Practical Steps in GC Troubleshooting

Similar documents
GC Best Practices & Troubleshooting. Group/Presentation Title Agilent Restricted Month ##, 200X

Typical Gas Chromatographic System

Method Development for Capillary GC Systems. Slide 1

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

GC Inlets. An Overview. Simon Jones GC Applications Engineer

Jaap de Zeeuw Restek Middelburg, The Netherlands. Copyrights: Restek Corporation

Fast GC. Dial for e-seminar Audio. Slide 4 SPEEDY GC

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Techniques for Making Your GC Analysis More Repeatable, Reproducible and Robust

MET-Biodiesel Capillary GC Columns

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Using the PSD for Backflushing on the Agilent 8890 GC System

Technical Procedure for Gas Chromatography (GC-FID)

Agilent Multimode Inlet for Gas Chromatography

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Techniques for Improving the Reproducibility of GC Analysis

Setting up SilFlow for BackFlush in your GC

ASTM D 6730 Detailed Hydrocarbon Analysis

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Choose for Your Instrument

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Installing the 6850 Direct Valve Column Connector Kit

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

Split and Splitless Injection in Capillary Gas Chromatography

Agilent Multimode Inlet

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

C2, C3, C4 Monomer Analysis

Proof of Long-Term, Leak-Free Performance for a Novel Self-tightening GC Column Nut

Analysis of Petroleum Fractions by ASTM D2887

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Application Note. Abstract. Authors. Environmental Analysis

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

Same Column and Gas Type Try Different/Faster Velocities. Same Column, Switch He to H2 Carrier Then Try Faster Velocities

CP-3800 GAS CHROMATOGRAPH

Your GC Analysis More. and Robust. Mark Sinnott. May 11, Agilent Restricted

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Determination of Free and Total Glycerin in B100 Biodiesel

Agilent G2855A Deans Switching System

Simple Heart Cutting with Deans. Capillary Flow Technolgy. Simon Jones Applications Engineer

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

Agilent 7890 Series Gas Chromatograph

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Detailed Hydrocarbon Analysis Featuring Rtx -1 PONA Columns

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

6890 Installing ¼ Glass Columns

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

Analysis of Glycerin and Glycerides in Biodiesel (B100) Using ASTM D6584 and EN Application. Author. Abstract. Introduction

The next level of True Blue Performance

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Application. Gas Chromatography June 1995

Optimized Method Development of Large Volume Injection for GC/MS/MS of Food Pesticides

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Application Note. Author. Introduction. Energy and Fuels

Beverage Grade Carbon Dioxide

Agilent and ASTM. Update on Recent Activities. Page 1

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

GC Analysis of PCBs in Fish Oil by Direct Injection Without Any Sample Cleanup. Philip L. Wylie, Ph.D. Sr. Applications Chemist Agilent Technologies

Choose for Your Instrument. GC Supplies - Agilent Instrument Quick Pick Guide

DANI Transformer Oil Gas Analyzer

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Nickel Catalyst Tube Accessory 19205A

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

Optimized Method for Analysis of Commercial and Prepared Biodiesel using UltraPerformance Convergence Chromatography (UPC 2 )

REFINED RESTEK. Detailed Hydrocarbon Analysis. innovative petrochemical solutions. Featuring Rtx -DHA Columns

Determination of Sudan Dyes I IV in Curry Paste

DETECTORS Photo Ionization Detector - PID. Overview

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Agilent 7693A Automated Liquid Sampler

Customer Information. Service Engineer s Responsibilities. Additional Instruction Notes GC Preventive Maintenance Checklist Standard

260 Solvent Vapor Exit Accessory

AZ Chrom s.r.o.

performance productivity reliability

Phenomenex Exclusive! Inlet Base Seals. Agilent 5000, 6000 and. Guaranteed fit for Series GCs. Easy Seals

2-D GC/MS and the Deans Switch: Theory and Applications. Fred Feyerherm, Agilent Technologies Inc. Houston, Tx

Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

6890 CHECKOUT PROCEDURE TCD (THERMAL CONDUCTIVITY) DETECTOR

Liquid Injection Techniques in GC and GC-MS

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

Microsep Low-Bleed PTFE-Lined Septa. XLB Septa

AppNote 6/2006. Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH) KEYWORDS

GC Method Compliance and Large Valve Oven Application

Restek Corporation 110 Benner Circle, Bellefonte, Pa Barry L. Burger, Neil Johansen, Valerie Gamble, Donald Rhoades

STI OPENING THE DOORS TO TEMPERATURE PROGRAMMING- A NEW FRONTIER IN HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Productivity Improvements for Dual Column Applications: USP <467> and Blood Alcohol Analysis

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

[ APPLICATION NOTE ] INTRODUCTION APPLICATION BENEFITS WATERS SOLUTIONS KEYWORDS

Transcription:

Practical Steps in GC Troubleshooting Techniques, Tips, and Tricks Mark Sinnott Application Engineer GC Columns & Supplies Page 1

Everything was just fine and then this happened! How do I go about TROUBLESHOOTING? Page 3

Everything was just fine and then this happened! Logic = Something changed (slowly or sudden) = Something is different Track Events log book -Changed column, liner, septum, syringe, etc. -Injected samples, other method, etc. -Did maintenance, cut column, inlet flush, etc. Page 4

Logical Troubleshooting Troubleshooting Starts with Isolating the problem There are 5 basic areas from where the problem arises INJECTOR FLOW COLUMN DETECTOR ELECTRONICS But of course it can always be some COMBINATION Knowing what can & can t cause the symptom is the key Page 5

Typical Problems of Optimized Methods becoming Unoptimized and the Reason Why. Peak Tailing Flow Path or Activity Bonus Peaks In Sample or Back Flash (Carry Over) Split Peaks Injector Problems, Mixed Solvent No Peaks Wasn t Introduced, Wasn t Detected Response Changes Activity, Injector Discrimination, Detector Problem Peak Fronting Overload or Solubility Mismatch, Injector Problems Shifting Retention Leaks, Column Aging, Contamination or Damage Loss of Resolution Separation Decreasing, Peak Broadening Baseline Disturbances Column Bleed, Contamination, Electronics Noisy or Spiking Baseline Electronics or Contaminated Detector Quantitation Problems Activity, Injector or Detector Problems Page 6

Peak Tailing INJECTOR or COLUMN is Active -Reversible adsorption of active compounds (-OH, -NH, -SH) FLOW problem - dead volume, obstruction, poor installation, or severe column contamination Miscellaneous - overloading of PLOT columns, co-elution, polarity mismatch between phase, solute or solvent, and some compounds always tail *Tip = Inject a light hydrocarbon, should not tail unless flow path problem. Page 7

Bonus Peaks W h = 0.106 Column: J&W P/N: 125-5032 Oven: DB-5 30 m x 0.53 mm I.D., 1.5 µm 60 C for 1 min 60-300 C at 20 /min 300 C for 3 min Carrier Gas: Helium at 36 cm/sec Injector: Split 1:100, 250 C sample C 7 - C 20 Detector: FID, 250 C W h = 0.029 Wh = 0.030 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 12.00 13.00 14.00 15.00 Page 8

Bonus Peaks or Ghost Peaks Contamination in INJECTOR, COLUMN or FLOW (carrier gas) -Carry-over from a backflash or previous sample -Bad tank of gas or traps have expired -Septum bleed *TIP = Run a blank run it should be blank! Page 9

Page 10 Bonus Siloxane Peaks

GC Column Bleed Ions Page 11

Column Bleed is Influenced by: 1.3e4 1.2e4 1.1e4 Phase type Temperature Column dimensions 1.0e4 9000 8000 DB-624 30M x.53mm I.D., 3.0µm 24 pa / 260 C 7000 6000 0 DB-1 30m x.32mm I.D.,.25µm 12 pa / 320 C 5 10 15 20 25 Time (min.)

Split Peaks INJECTOR (poor sample introduction) -Injecting the sample twice (some how?) -Mixed sample solvent (polarity difference) -Sample in syringe needle (manual inject) INJECTOR (activity) -Breakdown (not really a split peak, 2 peaks) -Sample degradation in injector VOLATILITY High boilers dropping out on Cold Spots -Transfer line temps -Unions or fittings not tracking column temp Page 13

No Peaks DETECTOR (not on or not operational) INJECTOR (not working) -Plugged syringe/plunger not moving -Wrong injector (or detector) -Huge leak (older systems) -No carrier gas flow NOT the COLUMN Unless -Broken column or No column Page 14

Peak Response All Change in Size INJECTOR -Leaky syringe -Split ratio set incorrectly -Wrong purge activation time -Septum purge flow too high -Injector temperature too low* DETECTOR (response problem) -Settings or flows changed -Electronics failing *Tip = Ask is it all of them or some of them, if all then injector or detector Page 15

Peak Response Some Change in Size INJECTOR or COLUMN is active/contaminated -Irreversible adsorption of active compounds (-OH, -NH, -SH) -Decomposition of sample -Temperature Change Discrimination -Evaporation from sample *Tip = If only some change, then ask which ones? If active compounds then activity. If tracks volatility then cold spots or inlet discrimination. Page 16

Peak Fronting Shark Fin Shaped or Just Slight COLUMN (contaminated) -Overload (More pronounced with large solute and phase polarity differences) INJECTOR -Column installation -Compound very soluble in injection solvent (need retention gap) -Mixed sample solvent OTHER -Co-elution -Breakdown Page 17

Retention Time Shift 1.75 2.00 3.25 4.75 INJECTOR -Leak in the septum -Change in injection solvent -Large change in sample concentration FLOW -Change in gas velocity COLUMN -Contamination -Damaged stationary phase -Loss of stationary phase -Change in temperature 4.50 3.00 2.75 5.50 4.00 Page 18

Effect of Sample Overload on Retention Time and Peak Shape 1400 ng 7 ng 8 9 10 11 min Page 19

Loss of Resolution Separation Peak Width Resolution is a function of separation and peak width Page 20

Loss of Resolution - Separation Decrease COLUMN -Different column temperature -Contamination (more phase?) Separation -Matrix components co-eluting -Different column phase? Peak Width Page 21

Loss of Resolution - Peak Broadening FLOW -Change in carrier gas velocity -Make-up gas Separation COLUMN -Contamination -Phase degradation Peak Width INJECTOR (efficiency) -Settings, Liner, Installation, etc. Page 22

Baseline Disturbances Sudden Changes, Wandering, or Drifting WANDER DRIFT COLUMN or DETECTOR -Not fully conditioned or stabilized (electronics) -Contamination FLOW -Changes in carrier and/or detector gas flows -Valves switching, leaks Page 23

Noisy Baseline MILD SEVERE FLOW -Contaminated gas -Incorrect detector settings COLUMN -Bleed if at high temperature -In detector flame (poor installation) DETECTOR -Air leak - ECD, TCD -Electronics malfunction Page 24

Spiking Baseline DETECTOR -Particles entering the detector -Random: poor connection -Regular: nearby "cycling" equipment (electronics) Page 25

Quantitation Problems DETECTOR -Poor stability (electronics) or Baseline disturbances (contamination) -Outside detector's linear range or wrong settings Activity (adsorption) in INJECTOR or COLUMN OTHER INJECTOR -Technique, settings, conditions -Syringe worn -Co-elution -Matrix effects -Sample evaporation leaky vials -Sample decomposition Page 26

What is NOT caused by a Column??? Peaks!! Any reproducible, sharp chromatographed peak! Siloxanes Degradation product peaks: Endrin Aldehyde, Endrin Ketone, DDE, DDD. Carryover of sample compounds Splitting of peaks Page 27

Troubleshooting Tools Bleed Profile: baseline problems Inject a non-retained peak: peak shape problems Test mix: all problems Isolate the components: all problems Condensation Test: baseline problems Jumper Tube Test: baseline problems Page 28

Generating a Bleed Profile 1.3e4 1.2e4 1.1e4 Produce when the column is new (for future reference) when there is a baseline problem 1.0e4 9000 8000 7000 6000 0 5 10 Time (min.) 15 20 25 *DB-1 30m x.32mm I.D.,.25µm Temperature program // 40 C, hold 1 min // 20 /min to 320 C, hold 10 min. Page 29

Non-Retained Peak Shapes Used to Check Flowpath Good Installation Improper Installation or Injector Leak Potential problems: Injector or septum leak Too low of a split ratio Liner problem (broken, leaking, misplaced) Column position in injector and detector Page 30

Test Mix Used to determine how good the column is or if the problem is related to the chemical properties of the analytes. Test Conditions Inlet: Split (250 C) Detector: FID (320 C) Carrier Gas: Hydrogen Flow: 37.3 cm/sec (1.8 ml/min) Holdup Compound: Methane (0.671-min) Temperature Program: Isothermal at 110 C Page 31

Test Mixture Components Compounds Hydrocarbons Alcohols FAME s, PAH s Acids Bases Purpose Efficiency Retention Activity Retention Acidic Character Basic Character Page 32

Own Test Mixture More specific to your application Selective detectors Concentrations specific to your application Use same instrument conditions Easiest to simply inject a calibration standard Store for future measure of column performance Group/Prese Page 33

Isolate the Components Simplify the system: - example - Direct injection instead of P&T sample introduction Put in a known good column Move column to a different GC, inlet or detector Page 34

Condensation Test Used* to isolate the cause of: - Erratic baselines - Ghost peaks or carryover *Use when problems are worse after periods of GC non-use Page 35

Condensation Test Procedure Leave GC at 40-50 C for > 8 hours Blank run Repeat a blank run immediately after the first blank run is complete Compare the two blank runs Page 36

Condensation Test Results First blank run is worse: - Contaminants (from injector, lines, traps or carrier gas) carried into the column Blank runs the same: contaminants are not strongly focused on the front of the column Page 37

Jumper Tube Test Purpose Helps to locate the source of contamination or noise Isolates GC components Page 38

Jumper Tube Test Isolate the Detector Remove column from the detector Cap detector and turn on Blank run Page 39

Jumper Tube Test Isolation of Detector - Results Detector OK Detector is the problem Page 40

Jumper Tube Test Isolate the Injector Connect the injector and detector - 1-2 meters deactivated fused silica tubing Turn on carrier gas Blank run Page 41

Jumper Tube Test Isolate the Injector - Results Injector OK Injector, lines or carrier gas contaminated Page 42

Jumper Tube Test Isolate the Column Reinstall the column Setup as before Blank Run Page 43

Jumper Tube Test Isolate the Column - Results Problem returns: It s the column Problem gone: Previous leak, solid debris, or installation problem Page 44

Page 45 And Now Let s do Some

Page 46 Troubleshooting-Example #1

A Real Troubleshooting Example 30 No Peaks 28 26 24 22 20 18 16 14 10 20 30 40 50 Page 47

Logical Steps Taken to Find Peaks (most of our problems are leaks and plugs) Is the flame Lit? put glass piece over FID outlet----answer in this case, Water condenses look at output in instrument guage-- is the digital value greater than 0.0? Answer in this case is approximately 16.2 pico amps Is there flow through the column? disconnect column from detector and measure flow with bubble solution or meter Answer in this case was YES THERE IS FLOW Assess the observations Flame is lit and we have flow from end of column Hypothesis: Sample not getting on column-syringe plugged? Take syringe out and make injection manually on a dry paper towel Answer towel stayes dry (Syringe was clogged with septum) Pull plunger out top, add solvent and replace plunger will usually dislodge septum particle (should hear a little pop) If you can t dislodge plug, Replace syringe Reassemble the Injector & Re-inject Page 48

Peaks!! 30 28 26 24 22 20 18 16 14 0 10 20 30 40 50 Page 49

Page 50 Troubleshooting-Example #2

8.0e4 7.0e4 6.0e4 5.0e4 2.71 DB-624 COLUMN 1. 1,2-Dichloropropane 2. Octane 3. Tetrachloroethylene 4. Chlorobenzene 5. Nonane 7.43 QC Test Mix 10.92 Column: DB-624 30m x 53mm I.D., 3.0µm Carrier: Helium at 40 cm/sec measured at 35 C Injector: Mega Direct, 260 C Detector: FID, 300 C Oven: 35 C for 1.50 min 30 /min to 65 for 10 min 4.0e4 3.0e4 12.49 17.42 20.78 2.0e4 1.0e4 5 10 15 20 25 Time (min.) Page 51

Example of Column Contamination 1.5e4 2.21 1.4e4 1.3e4 1.2e4 3.30 DB-624 QC Test Mix* After 75 Injections of Oily Sample 1.1e4 1.0e4 9000 6.03 8000 9.26 7000 10.46 14.40 17.86 6000 0 5 10 15 20 Time (min.) *Temperature program// 35 C hold 1.50 min // 30 /min to 65 C, hold 10 min Page 52

Column and Liner Contamination Inlet coil of column Page 53

1.2e4 1.1e4 Example of Column Contamination 2.80 Removed 1 1/2 m from injector end * 1.0e4 9000 7.34 10.79 8000 12.33 17.19 7000 20.56 6000 5000 0 5 10 Time (min.) 15 20 25 *Before Column rinse and bake Temperature program // 35 C hold 1.50 min // 30 /min to 65 C, hold 10 min Page 54

Page 55 Looks Fixed Doesn't it?

Example of Column Contamination 1.3e4 1 1/2 mtrs removed* QC Test mix to Upper Temperature Limit 1.2e4 1.1e4 1.0e4 9000 8000 7000 6000 5000 0 10 20 30 40 50 60 70 Time (min.) *Before Column rinse and bake. Temperature program // 35 C, hold 1.50 min // 30 /min to 65 C, hold 15 min // 20 /min to 260, hold 50 min Page 56

Backflush Column Rinse with 10ml each: Methanol, Methylene Chloride, Hexane Capillary column Special connector and ferrule Beaker for solvent collection 1/16" flexible teflon line to regulated pressure source Flexible teflon tubing Cap Capillary column Special adapter Vial Page 57

Jumper Tube Test Used to Isolate Source of Contamination. Cap off the detector and establish normal gas flows and temperature.. Plot the baseline using a temperature program. If flat.... Connect 1 meter of deactivated tubing between the injector and detector. Plot the baseline using a temperature program. If flat.... Install the column.. Plot the baseline using a temperature program. Page 58

1.0e4 Contaminated Inlet Jumper Tube Test* 9000 8000 7000 6000 5000 0 10 20 30 40 Time (min.) *1/2 mtr length of.53 mm I.D. deactivated tubing Temperature program // 35 C, hold 1.50 min // 30 /min to 65 C for 15 min Page 59

Rinsing Injector Carrier gas line GC Oven Injector body MeCl 2 C6 Page 60

Troubleshooting Tips 1. Isolate the problem. (Blank Run, Inject Un-retained Compound, Jumper Tube Test) 2. Change only one variable at a time. 3. Compare before/after chromatograms. (Peak shape, response, retention, baseline rise, background, look for trends, etc.) 4. Utilize Technical Support. Page 61

Remember Complete system = Carrier Gas + Injector + Column + Detector + Data System Multiple cause and effect Do not change too many variables at once Page 62

Contact Agilent Chemistries and Supplies Technical Support 1-800-227-9770 Option 3, Option 3: Option 1 for GC/GCMS Columns and Supplies Option 2 for LC/LCMS Columns and Supplies Option 3 for Sample Preparation, Filtration and QuEChERS Option 4 for Spectroscopy Supplies Available in the USA 8-5 all time zones gc-column-support@agilent.com lc-column-support@agilent.com spp-support@agilent.com spectro-supplies-support@agilent.com