven Solution to Power Controls DA02PSM72H1-2