2/2- way directional valve type URZS40 Cover of directional valve type ULZS40

2/2 - way cartridge valve type URZS/S

WK Proportional pressure reducing valve, cartridge design type WZRS6. NS 6 up to 5 MPa up to 40. dm /min APPLICATION DESCRIPTION OF OPERATION

3-way flow control valve type UDUE10 is intended for

Directional cartridge valve tight on both sides type 2URED6 3

Directional spool valve type WH16 hydraulically operated

Directional control valves hydraulically operated type WHG6/WHP6

Double throttle/check valve type Z2FS16

Directional cartridge valve type. tight on both sides type 2URED6

X 7 WK Electrically operated directional spool valve with a soft-shift function type WE6P NUAL NS6. up to 35 MPa up to 80 dm APPLICATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 16 COVER FOR CARTRIDGE VALVE TYPE ULZS 16. size 16 up to 42 MPa 140 dm 3 /min DESCRIPTION OF OPERATION

Pilot operated pressure relief valve type DB 3

Pressure relief valve, pilot operated, sandwich plate type UZPR10

Direct operated pressure relief valve type DBD

2-WAY FLOW CONTROL VALVE TYPE UDRD6

6-way section directional valves type 6URRE6 consist

6-way section directional valves type 6URRE6

Power pack type UHMZ 63

Power pack type UHPT

Power pack type UHJV 250

Power pack type UHJV 63

Power pack type UHKZ

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

6/2 way directional valve type 6/2UREM6 and 6/2URMM6

Check valve, pilot operated

Directional spool valve type WMM 16 hand lever operated

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

PILOT OPERATED PRESSURE RELIEF VALVE TYPE DB/DBW

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Power pack type UHMZ 25

HYDRAULIC PILOT CONTROL UNIT OF SANDWICH PLATE DESIGN

Flow control valve. Rectifier plate. Type 2FRM5,10,16. Type Z4S5, 10, 16 01/ Sizes 5, 10 and 16 Up to 315 bar Up to 160 L/min

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Filling valve sandwich plate

Pilot operated check valve

Pilot operated pressure relief valve

Electrically operated directional spool valve with a soft-shift function type WE10P NS 10. up to 35 MPa up to 120 DATA SHEET - OPERATION MANUAL

Proportional pressure reducing valve type 3WZCDE6 is a

Proportional pressure reducing valve

Check valve cartridge Type M-SR

Double throttle/check valve type Z2FS10

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

Pressure limitation and feed valve, pilot-operated Type MHDBN...Y

Check valve, pilot operated

Safety cartridge valves with poppet position monitoring

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Check valve, pilot operated

Pressure reducing valve, pilot operated Type DR

RC /

2-way flow control valve

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

Pressure relief valve, pilot operated

Check-Q-meter type FD

Check valve, pilot operated

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

2-way cartridge valve, actively controllable. Type LC2A. Features. Contents. RE Edition: Replaces:

3/2-Way Valve DN 15 up to DN 40

Electrically controlled directional control poppet valve type UREZ6

Check valve, pilot operated

Throttle and throttle check valve

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

Open center control block in mono block design MO-16, 22, 32

Pressure sequence valve pilot operated

High Flow Cartridge Valves 2/2 Way Series NG16 NG100

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31

Proportional pressure reducing valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

Pressure relief and feed valve, pilot operated. Type MHDBN. Features. Contents. RE Edition: Replaces:

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

Pilot control unit with end position lock for the remote control of directional valves

VPN1-06. Functional Description HA /2008. Pilot Operated Pressure Relief Valves. Replaces HA /2002

ISO cartridge valves type LIDEW* and LIDBH*

Throttle and throttle check valve

Pressure relief valve, pilot operated

RSP 7-06 R S P FUNCTIONAL DESCRIPTION ORDERING CODE. DIRECTIONAL CONTROL VALVES KE /13 D n 06 p max 32 MPa Q max 80 dm 3 /min

3/2-Way Valve DN 15 up to DN 50

Angle Seat Valve 7010

3-way Proportional pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated

VPP2-04. Functional Description HA /2003. Directly operated pressure relief valves. Replaces HA /2002

Flow sharing control block in mono block / sandwich plate design M6-15

Double throttle/check valve type Z2FS6

Flow sharing control block in sandwich plate design M7-25

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)

VRN2-10. Functional Description HA /2008. Pilot Operated Pressure Reducing Valves. Replaces HA /2003

Flow sharing control block in mono block / sandwich plate design M6-22

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

Hydraulic Motor (Radial piston multi-stroke)

Size 6 10 up to 31.5 MPa up to 120L/min

Proportional pressure relief valve, directly operated, rising characteristic curve

Double throttle check valve Type Z2FS 10

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Pressure shut-off valve pilot operated, type DA/DAW...50B/(New Series) Huade América 1

2/2 Logic Cartridge Valve, Size 10

Transcription:

Valve cover with a function of controlling closed position of the valve poppet type ULZS ED NS6, 5 up to 0 MPa up to 00 dm /min DT SHEET - OPER RTION MNU NUL WK 6 60 0.07 PPLICTION The valve cover with a function of controlling the closed position of the valve poppet type ULZS ED ED with a valve cartridge version URZS D can be used in hydraulic systems as a pilot-operated check valve, pressure reducing valve and by a combination of several elements as a multi-way control system. DESCRIPTION OF OPERTION The valve cover with a function of controlling the closed position of the valve poppet type ULZS ED ED consists of the valve body () with control bores, inductive poppet position sensor (), nozzle () and valve cartridge version URZS D - the main elements include: bushing, poppet with a damping nose (5), spring (6). The poppet is pressed against the valve seat in the bushing () by means of the spring (6). The flow is possible in both directions: from to and the opposite direction, from to. The valve poppet (5) has steps. They are three surfaces important for its operation. The surface of the seat is considered a 00%. The ring surface was created by gradation of the valve poppet (5), it is, depending on the version, 7% or 50% of the surface. The relation of the : surfaces is therefore,: or :. The surface is equal to + and can amount to 07% or 50% of the surface. The surface remains the same. y changing the ring surface, the actual size of the considered as 00% also changes. The valve opens in both directions of flow if there is no pressure affecting the surface (the connection remains without pressure) and the force of the pressure affecting respectively the or surfaces is greater than the force of the spring (6). If the surface is affected by the controlling pressure, it presses the valve poppet (5) against the valve seat in the bushing () independently from the force of the spring (6). Opening of the valve can take place by unloading the surface or by adequately high pressure at the connection, or else. The nozzle () in the controlling channel makes it possible to choose the type and time of the opening. The position sensor () allows for monitoring the closed position of the poppet (5), voltage states at the output pins of the sensor () depending on the poppet stroke (5) - see the diagram at page. ULZS5ED - 0/05DM 5 6 (00%) (7%/ 50%) (07% / 50%) Type ULZS ED - - WK 660 0.07

TECHNICL DT Hydraulic fluid Maxim imum operat ating pressure at portp orts s,, Maxim imum flow f rater Weight Maxim imum load curre c urrent of f the t sensor Connection type of the sensor mineral oil Required fluid f clec leanline ness classc ISO 06 class c 0/8/5 Nominal fluid viscosity o 7 mm /s at temperature 55 C Viscosity range,8 up to 80 mm /s o o recommended 0 C up to 55 C Fluid temperature range (in a tank) max -0 o C up to +70 o C mbient temperature range - 0 o Cup to +50 o C up to t 0 MPa NS6 NS5 NS6 NS5 Poppet position sensor inductive sensor type M Type of position sensor a sensor with two alternative outputs type PNP Supp upply volt ltage rang r of f the t sensor V DC +0% -0% up to t 0 dm /mi min up to t 00 0 dm /mi min,6 kg,9 kg 00 0 m external thread M x ; polep les (pins) INSTLLTION ND OPERTION REQUIREMENTS. Only fully functional and operational valve cover in a set with a fitted during assembly, factory sensor and valve cartridge can be used.. During operation one must keep proper viscosity of the hydraulic fluid recommended in this Data Sheet Operation Manual.. In order to provide failure-free free and safe operation of the valve cover,, one should systematically check: condition of electrical connection operation of the valve cover cleanliness of the hydraulic fluid. Due to heating of the valve cover body to high temperature, the valve cover should be placed in such a way as to eliminate a possibility of accidental contact with the valve cover body during operation or one should provide suitable covers compliant with the requirements of European standards: s PN - EN ISO 7 - and PN - EN. 5. In order to provide tightness of the valve cover connection to the hydraulic system, one should keep the dimensions of the cavity, sealing rings, tightening torques and operation parameters of the valve cover specified in this Data Sheet - Operation Manual. 6. ny changes, modifications or adjustments a to the valve cover can be made only by the producer see notes at pages and 5. 7. person operating the valve cover must be thoroughly familiar with the e content of this Data Sheet - Operation Manual. WK 6 60 0.07 - - Type ULZS ED

DIGRMS Hydraulic diagrd agram ams of f complete valve ve covers c type ULZS...ED... U wit ith valve ve cartrc artriges - version URZS...D... version ULZS...ED.../...DM... vers ersion ULZS...ED.../...DM... ULZS...ED.../...M... ULZS...ED.../...M... URZS...D...D... URZS...D... vers ersion ULZS...ED.../...DM... vers ersion ULZS...ED.../...DM... ULZS...ED.../...M... URZS...D... ULZS...ED.../...M... URZS...D... Electr lectric ical l connectc nection n diagrd agram am of f the t ind nduct uctive sensor type M PNP contact allocation - pin configuration of the sensor connection Outpu tput t state ates of f the t sesnsor type M depending ng on the posit p ition of f the t valve ve poppetp poppet stroke output state of the sensor 0 0 pin pin 0 flow through damping nose flow 0 - off neutral state on output contact - on state on output contact PERFORMNCE CURVES o measured at viscosity ν = mm /s and temperature t = 50 C Flow resist stance curc urves charactericstics p (Q) for valve cartridges - version URZS6...D... - acc. to data sheet WK 50 950 charactericstics p (Q) for valve cartridges - version URZS5...D... - acc. to data sheet WK 50 Type ULZS ED - - WK 660 0.07

OVERLL ND CONNECTION DIMENSIONS valve ve cover c - version ULZS6ED... O9 M x 7 detail 5 8 0,5 6 O 6 O5 depth 9 M8 x 0 screws 5 56 9 counterbores O9 holes 9 O6 O0 - holes O5 O,5 0,5 - Sealing ringo-rin -ring 9,5 x,78 - pcs /set () - Sealing ringo-rin -ring 0, x, - pcs /set - Sealing ringo-rin -ring 7, x, - pcs /set - Sealing ringo-rin -ring 6 x - pcs /set 5 - Spec. back-up ring 6-060 - pcs /set 6 - Fixing screwsm8 x 0-0.9 acc. topn - EN ISO 76 pcs /set; included in delivery set; tightening torque Md = Nm 7 - Overall dimension* of the valve cover - version ULZS6ED... (without sensor plug - item 8) 8 - Inductive sensor of valve poppet position typem (sensor plug not shown on the drawing, delivered on separate order acc. to data sheet WK 99 96 - order code: 76-0058990) 9 - Valve cartridgewit ith a poppet p and damp d amping nose - versions:urzs6...d...;...d... included in delivery set NOTE: (*) - Required additional distance for sensor plug - item 8 and electric wire ~ 70 mm 65 = = 6 65 6 NOTES: complete valve cover - version ULZS6ED with a valve poppet position sensor type M and valve cartridge - versions: URZS6 D ; D is factory pre-set. ny changes. modifications or adjustments to the cover can be done only by the producer. components of the set ULZS6ED cannot be changeable/used in other sets; in case of damaging the sensor, cover or cartridge, one must replace the whole cover. Type ULZS ED - - WK 660 0.07

OVERLL ND CONNECTION DIMENSIONS valve ve cover c - version ULZS5ED... O9 M x 7 detail 8 0,5 5 5 O0 depth counterbores O holes 6 O 9 0 O6 M x 50 screws 0 7 9 O O5 - holes O5 9 6 - Sealing ringo-rin -ring 9,5 x,78 - pcs /set () - Sealing ringo-rin -ring 8, x - pcs /set - Sealing ringo-rin -ring 9, x - pcs /set - Sealing ringo-rin -ring 6, x - pcs /set 5 - Spec. back-up ring 6-0590 - pcs /set 6 - Fixing screws M x 50-0.9 acc. topn - EN ISO 76 pcs /set; included in delivery set; tightening torque Md = 80 Nm 7 - Overall dimension* of the valve cover - version ULZS5ED... (without sensor plug - item 8) 8 - Inductive sensor of valve poppet position typem (sensor plug not shown on the drawing, delivered on separate order acc. to data sheet WK 99 96 - order code: 76-0058990) 9 - Valve cartridgewit ith a poppet p and damp d amping nose - versions:urzs5...d...;...d... included in delivery set NOTE: (*) - Required additional distance for sensor plug - item 8 and electric wire ~ 70 mm 85 Type ULZS ED - 5 - WK 660 0.07 = = 9 58 85 58 NOTES: complete valve cover - version ULZS5 5ED ED with a valve poppet position sensor type M and valve cartridge - versions: URZS5 5 D ; D is factory pre-set. ny changes. modifications or adjustments to the cover can be done only by the producer. components of the set ULZS5 5ED ED cannot be changeable/used in other sets; in case of damaging the sensor, cover or cartridge, one must replace the whole cover.

OVERLL ND CONNECTION DIMENSIONS valve ve covers c cavit c itie ies s type ULZS...E..ED... acc. to t DIN ISO 768 nom ominal sizes NS6, 5 n 0,,5 OD H7 5 Y H7 fitting depth 0,6,5 H H u0, OD,5,5 5 H6 H5 fitting depth H u0, H +0, H8 OD H depth 0,5 OD OD H7 L u0, L u0, Z ^ 0,05 D6 depth H - holes OD5 (max) - holes (, Y, Z, Z) L L u0, L u0, Y L u0, L u0, L u0, L Z L u0, NS φd φd φd φd φd φd5 D6 H H H H H H5 H6 H7 H8 6 5 6 6 M8 56 0 0 5 5 5 6 6 6 M 7 58 0 0,5,5,5 NS L L L L L 6 65 6 5 0,5 5 85 58 9 6 WK 6 60 0.07-6 - Type ULZS ED

HOW TO ORDER ULZS Nominal size of the cover (NS) NS6 = 6 NS5 = 5 ED D M * Type of cover with a function of electronic control of the closed position = ED Series number (00-09) - connection and installation dimensions unchanged = 0 series 0 = 0 Surface relation (:- acc. to page ) : (50%) =, : (7%) = Cracking pressure 0,05 MPa =05 0,0 MPa =0 0,0 MPa =0 0,0 MPa =0 Valve poppet with a damping nose =D Closed position control valve poppet position sensor type M Control channel without nozzle with a nozzle (diameter specified in the next step) = M = no designation = Nozzle diameter φ 0,5 mm = 05 φ0,6 mm = 06 φ0,7 mm = 07 φ0,8 mm = 08 φ,0 mm = 0 φ, mm = φ,5 mm = 5 φ,8 mm = 8 φ,0 mm = 0 φ,5 mm = 5 φ,0 mm = 0 φ,5 mm = 5 φ,0 mm = 0 Sealing NR (for fluids on mineral oil base) FKM (for fluids on phosphate ester base) = no designation = V Further requirements in clear text (to be agreed with the manufacturer) NOTES: The valve cover should be ordered according to the above coding. The symbols in bold are the preferred versions in short delivery time. Coding example: ULZS6 ED - 0/ 0 D M WK 6 60 0.07-7 - Type ULZS ED

PONR Wadowice S.. ul. Wojska Polskiego 9-00 Wadowice tel. +8 88 00 fax.+8 88 0 www.ponar-wadowice.pl WK 6 60 0.07-8 - Type ULZS ED