D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

Similar documents
Hinged Safety Door Switch

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Safety-door Switch. Ordering Information

Manual Reset Limit Switch

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Safety-door Switch D4NS. Model Number Structure. Model Number Legend

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4B-N. uce. Safety Limit Switch. Positive Action Limit Switches with Direct Drive Contacts for Critical Switching Applications

Safety Limit Switch

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D4NS. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Safety-door Switch. Model Number Structure

D4BS CSM_D4BS_DS_E_8_4

Model Number Structure

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

D4GL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key

Small Limit Switch D4V

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Safety Limit Switch

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

Inductive Proximity Sensor

D4GS-N CSM_D4GS-N_DS_E_7_2

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

2NC (slow-action) Direct. Model. opening

Multiple Limit Switch

D4NH CSM_D4NH_DS_E_7_1

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Subminiature Basic Switch

Multiple Plunger Limit Switch

D4BL. Guard Lock Safety-door Switch

D4NL. Model Number Structure. Guard Lock Safety-door Switch. Model Number Legend. Switch. Operation Key \ Lead-free, Environment-friendly Design

CSM_D4N-_R_DS_E_6_1

Features. Guard Lock Safety-door Switch D4JL. World's Top* Holding Force of 3,000 N *For plastic models, as of May 2005

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

D4NS/D4NS-SK. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Nextgeneration. Model Number Structure. Model Number Legend

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

2NC (slow-action) Direct. Model. opening

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D4NL. Guard Lock Safety-door Switch. Best-selling Guard Lock Safety-door Switch Available in Several Compact, Multi-contact Models

F3S-TGR-KM15/-KM16/-KH16

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Inductive Proximity Sensor

Switching Power Supply

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

Model Number Structure

A4EG. Enabling Grip Switch. Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions. Ordering Information

Safety Switches & Operator Controls

D4BL. Guard Lock Safety-door Switch

Model Number Structure

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Model Number Structure

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

D4JL. Guard Lock Safety-door Switch. World's Top * Holding Force of 3,000 N. Features

Compact plastic limit switches with positive opening mechanism

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

DL (AZD1) Mini Limit Switches

Pre-wired Models D4C- (1) (2) (3) (4)

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

HS1E Series Full Size Solenoid Locking Switches

A22NK. Key-type Selector Switches

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

Compact plastic limit switches with positive opening mechanism

Cylindrical Proximity Sensor

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

Miniaturized limit switches

Transcription:

Compact Interlock Safety Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors Positive opening mechanism and double insulation approved by TÜV and BIA. Five-direction Operation Key. Approved by UL, CSA, BIA, and SUVA standards. Enclosure ratings: IP65 (EN60529), Type 4 (UL/CSA) (indoor use only). Refer to Precautions on page 9. Approval: Agency Standard File No. TÜV EN60947-5-1 R9551708 Rheinland (positive opening) UL (see note) UL508 CSA C22.2 No.14 E76675 BIA GS-ET-15, EN60947-5-1 1-conduit: 9509915 2-conduit: 9509913 SUVA SUVA 1-conduit: Nr.6010Z 2-conduit: Nr.6011Z CSA C22.2 No. 14 compliance was verified and approved by UL (Marked with C UL ). Conformity: Machine Directive Low-voltage Directive pren1088 1

Ordering Information Model Number Legend: Switches - 1 2 3 4 Operation Key -K 1 1. Conduit 1: Pg13.5 (1-conduit) 2: G1/2 (1-conduit) 3: 1/2-14NPT (1-conduit) 5: Pg13.5 (2-conduit) 6: G1/2 (2-conduit) 2. Built-in Switch 5: 1NC/1NO (Slow-action) A: 2NC (Slow-action) 3. Head Mounting Direction F: Front-side mounting 4. Head Variation S: Standard 1. Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (horizontally adjustable) Note that any order for the head part or the switch part alone cannot be accepted. The Operation Key is sold separately. Type Conduit size 1NC/1NO (Slow-action) 2NC (Slow-action) Positive opening Model Positive opening Model 1-conduit Pg13.5-15FS -1AFS G1/2-25FS -2AFS 1/2-14NPT -35FS -3AFS 2-conduit Pg13.5-55FS -5AFS G1/2-65FS -6AFS Accessories (Order Separately) Operation Key Horizontal Mounting type -K1 Model Vertical -K2 Adjustable (horizontal) -K3 2

Specifications Ratings Applicable Standards TÜV and BIA (EN60947-5-1) Utilization category Rated operating current (I e ) Rated operating voltage (U e ) AC-15 2 A 400 V UL (UL508/CSA C22.2 No.14) A600 Rated voltage Current Voltage Ampere Continuous Make Break Make Break 120 VAC 10 A 60 A 6 A 7,200 VA 720 VA 240 VAC 30 A 3 A 480 VAC 15 A 1.5 A 600 VAC 12 A 1.2 A General Rated voltage Non-inductive load Inductive load Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO 125 VAC 10 A 3 A 1.5 A 10 A 5 A 2.5 A 250 VAC 10 A 2 A 1 A 10 A 3 A 1.5 A 400 VAC 10 A 1.5 A 0.8 A 3 A 1.5 A 0.8 A 8 VDC 10 A 6 A 3 A 10 A 6 A 14 VDC 10 A 6 A 3 A 10 A 6 A 30 VDC 6 A 4 A 3 A 6 A 4 A 125 VDC 0.8 A 0.2 A 0.2 A 0.8 A 0.2 A 250 VDC 0.4 A 0.1 A 0.1 A 0.4 A 0.1 A The above current ratings are for a steady-state current. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). Lamp load has an inrush current of 10 times the steady-state current. Motor load has an inrush current of 6 times the steady-state current. 3

Characteristics Operating speed Contact gap Operating frequency Insulation resistance Contact resistance Dielectric strength Rated insulation voltage (U i ) Switching overvoltage Pollution degree (operating environment) Short-circuit protective device (SCPD) Conditional short-circuit current Conventional enclosed thermal current (I the ) Protection against electric shock Vibration resistance Shock resistance Life expectancy (see note 1) 0.1 m/s to 0.5 m/s 2 x 2 mm min. 30 operations/min 100 MΩ min. (at 500 VDC) between terminals of same polarity, between terminals of different polarity, between each terminal and ground, and between each terminal and non-current-carrying metal part 25 mω max. (initial value) U imp 4 kv between terminals of same polarity, between terminals of different polarity, between each terminal and ground, and between each terminal and non-current-carrying metal part (EN60947-5-1) 400 V (EN60947-5-1) 1,500 V max. (EN60947-5-1) 3 (EN60947-5-1) 10 A, fuse type gi or gg (IEC269) 100 A (EN60947-5-1) 10 A (EN60947-5-1) Class II (double insulation) Malfunction: 10 to 500 Hz, 0.65-mm single amplitude with an imposed acceleration of 100 m/s 2 (10G) max. Destruction: 1,000 m/s 2 min. (approx. 100G min.) Malfunction: 300 m/s 2 min. (approx. 30G min.) Mechanical: 1,000,000 operations min. Electrical: 150,000 operations min. Ambient temperature Operating: 30 C to 70 C (with no icing) Ambient humidity Operating: 95% max. Enclosure rating (see note 2) Weight IP65 (EN60947-5-1) Approx. 76 g (for -15FS) The above mechanical life and electrical life are possible when the ambient temperature is 5 C to 55 C and the ambient humidity is 40% to 70%. Although the Switch casing resists dust, oil, and water, make sure that the keyhole on the head is free from dust, oil, water, and chemical, otherwise the may wear out, break, or malfunction. Operating Characteristics Operating force (extraction) Release force (insertion) Pretravel Total travel (reference value) Min. positive opening force (see note) Min. positive opening stroke (see note) 29.42 N (3,000 gf) 14.71 N (1,500 gf) 6±3 mm 28 mm 58.84 N (6,000 gf) 10 mm Make sure that the positive opening stroke is at least 10 mm in order to use the safely. 4

Nomenclature Operation Key The dedicated key prevents operational mistakes and forcibly separates the contacts. Head The head can be mounted in four directions. The Operation Key can be inserted in five directions including the downward direction. Oil Seal The plunger has an O ring. The switch casing ensures IP65 (except the keyhole, which ensures IP00). Use the in places where the keyhole is free from oil and metal chips. Built-in Switch Has a positive opening mechanism which forcibly separates the NC contacts even if they are welded. The built-in switch incorporates a pair each of NC contacts and NO contacts or two pairs of NC contacts. Cover The cover, with a hinge on its lower part, can be opened by removing the screw of the cover, which ensures ease of maintenance and wiring. Conduit Wide switch variations. Pg13.5: 1-conduit, 2-conduit models G1/2: 1-conduit, 2-conduit models 1/2-14NPT: 1-conduit models The housing and head of the are made of synthetic resin. If high mechanical durability is required, use the D4BS Safety Door Switch. 5

Operation Contact Form Model Contact Diagrams Remarks - 5 S 1NC/1NO Zb Only NC contacts 11 and 12 have an 11 to 12 11 12 approved positive opening 23 to 24 mechanism. 23 24 Stroke Insertion position Fully-drawn position ON - A S 2NC 11 21 Zb 12 22 11 to 12 21 to 22 Stroke NC contacts 11, 12, 21, and 22 have an approved positive opening mechanism. Insertion position Fully-drawn position ON Terminals are numbered according to EN50013 and contacts are marked according to EN60947-5-1. Positive Opening Mechanism 1NC/1NO Contact (Slow-action) 2NC Contact (Slow-action) Fixed contact (NC) Fixed contact (NC) Contact spring Movable contact Contact spring Movable contact Return spring Fixed contact (NO) Return spring Plunger Plunger Only the NC contacts have a positive opening function. When metal deposition occurs, the contacts are separated from each other by pushing in the plunger. Conforms to EN60947-5-1 Positive Opening Both NC contacts incorporate a positive opening function. When metal deposition occurs, the contacts are separated from each other by pushing in the plunger. Conforms to EN60947-5-1 Positive Opening The switches are marked with indicating approval for the positive opening mechanism. 6

Dimensions All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. The conduit thread varies with the model as follows: Pg13.5 Conduit thread Model -1 S/-5 S G1/2-2 S/-6 S 1/2-14NPT 1-conduit Models -1 S -2 S -3 S -3 S 30 x 30 R2.15±0.05 mounting holes Two, 4 +0.15 0 dia. holes depth: 5 See note 3 on page 7. 2-conduit Models -5 S -6 S 30 x 30 R2.15±0.05 mounting holes Cap 56 max. See note 3 on page 7. Two, 4 +0.15 0 dia. holes depth: 5 Operation Keys -K1 -K2 -K3 Four, R2.15 Four, R2.15 9 dia. 4.5 dia. 8 dia. 7

With Operation Key Inserted -1 S + -K1-2 S + -K1-3 S + -K1-5 S + -K1-6 S + -K1 44 to 46.5 Key insertion face Horizontal key insertion radius R 200-1 S + -K2-2 S + -K2-3 S + -K2-5 S + -K2-6 S + -K2 44 to 46.5 Key insertion face Horizontal key insertion radius R 200 44 to 46.5 Key insertion face Permissible difference in center lines between the Operation Key and key hole. Vertical key insertion radius R 200 44 to 46.5 Key insertion face Permissible difference in center lines between the Operation Key and key hole. Vertical key insertion radius R 200 Permissible difference in center lines between the Operation Key and key hole. Permissible difference in center lines between the Operation Key and key hole. -1 S + -K3-2 S + -K3-3 S + -K3-5 S + -K3-6 S + -K3 44 to 46.5 Key insertion face Horizontal key insertion radius R 200 44 to 46.5 Key insertion face Permissible difference in center lines between the Operation Key and key hole. Vertical key insertion radius R 200 Permissible difference in center lines between the Operation Key and key hole. 8

Precautions Warnings Force imposition! WARNING Do not remove the operation key from the door, or insert it to the switch with the door open. Machine may start operating. Do not disassemble or touch inside under power-on. Electrical shock hazard may be caused. Do not use metal connector or conduit with this switch. Electrical shock hazard may be caused. Install the operation key so that it will not hit the operator when the door is open. Injury may be caused. NOTICE Protect the with an appropriate cover and post a warning sign near the, otherwise the or Operation Key may be removed carelessly and may result in serious injury due to the unexpected operation of the machine To prevent the from damage due to short-circuits, connect the in series to a fuse that has a breaking current 1.5 to 2 times the rated current of the. If the is used under EN-approved rating conditions, use a 10 A fuse type gi or gg conforming to IEC 269. Do not touch the live switch terminal. Electric shock may be caused. Be sure to evaluate the Switch under actual working conditions after installation. Use OMRON s D4BS Switch under conditions requiring more robustness, sealing ability, and oil-tightness. Operating Environment The is for indoor use only. Do not use the outdoors. Otherwise, the may malfunction. Operation Key Be sure to use the dedicated Operation Key only. Do not operate the with anything other than the dedicated Operation Key. Otherwise, the safety of the system may not be maintained. Do not impose excessive force on the Operation Key inserted into the or drop the with the Operation Key inserted. Otherwise, the Operation Key may be deformed or broken. Dropping Secure the Operation Key with a one-way screw, or an equivalent, so that the Operation Key cannot be easily removed. Mounting When applying the to the door of a machine room, be sure to provide a stopper for the door as shown in the following illustration. Do not use the Switch as a stopper. Adjust the mounting position of the Operation Key so that the Operation Key will be within the 3-mm lock range of the when the door is closed (i.e., the distance (a) in the following illustration is within 3 mm). Switch Stopper Refer to page 7 for the mounting dimensions of the Operation Key. Be sure that the Operation Key can be inserted properly with a tolerance of ±1 mm in the upward, downward, left, or right direction, otherwise the may be damaged. ±1 min. ±1 min. 9

Tightening Torque Be sure to tighten each screw of the properly, otherwise the may malfunction. 5 3 Mounting Be sure the that operates properly after mounting and adjusting the. Switch Mounting Holes The Switch and Operation Key are fastened to the specified torque (on page 10) with M4 screws (one-way screw etc.) and washers. Mounting Holes/Studs 1-conduit 1 4 2 6 2-conduit 4 0.05 0.15 dia. height, 4.8 max. 7 4 0.05 0.15 dia. height, 4.8 max. Type 1 Terminal screw (M3.5) 2 Cover mounting screw 3 Head mounting screw 4 Body mounting screw (M4) (see note) 5 Operation Key mounting screw 6 Connector at conduit opening Proper tightening torque 0.59 to 0.78 N m (6 to 8 kgf cm/0.43 to 0.58 ft lbf) 0.78 to 0.88 N m (8 to 9 kgf cm/0.58 to 0.65 ft lbf) 0.78 to 0.88 N m (8 to 9 kgf cm/0.58 to 0.65 ft lbf) 0.49 to 0.69 N m (5 to 7 kgf cm/0.36 to 0.51 ft lbf) 2.35 to 2.75 N m (24 to 28 kgf cm/1.73 to 2.03 ft lbf) 1.77 to 2.16 N m (18 to 22 kgf cm/1.30 to 1.59 ft lbf) 7 Cap screw 1.27 to 1.67 N m (13 to 17 kgf cm/0.94 to 1.23 ft lbf) Tighten each screw together with a washer to the specified torque. Operation Key Mounting Holes Mounting hole Mounting surface Horizontal/Vertical Mounting (-K1/-K2) Adjustable Mounting (-K3) Hole for protruding part 4 0.05 0.15 dia. height, 4.8 max. Two, M4 Two, M4 Head Direction By removing the four screws of the head, the mounting direction of the head can be changed. The head can be mounted in four directions. When changing the direction of the head, be sure that the Operation Key is inserted into the head and no foreign material will enter during a change in direction. 10

Do not remove any internal screw from the head, otherwise the internal parts of the head may become lost or deformed. Wiring Do not connect lead wires directly to the terminals. Be sure to connect the lead wires through insulation tubes and crimp terminals. The tightening torque applied to each crimp terminal is 0.59 to 0.78 N m (6 to 8 kgf cm). The lead wires must be an AWB20 to AWG14 type (i.e., 0.5 to 2.5 mm 2 thick). dz dia.: 3.7 D dia.: 4.5 B: 7.0 L: 20.2 F: 7.7 I: 9.0 (mm) D dia. Maintenance and Repairs Users must not repair or maintain the. Contact your OMRON representative for any repairs or maintenance. Others Be sure that no metal dust, oil, or chemical will be sprayed onto the, otherwise the may malfunction. The head uses grease internally, which may have a bad influence on semiconductor products. When using the for the door of a semiconductor product manufacturing room, mount the to the outer side of the door. dz dia. Wire the crimp terminal as shown in the following diagram so that it will not come in contact with the case or cover. Correct Terminal screw Incorrect Crimp terminal Conduit Opening The torque required to tighten a connector other than a 1/2-14NPT connector is 1.77 to 2.16 N m (18 to 22 kgf cm). The torque required to tighten a 1/2-14NPT connector is 1.37 to 1.77 N m (14 to 18 kgf cm). The casing may be damaged if an excessive tightening torque is applied. For the casing to maintain IP65, apply sealing tape between the connector and conduit opening. Be sure that the diameter of the cable connected to the connector is correct. When wiring a 2-conduit model, attach and tighten a conduit cap to the unused conduit opening. The torque to be applied to the conduit cap is 1.27 to 1.67 N m (13 to 17 kgf cm). The conduit cap is provided with the. Recommended Connectors Size Manufacturer Model Cable diameter G 1 / 2 OMRON SC-6 7.5 to 9.0 mm LAPP ST-PF1/2 6.0 to 12.0 mm 5380-1002 Ohm Denki OA-W1609 7.0 to 9.0 mm Pg13.5 LAPP ST13.5 5.0 to 12.0 mm 5301-5030 HEYCO 3216 4.3 to 11.9 mm 1 / 2-14NPT LAPP ST-NPT1/2 6.0 to 12.0 mm 5301-6030 HEYCO 3231 4.3 to 11.9 mm LAPP is a German manufacturer. Ohm Denki is a Japanese manufacturer. HEYCO is an American manufacturer. 11

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. C104-E1-2 OMRON Corporation Control Components Division H.Q. 28th Fl., Crystal Tower Bldg. 1-2-27, Shiromi, Chuo-ku, Osaka 540 Japan Phone: 06-949-6115 Fax: 06-949-6134 In the interest of product improvement, specifications are subject to change without notice. Printed in Japan 0897-1M (0696) a 12