Automatic Recirculation Valves One Step Centrifugal Pump Minimum Flow Protection

Similar documents
Automatic Recirculation Valves PUMPENSCHUTZVENTILE

Yarway Hy-Drop Throttling valve

Series TD. Type TDL Type TDM. Automatic Recirculation Valve for pump protection

Series TD. Type TDL Type TDM. Automatic Recirculation Valve for pump protection

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

A self-contained system, the 7100 Series ARC valve has a pressure reducing trim and is in-line repairable.

YARWAY THROTTLING VALVES HY-DROP MODEL 5817/ 5827

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

Series MRK and MRM For nominal pressures up to 640 bar /class 4500 Automatic Recirculation Valve for pump protection

Series MRM/MRK For nominal pressures up to 640 bar /4500 lbs Automatic Recirculation Valve for pump protection

A self-contained system, the 7100 Series ARC valve has a pressure reducing trim and is in-line repairable.

Specially designed low-maintenance control valves for a wide range of applications in water circulation

Series SUL Automatic Recirculation Valve for pump protection

YARWAY ARC PUMP PROTECTION VALVES (AUTOMATIC RECIRCULATION) SERIES 9200, 9100, 5300 AND BPR

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

Minuteman Vertical Pumps

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

SECTION Pressure & Temperature Control

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

SPECIALTY CONTROL VALVES FOR UREA PLANTS

NARVIK-YARWAY. High Pressure Level Gauges, Model: 17

SECTION H4 BOILERMATE DEAERATORS

SECTION H3 TRAYMASTER SERIES DEAERATORS

78200/18200 Series LINCOLNLOG Valves Anti-cavitation High Pressure Control Valves

Save Thousands of Dollars Per Year!

LIQUEFIED GAS PUMP INSTALLATION

GÝROL FLUID DRIVES GÝROL FLUID DRIVES SAVE ENERGY HOW GÝROL FLUID DRIVES WORK

brands you trust. CRANE - Cast Steel Valves

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 SEPTEMBER 2001

Table of Contents. 1900/P3 Series Exposed spring design - The spring in this design is exposed for atmospheric cooling. D through T orifice sizes.

Waterous S100 Single Stage Pump

SEMPELL TURBINE BYPASS VALVE MODEL 115 CHP

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

SV80H Safety and Relief Valves

RS Multi-Stage, Ring Section Pumps

Standard Duty A.T.-Temp Desuperheater for cryogenic processes

STEAM TURBINE BY-PASS AND STEAM CONDITIONING VALVE

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

Designed to provide maximum service life with minimum maintenance.

DBO(Y)(S)-3 CONTROL VALVE SIZES 2" 8" ANSI CLASS 125/250, 150/300, 600

PumPs. jacketed molten sulfur PumPs. Pumps Mixers Strainers Engineered Systems and Controls.

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 APRIL 2004

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

VB VALVES & AUTOMATION

Components of Hydronic Systems

SAMPLE SPECIFICATIONS

Kunkle Bailey 756 safety relief valve

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

Installation, Operation and Maintenance Instructions

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

AEGIS RSS Series. Fully Lined Bellows Sealed Control Valves. RSS Series

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

YARWAY BLOW-OFF VALVES SEATLESS, HARDSEAT AND UNIT TANDEM

Fisher CAV4 Control Valve

Yarway Narvik Model 37 and 47 Cryogenic injector

What is the future of control valve technology?

Fisher DFA Variable Geometry Desuperheater

Series Direct contact, metal-to-metal seating, make the globe valve ideal for most shut-off applications. Features

barmesapumps.com VERTICAL MULTI-STAGE PUMP PERFORMANCE CURVE NOMENCLATURE B M V

Fisher RSS Lined Globe Valve

Fisher CAV4 Control Valve

BOSS Series D Control Valve

Crispin Valves Operating Guide. Crispin

Fisher RSS Lined Globe Valve

CROSBY STYLE JB PRESSURE RELIEF VALVE

M&H AWWA C508 STANDARD SWING CHECK VALVES

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

Boiler Feed Booster Pump YNK. Type Series Booklet

DVG/AF Variable Geometry Desuperheater

NELES TRUNNION MOUNTED BALL VALVE SERIES D

Contents. Identification

Jordan Control Valve Series

CUSTOM COMBINATION AIR VALVE

CENTRIFUGAL PUMP AND SEAL (API Std. 610 and 682) Presented By Prakash Kumar ME(NSPL)

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

SICCA SCC Type Series Booklet

Yarway 7100 Series ARC Valve non-filtered design Installation and maintenance instructions

M&H AWWA C508 STANDARD SWING CHECK VALVES

CONTROL VALVE STANDARD SPECIFICATION

Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves

PF6 Stainless Steel Piston Actuated On/ Off Valves

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

TempLowHT Steam Desuperheater Model: 59/69/79

ENGINEERING STANDARD FOR MACHINERY PIPING

TECHNICAL BULLETIN. Valtek Multi-Z Anti-Cavitation Control Valve. Experience In Motion. Valtek Series Multi-Z FCD VLENTB /10

SERVICE & OPERATING MANUAL

SchuF Fetterolf Control Valves REGELVENTILE

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Double door, spring loaded, wafer check valve designed to protect your gas or liquid piping systems.

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

TABLE OF CONTENTS INDRODUCTION

AN ISO 9001:2008 CERTIFIED COMPANY. Safety Valve

SUGGESTED SPECIFICATIONS

CAST STEEL FLANGED GATE, GLOBE, & CHECK VALVES.

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Multi Orifice Nozzle. Valve (MON) R Series Control Valves R2 R3 R4 R6 R8

Transcription:

Automatic Recirculation s One Step Centrifugal Pump Minimum Flow Protection HPM Series ENGINEERINGInc. Portage Avenue, Three Rivers, MI USA Phone: -7- Fax: -78-7

Centrifugal Pumps Require Protection If you use centrifugal pumps for any liquid-boiler feed water, condensate, or process fluids, a significant investment has been made in the pump, driver and related controls. Minimum flow protection is vital upon pump start up and low demand conditions. If reliable protection does not exist, the following unfavorable effects can interfere with the performance and reliable operation of the pump. The liquid s temperature will rise due to friction and hydraulic losses within the pump. Figure a illustrates the temperature rise in relationship to the H-Q curve. The curve indicates that at or near the best efficiency point, the temperature rise is minimal and not significant to the pump operation. The process flow removes the generated heat from the pump. The temperature increases as the flow through the pump is reduced. Frictional and hydraulic losses generate heat, while the quantity of fluid to which this heat is transmitted is reduced. The rise in temperature results in the formation of vapor. The elevated temperature / vapor pressure of the liquid results in problems ranging from damaged seals and bearings to complete failure of the rotating element. Internal recirculation within the pump, often termed incipient recirculation, can cause a form of cavitation leading to impeller damage. Internal recirculation is illustrated in Figures b and c. High specific speed pumps have power curves which rise as the flow reduces. If adequate flow is not maintained, motor overload will result. Internal recirculation occurs within this operating area Head Minimum Flow for Thermal Protection H-Q Curve Capacity Minimum Flow for Stable Operation Figure b 8 Pumping Temperature: F Specific Gravity:. H-Q Curve Entering Flow Recirculating Flow Total Head (ft.) 8 Temperature Rise Temperature Rise ( F) Capacity (GPM) 7 Typical characteristic curve of a multistage centrifugal pump illustrating temperature rise versus capacity. Pump impeller section illustrating the recirculation of liquid at the inlet during operation at low flows. Figure a Figure c

Minumum Flow Protection Methods Centrifugal pumps can be protected by one of three methods: Continuous Recirculating System The desired minimum flow volume is recirculated regardless of the system demand for fluid. Fixed orifices reduce the pressure before discharging. Continuous recirculating provides reliable pump protection, however, it is very inefficient and costly. The pump and driver must be sized to allow for the additional flow that is recirculating even when the flow demand rate exceeds the required minimum flow. See Figure a. Instrument Controlled System Recirculating occurs only when the process flow demand drops below the required minimum flow rate. Instrument controlled systems eliminate the inefficient and costly to operate constant recirculating systems. However, the necessary system components; check valve, flow meter, pressure reducing valve and related piping result in a considerable expense to purchase, install and maintain. See Figure b. HBE Automatic Recirculating s The automatic recirculating valve performs all flow sensing, bypass pressure reduction, reverse flow protection and modulating recirculating flow in an integral three port valve. The valve performs the same function of an instrumented system without the multitude of components, piping connections and system design expense. The valve is flow operated and does not require any air or electricity to operate. See Figure c. To Process To Process To Process Control Bypass Pressure Breakdown Orifice Fluid Source Control Bypass Control Breakdown Orifice Solenoid Fluid Source Control HBE Engineering Combination Recirculation and Check Anti-Flash Fluid Source FIC Check Check Flow Meter Pump Pump Pump Continuous Recirculation System (very wasteful of energy) Figure a Conventional Multi-Component System (many components to install and maintain) Figure b HBE Engineering System (simple, energy efficient and reliable) Figure c

HBE HPM Automatic Recirculation ANSI Class - Introduction The HPM Series Automatic Recirculation was developed for high pressure centrifugal pump protection. Popular applications include boiler feed water, petroleum fluids, and steel mill hot strip descale water. The HPM provides economical and reliable protection against low and reverse flow. By combining the functions of main line check valve, flow sensing element, bypass flow control, bypass pressure reduction, pulsation dampener and bypass line check valve, the valve eliminates at least seven components necessary with a conventional system. The valve operates without air or electric power and is easily installed with three connections. Principle of Operation The valve is installed on or close to the pump discharge, just as an ordinary check valve would be. Upon pump startup and without process demand, the bypass is completely open, recirculating the necessary minimum flow. Once process demand starts, the spring loaded disc is lifted and held in position by flow demand. Until main flow demand exceeds recommended minimum flow, the valve will modulate. As the main flow demand increases beyond recommended minimum flow, the bypass will close and all flow will go to the process. One Many Functions The HPM Series Automatic Recirculation is the one valve that provides at least five essential functions. Following are those functions:. Check Disc prevents reverse flow and positions the bypass for open, closed or modulating flow by detecting the process flow demand.. Bypass modulates open when main flow demand falls below the recommended minimum pump flow. Multiple stage pressure reduction prevents flashing/cavitation.. Flow Straightener eliminates turbulent discharge. Fluid exits valve as a spray rather than a jet. Reduces erosive wear on downstream piping.. Integral Pulsation Dampener protects system from waterhammer if sudden changes in flow demand occur.. Integral Check in bypass prevents reverse flow when bypass is routed into a common return line.

Materials of Construction Pos. 7 8 7 8 Description Lower Body Upper Body Stem Guide Guide Bolt Spring Check Liner Bypass Branch Vortex Housing Control Head Vortex Plug Lever Pivot Pin Vortex Bushing Piston Vortex Plate Flow Straightener Guide Pin Stud Stud Hex Nut Hex Nut Material Specification A Carbon Steel ASME A A Carbon Steel ASME A A Carbon Steel ASME A ASTM A 8 AISI ASTM A 8 ASTM A 7 A Carbon Steel ASME A ASTM A 8 ASTM A 8 MIL-S-87D MIL-S-87D AISI MIL-S-87D MIL-S-87D ASTM A 8 MIL-S-87D AISI A-B7 Steel ASTM A -B7 A-B7 Steel ASTM A -B7 A-H Steel A-H Steel. Glyd-Ring Filled PTFE. Glyd-Ring Filled PTFE. Glyd-Ring Filled PTFE > >> Recommended spare parts. Provided as "complete bypass assembly". Application Dependent For other body materials available, contact HBE with your service conditions. ASTM A -H ASTM A -H 8 8 7. HPM lb.- lb. 7.. HPM lb.- lb. Bypass Detail Pos. 7 Description Bypass Bushing Control Head Lever Pivot Pin Crank Arm Control Brushing Flow Straightener Guide Pin Stud Hex Nut > >> Recommended spare parts. Material Specification ASTM A8 ASTM A8 ASTM A8 AISI ASTM A8 ASTM A8 MIL-S-87D AISI A-B7 Steel ASTM A--B7 A-H Steel Provided as "complete bypass assembly". Application Dependent ASTM A--H LPM lb.- lb. Bypass Detail

Dimensions, Weights and Flow Ratings L H S Size alve V w Main Flo ax. M w Flo Bypass Max. Bypass Cv Max. eight W s Dimension ain M s ypas B I NS A M P G M h M P G M h. bs L. Kg L (in) L (mm) H (in) H (mm) S (in) S (mm) -/..... 7 7 7 7 7-7/8 / / -/ -/ -/ -/ -/ - -/ 7 -/8 7-/ 7-/ 7-7/8 8-7/.7.7.7.7. 7 8 8 -/ -/ -/ -/8 -/ -/ -/ -/ -/8 -/8-7/ 7-/ 7-/8 8 -/ 8 -/ -/ 7.8.8... 8 8 88-7/ -/8 -/8 -/ -/ 8 -/ -/ -/ -/ -/ -7/8 7-/ 8-/ -/ -/ 7 -/.... 8 8 8 7 8 8 -/ -/ -/ -/8 7-/ 8 8 -/ -/ -/ -7/8 -/ 7-/ 8-/ -7/ -/ -/ 7 7.. 8... 78 77 77 8 -/ -/ -/ 7-/ -/ -/ -/8 -/8 -/ 7-/ 8-/ -7/ -/ -/ 8 -/.7.7.. 8 8 8 87 -/ -/ -/ -/ -/ -/ -7/8-7/8 7-/ -/ 7 7 8 -/ -7/ -/ -/ -7/ 8 77 7 7 8 8 8-7/8 -/8 -/8 -/ 7-/ 8 8 7 -/ 7-/ 7-/ 7-7/8 -/ -/ -/8 -/ -/ -/ 8 8 7 77 7 77 8 78 -/8 -/ -/ -/ -7/ 7 8 7-7/8 8-7/ 8-7/ 8-7/8 -/8 -/ -/ -/ 8-/ 8 7 7 8 8 7 8 88 8 7 8 8 8 8-/ -/ -/ -/ 8-/8 7 77 8 8 7-7/ -/ -/8 -/8 7 7 -/ -/ -/ -/ -7/ 8 8 8 77 87 8 8 7 778-7/ -/ -/8 -/8 -/ 8 -/ -/ -/ -/ 8-7/8 -/ -/ -/ 7-/ 7 on based are low ratings F. of gravity specific with F water rating. " than higher flows with applications and data valve lb. HBE for Contact imensions D ±. BWE and Flanged for same the are Dimensions /8".

Start Up Internals One of the most common means of valve damage is start up debris. Regardless of how clean the system is, weld pearls, wear ring particles and other items seem to end up inside control valve internals and damage seating surfaces enough to cause premature leakage. Take the risk out of start up operations by using start up bypass internals. These factory installed internals take the place of the standard operating internals and provide continuous flow during start up and flush out any debris. The internals are field adjustable if flow changes are required. After completion of start up the internals are easily removed and replaced with operating internals. Start Up Internal Detail Pump Run Out Protection Normally pump protection valves are limited to minimum flow protection; however, severe damage can occur to the pump and driver by exceeding the intended operating range of the pump. flow reaches the maximum desired flow rate. At full lift the orifice holes in the body insert and disc line up stopping additional flow. Damage due to excessive flow can be eliminated by designing a Maxi-Flow as an addition to the standard minimum flow valve. Excessive flow protection is achieved by installing an insert with a row of orifice holes into the main valve body. During normal main flow operation the fluid passes through the holes with a minimal pressure head loss. In addition a special disc is provided which has a sleeve around the diameter with a row of orifice holes. The disc is at full lift when the forward Maximum flow protection prevents exceeding the steam drum desired water level if the drum level control valve failed open in boiler feed service. For process fluids and sea water in which pipe corrosion is a concern the maximum flow protection provides run out protection if piping leaks occur from corrosion. Run Out Protection Detail 7

How to Order and Specify The centrifugal pump shall be protected by the HPM Model automatic recirculation valve which is completely selfcontained and fully automatic via flow activation. The valve protects the pump from reverse flow and prevents overheating during low process demands. Operation of the valve bypass will be modulating so the sum of the main and bypass flow will never be less than the minimum flow requirement of the pump. design will incorporate a radial split body spring assisted check valve disc and multi-stage vortex plug bypass assembly. Materials of construction will consist of a A- forged carbon steel body housing with stainless steel internals. If service conditions dictate other materials are available such as stainless steel, low temperature steel and other alloys. The valve will be designed to operate without flashing or cavitation occurring during bypass operation. Any necessary accessories such as orifices or anti-flash valves will be provided by HBE to prevent flashing or cavitation in the bypass piping. Required Application Data Main Flow Minimum Maximum Normal Minimum Pump Flow Pump Discharger Pressure @ Normal Flow Bypass flow Shut off Bypass Backpressure GPM (m/hr) GPM (m/hr) GPM (m/hr) GPM (m/hr) PSIG (kpa) PSIG (kpa) PSIG (kpa) PSIG (kpa) Temperature Normal F ( C) Maximum F ( C) Liquid * Specific Gravity * Vapor Pressure psia * Viscosity centipoise (* if other than water) Model Legend Model Designation LPM - Low pressure modulating automatic recirculating valve with forged body housing. and lb. ANSI Class. HPM - High pressure modulating automatic recirculating valve with forged body housing.,, and lb. ANSI Class. Size Code = " =." 8 = " = " = " HPM---XXXX = " = " = 8" = " 8 = " Quote/Order File Number Pressure Class Code = = = = = = The example translated is an HPM model, - lb. flanged valve with an HBE file locator number. A written description of the material of construction and end connections follows this model number. 8 ENGINEERINGInc. Portage Avenue, Three Rivers, MI USA Phone: -7- Fax: -78-7