Opticom Rack Mount Fiber Enclosures

Similar documents
PanView iq (PViQ) Fiber Tray

Fiber Optic Splice Module

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

INSTALLATION INSTRUCTIONS

8400 Series Fiber Distribution System

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

Network Zone System. Part Numbers: Z22N-****** Z22R-****

Instructions for Use - Opt-X 1000i Enclosure

Z22C-** Preconfigured Network Zone System

FIBER CONNECTOR SAFETY WARNINGS

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

Fiber Splice Panel Rack Mount User Manual

Fiber Connector Shelf (CCS)

Universal Network Zone System Part Numbers: Z23U-****

Network Zone System Part Numbers: Z23N-***** Z23R-****

INSTALLATION INSTRUCTIONS

FL2000 Termination/Splice Panels User Manual

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

Environmental Distribution Center (EDC-06P-NH)

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

INLET DUCT FOR CISCO 6880 Part Number(s) DIRLC25S23W

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

FIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction

INLET DUCT FOR CISCO 9513 SWITCH Part Number: DIBBC2314S21W

Universal Splice Tray Installation Instructions

PANZONE Overhead Distribution Racks

Splice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity

OFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

FOSC-400A4 INSTALLATION INSTRUCTION

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)

INSTALLATION INSTRUCTIONS

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

Fiber optic splice closure

FIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

Upgrading the Sure Coat Modular Gun Control System

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

Route/Protect C For service and technical support, call A. System Overview B1. Cable. Ties B2. Cable.

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

COYOTE LCC (Low Count Closure)

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

M9/D (-020 thru -022) M11/D (-020 thru -022)

Access your fiber assemblies in the front of the enclosure to your fiber splices via a rear door without disturbing the fiber.

FIST-GMS2. FIST Generic Mixed Shelf MK2. Contents. 1 Introduction. 5 Termination of the pigtails. 2 General. 6 Splicing + fiber storage

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

Swing-Out Style Fiber Distribution Units

PANZONE Overhead Distribution Racks

INSTALLATION INSTRUCTIONS

Multilink s Family of Wall Mount Enclosures

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

INSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.

ELECTRICAL SOLUTIONS C4.1. A. System Overview. B1. Cable Ties. B2. Cable Accessories. B3. Stainless Steel Ties. C1. Wiring Duct. C2.

TESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM

FOSC-100 B/H FOSC-100 B2/H

CS Fiber Optic Splice Case. Instruction

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

BEND LIMITING TUBING AND ACCESSORIES

Chapter 3. Installing Equipment

Ortronics. Mighty Mo. GX Cabinets. Designed to Perform, Configured to Fit

COYOTE STP (Service Termination Point)

NEMA-Rated Fiber Optic Wallmount Enclosure. Protects your fiber cabling in a damp environment.

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

Instruction, EDGE8-04U Quick Start Guide

P Original Series Cargo Van Lift Mounting Instructions Fullsize Ford Van present. Preparing the Gate

Installing the Switch

Interconnect Cable Simplex and Duplex

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION

INSTALLATION INSTRUCTIONS

RIDGID 12 in. SLIDING COMPOUND MITER SAW MODEL NUMBER MS1290LZ1 FIGURE A. See Figure E

12-Inch Hybrid Fiber Access Terminal Installation Instructions

LSW Connector Module User Manual

COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications

BASEWEST Operating & Maintenance Manual. Battery Power Units, Escape Slide Lighting Systems. Model 725 thru 785. Reissued 10 March 2014

Racks M A N A G E M E N T. Premise Connectivity Systems. A N DCable. Racks and Cable Management

COYOTE STP (Service Termination Point)

DVS Cypress Face Installation Instructions (SKU )

Signal Mirror Installation Instructions Toyota Sequoia Limited, 2004 Toyota Tundra D-Cab

ELECTRICAL SOLUTIONS

Installing the STS-4CH Dodge Challenger Sequential Turn Signal System

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

235/245400, , 28N

HANDLING OF ASSEMBLY... 1 RRH END OF ASSEMBLY... 1 BASE STATION END OF ASSEMBLY... 7 POWER CODING REVISION HISTORY... 11

Assembly Instructions

Wall Oven Series -2. Parts List & Exploded Views. 30 Oven Contol Panel Parts List Single and Double Oven. 36 Oven Control Panel Parts List Single Oven

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

Transcription:

Opticom Rack Mount Fiber Enclosures Part Numbers: FRME1U, FRME2U Panduit Corp. 2011 INSTALLATION INSTRUCTIONS FRME1U FRME2U Contents - (#) indicates FRME2U quantity 1 - ENCLOSURE 2 - MOUNTING BRACKETS 4 - #10-32 x 5/16" SCREWS 4 - #12-24 x 1/2" SCREWS 4 - M6 x 1 SCREWS 1 - #10-32 x 3/8" SCREW 3 - #10-32 HEX NUTS 1 (2) - CABLE ENTRY GROMMET(S) 1 - STRAIN RELIEF BRACKET 2 (4) - BEND RADIUS CONTROL CLIPS 2 (4) - NYLATCH PLUNGERS 2 (4) - NYLATCH GROMMETS 2 (3) - ADHESIVE BACKED MOUNTS 3 - ADHESIVE BEVEL ENTRY CLIPS 2 - SLACK SPOOLS 2 (3) -TAK-TYS, 6" pcs. 4 - CABLE TIES, PLT2S-M0 1 - CAUTION LABEL 1 - LASER WARNING LABEL WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. DO NOT LOOK DIRECTLY INTO THE END OF THE CONNECTOR. DO NOT INSPECT WITH MAGNIFYING DEVICES. MAINTAIN CAP ON UNMATED CONNECTORS. CAUTION: Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the manufacturer s cable specification sheet for the specific cable in use. Follow TIA/EIA-568A, 569, 606, and 607 installation guidelines where applicable. Care should be taken when opening and closing fully loaded drawer in order to protect fiber components. ASSEMBLY VIEW showing Fiber Adapter Panels (FAPs) - sold separately. Bend Radius Control Clips FAPs (sold separately) Slack Spools Cover Trunk or Interconnect Cable Entry Grommet Mounting Brackets Strain Relief Bracket Front Door Assembly (shown in open position) Note: Front and rear doors are not interchangeable NyLatch Plungers and Grommets Enclosure Sliding Drawer Enclosure Figure 1 Page 1 of 8

Preparation and Rack Mounting Figure 2 Determine where the cable will enter the enclosure. Carefully remove the knock-out so as not to damage the surrounding sheet metal. DO NOT install the grommet at this stage. Grommet will be installed after the enclosure is mounted to the rack. Figure 2 Orientation for 19" rack mounting (2) #10-32 x 5/16" screws Determine the proper orientation for the mounting brackets according to rack size being used. Install mounting bracket to the enclosure using (2) #10-32 x 5/16" screws. Repeat for other side. Orientation for 23" rack mounting Figure 3A Use (2) #12-24 x 1/2" screws on each side Place enclosure mounting brackets at desired position on the rack. Mount the enclosure to the rack using (4) #12-24 x 1/2" screws. Use (4) M6 x 1 screws if mounting to a metric rack. Figure 3B Enclosure is accessible from the rear for mounting of slack spools, Fiber Optic Splice Modules (FOSMs) and other equipment. (Rear View) Figure 3C Page 2 of 8

Grommet Cutting Diagram Cut out the small circle for 1" dia. innerduct Cut the straight lines for smaller bundle sizes After the enclosure is mounted to the rack, determine the size of the innerduct (if any) that will be used to bring the cable into the enclosure. Prepare grommet according to the proper cutting diagram to the left. Cut out the small circle for 1-1/4" dia. innerduct Cut out the large circle for 1-1/2" dia. innerduct Cut the straight lines when not using any innerduct Figure 4A Grommet Figure 4B #10-32 x 3/8" Screw Strain Relief Bracket #10-32 Hex Nut Install the strain relief bracket near where the cable will enter the enclosure. Secure with #10-32 x 3/8" screw and #10-32 hex nut. (cover not shown for clarity) Figure 5 Page 3 of 8

Field Termination or Pre-Terminated Trunk Installation FAPs (3) capacity for FRME1U (6) capacity for FRME2U Tray shown fully extended (cables omitted for clarity) Slack Spools Slack Spools may be mounted with adhesive backing only or securing with #10-32 hex nuts. Punch a hole through the adhesive backing and place slack spools over #10-32 studs on the tray. Secure with #10-32 hex nuts. Note spool orientation. Position FAPs between upright flanges as shown. Once mounted, fully seat NyLatches to secure. Fully extend tray to ensure proper amount of slack is used. Note orientation of spools Figure 6A Page 4 of 8

Tak-Ty the cables utilizing slots in enclosure Sub-unit tubes Free floating Tak-Ty A Grommet Fixed Tak-Ty Cable length between point A and point B is approx. 31" [.787m] Route fiber through cable entry grommet as shown. Use enough cable length to ensure one complete loop of individual fibers around slack spools. Leave enough jacketed slack so when the drawer is fully extended the cables are not put under tension. DO NOT use so much slack that the drawer cannot be returned to its home position. (See Figure 6C) Use Tak-Tys to secure fiber cords at the cable entry location and other points as shown. B Adhesive Backed Mount with Tak-Ty Individual Fiber Break out point (See detail) Individual Fiber Cable Jacket Adhesive Backed Mount with Tak-Ty 1.0" Fiber Break out Detail Be sure adhesive backed mount is positioned to secure the jacketed trunk cable. DO NOT secure individual 900µm buffered fibers Drawer in extended position Figure 6B Drawer in home position Figure 6C Page 5 of 8

Fiber Optic Splice Module (FOSM) Installation - sold separately FOSM (3) capacity for FRME1U (6) capacity for FRME2U Place first FOSM over #10-32 studs on sliding tray and secure with #10-32 hex nuts. Remaining FOSMs are stacked on top of each other and snap in place. Position FAPs between upright flanges as shown. Once mounted, fully seat NyLatches to secure. FAPs (3) capacity for FRME1U (6) capacity for FRME2U Figure 7A Tak-Ty the cables utilizing slots in enclosure Grommet Sub-unit tubes A Fixed Tak-Ty Route fiber through cable entry grommet as shown. Use enough cable length to ensure one complete loop of individual fibers around FOSM slack spools. Free floating Tak-Ty B Cable length between point A and point B is approx 32.5" [.825m] Route 900µm buffered fiber from the trunk cable and splice to pigtail per instructions in FS001*, FOSM Opticom Fiber Optic Splice Module Installation Instructions. Leave enough jacketed slack so when the drawer is fully extended the cables are not put under tension. DO NOT use so much slack that the drawer cannot be returned to its home position. (See Figure 7C) Use Tak-Tys to secure fiber cords at the cable entry location and other points as shown. Individual fiber break out point * Denotes revision letter. Drawer in extended position Page 6 of 8 Figure 7B

Drawer in home position Figure 7C Bend Radius Control Clip Installation Bend Radius Control Clip Sliding Tray Flange Plunger Install plunger into grommet, but do not fully seat. Slide bend radius control clip over the sliding tray flange as shown. Push grommet/plunger through bend radius control clip and sliding tray flange holes. Fully seat plunger into grommet to secure. Repeat for other side. Grommet Figure 8A Bend radius control clips must be installed to retain the front door. Page 7 of 8

Patch Cord Installation Install patch cords into FAPs routing through bend radius control clips and maintaining proper patch cord bend radius. Figure 9 Door Attachment Pin Install the front door as follows. Install the rear door in a similar manner. Inner Tab Hinge Outer Tab Position the door so that it rests on top of the hinge and up against the inner and outer tabs. Bend the bottom of the right side of the door until the pin drops into the hinge. Repeat for the left side. Bend Figure 10 The final door position should be on the outside of the inner tabs. Inner Tabs If the door is installed properly it will open and close freely. Attach Laser Warning Label and Caution Label where they are clearly visible. Figure 11 For Instructions in Local Languages and Technical Support: www.panduit.com/resources/install_maintain.asp www.panduit.com Page 8 of 8 E-mail: techsupport@panduit.com Phone: 866-405-6654