MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES,

Similar documents
NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

BMRX Series ROTARY LEVEL CONTROL

Installation and Service Instructions for EX Series Explosion-proof Switches

10 S e r i e s PRESSURE SWITCH. features

SPC-PANEL Simplex, Single Phase Pump Control Panel

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

INSTALLATION & OPERATION MANUAL

LED STRIP LIGHTING KIT EUKT04 WW30

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Operating and Installation Instructions

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

J 6 Se r i e s. Pressure and Vacuum switches. features

Pump Installation and Service Manual HRS Hydromatic Retractable System

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

CTFRP Series Power Supplies

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Easytork Solenoid Valve IOM

Tissue Master. User Manual

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

1000 Series Piston Type Differential Pressure Gauges

Electric Actuator Installation, Operation & Maintenance Manual

SETRA Operating Instructions Series DPT 230 Pressure Transducers

1100 Series Piston Type Differential Pressure Gauges

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Model 5000 Level Controller

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

80PK-2A Type K Immersion Probe

Air Curtain. Installation, Operating and Maintenance Instructions

Model C230 Pump Controller

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

Installation Manual DIAPHRAGM WELL TANK

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

Installation and Operating Manual

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

EStrong-series Emergency Stop

Safety Sentry Electronic Breakaway Switch

MODEL L-8 HARWIL CORPORATION 541 KINETIC DRIVE, OXNARD, CA TEL: (805) FAX: (805)

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

INSTALLATION INSTRUCTIONS

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

SOLAR DASH CHARGING SYSTEM USER GUIDE

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

BCFS Belt Driven Centrifugal Filtered Supply Fans

Straight-Bore Clutch LSCC-32, 44, 54

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

User s Guide PSW12 SERIES. Pressure Switches. Shop online at CERTIFIED DUAL SEAL

Push Button Pendants Manual 80 Series

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

HA/HAB Fiberglass Wall Mount Ventilators

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Warner Electric UNIBRAKE Motor Brakes

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

TBM Series 3-Way Ball Valve

PVI 60KW, PVI 82KW, PVI 95KW

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Heavy Duty Industrial Foot Switches

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

INSTALLATION INSTRUCTION & OWNER S MANUAL

M-100 Adjustable flow switch with right-angle flow

Model 90 Twin Control Unit

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

MAXIGARD A2000 SPEED SWITCH. Introduction

BlinkerBeam Solar Controller

BEAMER Tilt Beam Sensor

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Adjustable Dead Band Pressure Switches

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

SUNC3000 / Item #40885

ProFlo FatBoy

Procedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub

NEMA 4 High Pressure High Set Point High Accuracy Pressure Switch SPECIFICATIONS

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

( Versions Available)

Electromagnetic Particle Brakes Model: PRB-H

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

Mechanical Physician Scale Installation & Operation Instructions PN

Adjustable Dead Band Pressure Switches

Transcription:

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES, ENCLOSURE 6N FOR EXPLOSIVE ATMOSPHERES INSTALLATION AND OPERATION MANUAL PN 610-0014 E

Manual No. 610-0014 Rev E Neo-Dyn 28150 Industry Drive Valencia, CA 91355 Tel: (661) 295-4000 World Wide Web: www.neodyn.com Copyright 2002 ITT Industries WARNING CAUTION NOTE SPECIAL CONDITIONS FOR SAFE USE Important Information The product warranty applicable to this ITT Neo-Dyn instrument is as stated on page 12 of this manual. Should any after-delivery problems arise, please contact ITT Neo-Dyn s Customer Service using the information above. Our normal business hours are weekdays, 7:00 am to 3:30 PM, Pacific Time. Before installing this Temperature Switch, become familiar with the installation and adjustment instructions in Chapters 2 and 3. Indicates a hazard which can cause severe personal injury, death, or substantial property damage if the warning is ignored. Indicates a hazard which will or can cause minor personal injury or property damage if the caution is ignored. Indicates additional information about a particular item necessary to the operation of the unit. The Electrical Snap Switch Assemblies shall be installed such that the equipment wiring is protected from mechanical damage by the use of metal conduit or a method providing equivalent protection. The equipment wiring must not be subjected to tension or torque. If it is to be terminated within a potentially explosive atmosphere, a suitably certified termination facility must be used. This document contains proprietary information, which is the property of Neo-Dyn, a unit of ITT Industries. This document may not be reproduced, either in part or in full, without the consent of ITT Industries. Enclosure 6N Temperature Switches Page i

TABLE OF CONTENTS PAGE CHAPTER 1 INTRODUCTION... 1 OTHER CONFIGURATIONS... 2 CUSTOMER SERVICE... 2 CHAPTER 2 INSTALLATION AND OPERATION... 3 MOUNTING... 3 PROCESS CONNECTIONS... 4 PROCESS MEDIA... 4 ELECTRICAL CONNECTIONS... 4 POTENTIALLY EXPLOSIVE ATMOSPHERES (HAZARDOUS LOCATIONS)... 5 ALLOWABLE PRESSURES AND TEMPERATURES... 5 CHAPTER 3 ADJUSTMENTS AND TROUBLESHOOTING. 7 SETPOINT ADJUSTMENT... 7 TROUBLESHOOTING... 8 CHAPTER 4 SPECIFICATIONS... 9 STANDARD... 9 OPTIONS... 11 WARRANTY INFORMATION... 12 Page ii Installation and Operation Manual

CHAPTER 1 INTRODUCTION The Neo-Dyn Enclosure 6N Temperature Switches described in this manual are weather and explosion-proof, electromechanical sensing devices designed for a wide range of applications in pneumatic and hydraulic systems up to 1500 psig, and for use in Zone 1 Potentially Explosive Atmospheres (Division 1 hazardous locations). Model 100T has its temperature sensor mounted on its case, while Model 100TC has a remote sensor, mounted at the end of a flexible capillary. The wetted materials of both models include a welded corrosion-resistant steel (CRES) temperature sensor. Model 100T has a Teflon seal, while Model 100TC has a graphite-filled non-asbestos packing. Setpoint adjustments are easily made through the adjustable range by turning an adjustment nut located inside the housing. The standard configuration of these switches will switch up to 11 amp at 125 or 250 VAC, 5 amp resistive at 28 VDC, or 0.5 amp resistive at 125 VDC. When ordered with M Option, the switch is rated for currents to one amp, but its bifurcated gold contacts will reliably switch currents in the milliampere and microampere ranges. These switches have CE Mark, and they have weatherproof enclosures with IP66 ingress protection and that meet the requirements of NEMA 3. 3R, 3S, 4, 4X and 13. The electrical subassemblies are listed by Underwrites Laboratories, CSA International, Factory Mutual and ATEX. Enclosure 6N Temperature Switches Page 1

CONDUIT FITTING 1/2-14 NPT MALE TEMPERATURE PROBE FREE LEADS 18 AWG 18 IN (46 CM) LONG HOUSING COVER PROCESS FITTING 1/2-14 NPT MALE (LOCATED AT END OF CAPILLARY ON MODEL 100TC) 4X COVER SCREW WARNING Figure 1: Models 100T and 100TC Enclosure 6N Adjustable Temperature Switches for Explosion Proof Applications Hidden lines indicate mounting holes under the cover (see page 3). Chapter 4 on page 9 contains complete specifications. OTHER CONFIGURATIONS The models described in this manual are also available in special and factory-set configurations. For these units, follow the installation and operating instructions herein, except adhere to the pressure and electrical limits marked on the units. CUSTOMER SERVICE If you have any questions about these Temperature Switches that are not covered in this manual, you can contact Neo-Dyn or our representatives in several ways. The Neo-Dyn customer service phone number is (661) 295-4000. Our customer service department is open from 7:00 am to 3:30 p.m. Pacific Time. Our Internet site is www.neodyn.com; it includes lists of sales representatives and distributors. Page 2 Installation and Operation Manual

CHAPTER 2 INSTALLATION AND OPERATION WARNING WARNING WARNING WARNING Installation of these Neo-Dyn Enclosure 6N temperature switches is straightforward. However, they must be installed by a qualified electrician, in compliance with all local and national electrical codes. Electrical Hazard Do not make electrical connections while power is on. Always check for multiple circuits. Always make sure grounding is adequate. MOUNTING Model 100T can be mounted directly to the process connection if there is no significant vibration and the fluid lines are capable of supporting the weight. It can also be attached to a flat surface, such as a wall or panel, using.250 in. diameter or M6 socket-head cap screws through the mounting holes that are accessed by removing the housing cover; allow.5 in (12.7 mm) screw length above the mounting surface. These holes are located on two corners of a 2.72 inch (6.91 cm) square, or 3.85 inches (9.77 cm) apart on a 45 diagonal. Model 100TC must be mounted by this method, as its remote temperature sensor will not support the housing. Do not overtighten the screws when replacing the cover. Enclosure 6N Temperature Switches Page 3

PROCESS CONNECTIONS CAUTION The process connections are: Model 100T: ½ - 14 NPT male standard. The.25 in. (6.4 mm) dia. probe extends 3.0 in. (76 mm) past the end of the pipe thread. Model 100TC: ½ - 14 NPT male standard. The.38 in. (9.7 mm) dia. probe extends 4.50 in. (114 mm) min. from the end of the pipe thread, and can be extended an additional 9.5 in. (241 mm). After this length adjustment, torque the gland nut in the pipe fitting to 230 ± 20 in-lb (26.0 ± 2.3 newton-meters). When installing the Temperature Switch, always: Make sure that the unit and your system have matching threads. Use the wrench flats provided. Seal all joints with pipe joint sealing compound. Avoid excessive torque on all threaded connections. PROCESS MEDIA Process media must be compatible with the wetted materials listed in Chapter 4 starting on page 10. Compatibility is defined by an A rating in the Chemical Resistance Guide for Metals and Alloys, and, as applicable, the Chemical Resistance Guide for Plastics or the Chemical Resistance Guide for Elastomers. All are published by Compass Publications and are available from the National Association of Corrosion Engineers (NACE), Houston, Texas; telephone 281 228-6200. WARNING ELECTRICAL CONNECTIONS 18 AWG free leads, 18 inches (48.3 cm) long are standard. See Figure 2 below for color codes. All field wiring must comply with requirements of the NEC or applicable local or national electrical codes, including wire gauges and insulation temperature ratings. Conduit seals may be required. Page 4 Installation and Operation Manual

RED NC1 BRN C1 RED NC1 BRN C1 BLU NO1 BLK NC2 GRN SCREW YEL C2 VIO NO2 GRN SCREW FORM CC FORM C WARNING Figure 2. Form C and CC Schematics Shown Below the Decreasing Setpoint POTENTIALLY EXPLOSIVE ATMOSPHERES (HAZARDOUS LOCATIONS) Suitable for Zone 1, Eex d IIC explosive atmospheres, in accordance with Potentially Explosive Atmospheres Directive 94/9/EC (ATEX) Suitable for Division 1; Class 1, Groups A, B, C and D; Class II, Groups E, F and G hazardous locations, in accordance with the National Electric Code (NEC), and applicable UL and CSA specifications. ALLOWABLE PRESSURES AND TEMPERATURES Do not exceed the 1500 psig (103.5 bar) Maximum Operating Pressure (System Pressure) in normal operation. The 2250 psig (155.1 bar) Proof Pressure is provided to give the maximum allowable pressure without causing permanent damage to the temperature switch in the event of an over-pressure condition. Set pressure relief/safety valves below this setting. Enclosure 6N Temperature Switches Page 5

Similarly, the marked Proof Temperature is the maximum temperature the process media could reach in an over-temperature condition without damaging the switch. Page 6 Installation and Operation Manual

CHAPTER 3 ADJUSTMENTS AND TROUBLESHOOTING The factory-set setpoint or adjustable setpoint range is marked on the nameplate of the switch. This section describes the adjustments needed after an Adjustable Temperature Switch has been properly installed. SETPOINT ADJUSTMENT Disconnect the electrical power. Check for multiple circuits. 1. Loosen the screws on the housing cover, and move it aside. 2. Check the setpoints per paragraphs 4 and 5 below for precise adjustments. 3. The adjustment nut can be rotated by hand or with an openend wrench or similar tool. The range scale indicates the increasing setpoint and is intended to be used only as an approximate guide. Make precise final adjustments using the measurements described in para 4 and 5 below. 4. To check the increasing setpoint of a temperature switch, insert the temperature probe into a fluid bath so that the hex is within 3/8 inch (9.5 mm) of the surface, and also insert a calibrated thermometer into the fluid next to the probe. Slowly increase the temperature of the fluid (try not to exceed 5 C or 9 F per minute) until actuation is noted by listening to the audible snap of the Belleville spring, or with an ohmmeter across the appropriate terminals in the terminal block. Enclosure 6N Temperature Switches Page 7

CAUTION 5. If you want to check the decreasing setpoint, slowly decrease the temperature after the switch has actuated and note the value at which the audible snap or an ohmmeter indicates deactuation. Deadband may be calculated if desired by subtracting the decreasing setpoint reading from the increasing setpoint reading. 6. Replace the cover by moving it back into position over the top of the housing and tightening the screws until the cover is snug against its gasket. Do not over-tighten, as this could damage the gasket. TROUBLESHOOTING In-service problems are unlikely, but the following paragraphs suggest ways to verify any problems that might arise: 1. Failure to Switch If application of temperature 10% greater than the adjusted setpoint fails to produce actuation, first check for contamination in the process connection, and verify that the expected pressure is reaching the sensing diaphragm or piston, or temperature is reaching the temperature probe. If the Belleville spring can be heard to audibly snap, but an ohmmeter indicates no electrical switching, the cause is probably stuck or burned switch contacts, or the switch element has moved away from the position where it was synchronized with the snap action. Return the unit for repair. Contact ITT directly, or your local sales representative or distributor (see www.neodyn.com for a contact list). If application of temperature 10% greater than the adjusted setpoint fails to produce an audible snap of the Belleville spring, there is probably a mechanical failure or binding due to contamination. Return the unit for repair. 2. Calibration Shifts If it is suspected that the setpoints have shifted, recheck them per paragraphs 4 and 5 of the Setpoint Adjustment section of this chapter above. If you verify unstable or drifting setpoints, return the unit for repair. Page 8 Installation and Operation Manual

CHAPTER 4 SPECIFICATIONS This section shows standard specifications and available options. STANDARD Interfaces Weight: approximately 3 pounds (1.4 kg) each Conduit Connection: ½ - 14 NPT male Standard Process Connection: ½ - 14 NPT male Part Number The part number contains information about which configurations and options are included in your Adjustable Temperature Switch. To determine the sensing range, electrical rating, and options, compare the part number of your unit with the information in Figure 3 below and the following tables. NOTE 100T 3 B CC 6 MN Model Series Options Wetted Material Explosion-Proof Elec. Range Letter Elec. Form (C or CC) Figure 3. Part Number Breakdown Part number format varies for specials. Enclosure 6N Temperature Switches Page 9

Wetted Materials No Table 1 Description 3 300-series CRES with Viton seal, except Teflon seal on Range J (Model 100T) 5 300-series CRES with graphite-filled non-asbestos packing (Model 100TC) Electrical and Ambient Temperature Ratings Minimum ambient temperature is -40 C (-40 F) Form C6N (SPDT): 11 amp @ 125 or 250 VAC to +75 C (+167 F) max, T5; 11 amp @ 125 or 250 VAC to +60 C (+140 F) max, T6; 5 amp @ 125 or 250 VAC 5; amp resistive, 3 amp inductive @ 28 VDC;.5 amp resistive,.04 amp inductive @ 125 VDC to +70 C (+158 F) max, T6. Form CC6N (DPDT): 11 amp @ 125 or 250 VAC to +65 C (+176 F) max, T4A; 11 amp @ 125 or 250 VAC to +45 C (+116 F) max, T6; 5 amp @ 125 or 250 VAC; 5 amp resistive, 3 amp inductive @ 28 VDC;.5 amp resistive,.04 amp inductive @ 125 VDC to +70 C (+158 F) max, T6. Form C6MN or CC6MN (SPDT or DPDT with M Option): 1 amp @ 125 VAC to +70 C (+158 F) max, T6. Listing Agency Approvals CE Mark Switch Subassemblies All models Underwriters Laboratories CSA International Factory Mutual SIRA (ATEX & IECEx) Page 10 Installation and Operation Manual

Pressure Ratings Maximum Operating Pressure: 1500 psig (103.5 bar) Proof Pressure: 2250 psig (155.1 bar) Weather Proof Ratings: Ingress protection IP66 Enclosure type 3, 3R, 3S, 4, 4X, 13 (NEMA) OPTIONS The available options for standard switches are listed below. These options can be combined; every included option will be indicated in the part number of the unit. Table 2 Option Description Available on Model A Epoxy-painted exterior All M W Gold Electrical Contacts For Extremely Low Current Applications Corrosion-resistant steel screws, exterior All All X CE mark All Enclosure 6N Temperature Switches Page 11

WARRANTY INFORMATION A. Warranty: ITT Industries (ITT) warrants that at the time of shipment, the products manufactured by ITT Neo-Dyn and sold hereunder, will be free from defects in material and workmanship and will conform to the specifications furnished or approved by ITT. B. Warranty Adjustment: If any defect within this warranty appears, the Buyer shall notify ITT immediately. ITT agrees to repair or furnish a replacement for, but not install, any product which, within one (1) year from the date of shipment by ITT shall, upon test and examination by ITT, prove defective within the above warranty. No product will be accepted for return or replacement without the written authorization of ITT. Upon such authorization, and in accordance with instructions by ITT, the product will be returned with shipping charges prepaid by the Buyer. Replacements made under this warranty will be shipped prepaid. C. Exclusion from Warranty: THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY, OR FITNESS, OR OTHERWISE. Components manufactured by any supplier other than ITT shall bear only the warranty made by the manufacturer of that product, and ITT assumes no responsibility for the performance or reliability of the unit as a whole. In no event shall ITT be liable for indirect, incidental or consequential damages nor shall the liability of ITT arising in connection with any products sold hereunder (whether such liability arises from a claim based on contract, warranty, tort or otherwise) exceed the actual amount paid by Buyer to ITT for the products delivered hereunder. The warranty does not extend to any product manufactured by ITT, which has been subject to misuse, neglect, accident, improper installation, or to use in violation of instructions furnished by ITT. The warranty does not extend to or apply to any unit, which has been repaired or altered at any place other than at ITT s factory or service locations, by persons not expressly approved by ITT.