CFSD Series. Product Description

Similar documents
SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

Motorized Fire Dampers

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

SMOKE DAMPER - CLASS F MODEL BMSD

Model FSD-212. Combination FIRE SMOKE DAMPERS

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model FSD-331 Combination Fire Smoke Dampers

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

LLOYD INDUSTRIES INC.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

FSD60/MFSD60 Multi-blade Fire Damper

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Fire, Smoke, and Combination Fire Smoke Dampers

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

series FSD-FLD Fire and smoke dampers UL Approval

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

ARROW UNITED INDUSTRIES

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2, FS2C2 Fire Damper Models: MD19, MD39, MA19, MA39

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

VCD-23 Low Leakage CONTROL DAMPER

VCD-23. Flange Options. Size Limitations

VCD-23. Low Leakage CONTROL DAMPER

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2 Fire Damper Models: MD19, MD39, MA19, MA39

INSTALLATION INSTRUCTIONS MODEL KFD-555

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

ARROW INDUSTRIAL PRODUCTS

Model VCD-20 3V CONTROL DAMPER

Fire Dampers Catalogue

Installation, Operation and Maintenance Manual

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

SD-1250 and SD-1600 Series Smoke Dampers

Part # Installation,Operation and Maintenance Instructions

MOTORIZED VOLUME DAMPER

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Installation, Operation and Maintenance Manual

MULTI-BLADE FIRE DAMPERS

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

Smoke Dampers. Installation Instructions

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

FDR - Fire Damper for Rectangular and Circular Ducts. Halton FDR. Fire Damper for Rectangular and Circular Ducts

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com

MODEL 151B FIRE DAMPER

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

BC 03. Fire Dampers FD-GB-30-AS LISTED

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

MULTI-BLADE FIRE DAMPERS

RECEIVING AND HANDLING INSTALLATION SUPPLEMENTS WARRANTY SAFETY WARNING:

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

Series HCD Airfoil Control Damper

BC Motorized Fire Smoke Dampers MSFD-GB-30C1-A MSFD-GB-30C1-A LISTED

Model VCD-43 Extruded Airfoil Blade Control Damper

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

ID-141x 12-Gauge Hat Channel Industrial Damper

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

BD-1600 Balancing/Zone Control Damper

A Complete Line of Quality Products for Marine Applications

Introduction to Johnson Controls Dampers

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Systemair Fire Dampers

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

7/S5 FIRE DAMPER FD40. v 2.9 (en)

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Fusible Link (replaceable) Horizontal Mount

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

Thermal Isolation. Break

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

When Time is Everything... We Manufacture in Days - Not Weeks!

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Transcription:

COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke and or fire in ventilation systems that is greatly contribute to the safety of life and property in the early stage of fire. It prevents the spread of fire and or smoke through ventilation ductworks or wall openings. These type dampers offer an effective fire or smoke barrier maintaining the integrity in a fire situation and it is combined with low leakage characteristic for smoke management. It is suitable for installation in sheet metal ductworks or in walls or ceiling slabs made from concrete, brick and lightweight partition walls. In today's life safety products markets, many building code require Fire dampers, Smoke dampers and Combination Fire & Smoke dampers to be inspected for proper operation. Usually Fire and Combination Fire & Smoke dampers are supplied with a fusible linkage that is a one time device and generally limited within a specified temperature rating (165 or 212 F). Once this link has meet the elevated temperature, it can no longer be used and must be replaced with an identical link for further operation. "SAFID" introducing "ERL" Thermoelectric Tripping Device (heat sensor) to replace the existing high torque spring / fusible link fire closure mechanism in all Combination Fire & Smoke dampers and blade type Fire dampers. The "ERL" is thermally responsive bimetal disc / sensor that open and close the electrical contacts at a specific factory calibrated temperature setting. The "ERL" is available in fixed temperature setting at 165 F (74 C) only. The "ERL" sensor is a manual reset type and can be reset after the temperature has cooled down below the sensor set point. This feature allow the ease of operating and resetting the damper in a matter of seconds without replacing the links. It is reusable / ressettable heat responsive device that can only be reset after a visual inspection of the damper. The "ERL" requires factory installation and wiring together with the qualified actuator to meet "UL" requirements. The "ERL" in combination with a qualified electric actuators provides controlled closure and eliminates the instantaneous damper closure associated with traditional fusible links that can damage the entire ductworks. The duct smoke detector can be wired in series with the "ERL" to close the damper during smoke control mode. Dampers which allow remote resetting of the damper from a remote location are dangerous. All damper moving parts must be inspected and cycled at every six months and in accordance with "NFPA90A & 92A" latest edition and local codes. 1

Types 1. Sleeve Type (Model: CFSD-40) 2. Circular Type (Model: CFSD-50) 3. Oval Type (Model: CFSD-60) 4. Factory Installed Sleeve (Model: CFSD-80) Standard Construction Finish Mill Galvanized 1.5mm thick (Ga.16) galvanized steel "Triple Vee" (3V) groove type Blades (standard). Frame 130 x 24.5 x 1.5mm thick (Ga.16) galvanized steel hat channel. Blade stop 1.5mm thick (Ga.16) galvanized steel sheet bend at 45º angle. Linkage Side linkage concealed in frame. (Standard) Bearings Sintered Bronze oilite type. Compression type stainless steel grade 304, 0.3mm thick fastened between Side Seal (Jamb Seal) case and blades by blade axles. Blade tip seal Blade tip seals are high temperature Charcoal Dense Silicone Rubber. Zinc plated mild steel 12mm Round across the blade length and 10 x 10mm Jack shaft square end x 25mm long to suit with the actuator. Minimum Size 200W x 150H mm. Single blade construction up to 250mm height. Maximum Size 914W x 914H mm - Single section Mounting Vertical Velocity 2400 FPM Thermoelectric Tripping Device (ERL) Model: BAE165 US Bimetallic manual reset type. 165 F (74 C) rated UL listed. Damper Actuators - With Spring Return a. Two Position (Open / Close) Type: 1. BELIMO Model: BF-ME (24-230VAC) 2. BELIMO Model: BF-S-ME (24-230VAC) with built-in Auxiliary Switch. For Belimo Actuator details see pages 126-127. 10

Dimensions 4 7 5 8 11 6 Sleeve Type Model: CFSD-40 1 3 10 2 9 4 1. Casing 2. Linkage bracket 3. Blade 4. Linkage bar 5. Bearings 6. Blade stop 7. Side seal 8. Blade tip seal 9. Lock washer and galvanized round washer 10. Kneelock 11. Jack shaft 1

Dimensions Circular Type Model: CFSD-50 5 Flat Oval Type Model: CFSD-60 10

6 Dimensions CFSD with factory installed Sleeve, ERL & Actuator Model: CFSD-80 1 2 3 4 10 11 12 5 6 13 7 14 15 8 9 1. Damper frame 2. Blade 3. Thermoelectric tripping device 4. Sleeve 5. Linkage Bracket 6. Lock washer and galvanized round washer 7. Kneelock 8. Linkage bar 9. Actuator 10. Bearing 11. Blade tip seal 12. Side seal 13. Jack shaft 14. Blade stop 15. Power supply 1

Dimensions CFSD with factory installed Sleeve, ERL & Actuator Model: CFSD-80 7 10

Dimensions Model: CFSD 8 Blades Profiles: Note: All blades are constructed from galvanized steel sheet gauge 16. 1

Dimensions Model: CFSD Linkage Assembly: 9 10

Installation Details 90 CFSD with Factory Installed Sleeve, ERL & Actuator (Typical Installation) Notes: 1. Airflow can be at opposite direction. 2. The actuator and ERL can be located in either side of the wall. 3. Refer to installation manual for further installation details. 1

Actuators 91 BELIMO Model: BF230-S-ME ERL Model: BAE165US Sequence of operation: Fire Mode: The ERL (Thermoelectric Tripping Device) resettable link has a thermal sensor switch that interrups the power supply to the fire & smoke control actuator as soon as the duct temperature exceeds 165ºF caused by a fire. When the power supply is interrupted, the energy stored in the spring of the fire & smoke damper actuator moves the damper back to its safe position. The damper can be open again by pressing the reset button on ERL after the temperature cooled down below 165ºF. Smoke Mode: When a signal detected through normally closed smoke detector (by others) connection, the power supply to the fire & smoke damper actuator will be interrupted. The energy stored in the damper actuator moves the damper back to its safe position and remain closed until the smoke signal close down. The system will reset after power is reapplied to the actuator and damper will open. By placing an optional control switch (by others) in the closed position can be close the damper if required at any time. Typical Wiring Diagrams 10

Order Details 92 Order Code: Variants Duct Size CFSD-40 = Sleeve Type CFSD-50 = Circular Spigot CFSD-60 = Oval Spigot CFSD-80 = Factory Installed Sleeve CFSD-40-100-3V-PB-R-A1-V1 / 500x500 Width x Height or Diameter All damper's spigot sizes (slip-in type) will be manufactured less than the duct size to fit inside the ductwork connections. Power Supply V1 = 24VAC Type V2 = 24VDC 100 = Galvanized Steel Construction V3 = 120VAC 110 = Stainless Steel (304) Construction V4 = 230VAC Actuator Type Of Blades A1 = BELIMO BF-ME 3V = V Groove Type A1S = BELIMO BF-S-ME Linkage PB = Side linkage Parallel Blade Operation Type of Sensor ERL = Thermoelectric Tripping Device, Model: BAE165 US External Controls R = Right hand (Standard Supply) L = Left hand 1

Specification Text Combination Fire/Smoke Dampers with the following specifications shall be used in heating, ventilating and air conditioning duct systems passing through masonry walls, gypsum fire resistive walls or partitions, floor slabs and for use in smoke control systems in accordance with Standard for Installation of Air Conditioning and Ventilating Systems, NFPA 90A. Combination Fire/Smoke Dampers shall be tested and classified by Underwritters Laboratories Inc. in accordance with the standards; UL555 Standard for Safety, Fire Dampers and UL55S Standard for Safety, Smoke Dampers. Combination Fire/Smoke Dampers shall have a fire resistant rating of 1 ½ hour and minimum air leakage Class II with elevated test temperature of 250 ºF. It shall be tested at 2400FPM air velocity at 4.5 in. W.G. static pressure to be rated at 2000FPM air velocity at 4 in. W.G. static pressure. It shall be fitted with BELIMO spring return actuator and thermoelectric tripping device (ERL) with temperature rating of 165 ºF (74 ºC). ERL shall cut-off power supply to actuator in case of fire that will activate the spring return to close the damper blades. Order Example SAFID Combination Fire/Smoke Damper, galvanized steel construction, 3V groove blade for parallel blades operation, 500mm width X 500mm height duct size and right hand side external controls. Damper with factory installed sleeve and 230 VAC BELIMO actuator with built-in auxiliary switch and with thermoelectric tripping device BAE165 US. Make : SAFID Type : CFSD-80-100-3V-PB-R-A1S-V4-ERL / 500x500 Qty. : 1 93 Damper blades shall be with external linkage and parallel action, Ga.16 galvanized steel with 3V groove type for longitudinal reinforcement. Blade's tip seal shall be Type: 60 Durometer Charcoal Dense Silicone, meets gasket requirements of UL555S. Blade's axle shall be 9.5 X 9.5mm square forced-fit to one stub shaft secured to blade with 4 pieces of bolt & nut, and with sintered bronze oilite axle bearing. Jamb seal/side seal shall be stainless steel to fill gap between blade's end and frame. Jackshaft shall be Ø12mm galvanized steel with a crank and kneelock secured to the linkage bracket. Damper frame shall be Ga.16 galvanized steel formed into hat channel shape. 10