This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

Similar documents
Internal Accessories. Electronic Bell Alarm - Display Module Relay. Electronic Bell Alarm or Display Module Relay

PD-Series Ground Fault Circuit Protection

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

www. ElectricalPartManuals. com Instructions for Field Testing of Ground Fault Systems Utilizing Cutler-Hammer Magnum DS Circuit Breakers

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

CENTERLINE 2100 Motor Control Centers

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SB Encased Systems Breakers, Trip Units and Accessories. Selection and Application Guide October 1, 1999

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

SURE-TRIP OEM RELACEMENT TRIP UNIT

Critical Power Switchboards. Selection and Application Guide

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

POWERLINE 2000 Energy Management System TM

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

SB Encased Systems Breakers, Trip Units and Accessories. Pricing Guide Effective: September 9, 2002 (Consult Siemens for Pricing after 10/01/03)

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

SURE TRIP RETRO KITS

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

MODEL 422 Submersible Pump Controller

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Product Specification Sheet #3LD2.1

Table of Contents. For latest version, visit:

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

White Paper. Ground Fault Application Guide. WL Low Voltage Power Circuit Breakers

Model (Circuit Tester) Model (GFCI Tester)

design prefix 50 Hanover Road, Florham Park, New Jersey USA (ASCO), for service call (ASCO)

Tmax Molded Case Circuit Breakers

Electromagnetic Industries LLP

TOTALFLOW Technical Bulletin 82

Service Entrance Methods

Electrical network protection VIP30, VIP35. User s manual 12/2008

Products :: Circuit Protection :: Thermal Circuit Breakers

Bolted contact switches. Pringle switches

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to range before servicing, unless testing requires power.

TIMER INTERFACE USER MANUAL

TRW Commercial Steering Diagnostic Tool

SIEMENS. Microprocessor-Based Tripping System. Static lrip III. www. ElectricalPartManuals. com

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Selective Coordination Enforcement:

Owner s Manual. Series 165 Automatic Transfer Switches rated 100 and 200 amps, single phase, 240 V ac for automatic 2 wire start generators

Selective Coordination

Motor Protection With The MonitorPro

ibusway for Data Center

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

This Specification Data Sheet brought to you by: Trinity Blvd. Fort Worth, Texas /

with Electronic Trip Units

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

5. OVERCURRENT RELEASE (OCR)

PB-Series. GFCI/ELCI & Panel Seal

Digitrip RMS and Digitrip OPTIM Trip Units Used with R-Frame Circuit Breakers

SERIES VAC Microprocessor Based Direct Spark Ignition Control with Combustion Blower Relay FEATURES DESCRIPTION

Low-Peak 600V Class RK1

Thermal-magnetic Miniature Circuit Breaker 4230-T...

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

TIME REQUIREMENT GUIDE (TRG)

Electronic Circuit Breaker ESS20-0..

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

Transfer Switch TS-50. Owner s Manual

Advanced Torque Products

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

N-frame Circuit Breaker

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Technical information No. 01. IT systems. The basis for reliable power supply

SAX Electronic Valve Actuator

Tmax Molded Case Circuit Breakers

Contents Getting Started with PrePass ELD...4 Starting a Trip...7 During a Trip Co-Driver Features... 14

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

F-Series. Circuit Breaker

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

A. Submit manufacturer's literature and technical data before starting work.

Florham Park, NJ USA Call (ASCO) for sales or service

For Options, Modifications and Accessories, see pages Discount Schedule A6

F-Series. Circuit Breaker

General Purpose US Fuses

ITS-50R TRANSFER SWITCH OWNER S MANUAL

EPS-ECONOMY PUMP STARTER

Transfer Switch GPTS 30

Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Installation, Operation and Maintenance Manual

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Transcription:

This Specification Data Sheet brought to you by: 15825 Trinity Blvd. Fort Worth, Teas 76155 817/465-9494 equipment@technicaldiagnostic.com www.technicaldiagnostic.com www.test-equipment-rental.com The attached material is copyrighted by and will remain the property of the individual manufacturers. Technical Diagnostic Services is providing this information at no charge as a service to our customers.

Time Current Curve - 800A and A Frame Sizes Long Time/Instantaneous Protection Configuration 22

Time Current Curve - 800A and A Frame Sizes Long Time/Short Time (Fied Delay) Protection Configuration 23

Time Current Curve - 800A and A Frame Sizes Long Time/Short Time (I 2 t Delay) Protection Configuration 24

Time Current Curve - 800A and A Frame Sizes Long Time/Short Time (Fied Delay)/Instantaneous Protection Configuration 25

Time Current Curve - 800A and A Frame Sizes Long Time/Short Time (I 2 t Delay) /Instantaneous Protection Configuration 26

Time Current Curve - 4000A Frame Size Long Time/Instantaneous Protection Configuration 27

Time Current Curve - 4000A Frame Sizes Long Time/Short Time (Fied) Delay Protection Configuration 28

Time Current Curve - 4000A Frame Size Long Time/Short Time (I 2 t Delay) Protection Configuration 29

Time Current Curve - 4000A Frame Sizes Long Time/Short Time (Fied Delay)/Instantaneous Protection Configuration 30

Time Current Curve - 4000A Frame Size Long Time/Short Time (I 2 t Delay) Instantaneous Protection Configuration 31

Time Current Curve - 400A, 800A, 1200A, A Frame Ratings Ground Fault Protection 32

Time Current Curve - A and 2500A Frame Ratings Ground Fault Protection 33

Time Current Curve - 3200A and 4000A Frame Ratings Ground Fault Protection 34

Accessories Auilliary Power Module (APM) Plug-in Power Supply for bench testing of the Electronic Trip Unit for Siemens Type SB Systems Breaker Display Module Current monitoring Display Module, see page 21. 35

Accessory - Universal Test Kit (TS-31 ) D. Type in the catalog number and then press the ENTER key. The catalog number can be found on the nameplate of the circuit breaker. The TS-31 will respond with: Searching Catalog... Searching Family Series... If an invalid catalog number has been entered, the TS- 31 will respond with: Not Found. Press Enter to Continue and you will be asked to enter another catalog number. E. If valid catalog number has been entered, the TS-31 will prompt for the Breaker switch settings. The TS-31 will respond with: Enter continuous current setting in % Enter instantaneous pickup setting. Enter long time delay in seconds. For breakers with short time functions you may be asked one of the following: Enter short time Pickup. Universal Test Kit The TS-31 is used to test the operation of the fault protection functions of the Type SB Electronic Trip Unit. It has been designed to be user friendly The user is prompted by the TS- 31, in a step-by-step format, as to the required input information and test instruction. The test results are visually displayed to the user. NOTE: Utilize individual instructions supplied with Test Kit for Type SB Encased Circuit Breaker testing. CAUTION: Before conducting a Trip test on a circuit breaker which is Closed and in service, caution should be taken to evaluate effects on downstream loads. The breaker will open during testing, resulting in a disruption of service and possible erroneous readings might occur due to the effect of a systems load. Operating Instructions A Remove electrical loads from circuit breaker. B. Plug the TS-31 test set into a grounded 120 VAC receptacle and turn it on. You will be greeted by the identifying turn-on message: 36 Siemens Energy & Automation, Inc. TS-31 Test Set. Press ENTER to continue C. Select the appropriate ribbon cable assembly and connect it between the TS-31 and the circuit breaker, making sure of alignment and polarity. After pressing ENTER, the TS-31 will prompt: Enter Select Short Time Delay: 1-Fied 2-1 2 t Enter short time delay in seconds Enter 1 2 t delay in seconds. For breakers with ground fault you will be asked: Enter ground fault pickup setting in % Enter ground fault delay in seconds In each case, enter your breaker s switch settings. For eample if your breaker is set for a continuous current of 70%, type 70 and then press enter. Entry of erroneous data in the above steps will result in false tests and results. F. After entering the breaker switch setting you must select the test you wish to perform. The TS-31 will request: Enter test to perform; see instructions. Type in one of the following letters depending upon the test you wish to perform: L - Long time or overload test, S - Short time test, I - Instantaneous test. G - Ground fault test, C - Current transformer continuity test, G. The TS-31 will report the type of test you selected and give you a chance to abort the test. For eample, if I was pressed above. The TS-31 will display: Instantaneous Test Press ENTER to continue or A to abort If you pressed the letter A to abort, you will be asked again:

Accessory - Universal Test Kit (TS-31 ) Enter Test to perform H. If you press ENTER, you will be prompted for the phase to test: The TS-31 will display: Enter phase to test. Enter one of the following letters: A - Phase A or left pole. B - Phase B or center pole. C - Phase C or right pole. I. Press Enter again to start the test. Press any other key to STOP the test. Once a test has been started, the TS- 31 will respond with: Testing. Be careful at this time. Any key press will abort the test. CAUTION: Handling of the test cable, the breaker, or the trip unit at this time can cause electric shock which may result in injury and/or death. J. The test may take anywhere from a fraction of a second to minutes to complete, depending on which procedure was run. If the test passes, the display will show the following. depending on whether the breaker tripped or not. Passed Test. seconds Press ENTER to continue. If the circuit breaker tripped during the test, RESET the circuit breaker before continuing. K. The TS-31 will prompt for the net instructions. The display will show: Change: 1 - Test 2 - Catalog 3 - Settings Enter one of the following numbers: 1 - Select a new test 2 - Enter a new catalog number 3 - Enter new switch settings If you enter 1 you will be sent to step F. Choosing a 2 will send the program back to step C and entering a 3 will route program control back to step E. Entering 3 which sends you back to step E, will be slightly different the second time through. On the second line after the prompt for the setting, a number or tet in angle brackets will appear. This will indicate the last setting you entered. If you DON T wish to change a setting, just press ENTER. If you DO wish to change a setting, type in the new setting and press ENTER. L. If you pressed C when asked Enter test to perform; see instructions you will first be prompted by, Current Transformer Test Press ENTER to continue or A to abort, and then by the phase to test. One of the following messages will then appear depending on the test results: CT Resistance Test. Phase X Passed Press ENTER to eit test and continue CT Resistance Test. Phase X Failed Press ENTER to eit test and continue CT Resistance Test. Phase X Open Press ENTER to eit test and continue CT Resistance Test. Phase X Short Press ENTER to eit test and continue The Phase X Failed message indicates that the CT resistance is neither open nor shorted, but is not within design tolerance. M. There are additional ERROR messages which may appear on the display during this operation which were not covered previously: Test Not Running! Check test cable connection Press ENTER to continue. The test set has sensed that current is not f owing properly in the breaker under test and that there is either an open or short circuit between the TS-31 and the breaker trip unit. Function Not Available Press ENTER to continue You will get this error message if you enter a choice that is not available, such as entering G in step F for ground fault test on a catalog number that does not have ground fault. Inconclusive Test, check settings Press ENTER to continue or A to abort NOTE: This warning will appear if you attempt to run a short time test with the instantaneous pickup set equal to or below the short time pickup. It would also appear if you tried to run a long time test with short time pickup set to 2. This is only a warning: the test can still be run. However, passing or failing the test may not be conclusive. Invalid Input Press Enter to continue NOTE: NOTE: NOTE: This message will appear if you enter a setting value that does not eist. For eample, a Type SB Electronic Trip Unit has continuous current settings of 50, 60, 65, 70, 75, 80, 85, 90, 95, and 100 percent. If you enter any other value than those listed, the above message will appear. Test eceeds capability of TS-31 Press ENTER to continue This message is not likely to occur. If it does, it means that a test requires more current to run than the TS-31 can produce. Unit too hot! please wait Running many successive high-current long time tests may over-heat the test set. It will protect itself from damage by preventing further tests until it has had a chance to cool down. The display will indicate when testing can resume. 37

38 Ordering Information Electronic Trip Unit 4000A Frame Size Frame Ampere Rating Continuous Current Setting Long Time Delay Short Time Pickup/Delay Instantaneous Pickup Ground Fault Pickup/Delay SB25TLI SB25TLS SB25TLSI 2500 2500 2500 SB25TLIG SB25TLSG SB25TLSIG 2500 2500 2500 SB32TLI SB32TLS SB32TLSI 3200 3200 3200 SB32TLIG SB32TLSG SB32TLSIG 3200 3200 3200 SB40TLI SB40TLS SB40TLSI 4000 4000 4000 SB40TLIG SB40TLSG SB40TLSIG 4000 4000 4000 Electronic Trip Unit 800A Frame Size Catalog Number Frame Ampere Rating Continuous Current Setting Long Time Delay Short Time Pickup/Delay Instantaneous Pickup Ground Fault Pickup/Delay SB04TLI SB04TLS SB04TLSI 400 400 400 SB04TLIG SB04TLSG SB04TLSIG 400 400 400 SB08TLI SB08TLS SB08TLSI 800 800 800 SB08TLIG SB08TLSG SB08TLSIG 800 800 800 Electronic Trip Unit A Frame Size Catalog Number Frame Ampere Rating Continuous Current Setting Long Time Delay Short Time Pickup/Delay Instantaneous Pickup Ground Fault Pickup/Delay SB12TLI SB12TLS SB12TLSI 1200 1200 1200 SB12TLIG SB12TLSG SB12TLSIG 1200 1200 1200 SB16TLI SB16TLS SB16TLSI SB16TLIG SB16TLSG SB16TLSIG SB20TLI SB20TLS SB20TLSI SB20TLIG SB20TLSG SB20TLSIG

Ordering Information Rating Plugs 400A Frame Ampere Rating Rating Plugs 2500A Frame Ampere Rating Plug Rating Plug Rating 04SB200 04SB225 04SB250 200 225 250 25SB 25SB 25SB2500 2500 04SB300 04SB350 04SB400 300 350 400 Rating Plugs 3200A Frame Ampere Rating Rating Plugs 800A Frame Ampere Rating 08SB400 08SB450 08SB500 Plug Rating 400 450 500 32SB 32SB 32SB2500 32SB3000 32SB3200 Plug Rating 2500 3000 3200 08SB600 08SB700 08SB800 600 700 800 Rating Plugs 4000A Frame Ampere Rating Plug Rating Rating Plugs 1200A Frame Ampere Rating Plug Rating 40SB 40SB2500 40SB3000 2500 3000 12SB600 12SB700 12SB800 600 700 800 40SB3200 40SB4000 3200 4000 12SB1000 12SB1200 1000 1200 Rating Plugs A Frame Ampere Rating 16SB800 16SB1000 16SB1200 16SB Plug Rating 800 1000 1200 Rating Plugs A Frame Ampere Rating Other Items Item Universal Test Set Auilliary Power Module Display Module Neutral Transformers Frame Ampere Rating 400 800 TS-31 SBAPM SBDM N04SB N08SB 20SB1000 20SB1200 20SB 20SB Plug Rating 1000 1200 1200 2500 3200 4000 N12SB N16SB N20SB N25SB N32SB N40SB 39

UL Listings and File Numbers Trip Unit & Breaker Accessories Drawout CSA E9896 E57501 E135453 LR57039 40

Siemens Energy & Automation, Inc. 3333 State Bridge Rd. Alpharetta, GA 30202 Bulletin 2.20-3A (New) 1991 Siemens Energy & Automation, Inc. SIEMENS is a registered trademark of Siemens AG