Technical Information SUNNY BOY / SUNNY TRIPOWER Temperature Derating

Similar documents
Technical Information Temperature Derating for Sunny Boy and Sunny Tripower

Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

Technical Information PV Inverters

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

500 / 630 / 720 / 760 / 800 / 850 / 900

Sunny Tripower CORE1.

Figure 1b: Daily Production Profile Non Power Limiting Day

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

Technical Information Average Efficiency of the SMA Flexible Storage System

Transportation and Installation Requirements SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/ 760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK

Why array oversizing makes financial sense

Design of Off-Grid Systems with Sunny Island 4.4M / 6.0H / 8.0H Devices

Technical Data. Windy Boy 6000US. Windy Boy 5000US. Windy Boy 7000US

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

Planning Guidelines SMA SMART HOME

Rooftop Solar PV System Designers and Installers. Training Curriculum. APEC Secretariat

Solar Inverters. No. 6, R. A. De Mel Mawatha, Colombo

WINDY BOY. Grid Connection of Small Wind Turbine Systems

Photovoltaics. MPI Hybrid Series

OVERSIZING WHITEPAPER

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

# 1, Bowes Place, Phillip, ACT 2606, Australia. Phone:

Operating Manual SUNNY TRIPOWER 15000TL / 20000TL / 25000TL

Operating Manual SUNNY BOY 3600 / 5000 SMART ENERGY BATTERY PACK SMART ENERGY

USER MANUAL MODEL: 3SPC3.3/106-D72/1100

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

High Frequency SineWave Guardian TM

ACE Variable Frequency Drive System

SMA Export Control Solution

Multi-Function Interface MULTI-FUNCTION RELAY

SolarMax MT series The all-rounder for trade and industry

SMA FLEXIBLE STORAGE SYSTEM

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Solutions for Profitable PV Power Plants

PV inverter SUNNY MINI CENTRAL 7000HV

Technical information SUNNY BOY SMART ENERGY / SUNNY BOY STORAGE / SUNNY ISLAND

Duo Battery Charge Controller

Increased requirements on external DC-breakers for transformerless PV inverters in Australia

SolarMax P series The power package for residential solar plants

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110,

Power Optimization and Monitoring in Photovoltaic Systems. Perry Tsao, Ph.D. January 20, 2010

Total number of PV modules: 42 Energy usability factor: 99.9 % Number of PV inverters: 1

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Wind Power Inverter WINDY BOY 5000A/6000A

Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

SMA INTEGRATED STORAGE SYSTEM

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

The Traveler Series: Adventurer

Dr. Bernd Engel. Frank Greizer Joachim Laschinski Dr. Mike Meinhardt Dr. Matthias Victor. 20 th European PV Conference Barcelona 2005

Planning Guidelines SMA SMART HOME The System Solution for Greater Independence

250kW Solar PV System Poultry Shed Solution - Gatton

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Good Enough Never Is. Plug Fan SERIES 12

ABB central inverters PVS to 2000 kva

Ningbo Star Solar Co.,Ltd Tel:(86) Fax:(86)

Planning Guidelines SMA SMART HOME The System Solution for more Independence

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Solar Powered System - 2

Solar Photovoltaic (PV) Design Considerations & Issues. By Paul M. Williams, President & CEO

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Hilton Hunkin Senior Application Engineer SMA Solar Technology South Africa

The Traveler Series TM : Adventurer

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

General Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09

Solar Power Owner s Manual

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

ABB central inverters PVS to 1000 kw

STONESTAR AUSTRALIA PTY LTD

Pika Energy Island Made in America

Yield Reduction Due to Shading:

INDUSTRIAL THERMAL MANAGEMENT. Filter fans FL-Series

Advanced Active And Reactive Power Control For Mini Grids

ABB central inverters PVS to 1000 kw

3.1 General Information

Lecture- 9: Load Equalization and Two Mark Questions. Load Equalization

Renewable Energy Catalogue

Assembly instructions

PV Inverter SUNNY BOY 3300/3800

New Central Grid-tied PV Inverters. 500kW/1MW 3-level T-type modular inverters 1MW/2MW PV power containers

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Yield Reduction Due to Shading:

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

HOW TO USE H5000B TO RUN 5KW OF ENPHASE M250 OFF-GRID

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

ABB central inverters PVS to 2091 kva

A low voltage advantage that eclipses the rest

AeroVironment Universal Solar Pump Controllers

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

SUNNY BOY 2000HF / 2500HF / 3000HF

Photovoltaic Solar Plan Review

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Transcription:

Technical Information SUNNY BOY / SUNNY TRIPOWER Temperature Derating ENGLISH Temp-Derating-TI-en-14 Version 1.4

1 Introduction SMA Solar Technology AG 1 Introduction Temperature derating occurs when the inverter reduces its power in order to protect components from overheating. This document explains how inverter temperature is controlled, what causes temperature derating and what can be done to prevent it. 2 What is Temperature Derating? Derating is the controlled reduction of the inverter power. In normal operation, inverters operate at their maximum power point. At this operating point, the ratio between PV voltage and PV current results in the maximum power. The maximum power point changes constantly depending on solar irradiation levels and PV module temperature. Temperature derating prevents the sensitive semiconductors in the inverter from overheating. Once the permissible temperature on the monitored components is reached, the inverter shifts its operating point to a reduced power level. The power is reduced in steps. In extreme cases, the inverter will shut down completely. As soon as the temperature of the sensitive components falls below a critical value again, the inverter returns to the optimum operating point. Stanardized output power 1.0 0.8 0.6 0.4 0.2 0 10 20 30 40 50 60 Ambient temperature [ C] Figure 1: Example of a power curve with temperature derating Temperature derating occurs for various reasons, including the following: The inverter cannot dissipate heat due to unfavorable installation conditions. The inverter is operated in direct sunlight or at high ambient temperatures that prevent adequate heat dissipation. The PV array and inverter are mismatched (power of the PV array compared to the power of the inverter). If the installation site of the inverter is at an unfavorable altitude (e.g. altitudes in the range of the maximum operating altitude or above Mean Sea Level, see Section "Technical Data" in the inverter operating manual). As a result, temperature derating is more likely to occur since the air is less dense at high altitudes and thus less able to cool the components. A constantly high DC voltage (V_MPP) is present at the inverter. 2 Temp-Derating-TI-en-14 Technical Information

SMA Solar Technology AG 2 What is Temperature Derating? Since each DC operating voltage has a considerable influence on the derating behavior of the inverter, it is useful to represent different DC operating voltages in a temperature curve for clarification (see figure 2). Derating as a function of the DC operating voltage of an SMA inverter is shown based on the current requirements specified in the relevant standards (e.g. DIN EN 50524): minimum DC voltage (V_MPP_Min), nominal DC voltage (V_nom) and maximum DC voltage (V_MPP_Max). 1.0 Output power / Rated power 0.8 0.6 0.4 0.2 V PV = 390 V DC V PV = 600 V DC V PV = 800 V DC 20 30 40 50 60 70 Ambient temperature [ C] Figure 2: Example for derating behavior of an SMA inverter at various operating voltages The following figure (figure 3) shows different operating points of a PV system as an example (Australia, Alice Springs; 140% oversizing) depending on the respective ambient temperature and the DC operating voltage that arise in the PV array. The inverter can continuously operate at maximum power as long as it remains in the area on the left of the characteristic curve. The figure shows that the influence of high DC voltages on the temperature behavior may not be overrated. For instance, the DC operating voltage decreases when the temperature increases: from 800 VDC at 15 C to 720 VDC at 40 C. In this case, the maximum DC voltage of the inverter acts more as a technical boundary than a normal operating curve. There is no PV array operating point that requires the inverter to feed in at full power at temperatures above 31 C (at 800 V). 800 Vmpp in V DC operating voltage [V] 700 600 500 400 300 Ambient temperature [ C] 400 V at 38 C 580 V at 51 C 800 V at 31 C 10.0 20.0 30.0 40.0 50.0 Figure 3: Operating points of a PV system and characteristic curve of the operating range within which the inverter can feed maximum power into the grid (location of the PV system: Australia, Alice Springs; 140% oversizing) On principle, temperature derating has no negative effects on the inverter. A glowing LED and a warning on the inverter display indicate when the inverter is in the operating state "Derating". The inverter continues to display this warning until shutting down at sunset. Technical Information Temp-Derating-TI-en-14 3

3 System Design and Temperature Derating SMA Solar Technology AG 3 System Design and Temperature Derating Correct PV system design must not necessarily entirely exclude derating. PV systems are optimized in terms of total energy yield. The output power of the inverter is calculated from the PV array power and the inverter efficiency. Therefore it is crucial that the product of these two factors is as large as possible. Figure 4 shows how much energy is produced in one year by a PV array located in Freiburg im Breisgau, Germany, and how the power output is distributed within the power range of the PV array. The diagram also shows the frequency with which the PV array produces a particular power output. The low power outputs in the lower partial load regions occur very frequently and so account for a significant proportion of total power. 6 5 P AC Frequency Energy distribution [%] 4 3 2 1 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Power of PV generator [kw/kwp] Figure 4: Energy supply relative to the power range of the PV array (example: Freiburg im Breisgau, Germany) The inverter efficiency curve states how efficiently it can convert the power provided by the PV array. In order to avoid derating at peak PV array outputs, an inverter with a nominal power of more than 100% of the PV array power could be selected. However, this would shift a larger proportion of partial load yields to a range within which the inverter is relatively inefficient. The losses experienced within this partial load range would exceed the gains obtained by avoiding derating at peak outputs (see figure 6). 6 Energy distribution [%] 5 4 3 2 1 P DC P AC Difference P DC - P AC 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Power of PV generator [kw/kwp] Figure 5: Efficiency, input power and output power of the inverter when the nominal power of the inverter is 90% to 100% of the PV array power. 4 Temp-Derating-TI-en-14 Technical Information

SMA Solar Technology AG 4 Heat dissipation of the inverters Energy distribution [%] 6 5 4 3 2 1 P DC P AC Difference P DC - P AC 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Power of PV generator [kw/kwp] Figure 6: Efficiency, input power and output power of the inverter when the nominal power of the inverter is more than 100% of the PV array power Derating rarely occurs when the PV system is well matched. Derating is more common when the inverter is undersized relative to the PV array (see Section 2, page 2 for the causes of frequent temperature derating). You can determine the ideal design for your PV system with the "Sunny Design" software. This design software is available free of charge at www.sma-solar.com. 4 Heat dissipation of the inverters SMA inverters have cooling systems tailored to their power and design. Passively cooled inverters dissipate heat to the atmosphere through heat sinks. Actively cooled devices with OptiCool systems have supplementary ventilation. As soon as the device generates more heat than its enclosure can dissipate, an internal fan switches on and draws in air through the cooling ducts of the enclosure. The fan is speed-controlled: it turns faster as the temperature rises. The advantage of active cooling is that the inverter can continue to feed in its maximum power as the temperature rises. The inverter is not derated until the cooling system reaches the limits of its capacity. Actively cooled inverters thus have extra power reserves compared to passively cooled devices. You can avoid temperature derating by installing inverters in such a way that the heat is adequately dissipated: Install inverters in cool locations, e.g. basements instead of attics. Choose locations with sufficient air circulation. Install additional ventilation if needed. Do not expose the inverter to direct solar irradiation. If you install an inverter outdoors, position it in the shade or install a roof overhead. Maintain the minimum clearances from adjacent inverters or other objects, as specified in the installation manual. Increase the clearances if high temperatures are likely to occur at the installation site. When installing several inverters, arrange them so that they do not draw in the warm exhaust air emitted by other inverters. Passively cooled inverters are offset so the heat from the heat sinks can escape upwards. Technical Information Temp-Derating-TI-en-14 5

4 Heat dissipation of the inverters SMA Solar Technology AG Figure 7: Arrangement of passively cooled inverters to optimize heat dissipation: SB XX-1AV-40 The optimum arrangement for actively cooled inverters depends on the position of the air intake and exhaust openings. Several examples are shown below. Figure 8: Arrangement of actively cooled inverters to optimize heat dissipation: STP XXXXXTL-30 Figure 9: Arrangement of actively cooled inverters to optimize heat dissipation: STP50-40 6 Temp-Derating-TI-en-14 Technical Information

SMA Solar Technology AG 5 Managing Temperature Derating 5 Managing Temperature Derating SMA inverters are designed to stay below the permissible operating temperature as long as the PV system is properly designed and operated in suitable ambient conditions. However, temperature derating may still occur for the following reasons: The inverter cannot dissipate enough heat to the atmosphere because the heat sinks or fan guards are clogged or the fans have failed. Clean the affected parts as described in the inverter installation manual. The selected inverter power is too low compared to the PV array power. This configuration may make financial sense and is being adopted more and more in the field. Even if the PV system is properly designed, the power of the PV array may still exceed the nominal power of the inverter in extreme climatic conditions, such as high solar irradiation combined with low PV module temperatures. The inverter installation site does not have the necessary climatic conditions (see Section "Technical Data" in the inverter manual). In this case, the inverter should be relocated to a more suitable site by a qualified person. Make sure to maintain the recommended clearances between multiple devices. Increase the clearances even more in warm installation environments. Install the devices away from the hot exhaust air streams of other inverters (see Section 4, page 5). Provide additional cooling for the inverter, if necessary. Ventilate multiple inverters in such a way that the airflow cools all devices equally. Technical Information Temp-Derating-TI-en-14 7

www.sma-solar.com