YG101 SWING GATE OPENER OWNER S MANUAL

Similar documents
SKC400U SLIDING GATE OPENER OWNER S MANUAL

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Sliding Gate Operator User's Manual

Sliding Gate Operator User's Manual

SKC-500DC SLIDING GATE OPENER OWNER S MANUAL

Rolling Door Operator User s Manual

USER MANUAL. Automated Vehicular Boom Gate. Version: 1.0 Date: March, 2015

PY600AC Sliding Gate Opener User Manual

BARRY BARRIER GATE AUTOMATION

HATO 120 / 200 SECTIONAL DOOR OPERATOR USER S MANUAL HATO 120/200 SECTIONAL DOOR OPERATOR USER S MANUAL

OPENING THE WORLD SWING SWING GATE OPENER USER MANUAL

YG-5602/1U/E Swinging Gate Owner s Manual

Operating Instructions

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

Operating Instructions

WARNING GATE LOCK MODEL SGLOCK12V

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

SWING GATE OPENER SW300 SERIES

OWNER S MANUAL MODEL: PT 450 / PT 450M WELDING POSITIONER

Sectional and Tilting Door Opener Installation Instructions and User Guide

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

Sliding Gate Operator. User's Manual WARNING THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN

INSTALLATION INSTRUCTIONS

HIGH SPEED SLIDING GATE OPENER

Installation Manual. RW240/400/600 Motor Gearbox

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Instruction Manual for the. E-SL 450 Series

INSTALLATION INSTRUCTIONS

TMT Boxer 24v slider motor installation notes from EasyGate

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

Single or Double 240VAC motor control for domestic and industrial gates and doors.

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Table of Contents

INSTRUCTIONS FOR INSTALLATION

2 CHANNEL MULTI-PURPOSE RECEIVER

WIRING THE HEATER POWER SUPPLY

LINCE 300/400/600. User s and Intaller s manual

DYNEO Synchronous motors with permanent magnets-drive Commissioning

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Automation Swing Gate Opener

M-Series 415 & in 1 Elevator Light Curtain. Installation Manual

INSTALLATION INSTRUCTIONS

R3 Roller Garage Door Opener

Sectional And Tilting Door Opener

TEL: G&C Electronics CC E. T.

Installation Instructions

Training & Didactic Systems. Fundamentals of Electrical Engineering

Roll Up Door Operator

DOOR LIMITS A) ENGAGE CHAIN/BELT CONNECTOR TO CARRIAGE CAUTION B) CLOSE TRAVEL LIMIT

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

INSTALLATION INSTRUCTIONS

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

The House of Gate Automation

ELSEMA 240VAC Slider Control Board, SLD

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Operating Instructions Type MPT 53

APOLLO Gate Operators, Inc.

INSTALLATION INSTRUCTIONS

FM SECURITY AND REMOTE START SYSTEM

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

INSTALLATION INSTRUCTIONS

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

RAMSET

Installing the gate post bracket with the cardboard arm template

Easy Tool Retracting System SR2159

INSTALLATION INSTRUCTIONS

WESCO INDUSTRIAL PRODUCTS, INC. Heavy Duty Semi Electric Pallet Truck. Part Number:

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

NYOTA 115. Electro-mechanical sliding gate operator. Instruction manual

Application Engineering

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

INSTALLATION INSTRUCTIONS

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

INSTALLATION INSTRUCTIONS

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

3 Phase Smart Controller

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Instructions For PG-1200RC Magnetic Locking Devices

INSTALLATION INSTRUCTIONS

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

K001A6039. Control Board Replacement Kit WARNING INSTALLATION INSTRUCTIONS APPLICATION REQUIREMENTS: FUNCTION: REMOVE EXISTING BOARD

Gate & Door Controller with LCD and Intelligent Technology

12V Central Lock Universal Remote For Keyless Entry p/n

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

PRELIMINARY INSTALLATION INSTRUCTIONS. Remote Engine Starter Attachment Kit P/N 08E92-SNA-100B

COOKSON OWNER'S MANUAL

User Guide. Model Insulation Tester / Megohmmeter

AUTOMATIC CONTROL ROLLING DOOR OPENER

Sectional and Tilting Door Opener Installation Instructions and User Guide

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

OPERATOR SHAFT-120. Installation and Operating Manual CONTENTS GENERAL INFORMATION SAFETY INSTRUCTIONS OPERATOR UNIT OPERATOR INSTALLATION

KVM 25 OPERATION MANUAL / INSTALLER

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

INSTALLATION INSTRUCTIONS

Transcription:

YG101 SWING GATE OPENER OWNER S MANUAL

IMPORTANT SAFTEY INFORMATION Installing the YG101 Gate Opener requires wiring of standard 110V electrical lines. This should only be performed by a trained technician. Mis-wiring could cause personal injury or DEATH. To prevent the risk of electrocution, be sure to turn off all power to the YG101 until installation is complete. The YG101 model gate opener is for a double-sided gate. The length of each section of the gate can be no greater than 6.5 feet for this opener to operate properly. Do not attempt to use this gate opener with a gate length greater than 6.5 feet (2 meters). The maximum force that the gate opener can provide is 1500N. An electric lock is provided for installation for gate lengths greater than 5 feet (1.5 meters). In the event of power failure, an emergency release key allows you to operate the gate manually (for gate lengths greater than 5 feet [1.5 meters], it is recommended that you unlock the electric lock). The gate can be opened or closed in manual mode. ADDITIONAL FEATURES An interface for an optional keypad is available on the control board. User may add additional remote controllers to operate the gate opener. This gate opener includes emergency stop and reverse functions if it senses an obstruction. This feature MUST be tuned prior to operation. Be sure to follow the directions in the section on Tuning the Auto Reverse prior to operational use. Specifications Power Supply AC 110V±10%V, 60Hz Motor Speed 1680 rpm Motor Output 100W Opening Time <26 seconds Working Angle of Gate 90 or 105 Max. Gate Section Weight 330 lbs. (150kg) Max. Gate Section Width 6.5 feet (2 meters) Duty Cycle 25% Noise <65dB(A) Emergency Release Key in Case of Power Failure

Parts List 1 Hood pipe 22 24T ring gear 2 End joint 23 Locating shield 3 Pin 10x40 24 Motor 4 Steel tube 25 Capacitor bracket 5 Small support ring 26 Capacitor 6 Right housing 27 Wiring base 7 Screw M5x20 28 Wiring terminal 7A Locknut 29 Screw M4x8 8 Screw shaft 30 Wiring cover 9 Connect socket 31 Tapping screw 9A Split ring 32 Joint block 10 Tapping screw 33 Axle pin 11 Outer tube 34 Earth wire 12 Large support ring 35 Release key 13 Bearing 6004 36 Lock 14 Pin 8x35 37 Seal 17X2.65 15 27T ring gear 38 Upper cover 16 Planetary gear 39 Screw 4.2x9.5 17 Central gear 40 Waterproof seal 18 Pin 4x20 41 Hexagonal nut 19 Seal 13.2x2.65 42 Light housing 20 Square gasket 43 Waterproof seal 21 Spring

Parts Diagram 6 7 25 5 26 27 2 3 4 24 28 29 30 31 32 23 33 1 12 13 14 18 19 17 16 15 21 20 43 42 22 34 10 11 41 9 9A 40 39 38 37 36 35 8 7A

Installation Main Structure Fig.1 Special motor Planetary reducer Screw shaft Control box The installation height range is 1.18 3.15 inches (300 800mm). See Fig. 2 Fig.2 Gate pillar Gate opener Gate Electric lock

One of the first decisions that should be made is if this installation is a push to open or a pull to open. In either configuration, the gate is mounted on one face of the mounting post, and the opener is mounted on face 90 degrees from it. Below are schematics of both push to open and pull to open configurations. Retainer (close position) Gate opener Enlarge Retainer (open position)

When the opener is installed, the installation angle should be >0. See Fig. 3. The baseboard should be fixed to the pillar of the building. See Fig. 3 Enlarge. Fig. 3 Retainer (close position) 110 A B Cmax Á 140 125 50 90 ã 130 115 50 105 ã B Á 1020 A Gate opener Enlarge Cmax Retainer (open position) >0 ã

Front and Rear Parts of Gate Opener To install the rear part of the gate opener, insert shoulder screw and spacer, then tighten with the nut. See Fig. 4. Fig. 4 Shoulder screw Rear part of gate opener Support bracket Spacer Nut To install the front part, fit the hole in the front part with the hole in the supporting plate, and push the axle pin into the holes (using hands or a hammer), and finally fit the retainer clip. See Fig.5. Fig. 5 Supporting plate Axle pin Front part of gate opener Retainer clip

Wiring Screw off the two stainless tapping screws, then remove the cover and wiring as shown in Fig. 6. WARNING: Follow the wiring diagram precisely. Failure to do so could cause damage to the gate opener controller. Fig. 6 Stainless tapping screw Upper cover U V W M Enlarge Hood Shield Install the hood pipe, tighten the screws into the opener and cover the hood shield over the joint. See Fig. 7. Fig. 7 Main unit Scew Hood pipe pipe Hood shield

Waterproof caps There are 8 caps in total 4 to be used and 4 spares. When the gate opener is installed, the caps are used to cover the upper holes of the unit to avoid leakage. See Fig. 8. Fig. 8 Waterproof cap Gate opener Retainer Closed and Opened Positions Close the gate section to its fully closed position, fix the retainer according to the position of the gate section. NOTE: Each section is completed separately. See Fig. 3. If the maximum angle for installing is 105, the retainer should be installed on the ground at approx. 100. If the installing angle is 90, the retainer should be installed at 90. See Fig. 3. Electric Lock If the gate section is >5 feet (1.5 meters), it is recommended that you install the electric lock. Weld the steel plate of the lock to the gate, and then fix the lock. See Fig. 9 to determine height of the plate.

Fig. 9 A Release here Electric lock Base plate To install the base plate of the lock, fix the plate to the ground with 3 screws and make sure that the lockpin can fit tightly in the hole in the plate. Adjustment The pair of gate sections will not start simultaneously. The gate section without the lock will start earlier than the other gate section, so that both sections can be locked properly. Maintenance and Electrical Check the screw lubricant and add 1# grease regularly. Keep opener clean at all times. The XF24B control box is designed for the YG101 Swing Gate Opener. Its main technical parameters are as follow:

o Power Supply: AC 110V o Environmental Temperature: 14 F ~ 104 F (-10 C ~ +40 C) o Motor: AC 110V, max. power 735W o Electronic Lock: DC 12V 2A o Operating Time: 20 seconds ~ 100 seconds o Relay Coil Voltage: DC 12V, SCM power supply: DC 5V o Weight of Control Box: 4.4. lbs. (2Kg) Main Function o Radio control, the receiver can receive hopping code (frequency: 433.92MHz). o The gate will auto-reverse when it contacts obstruction. o Auto-close function can be selected to close the gate automatically after delay time. o It can control single-gate or dual-gate. Safety Instructions o The gate opener s hould be installed by a qualified technician; otherwise, serious personal injury or property damage may occur. o Before installation, all the locks of the gate should be removed or unlocked. o The auto-reverse function must be checked during installation to ensure that the gate can auto-reverse in the event of obstruction. o This auto-reverse function should be regularly inspected and adjusted, if necessary. o When opening or closing the gate, DO NOT attempt to walk or drive through the gate. o DO NOT touch the gate while it is in operation. o The opener should be switched off before repairing it or opening its cover. o Please erase and reset the code after installing the opener. Installation o Remove the cover of the control box, remove the control board and fix the control box on the wall, perform the wiring and cover again. Connect L to power line, N to neutral, and E to earth wire. Adjustment of the Auto-Reverse Function o Tuning the auto-reverse safety function: Rotate the Force Adj. Knob with a screwdriver. The resistance may be increased or decreased by rotating clockwise or counterclockwise. If the gate can be removed freely, the adjustment of obstruction force is completed. NOTE: If the gate fails to reverse in the event of obstruction. Then, the opening force or closing force should be checked for conformity with requirements, and adjusted, if necessary. The gate will reverse if obstructed when closing and will stop if jammed when opening. Learn/Erase Remote Controls o Press red learn button on the control board, then the LED will turn on. It will turn off when you press any button on the transmitter. Press

the same button and the LED will flash at 2Hz frequency. If it fails to learn, the LED will turn off automatically after flashing for 1 second. o To erase all remote controls, press and hold the red button on the control board until the LED stops flashing. After 1 second, it will flash again. This indicates that the remote controls have been erased completely. Install the External Keypad/Button Switch (See Table 3) o The port GND is the common port, the port K is used to open the gate, G is used to close the gate, and T is used to stop the gate. Note : If the gate running direction is not correct, please change wires V1 and W1 or V2 and W2. If the wiring between two gates is wrong and the gates cannot work, please check the wiring between U1, V1, W1 and U2, V2, W2. Fig. 10 Control Board

Table1: Wring Notes of Control Board No. Interface function Remark 1 Transformer output AC12V 2 Transformer input AC110V 3 Fuse 5 20 2A 4 Adjusting knob (for No.1 gate which has electrical lock) 5 Adjusting knob (for No.2 gate) 6 Antenna Impedance: 50O 7 Power indicator light 1206 8 Indicator light 1206 9 Learn button 6 6 10 Mode switch See table 2 11 External button interface See table 3 12 External device interface See table 3 13 Electrical lock interface DC12V 14 Alarm lamp interface AC110V The resistance may be increased or decreased by rotating clockwise or anticlockwise. The resistance may be increased or decreased by rotating clockwise or anticlockwise. 15 Capacitance interface of No 2 motor Suitable for No 2 motor 16 No 2 motor interface See table 4 17 Capacitance interface of No 1 motor Suitable for No 1 motor 18 No 1 motor interface See table 4 19 Fuse 5 20 10A 20 Power supply AC110V 21 Buzzer It will ring if the gate is jammed.

Table2: Mode Switch No. Position Remark 1 ON Single- gate OFF Dual - gate 2 ON Single- gate: for No.1 gate OFF Single -gate: for No.2 gate 3 ON Dual - gate: first open last close OFF Dual - gate: two gates open or close at the same time 4 ON Enables auto-close OFF Disables auto-close 5 ON For swing gate OFF For sliding gate 6 ON Working time is 60s OFF Working time is 90s 7 ON Single button OFF Three buttons for remote controller 8 ON OFF NOTE: Be sure the factory preset of bit 3 and bit 5 of the mode switch is ON, please DO NOT adjust it. Table 3: Wiring terminal for external button / external device No. Tag Remark 1 12V Output +12V 100mA 2 GND Ground 3 IC N.O. 4 IR Infrared N.C. 5 LD Loop-detector interface 6 5V Output +5V 100mA 7 K External button: Open 8 G External button: Close 9 T External button: Stop Table 4: Connection between control board and operator No. Tag Remark 1 U1 No.1 motor: COM/U 2 V1 No.1 motor: V 3 W1 No.1 motor: W 4 U2 No.2 motor: COM/U 5 V2 No.2 motor: V 6 W2 No.2 motor: W

Gatekeeper Ltd. PO Box 752 Laceys Spring, AL 35754 info@gatekeeperltd.com 2005-2007 GatekeeperLtd All Rights Reserved