TYPE APPROVED CEMS GREEN EFFICIENCY ON BOARD

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

Fuji Electric France S.A.S. Instrumentation & measurement solutions

Fuel Consumption Measurement

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY OFFICE OF TRANSPORTATION AND AIR QUALITY ENGINE INTERNATIONAL AIR POLLUTION PREVENTION CERTIFICATE

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY OFFICE OF TRANSPORTATION AND AIR QUALITY ENGINE INTERNATIONAL AIR POLLUTION PREVENTION CERTIFICATE

RESOLUTION MEPC.272(69) (Adopted on 22 April 2016) AMENDMENTS TO THE NOX TECHNICAL CODE 2008 NITROGEN OXIDES FROM MARINE DIESEL ENGINES

RESOLUTION MEPC.103(49) Adopted on 18 July 2003 GUIDELINES FOR ON-BOARD NOx VERIFICATION PROCEDURE - DIRECT MEASUREMENT AND MONITORING METHOD

Zero NOx Customised SCR

Technical File Engine Model: MD706MX (4.2L 230) - MD706MS (4.2L 200)

Technical File D3*GL*E3

Wärtsilä NO X Reducer. Environmental Efficiency

Baltic Sea Parliamentary Conference. MARPOL Annex VI TECHNOLOGY & COMPLIANCE. Ramona Zettelmaier Lloyd s Register

"Exhaust Gas Scrubbers Abatement System as an Alternative under IMO MARPOL Annex VI''

INTERNATIONAL MARITIME ORGANIZATION (IMO) Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

T-Sense _ 660. Optical Torque Measuring Systems. Product Bulletin

AVL Particle Measurement System Aviation

TESTO 350 Upgrades / Accessories / Spare Parts. Replacement Sensors

Excellence in gas analyzers since Over 180 years of JY optical experience. The expertise of Horiba combustion technology

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

NO x FAQ. Disclaimer. Content

Technical File D16-MH*CCS*E3E2C1. According to Revised MARPOL Annex VI and NOx Technical Code Contents

Bunkering With New Fuels Building on Strong Foundations.

ECA Compliance & PM. Thomas Kirk Director of Environmental Programs. Ottawa, Canada 9 September 2014

Challenges for sustainable freight transport Maritime transport. Elena Seco Gª Valdecasas Director Spanish Shipowners Association - ANAVE

MTU Friedrichshafen. MTU Project No. - ENGINE DATA - Printout: (y-m-d) Sheet 1

AKVdiesel. Automated kinematic Viscometer key features. Fully complies with ASTM D445. Two measuring positions. Remove cap and pour in sample

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

ViscoSense 3D. Viscosity & Density Measurement Enabling Mass Flow Measurement. Product Bulletin TO BE REALLY 1 SURE

Product line : Marine

IMO III Exhaust Emissions. MTU Solutions / Design Concepts. Application Center Marine & Offshore November 2016

Testing Instrumentation Gasboard 5020 for exhaust gases from petrol or LPG engines

MARINE POWER SOLUTIONS EDITION 2018 (MAY)

Fuel Consumption Measurement _ 124. Application Bulletin

Differential Pressure Gauges (701P Series)

O 2 CO CO 2 NO NO 2 NO x

Portable TOC Analyser for Stack Emissions

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Flash Point Process Analyzer

IFO 380 HEAVY FUEL OIL Vessel using Xbee Natural Fuel Additive

Marine generators Proven generators for reliable power on board

Online data sheet GMS800 FIDOR EXTRACTIVE GAS ANALYZERS

Standardized Bunker Supplier Accreditation Scheme to Enhance Marine Environmental Protection in SOMS

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Technical File and Copy of United States Environmental Protection Agency (EPA) Statement of Compliance

Mistral LC-MS Evolution Specification

Commercial Marine Presentation

Table 0.1 Summary Pollutant Discharge Test Results Engine Manufacturer. Number 24652

Flow Measurement SITRANS F C

PureSO x. Exhaust gas cleaning. This document, and more, is available for download from Martin's Marine Engineering Page -

Guascor MARINE DIESEL

Guascor MARINE DIESEL

Instruments for the Analysis of Petroleum Products. Oxidation Stability

Technical specification agenitor 306 NG

Emission measurement equipment was from both Volvo and Veolia was installed in the test buses.

DNV GL EGC system approval and experience

ANNEX 13. UNIFIED INTERPRETATIONS TO MARPOL ANNEX VI AND THE NO x TECHNICAL CODE

KAWASAKI Environment-friendly New engine technology

Technical specification agenitor 404b NG

Technical specification agenitor 408 NG

-=-ffi' MINISTRY OF TRANSPORT AND COMMUNICATIONS DEPARTMENT OF MARINE ADMINISTRATION

Data Sheet 10/ EN November 2004

RESOLUTION MEPC.198(62) Adopted on 15 July GUIDELINES ADDRESSING ADDITIONAL ASPECTS TO THE NOx TECHNICAL CODE 2008 WITH REGARD TO

RESOLUTION MEPC.251(66) Adopted on 4 April 2014

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2" 8")

Zirconia Oxygen Probe

Pneum. Buoyancy Transmitter with Torque Tube for Liquid Level, Interface and Density

Volumeter. RMG Meßtechnik GmbH. Publication No E

GASEOUS FUELS SAFETY ASPECTS

AIRCRAFT PISTON ENGINE EMISSIONS. Appendix 1: Measurement System

Consistent implementation of the 2020 sulphur limit and work to further address GHG emissions from international shipping

System components for sample gas sampling

Viscosense 3. Viscosity Measurement & Control Systems. Product Bulletin TO BE REALLY SURE

Differential Pressure and Flow meters Accessories for the Media Series

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

IMO PREVENTION OF AIR POLLUTION FROM SHIPS. Report of the Working Group on Annex VI and the NOx Technical Code

Feed Pumps VP / VPB / VPBM

AGILENT ROTARY VANE PUMPS

MARPOL Annex VI Emission Control Areas. CDR Ryan Allain U.S. Coast Guard Environmental Standards Division Washington, D.C.

Desulphurizing Bunker Fuel/HFO Utilizing IUT Technology

SILOXA FAKA Gas Cleaning System

Test procedure and Specifications for Particle Number Portable Emissions Measurement Systems (PN-PEMS)

Technical Circular. No.: 025 Date: 6 th November 2014

Ammonia measurement challenges in SCR units

Desulphurizing Marine Fuel/HFO Utilizing IUT Technology. November 19, 2017 International Ultrasonic Technologies Inc.

Thermowell for temperature sensors omnigrad M TW 13

SIHI LPH-X - Liquid Ring Vacuum Pump Two Stage

C280-8 MARINE PROPULSION

CRNE AN-F-G-E-HQQE 3x HZ

T-Sense. Optical Torque Measuring systems. Product Bulletin TO BE REALLY SURE

MDT TIER III options with low sulphur fuels

MARINE ENGINE PERFORMANCE DATA [T2P PREFIX]

Product line : Marine

mass flowmeter for compressed air

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Metal tube variable area flowmeter for gases, liquids and steam

Technical Publication. Guidelines for the development of ship's Data Collection Plan (SEEMP Part II) /

RULES PUBLICATION NO. 98/P

RESEARCH ON INFLUENCE OF SELECTED FAILURES ON THE EXHAUST GAS CONTENT OF SHIP DIESEL ENGINE WORKING ON HEAVY FUEL OIL

Automatic Back-Flushing Filter AutoFilt RF9.

Transcription:

S-Keeper 7 MARINE APPROVED CEMS GREEN EFFICIENCY ON BOARD

S-Keeper 7 ARE YOU A SHIPOWNER OPERATING IN EMISSIONS CONTROL AREAS ECAs? IS INCREASING SHIP EFFICIENCY YOUR TARGET? ARE FUEL SAVINGS STILL AN ISSUE? THIS IS YOUR LIFERAFT. is a modular analysis system suitable for on-board continuous S-K7 emissions monitoring as per: MARPOL Annex VI Reg. 13 & 14 MEPC Circ. 471, 177(58), 184(59) IEC 60092-504 S-Keeper7 and certified as per: RINA Rules, Pt C, Ch 3, Sec 6 LLOYD Register Test Spec 1 DNV Standard for Certification 2.4 > S-K7 is simply the State of the Art of integrated analysis systems, fully compliant with applicable marine directives. > S-K7 is fully tailored to the Shipowner s requests with particular focus on CaPex & OpEx balance. > S-K7 is integrated with a modern PEM Propulsion Efficiency Monitor, thus encompassing metered Fuel Consumption, Fuel Oil Viscosity, Thrust and Torque measuring Systems. > Thanks to the specific engineering of this modular system, the S-K7 installation is able to withstand the toughest marine environment. > On-board maintenance is easy even for an unskilled operator, while the SPMP Spare Parts Management Program ensures the traceability of every single component and its availability on the ship s course. TECHNICAL DATA S-K7 OVERVIEW OF AVAILABLE FEATURES According to MARPOL Annex VI Reg.13 & MEPC 177(58), 184(59) > calculation of NOx g/kwh vs Tier I, Tier II, Tier III limits > monthly NOx compliance test report According to MARPOL Annex VI Reg.14 & MEPC 177(58), 184(59) > calculation SO2/CO2 ratio > calculation of Fuel Oil Sulphur content (% wt/wt) vs Reg.14 limits According to MEPC 177(58), 184(59) HC total Hydrocarbons load (ppm or g/kwh) is measured Reports according to ISO 14001 of totalized mass NOx / SOx / CO2 emissions (kg/tonne) Reports according to MEPC Circ. 471 of CO2 Emission Index (gco2 / tonne n.m.) Combustion Efficiency monitoring by CO2/(CO2+CO) ratio Types EASY-N, LITE-N, LITE designed for LNG powered units O2 (%) & Particulate (mg/m3 or g/kwh) analysis as additional options Multiple stack management S-K7 MAIN SUPPLY Qty#1 Integrated Cabinet Qty#1 Sample probe & tube Qty#1 Sample line Qty#1 Bottles set (according to analyzed components) S-K7 ANALYTICAL OPTIONS Qty#1 Oxygen Analyser Qty#1 Particulate Analyzer

S-K7 TECHNICAL SPECIFICATIONS Analyzed components measuring method > NOx, SO2, CO, CO2: NDIR (NO with NO2 to NO converter) > HC: H-FID heated flame ionization detector Auxiliary inputs Engine speed and Torque, Air inlet flow, Fuel flow, Ambient temperature, Pressure & Humidity sensors as per NOX Technical Code 2008, Ship GPS Global Positioning System Software > Windows -based Emissions Reporting software > Easy self-explaining graphical interface with Process Flow Diagram and real-time parameters > Multilevel Password Protection and Data Encryption to ensure safest tamperproof procedure I/O Connections 1 x Ethernet RJ45, 1 x RS-485, 1 x SPDT contact S-K7 SAMPLING SYSTEM Sample conditioning system According to NOX Technical Code 2008 with system condition monitoring and maintenance indicators Sample probe technical specifications > Operative Conditions: max. 200 kpa abs, 180 C > Filter element: Bonded Silicon Carbide (CSi) > Wetted parts: SS316Ti, CSi, Viton > Flanged Process Connection: DN 65 PN 6 DIN 2573 > Housing: SS304, IP43 rating Sample line technical specifications > Operative Temperature 190 C/Max 210 C/Peak 250 C > Maximum Operating Pressure 2.8 barg@200 C > Wetted parts PTFE material > External diameter 43 mm > End Caps diameters 48 mm > Minimum Allowable Bending Radius 200 mm > External insulation Fiberglass S-K7 OXYGEN ANALYSER (OPTION) Measurement method > Zirconium oxide Measurement range > 0 25 % (dry) Installation > Integrated in main cabinet S-K7 PARTICULATE ANALYSER (OPTION) Measurement method > Inductive Electrification Measured particle size > 0.3 μm or higher Measurement range > Lowest value 0.1 mg/m³ Installation > In-Situ, flanged to stack S-K7 AMBIENT CONDITIONS LIMITS Main Integrated Cabinet > Ambient Temperature +5 / +55 C; 95% RH Max Sample Probe > Ambient Temperature +5 / +55 C; 95% RH Max Particulate Analyser (option) > Ambient Temperature +5 / +55 C; 95% RH Max S-K7 UTILITIES CONSUMPTION Power supply 230 VAC @50/60 Hz Maximum power consumption (full model) 4.8 KVA Max Calibration gas bottle / each parameter 1 bottle 110 L @ 20 C / 1 operative year approx Demi water (only lite-s, lite, full models) 1 canister of 5 Liters / 3 operative months approx S-K7 DIMENSIONS & WEIGHT Main integrated cabinet 1050 x 1990 x 800 mm (WxHxD), 550 kg Sample probe Housing 251 x 297 x 168 mm (WxHxD), 9 kg, Length TBD Sample line Length TBD, 0.9 Kg/m Calibration bottle 360 (H) x 90 mm (DN), 1.1 kg Oxygen analyser (optional) Integrated in main cabinet Particulate analyser (optional) Flanged housing 342 (L) x 74 mm (DN), 1.7 kg, Insertion length TBD S-K7 SELECTION TABLE Type MARPOL Annex VI MEPC 177 (58) Analyzed Components Reg.13 Reg.14 184 (59) NOx CO2 SO2 CO HC Tier I/II/III Limits MEPC Circ. 471 ISO 14001 Analytical Options EASY-N O2, Particulate EASY-S O2, Particulate EASY O2, Particulate LITE-N O2, Particulate LITE-S O2, Particulate LITE O2, Particulate FULL O2, Particulate

LAYOUTS MAIN INTEGRATED CABINET RIGHT VIEW FRONT VIEW SAMPLE PROBE TBD 251 168 297 DN65 PN6 Flange DIN 2573 PARTICULATE ANALYSER (OPTION) TBD 232 16 326 130 Ø74 DN65 PN6 (DIN 2573)

S-K7 companions SLASHING EMISSIONS, REDUCING FUEL CONSUMPTION, MINIMIZING MAINTENANCE IN OTHER WORDS, SUSTAINABLE SHIP EFFICIENCY. HOW? HERE S OUR ANSWER. POSITIVE DISPLACEMENT METERS These liquid flow meters take accurate volumetric measurements for a wide range of liquids, from low-density LPG to fuel oil VISCOSITY IN LINE ANALYSERS The patented ViscoSense system is used for continuous in-line measurement and control of fuel oil viscosity & temperature for diesel engines on ships SHAFT POWER TORQUE & THRUST METER Using the TT-Sense for measuring thrust and torque results gives you an insight into your propeller efficiency, vessel pitch optimization and hull resistance PEM PROPULSION EFFICIENCY MONITOR The PEM4 is the first maritime solution for measuring propeller thrust, engine power and fuel consumption simultaneously OIL DISCHARGE MONITORING EQUIPMENT For the continuous on-line monitoring of discharge water during de-ballasting operations, the Oilcon Mark 6 is a proven solution known worldwide PRESSURE TRANSMITTERS The FCX AII V5 family with both aluminum and SS316 housings is simply the-state-of-the-art in pressure sensing for heavy-duty service FUJI ELECTRIC solutions are in continuous development, so we reserve the right to make product changes without prior notice DS_SK_SK7_MARINE APPROVED CONTINUOUS EMISSIONS MONITORING SYSTEM_DRAFT

Fuji Electric France S.A.S. 46 rue Georges Besse - ZI du brézet - 63039 Clermont ferrand Tél : 04 73 98 26 98 - Fax : 04 73 98 26 99 Mail : sales.dpt@fujielectric.fr - web : www.fujielectric.fr