Illusion Split System

Similar documents
New Stylus. Product Catalog. Split System, 1-5 Tons Convertible Type MCX Series 60 Hz MS-PRC015-EN. May 2009

Split System Cooling Product & Performance Data

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz

Concealed Ducted Split Series R22

Modular Variable Speed Air Handlers

SPLIT SYSTEM COOLING 2½, 3, 4 & 5 TON ALLEGIANCE 18 MODELS 2A7A8030, 036, 048 & 060B American Standard Inc. All Rights Reserved

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON ALLEGIANCE 16 MODELS 4A7A6024,036,048 & 060B American Standard Inc. All Rights Reserved

From Dwg. 21D Rev. 10. A-weighted Sound Power Level [db(a)]

Product Data /4YCC3018A through 2/4YCC3060A Single Package Convertible Gas/Electric 13 SEER 1½ - 5 Ton, MBTU R-22/R-410A

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

Product Data. Convertible Air Handlers 1 1/2 5 Ton B-EN. August 2015

Package Air Conditioners

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Product Data. Convertible Air Handlers 1 1/2 5 Ton D-EN. September 2016

Commercial Blower Coil Air Handlers

DP15CH. Packaged Air Conditioner UP TO 15 SEER 2 to 5 Tons. Cooling Capacity: 23,600-57,500 BTU/h

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

GPH13H PRODUCT SPECIFICATIONS 13 SEER PACKAGED HEAT PUMP 2 TO 5 TONS COOLING CAPACITY: 25,000-57,000 BTU/H HEATING CAPACITY: 24,000-54,400 BTU/H

10AC DIPLOMAT SERIES RFC SYSTEMS

DESCRIPTION FEATURES

CHP

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

HEAT PUMPS UPKB- SERIES. Seven Models

Product Data PH3Z 13 SEER SINGLE -PACKAGED HEAT PUMP SYSTEM WITH R -22 REFRIGERANT SINGLE AND THREE PHASE 2-5 NOMINAL TONS ( )

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

SSX14 PRODUCT SPECIFICATIONS 14 SEER / R-410A HIGH-EFFICIENCY SPLIT SYSTEM AIR CONDITIONER 1½- TO 5-TON COOLING CAPACITY 18,000 TO 56,800 BTU/H

2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil

N4A6. Product Specifications

TECHNICAL GUIDE R-410A, 13 SEER LATITUDE SERIES 60 Hertz

CAS. Product Specifications

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

R-22, 13 SEER 60 Hertz

3 1/2 Ton Convertible Air Handler TAM7A0C42H31SD Standard Coil TAM7A0C42H31EA Black Epoxy Coil

HEAT PUMPS CLASSIC X HEAT PUMPS RPKA- SERIES. Nominal Sizes 1 1 /2 to 5 Tons [5.28 to kw]

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

Product Data. Convertible Air Handlers 1 1/2 5Ton

PACKAGE AIR CONDITIONERS

Product Catalogue. Large Commercial Split System. Split System Tons RAUP/TTV Models 50 Hz. August 2005 SSA5-PRC003-EN

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 13 MODELS 2A7A A American Standard Heating & Air Conditioning

Product Data. Convertible Air Handlers 1 1/2 5Ton

48CWA2-00 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 48,000 BTUH

HCH6. Product Specifications

DZ13SA. Split-System heat pump. Cooling Capacity: 17,400-55,000 BTU/h Heating Capacity: 15,200-59,000 BTU/h

CONDENSING UNITS CLASSIC X CONDENSING UNITS RAKA- SERIES. Seven Models. Cooling Capacities 17,000 to 56,500 BTU/HR [4.98 kw] to [16.

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Specification. 3 Ton Convertible Air Handler TAM7A0C36H31SC TAM7A0C36 SPEC-1D

PAB SERIES 3thru6-1/3Ton. Belt Drive 10 SEER CONVERTIBLE SINGLE PACKAGE AIR CONDITIONING UNIT /01

Q7RE Series Single Packaged Heat Pump, Single Phase

GPC14M. Packaged Air Conditioner 2 through 5 Tons / 14 SEER. Cooling Capacity: 23,000-56,000 BTU/h

ZHA/ZHB SERIES WARNING

LISTED TECHNICAL GUIDE STEALTH SPLIT-SYSTEM HEAT PUMP 15 SEER MODELS: E4TS030 THRU 060 (2.5 THRU 5 NOMINAL TONS) DESCRIPTION FEATURES

DZ14S Commercial 3-5 TON, THREE-PHASE SPLIT SYSTEM HEAT PUMP 14 SEER / R-410A

Modular Variable Speed Air Handlers

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

SSZ14. High-Efficiency. Split System Heat Pump. Cooling Capacity: 18,000 to 57,600 BTU/h. Up to 15 SEER & 8.5 HSPF

CONDENSING UNITS RAKB- SERIES. Seven Models

CAC SERIES 12-1/2 Thru 20 Ton

TECHNICAL GUIDE MODELS: RAC13J18 THRU 60 RAC SERIES SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 1 PHASE 1.5 THRU 5 NOMINAL TONS

DX11S Commercial & 10-Ton, Three-Phase. Cooling Capacity: 88, ,000 BTU/h

NXA6. Product Specifications HIGH EFFICIENCY 16 SEER AIR CONDITIONER

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

36CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V) 4-Pipe Heat & Cool Fan Coil 36,000 BTUH

SSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTZ0036B-SF-1B. ComfortLink II System Cooling 4TTZ0036B1000A CAUTION

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

13 SEER HEAT PUMPS Features Coils constructed with copper tubing and enhanced aluminum

24CWA4-HW 4-Pipe Chilled & Hot Water Air Handler (120V)

PCB COMMERCIAL SERIES

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

LISTED TECHNICAL GUIDE HORIZONTAL DISCHARGE AIR CONDITIONERS 13 SEER R-410A MODELS: YCHD18 THRU 60 (1.5 THRU 5 NOMINAL TONS, 1 PHASE)

PHB SERIES 7-1/2 and 10 TON

VHIA High-Static Ducted Indoor Units - 60HZ

HEAT PUMPS UPLB- SERIES. Seven Models

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

GPH13H. Packaged Heat Pump. 13 SEER / R-410A 2 to 5 Tons. Cooling Capacity: 24,000-57,500 BTU/h Heating Capacity: 22,000-54,500 BTU/h

ASZ13 13 SEER / R-410A. Heating Capacity: 18,000-59,000 BTU/h

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

D M S 760 C01 A A 1 1

DSZC16. Split System Heat Pump Up to 16 SEER & 9.5 HSPF. Cooling Capacity: 24,000-60,000 BTU/h Heating Capacity: 24,000-60,000 BTU/h

CONDENSING UNITS ACHIEVER 12 SUPER HIGH EFFICIENCY CONDENSING UNITS UAMA- SERIES. Seven Models

WE MAKE INDOOR AIR BETTER

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

38P 60Hz Nominal Cooling Capacity Tons HFC R -410A Refrigerant

Q7RE Series Single Packaged Heat Pump, Single Phase

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Transcription:

Illusion Split System Split System Air Conditioning (Concealed Type) -5 Ton - 50 Hz - R 22 Indoor Units MCD52DB MCD58DB MCD524DB MCD530DB MCD536DB MCD048DB MCD060DB Outdoor Units 2TTB052AA000D 2TTB058AA000D 2TTB0524AA000C 2TTB0530AA000C 2TTB0536AA000C 2TTA0040AD000B 2TTA0050AD000B 2TTA0060AD000B SS-PRC039-EN

Table of Contents Features and Benefits... 3-5 System Performance... 6 Selection Procedures... 7-9 General Data.. MCD... 0-2TTB...2-3 2TTA... 3 Performance Data.. MCD Fan Performance... 4-9 Cooling Performance... 20-27 2TTB/MCD... 20-24 2TTA/MCD... 25-27 Typical Wiring Diagrams... 28-35 Dimensional Data... 37-40 2

General Features and Benefits 2TTB0 Split System Features (Outdoor units) 2TTB0 split systems represent a product that is not only an engineer s dream but also a customer's dream. The design team s mission and accomplishment is enhanced performance and efficiency, improved reliability and durability, and improved installability and serviceability. Trane s experienced design team applied Six Sigma Principles, the latest computer technology and customer research to develop the next generation of leadership products. Combine the Trane reputation for reliability and durability with the above mentioned mission and accomplishment and you will continue to have systems that prove It s Hard to Stop a Trane. Benefits Climatuff compressor All aluminum Spine Fin coil DuraTuff base, fast complete drain, weather proof New cabinet with anthracite base and polystate gray cabinet Quick-Sess cabinet, service access and refrigerant connections with full coil protection Corrosion resistant finish and fasteners High/low pressure and temperature protection Liquid line filter-drier Easy single side service Multi-use liquid and suction line service valves Easy top and fan removal Full length control cover Sure Fast seams louver panel removal HCFC-22 refrigerant Extended warranties available S.E.E.T. design testing 00% line run test 2TTA0 Split System Features (Outdoor units) 2TTA0 split systems represent a product that is not only an engineer s dream but also a customer s dream. The design team s mission and accomplishment is enhanced performance and efficiency, improved reliability and durability, and improved installability and serviceability. Trane s experienced design team applied Six Sigma Principles, the latest computer technology and customer research to develop the next generation of leadership products. Couple the Trane reputation for reliability and durability with the above mentioned mission and accomplishments and you will continue to have systems that prove It s Hard to Stop a Trane. Benefits Climatuff compressor All aluminum Spine Fin coil DuraTuff base, fast complete drain, weather proof WeatherGuard fasteners Quick-Sess cabinet, service access and refrigerant connections with full coil protection Corrosion resistant finish and fasteners High/low pressure & temperature protection Liquid line filter-drier Easy single side service Multi-use liquid and suction line service valves Compressor sump heat Easy top & fan removal HCFC-22 refrigerant S.E.E.T. design testing 00% line run test 3

Features and Benefits MCD Concealed Unit Features: Compact Design Triple Layer Drain Pan* 4 Speed Fan Motor Optional Electric Heater Benefits: Flexibility in installation locations. Protect against condensate leaks. Flexibility in airflow. Whisper quiet operation. Ease of installation MCD Air Handler unit Complete family of concealed models- available in capacities ranging from 2,000 to 60,000 Btu/h. Compact height- only 258 mm. for 2,000 to 36,000 Btu/h models- the MCD Series is very compact for easy installation into tight ceiling locations. Triple protection drain pan of three layers provide maximum insulation and water integrity. First, a single piece of galvanized steel; next, a single piece of polystyrene; and finally, a vacuum formed plastic liner. Full capacity- the MCD Series has been tested and proved to provide full capacity and energy savings. A B C Plastic Polystyrene foam Galvanized sheet Triple protection drain pan Effectively prevents ceiling damage from drain pan leaks Decreases chance of mold Enhances indoor air quality 4 A B C Illusion drain pans consist of three layers: a single piece of galvanized sheet, a single piece of polystyrene foam, and a vacuum formed plastic liner. It also features a high-quality, flexible drain hose which is suitable for PVC size.

Feature and Benefits / Optional Fan speed: Four fan levels provide continuous, cool airflow Temperature setting: Set temperature range is from 5 to 30. Touch wired control (ACYSTAT60AA cooling only) (ACYSTAT260AA cool and heat) Powercool (turbo) mode: Cool off quicker (Turbo mode for LCD wired control) Sleep mode: Stay comfortable with automatic room temperature adjustment during the night Econo mode: Save energy while keeping cool Dry mode: provides effective humidity reduction with high efficient cooling capacity. 24 hours programmable timer: Select on/off times to schedule even more energy and cost savings LCD wired control (ACYSTAT0AA cooling only) (ACYSTAT20AA cool and heat) Receiver LCD wireless remote control (ACYSTAT20AA cooling only) (ACYSTAT220AA cool and heat) LCD wireless remote control Receiver (ACYSTAT70AA Cooling Only) (ACYSTAT270AA Cool & Heat) Digital touch-control series Choose from wired or wireless control Touch-control switch Intelligent features add more convenience 5

System Performance Nominal Rating Outdoor Unit Indoor Unit MBH CFM 2TTB052AA MCD52DBP 3.2 300 2TTB052AA MCD58DBP 5.3 450 2TTB058AA MCD58DBP 8.2 450 2TTB058AA MCD524DBP 9.0 600 2TTB0524AA MCD524DBP 24.0 600 2TTB0524AA MCD530DBP 24.8 750 2TTB0530AA MCD524DBP 26.6 600 2TTB0530AA MCD530DBP 27.9 750 2TTB0536AA MCD530DBP 32.8 750 2TTB0536AA MCD536DBP 34.0 900 2TTA0040AD MCD536DBP 36.6 900 2TTA0040AD MCD048DBP 39.2 600 2TTA0050AD MCD048DBP 49. 600 2TTA0050AD MCD060DBP 53.0 2000 2TTA0060AD MCD060DBP 60.9 2000 6

Model Nomenclature M C D 5 2 D B 0 0 B A 2 3 4 5 6 7 8 9 0 2 Digit No. - Product Type M = MiniSplit Digit No. 2 C = Cooling Only W = Heat Pump Digit No. 3 - Configuration D = Concealed Digit No. 4 - Refrigerant Connection 5 = Flare 0 = Sweat (Brazed) Digit No. 5 and No. 6 - Nominal Capacity Btu/h x 000 (Note: Exact system capacities/ performance when matched with selected indoor unit are specified in Product Catalogs.) Digit No. 7 - Major Development Sequence Digit No. 8 - Electric Power Supply Characteristics B = 240V/ph/50Hz or 220-240V/ph/50Hz D = 380-45V/3ph/50Hz Digit No. 9 - Electric Heat / Plenum 0 = no electric heater / no plenum 5 = High efficiency models C =.0 kw / no plenum D =.5 kw / no plenum E = 2.0 kw / no plenum F = 2.5 kw / no plenum G = 3.0 kw / no plenum H = 4.0 kw / no plenum I = 4.5 kw / no plenum P = no electric heater/with return plenum Q =.0 kw / with return plenum R =.5 kw / with return plenum S = 2.0 kw / with return plenum T = 2.5 kw / with return plenum U = 3.0 kw / with return plenum V = 4.0 kw / with return plenum W = 4.5 kw / with return plenum X = 5.0 kw / with return plenum Y = 6.0 kw / with return plenum Z = 7.0 kw / with return plenum Digit No. 0 - Thermostat Option 0 = None Digit No. - Minor Design Sequence/Series - Design Change Alphabetic Letter, A through Z Digit No. 2 - Service Digit 7

Model Nomenclature Outdoor Units (2TTB0) 2 3 4 5 6 7 8 9 0 2 3 4 5 2 T T B 0 5 3 6 A A 0 0 0 A A Refrigerant Type 2 = R-22 4 = R-40A TRANE Product Type W= Split Heat Pump T= Split Cooling Product Family Z = LEADERSHIP - 2 STAGE X = LEADERSHIP R = REPLACEMENT / RETAIL B = BASIC A = LIGHT COMMERCIAL Secondary Function Power Supply A = 220 / / 50 D = 380-45 / 3 / 50 Unit Parts Identifier Minor Design Modifications Family SEER 0 = 0 2 = 2 4 = 4 = 3 = 3 6 = 6 8 = 8 Major Design Modifications Nominal Capacity in 000s of BTUs Split System Connections - 6 Tons 0 = Brazed 5 = Flare 8

Model Nomenclature Outdoor Units (2TTA0) 2 3 4 5 6 7 8 9 0 2 3 4 5 2 T T A 0 5 3 6 A A 0 0 0 A A Refrigerant Type 2 = R-22 4 = R-40A TRANE Product Type W= Split Heat Pump T= Split Cooling Product Family Z = LEADERSHIP - 2 STAGE X = LEADERSHIP R = REPLACEMENT / RETAIL B = BASIC A = LIGHT COMMERCIAL Secondary Function Power Supply A = 220 / / 50 D = 380-45 / 3 / 50 Unit Parts Identifier Minor Design Modifications Family SEER 0 = 0 2 = 2 4 = 4 = 3 = 3 6 = 6 8 = 8 Major Design Modifications Nominal Capacity in 000s of BTUs Split System Connections - 6 Tons 0 = Brazed 5 = Flare 9

General Data General Data MCD 50Hz UNIT MODELS MCD52DBP MCD58DBP MCD524DBP MCD530DBP MCD536DBP MCD52DBS 2 MCD58DBT 2 MCD524DBU 2 MCD530DBV 2 MCD536DBW 2 POWER CONNECTION V/ph/Hz 220-240//50 220-240//50 220-240//50 220-240//50 220-240//50 MCA 3 A 2.0 5.3 8.8 25.2 28.3 SYSTEM DATA Refrigerant Type R-22 R-22 R-22 R-22 R-22 Refrigerant Connection Type Flare Flare Flare Flare Flare Suction Line OD in (mm) /2 (2.70) /2 (2.70) 5/8 (5.88) 5/8 (5.88) 3/4 (9.05) Liquid line OD in (mm) /4 (6.35) /4 (6.35) 3/8 (9.53) 3/8 (9.53) 3/8 (9.53) CASING Material / Color Galvanized Steel/Unpainted Type of Insulation / Thickness in (mm) Fiberglass ( 2.70 ) Insulation Density Kg./m 3 40 40 40 40 40 COIL Face Area sq ft (m 2 ).67 (0.6).67 (0.6).67 (0.6) 2.00 (0.9) 2.33 (0.22) Tube Size OD in (mm) 3/8 (9.53) 3/8 (9.53) 3/8 (9.53) 3/8 (9.53) 3/8 (9.53) Tube Type Plain Inn. Grv. Inn. Grv. Inn. Grv. Inn. Grv. Rows 2 2 3 3 3 Fin Type Precoated Slit Precoated Slit Precoated Slit Precoated Slit Precoated Slit Fins per inch 9 20 5 5 4 Refrigerant Flow Control Capillary Tube Capillary Tube Capillary Tube Capillary Tube Capillary Tube Drain Connection Size in (mm) /2 (2.70) /2 (2.70) /2 (2.70) /2 (2.70) /2 (2.70) ELECTRIC HEATER DATA 2 Heater Rating kw 2 2.5 3 4 (2 elements) 4.5 (2 elements) Heater RLA FAN 9..4 3.6 8.2 20.5 Fan Type Centrifugal/GI Centrifugal/GI Centrifugal/GI Centrifugal/GI Centrifugal/GI No. used 2 2 2 2 2 Diameter in (mm) 6 (44.0) 6 (44.0) 7 (64.0) 7 (64.0) 7 (64.0) Width in (mm) 7 (88.0) 7 (88.0) 8 (20.0) 8 (20.0) 8 (20.0) Drive Type MOTOR Motor Type Direct Direct Direct Permanent Split Capacitor Direct Direct No. of Motor Motor Power hp (kw) /20 (0.04) /8 (0.087) /4 (0.93) /3 (0.278) /2 (0.26) No. of Speed 4 4 4 4 4 Motor Speed rpm 200 / 00 / 000 / 900 400 / 300 / 200 / 00 400 / 200 / 00 / 000 400 / 350 / 250 / 00 400 / 350 / 250 / 50 V/ph/Hz 220//50 220//50 220//50 220//50 220//50 RLA/LRA FILTER,2 Type 0.48 / 0.80 0.82 /.86.37 / 3.5 Aluminum Filter.98 / 5.28 2.20 / 5.77 No. used Size (WxLxD) in 3 0.6 x 30.3 x.0 0.6 x 30.3 x.0 0.6 x 30.3 x.0 0.6 x 36.3 x.0 0.6 x 42.4 x.0 (mm) 3 (270 x 770 x 25) (270 x 770 x 25) (270 x 770 x 25) (270 x 922 x 25) (270 x,077 x 25) Indoor Sound Data dba 4 48 46 53 55 DIMENSION (HxWxD) Crated (Shipping),2 in 3 2.2 x 37.4 x 25.2 2.2 x 37.4 x 25.2 2.2 x 37.4 x 25.2 2.2 x 43.7 x 25.2 2.2 x 49.8 x 25.2 (mm) 3 (3 x 949 x 64) (3 x 949 x 64) (3 x 949 x 64) (3 x, x 64) (3 x,264 x Uncrated (Net),2 in 3.8 x 37.2 x 24.6.8 x 37.2 x 24.6.8 x 37.2 x 24.6.8 x 43.2 x 24.6.8 x 49.3 x 24.6 (mm) 3 (300 x 946 x 625) (300 x 946 x 625) (300 x 946 x 625) (300 x,098 x 625) (300 x,25 x 625) WEIGHT Crated (Shipping) lb (kg) 68.7 (3.3) 72.7 (33.) 78.5 (35.0) 89.0 (39.8) 99.5 (44.4) Crated (Shipping) 2 lb (kg) 7.7 (32.6) 75.7 (34.5) 80.5 (36.0) 94.0 (42.) 04.5 (46.7) Uncrated (Net) lb (kg) 63.7 (29.0) 67.7 (30.8) 73.0 (32.5) 83.0 (37.0) 9.0 (40.8) Uncrated (Net) 2 lb (kg) 66.7 (30.4) 70.7 (32.2) 76.0 (34.0) 87.0 (39.0) 96.0 (43.0) Model with plenum has alphabetic letter P in the ninth digit 2 Model with electric heater and plenum has alphabetic letter S T U V or W in the ninth digit 3 MCA - Minimum Circuit Ampacity ; calculated as follow : 25% of motor R.L.Amps plus heater R.L.Amps. 3 Test at free blow (0.0 in.wg ESP) / Dry Coil / Using ARI Standard 270-84 as a reference for test set up. 0

General Data General Data MCD 50Hz UNIT MODELS MCD048DBP MCD060DBP MCD048DBY MCD060DBZ POWER CONNECTION V/ph/Hz 220-240//50 220-240//50 MCA 2 A 38.2 45. SYSTEM DATA Refrigerant Type R-22 R-22 Refrigerant Connection Type Brazed Brazed Suction Line OD in (mm) /8 (28.58) /8 (28.58) Liquid line OD in (mm) 3/8 (9.53) 3/8 (9.53) CASING Material / Color Galvanized Steel / Unpainted Type of Insulation / Thickness in (mm) Fiberglass (2.70) Insulation Density Kg./ in 2 40 COIL Face Area sq ft (m 2 ) 3.50 (0.33) 4.08 (0.38) Tube Size OD in (mm) 3/8 (9.53) 3/8 (9.53) Tube Type Plain Inn. Grv. Rows 3 3 Fin Type Precoated Slit Precoated Slit Fins per inch 4 5 Refrigerant Flow Control Capillary Tube Capillary Tube Drain Connection Size ELECTRIC HEATER DATA in (mm) /2 (2.70) /2 (2.70) Heater Rating kw 6 (2 elements) 7 (2 elements) Heater RLA 27.2 3. 8 FAN Fan Type Centrifugal Centrifugal No. used 2 2 Diameter in (mm) 8 (203.2) 8 (203.2) Width in (mm) 9 (228.6) 0(254.0) Drive Type Direct Direct MOTOR Motor Type Permanent split capacitor No. of Motor Motor Power hp (kw) /2 (0.394) 3/4 (0.453) No. of Speed 4 4 Motor Speed rpm 200 / 00 / 000 / 850 250 / 00 / 970 / 850 V/ph/Hz 220-240//50 220-240//50 RLA/LRA 3.33 / 5.08 4.30 / 6.98 FILTER Type Aluminum Filter No. used Size (WxLxD) in 3 3.7 x 35.4 x.0 3.7 x 4.5 x.0 3 (mm) (350 x 90 x 25) (350 x,054 x 25) DIMENSION (HxWxD) Crated (Shipping) in 3 9.3 x 46.0 x 30.8 9.3 x 5.9 x 30.8 (mm) 3 (490 x,68 x 782) (490 x,37 x 782) Uncrated (Net) in 3 6.0 x 43.2 x 29.8 6.0 x 49.2 x 29.8 (mm) 3 (408 x,098 x 759) (408 x,25 x 759) WEIGHT Crated (Shipping) lb (kg) 6.6 (53.0) 32.0 (60.0) Crated (Shipping) lb (kg) 25.4 (57.0) 43.0 (65.0) Uncrated (Net) lb (kg) 06.7 (48.5) 2.0 (55.0) Uncrated (Net) lb (kg) 5.5 (52.5) 32.0 (60.0) Model with electric heater has alphabetic letter Y or Z in the ninth digit. 2 MCA - Minimum Circuit Ampacity ; calculated as follow : 25 % of motor R.L.Amps plus heater R.L.Amps.

General Data Outdoor Units Model Power Conn. - Volts/Ph/Hz Fuse Size - max. amps Min. Brch. Cir. Ampacity Br. Cir. Max. (Amps) Prot. Rtg. } Min. (Amps) Compressor - Type No. Used - No. Speeds Volts/Ph/Hz 6 R.L. Amps - L.R. Amps Outdoor Fan - Type No. Used Diameter in. (mm) Type Drive - No. Speeds 3 CFM @ 0.0 in. w.g. 3 CMH @ 0.0 mm. w.g. No. Motors - HP Motor Speed (RPM) Volts/Ph/Hz F.L. Amps Outdoor Coil - Type No. Rows Fins/in. (mm) Face Area sq ft (sq m) Tube Size in. (mm) Refrigerant 4 R-22 (O.D. Unit) - lbs. (kg) Factory Supplied 5 Line Size - OD Gas in. (mm) 5 Line Size - OD Liq. in. (mm) FCCV Restrictor Orifice Size in.(mm) Dimensions (H x W x D) Crated - in. - (mm) Uncrated 2TTB052AA 200/230//50 0.2 5 3 CLIMATUFF - 200/230//50 9.8-60 PROPELLER 4 (356) DIRECT - 200 2040 - /6 650 200/230//50 0.9 SPINE FIN -24 24 (0.945) 7.27 (0.675) 3/8 (9.53) 3-LBS., 2-OZ. YES 5/8 (5.9) /4(6.35).045 30. x 9.7 x 2.4 (765 x 50x 544) 2TTB058AA 200/230//50 3 20 5 CLIMATUFF - 200/230//50 9.8-60 PROPELLER 4(356) DIRECT - 225 2080 - /8 075 200/230//50 0.9 SPINE FIN -24 24 (0.945) 7.27(0.675) 3/8 (9.53) 3-LBS., 4-OZ. (2.6) YES 3/4 (9.) 5/6(7.94).05 30. x 9.7 x 2.4 (765 x 50 x 544) 2TTB0524AA 200/230//50 6 25 20 CLIMATUFF - 200/230//50 2.2-74.8 PROPELLER 9 (483) DIRECT - 825 303 - /8 075 200/230//50 0.9 SPINE FIN 24 (0.945) 9.72 (0.90) 3/8 (9.53) 4-LBS., 0-OZ. (.82) YES 3/4 (9.) 5/6 (7.94).059 30. x 26.7 x 30.2 (765 x 678 x 767) 2TTB0530AA 200/230//50 7 25 20 CLIMATUFF - 200/230//50 2.9-77.9 PROPELLER 9 (483) DIRECT - 825 303 - /8 075 200/230//50 0.9 SPINE FIN 24 (0.945) 9.72 (0.90) 3/8 (9.53) 4-LBS., 2-OZ. (2.6) YES 7/8 (22.2) 3/8 (9.53).065 30. x 26.7 x 30.2 (765 x 678 x 767) Weight lbs. (kg) Shipping Net 33 (60.3) 20 (54.4) 4 (64) 28 (58.) 75 (79.5) 56 (70.9) 78 (80.9) 59 (72.3) NOTES:. RATING CONDITIONS (COOLING): 80F (27C) D.B. 67F (20C) W.B. ENTERING AIR TO INDOOR COILOF APPLICABLE TYPE. 95F (35C) D.B. ENTERING AIR TO OUTDOOR COIL. INDOOR COILAND UNITCONNECTED BY25 FT. (7.62 METERS) TUBING. 2. RATING CONDITIONS (HEATING): 70F (2C) D.B. ENTERING AIR TO INDOOR COIL; 47F (8C) D.B. 43F (6C) W.B. ENTERING AIR TO OUTDOOR COIL. NO SUPPLEMENTARY HEAT INCLUDED. 3. STANDARD AIR - DRY COIL- OUTDOOR 4. THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNITNAMEPLATE AND SERVICE INSTRUCTIONS. 5. MAX. OF 80 FT. (24.38 METERS) TOTALMEASURED LENGTH INCLUDING 60 FT. (8.29 METERS) MAX. LIFTBETWEEN O.D. AND I.D. SECTIONS. 6. THIS VALUE SHOWN FOR COMPRESSOR RLAON THE UNITNAMEPLATE AND ON THIS SPECIFICATION SHEETIS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITYAND MAX. FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUITSELECTION CURRENT. 2

General Data Model 2TTB0536AA 2TTA0040AD 2TTA0050AD 2TTA0060AD Power Conn. - Volts/Ph/Hz Fuse Size - max. amps Min. Brch. Cir. Ampacity Br. Cir. Max. (Amps) Prot. Rtg. } Min. (Amps) Compressor - Type No. Used - No. Speeds Volts/Ph/Hz 6 R.L. Amps - L.R. Amps 200/230//50 26 40 40 CLIMATUFF - 200/230//50 9.9-24 380/45/3/50 9 5 5 CLIMATUFF - 380/45/3/50 0-5 380/45/3/50 2 20 20 CLIMATUFF - 380/45/3/50 4-70 380/45/3/50 4 20 20 CLIMATUFF - 380/45/3/50 9-73 Outdoor Fan - Type No. Used Diameter in. (mm) Type Drive - No. Speeds 3 CFM @ 0.0 in. w.g. 3 CMH @ 0.0 mm. w.g. No. Motors - HP Motor Speed (RPM) Volts/Ph/Hz F.L. Amps PROPELLER 9 (483) DIRECT- 2075 3528 - /4 075 200/230//50.3 PROPELLER 9 (483) DIRECT - 2075 3528 - /4 075 380/45/3/50 0.7 PROPELLER 23 (584) DIRECT - 3075 5228 - /4 825 380/45/3/50.00 PROPELLER 27.6 (70) DIRECT - 3525 5993 - /6 825 380/45/3/50 0.7 Outdoor Coil - Type No. Rows Fins/in. (mm) Face Area sq ft (sq m) Tube Size in. (mm) SPINE FIN 24 (0.945).32 (.05) 3/8 (9.53) SPINE FIN 24 (0.945) 3.75 (.28) 3/8 (9.53) SPINE FIN 24 (0.945) 8.75 (.74) 3/8 (9.53) SPINE FIN 24 (0.945) 27.75 (2.59) 3/8 (9.53) Refrigerant 4 R-22 (O.D. Unit) - lbs. (kg) Factory Supplied 5 Line Size - OD Gas in. (mm) 5 Line Size - OD Liq. in. (mm) 5-LBS., 5-OZ. (2.70) YES 7/8 (22.2) 3/8 (9.53) 6-LBS., 3-OZ. (3.0) YES -/8 (28.54) 3/8 (9.53) 7-LBS., 7-OZ. (3.38) YES -/8 (28.54) 3/8 (9.53) 0-LBS., 0-OZ. (4.55) YES -/8 (28.54) 3/8 (9.53) FCCV Restrictor Orifice Size in.(mm).069.075.083.089 Dimensions (H x W x D) Crated - in. - (mm) Uncrated 33.2 x 26.7 x 30.2 (843 x 678 x 767) 33.2 x 26.7 x 30.2 (843 x 678 x 767) H X W X D 38 x 30. x 33.8 (965 x 765 x 859) 46.4 x 35. x 38.7 (79 x 892 x 983) Weight lbs. (kg) Shipping Net 25 (97.7) 95 (88.6) 26 (98.2) 96 (89.) 254 (5.5) 227 (03.2) 298 (35.5) 263 (9.5) NOTES:. RATING CONDITIONS (COOLING): 80F (27C) D.B. 67F (20C) W.B. ENTERING AIR TO INDOOR COILOF APPLICABLE TYPE. 95F (35C) D.B. ENTERING AIR TO OUTDOOR COIL. INDOOR COILAND UNITCONNECTED BY25 FT. (7.62 METERS) TUBING. 2. RATING CONDITIONS (HEATING): 70F (2C) D.B. ENTERING AIR TO INDOOR COIL; 47F (8C) D.B. 43F (6C) W.B. ENTERING AIR TO OUTDOOR COIL. NO SUPPLEMENTARY HEAT INCLUDED. 3. STANDARD AIR - DRY COIL- OUTDOOR 4. THIS VALUE APPROXIMATE. FOR MORE PRECISE VALUE SEE UNITNAMEPLATE AND SERVICE INSTRUCTIONS. 5. MAX. OF 80 FT. (24.38 METERS) TOTALMEASURED LENGTH INCLUDING 60 FT. (8.29 METERS) MAX. LIFTBETWEEN O.D. AND I.D. SECTIONS. 6. THIS VALUE SHOWN FOR COMPRESSOR RLAON THE UNITNAMEPLATE AND ON THIS SPECIFICATION SHEETIS USED TO COMPUTE MINIMUM BRANCH CIRCUIT AMPACITYAND MAX. FUSE SIZE. THE VALUE SHOWN IS THE BRANCH CIRCUITSELECTION CURRENT. 3

Performance Data Fan coil Airflow (CFM) versus. External Static Pressure (in.wg) Table 5 - Indoor Fan performance SPEED LOW MED HIGH EXTRAHIGH MCD52DB AIR FLOW (CFM) 50 200 250 300 350 400 430 500 550 600 0.25 0.24 0.22 0.7 0.00 0.28 0.27 0.26 0.23 0.7 0.06 0.00 0.32 0.32 0.30 0.27 0.23 0.8 0.3 0.00 0.38 0.38 0.36 0.34 0.3 0.27 0.24 0.6 0.08 0.00 SPEED LOW MED HIGH EXTRAHIGH MCD58DB AIR FLOW (CFM) 250 30 370 430 490 550 60 670 730 760 0.26 0.25 0.22 0.4 0.00 0.30 0.29 0.27 0.22 0.4 0.00 0.35 0.33 0.3 0.28 0.23 0.8 0.09 0.00 0.40 0.38 0.36 0.34 0.3 0.27 0.22 0.5 0.06 0.00 SPEED LOW MED HIGH EXTRAHIGH MCD524DB AIR FLOW (CFM) 500 550 600 650 700 750 800 850 900 950 0.25 0.6 0.00 0.39 0.33 0.26 0.6 0.00 0.46 0.43 0.40 0.34 0.25 0.5 0.00 0.54 0.52 0.49 0.45 0.4 0.35 0.28 0.2 0.3 0.00 SPEED LOW MEDIUM HIGHT EXTRAHIGHT MCD530DB AIR FLOW (CFM) 630 660 720 780 840 900 960,020,080,0 0.28 0.24 0.5 0.00 0.34 0.32 0.28 0.22 0. 0.00 0.42 0.4 0.39 0.35 0.30 0.24 0.6 0.00 0.49 0.48 0.46 0.43 0.39 0.35 0.28 0.20 0.07 0.00 SPEED LOW MEDIUM HIGHT EXTRAHIGHT MCD536DB AIR FLOW (CFM) 705 760 85 870 925 980,000,090,40,220 0.26 0.25 0.8 0.00 0.38 0.37 0.35 0.3 0.23 0.06 0.00 0.42 0.4 0.40 0.38 0.34 0.29 0.26 0.2 0.00 0.50 0.49 0.47 0.44 0.4 0.36 0.34 0.24 0.7 0.00

Performance Data Fan coil Airflow (CFM) versus. External Static Pressure (in.wg) Indoor Fan Performance Table MCD048DB SPEED AIR FLOW (CFM),300,350,390,480,570,660,750,840,930 2,020 LOW 0.26 0.26 0.25 0.9 0.00 MED 0.30 0.30 0.29 0.27 0.24 0.7 0.00 HIGH 0.37 0.37 0.36 0.35 0.32 0.26 0.6 0.00 EXTRAHIGH 0.46 0.46 0.46 0.45 0.43 0.40 0.35 0.26 0.4 0.00 SPEED LOW MED HIGH EXTRAHIGH MCD060DB AIR FLOW (CFM),400,450,500,600,700,800,880 2,000 2,050 2,200 0.32 0.30 0.26 0.5 0.00 0.40 0.39 0.38 0.34 0.25 0. 0.00 0.44 0.44 0.43 0.40 0.37 0.32 0.24 0.08 0.00 0.48 0.48 0.47 0.45 0.42 0.38 0.33 0.25 0.2 0.00 5

Fan Performance Data 0.40 MCD52DB 0.35 ESP(in.w.g) 0.30 0.25 0.20 0.5 0.0 LOW MED HIGH EXTRAHIGH 0.05 0.00 50 250 350 450 550 650 AIR FLOW (CFM) 0.45 MCD58DB ESP(in.w.g) 0.40 0.35 0.30 0.25 0.20 0.5 0.0 0.05 0.00 250 300 350 400 450 500 550 600 650 700 750 AIR FLOW (CFM) LOW MED HIGH EXTRAHIGH 6

Fan Performance Data 0.60 MCD524DB 0.50 ESP(in.w.g) 0.40 0.30 0.20 LOW MED HIGH EXTRAHIGH 0.0 0.00 500 600 700 800 900,000 AIR FLOW (CFM) 0.60 MCD530DB 0.50 ESP(in.w.g) 0.40 0.30 0.20 LOW MEDIUM HIGHT EXTRAHIGHT 0.0 0.00 630 730 830 930,030,30 AIR FLOW (CFM) 7

Fan Performance Data 0.60 MCD536DB 0.50 ESP(in.w.g) 0.40 0.30 0.20 0.0 LOW MEDIUM HIGHT EXTRAHIGHT 0.00 700 800 900,000,00,200,300 AIR FLOW (CFM) 0.50 MCD048DB ESP(in.w.g) 0.45 0.40 0.35 0.30 0.25 0.20 0.5 0.0 0.05 0.00,300,400,500,600,700,800,900 2,000 2,00 AIR FLOW (CFM) LOW MED HIGH EXTRAHIGH 8

Fan Performance Data 0.60 MCD060DB 0.50 ESP(in.w.g) 0.40 0.30 0.20 LOW MED HIGH EXTRAHIGH 0.0 0.00,400,500,600,700,800,900 2,000 2,00 2,200 2,300 AIR FLOW (CFM)

Performance Data Cooling 2TTB052AA WITH MCD52DBP AT 300 CFM ** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 59.0 8.2 8.8 9.3 9.9 0.5 0.96 85 63 2.0 7.2 7.7 8.3 8.9 9.4.00 67 3. 6.0 6.6 7. 7.7 8.9.04 7 4.2 4.8 5.4 6.0 6.5 7..08 59.0 8.2 8.8 9.3 9.9 0.5.0 90 63 2. 7.2 7.8 8.3 8.9 9.5.05 67 3. 6.0 6.6 7.2 7.7 8.7.09 7 4.3 4.8 5.4 6.0 6.5 7..03 59.0 8.2 8.8 9.3 9.9 0.5.06 95 63 2. 7.2 7.8 8.3 8.9 9.5.0 67 3.2 6.0 6.6 7.2 7.7 8.3.4 7 4.3 4.8 5.4 6.0 6.6 7..8 59.0 8.2 8.7 9.3 9.9 0.4.2 00 63 2.0 7.2 7.7 8.3 8.9 9.4.6 67 3. 6.0 6.6 7. 7.7 8.3.20 7 4.2 4.8 5.4 5.9 6.5 7..24 59 0.9 8. 8.7 9.3 9.8 0.4.9 05 63.9 7. 7.7 8.3 8.8 9.4.22 67 3.0 6.0 6.5 7. 7.7 8.2.26 7 4. 4.8 5.3 5.9 3.5 7..3 59 0.7 8. 8.6 9.2 9.8 0.3.3 5 63.7 7. 7.6 8.2 8.8 9.3.35 67 2.8 5.9 6.5 7.0 7.6 8.2.39 7 3.9 4.7 5.3 5.8 6.4 7.0.43 VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY= 3200 BTUH AIRFLOW = 300 CFM COMPRESSOR POWER = 42 WATTS I.D. FAN POWER = 90 WATTS O.D. FAN POWER = 30 WATTS E.E.R. = 9.46 BTUH/WATT CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 250 350 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.94 x.07 2TTB052AA WITH MCD58DBP AT 450 CFM ** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 59 3..4 2.3 3. 3.4* 3.8* 0.99 85 63 4.2 9.9 0.7.6 2.4 3.2.03 67 5.4 8.2 9.0 9.8 0.7.5.07 7 6.6 6.5 7.3 8. 8.9 9.7.2 59 3..4 2.2 3.0 3.4* 3.7*.04 90 63 4.2 9.9 0.7.5 2.3 3.2.08 67 5.4 8.2 9.0 9.8 0.6.4.3 7 6.6 6.4 7.2 8. 8.9 9.7.7 59 3.0.4 2.2 3.0* 3.4* 3.7*.0 95 63 4. 9.9 0.7.5 2.3 3..4 67 5.3 8.2 9.0 9.8 0.6.4.8 7 6.5 6.4 7.2 8.0 8.8 9.7.23 59 2.6.2 2.0 2.7* 3.0* 3.4*.4 00 63 3.7 9.7 0.5.3 2. 2.9.8 67 4.8 7.9 8.8 9.6 0.4.2.23 7 6.0 6.2 7.0 7.8 8.6 9.4.27 59 2.2.0.8 2.3* 2.7* 3.0*.9 05 63 3.2 9.4 0.2..9 2.7.23 67 4.3 7.7 8.5 9.3 0.2.0.27 7 5.4 5.9 6.8 7.6 8.4 9.2.32 59.3 0.5.3*.6*.9* 2.3*.28 5 63 2.3 9.0 9.8 0.6.4 2.2.32 67 3.3 7.3 8. 8.9 9.7 0.5.36 7 4.3 5.5 6.3 7. 7.9 8.7.40 59 0.9 0.3.0*.3*.6*.9*.33 20 63.8 8.8 9.6 0.4.2.9*.37 67 2.8 7.0 7.9 8.7 9.5 0.3.4 7 3.8 5.3 6. 6.9 7.7 8.5.45 VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY= 5300 BTUH AIRFLOW = 450 CFM COMPRESSOR POWER = 83 WATTS I.D. FAN POWER = 0 WATTS O.D. FAN POWER = 30 WATTS S.E.E.R. = 0.27 BTUH/WATT E.E.R. = 0.75 BTUH/WATT CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 400 500 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.04 TOTALAND SENSIBLE CAPACITY GROSS CAPACITYIN BTUH/000 * DRY COILCONDITION (TOTALCAPACITY= SENSIBLE CAPACITY) TOTAL CAPACITY, COMP. KW ARE VALID ONLY FOR WET COIL ALLTEMPERATURES IN DEGREES F ** NOMINALCFM 20

Performance Data Cooling 2TTB058AA WITH MCD58DBP AT 450 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 59 5.5 2.5 3.3 4. 4.9 5.6*.32 85 63 6.8..9 2.7 3.5 4.3.37 67 8. 9.4 0.2.0.8 2.6.42 7 9.6 7.6 8.4 9.2 0.0 0.8.47 59 5.5 2.5 3.3 4.2 5.0 5.6*.39 90 63 6.8..9 2.7 3.5 4.3.44 67 8.2 9.4 0.2.0.8 2.6.49 7 9.6 7.6 8.4 9.3 0. 0.9.54 59 5.5 2.6 3.4 4.2 5.0 5.6*.46 95 63 6.8..9 2.7 3.5 4.3.5 67 8.2 9.4 0.2.0.8 2.6.56 7 9.6 7.7 8.5 9.3 0. 0.9.62 59 5.0 2.3 3. 3.9 4.7 5.2*.5 00 63 6.3 0.8.6 2.4 3.2 4.0.56 67 7.6 9. 9.9 0.7.5 2.3.6 7 9.0 7.4 8.2 9.0 9.8 0.6.66 59 4.5 2.0 2.8 3.6 4.4 4.8*.56 05 63 5.7 0.5.3 2.2 3.0 3.8.6 67 7.0 8.9 9.7 0.5.3 2..66 7 8.4 7. 7.9 8.7 9.5 0.3.7 59 3.4.5 2.3 3. 3.6* 4.0*.66 5 63 4.6 0.0 0.8.6 2.4 3.2.7 67 5.8 8.3 9. 9.9 0.7.5.75 7 7. 6.6 7.4 8.2 9.0 9.8.80 59 2.9.2 2.0 2.8 3.2* 3.6*.7 20 63 4. 9.7 0.5.4 2.2 3.0.76 67 5.2 8. 8.9 9.7 0.5.3.80 7 6.4 6.3 7. 7.9 8.7 9.5.85 VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY= 8200 BTUH AIRFLOW = 450 CFM COMPRESSOR POWER = 562 WATTS I.D. FAN POWER = 0 WATTS O.D. FAN POWER = 30 WATTS S.E.E.R. = 9.65 BTUH/WATT E.E.R. = 0.0 BTUH/WATT CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 400 500 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.04 2TTB058AA WITH MCD524DBP AT 600 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 59 6.6 3.9 5. 6.2 6.9* 7.4*.38 85 63 8.0.7 2.9 4.0 5.2 46.3.43 67 9.4 9.3 0.4.6 2.7 3.9.48 7 20.9 6.8 8.0 9. 0.2.4.53 59 6.4 3.9 5.0 6. 6.8* 9.2*.45 90 63 7.8.7 2.8 3.9 5. 6.2.5 67 9.2 9.2 0.4.5 2.6 3.8.55 7 20.6 6.7 7.9 9.0 0.2.3.60 59 6.3 3.6 4.9 6. 6.7* 7.*.5 95 63 7.6.6 2.7 3.9 5.0 6..56 67 9.0 9.2 0.3.4 2.6 3.7.62 7 20.6 6.7 7.8 8.9 0..2.67 59 5.8 3.6 4.7 2.9* 6.3* 6.7*.58 00 63 7..4 2.5 3.7 4.8 6.0.63 67 8.5 9.0 0..2 2.4 3.5.69 7 9.9 6.5 7.6 8.7 9.9.0.74 59 5.4 3.4 4.6 5.5* 5.9* 6.3*.65 05 63 6.6.2 2.4 3.5 4.6 5.8.70 67 8.0 8.8 9.9. 2.2 3.3.76 7 9.3 6.3 7.4 8.6 9.7 0.8.8 59 4.5 3. 4.2 4.8* 5.2* 5.6*.80 5 63 5.7 0.9 2.4 3. 4.3 5.4.85 67 6.9 8.4 9.5 0.7.8 3.0.90 7 8.2 5.9 7. 8.2 9.3 0.5.96 VALUES AT 95/80/67 RATING CONDITIONS GROSS CAPACITY= 9000 BTUH AIRFLOW = 600 CFM COMPRESSOR POWER = 63 WATTS I.D. FAN POWER = 90 WATTS O.D. FAN POWER = 30 WATTS E.E.R. = 9.44 BTUH/WATT CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 525 675 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.04 TOTALAND SENSIBLE CAPACITY GROSS CAPACITYIN BTUH/000 * DRY COILCONDITION (TOTALCAPACITY= SENSIBLE CAPACITY) TOTALCAPACITY, COMP. KW ARE VALID ONLY FOR WET COIL ALLTEMPERATURES IN DEGREES F ** NOMINALCFM 2

Performance Data Cooling 2TTB0524AA WITH MCD524DBP AT 600 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 22. 5.4 6.7 8.0 9.2 20.0.79 85 65 23.8 2.7 4. 5.3 6.7 8.0.86 67 24.7.3 2.6 4.0 5.3 6.6.90 7 26.6 8.5 9.8. 2.4 3.7.97 6 2.5 5.2 6.4 7.8 8.9 20.0.94 95 65 23. 2.5 3.8 5. 6.4 7.7 2.02 67 24.0. 2.4 3.7 5.0 6.3 2.06 7 25.8 8.3 9.5 0.9 2. 3.5 2.4 6 20.6 4.6 5.9 7. 8.2 9.2 2. 05 65 22.2 2.0 3.3 4.6 5.8 7.2 2.9 67 23. 0.6.8 3.2 4.5 5.8 2.23 7 24.8 9. 9. 0.4.7 3.0 2.32 6 9.7 4.2 5.4 6.6 7.7 8.6 2.29 5 65 2.3.5 2.8 4. 5.4 6.7 2.37 67 22. 0..5 2.7 4. 5.3 2.42 7 23.7 7.4 8.6 9.9.2 2.5 2.50 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 24.0 MBH AIRFLOW: 600 CFM SYSTEM POWER: 2404 WATTS EER (BTU/W-HR): 0.0 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 525 675 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.04 2TTB0524AA WITH MCD530DBP AT 750 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 22.8 7.2 8.7 20. 2.5 22.3.79 85 65 24.6 4.2 5.7 7. 8.6 20.0.87 67 25.6 2.7 4. 5.6 7.0 8.5.90 7 27.5 9.5.0 2.4 3.9 5.3.98 6 22.2 6.9 8.3 9.8 2. 22.3*.95 95 65 23.9 3.9 5.4 6.9 8.3 9.8 2.02 67 24.8 2.3 3.8 5.3 6.7 8.2 2.07 7 26.7 9.2 0.6 2. 3.5 5. 2.5 6 2.3 6.3 7.7 9. 20.3 2.5* 2.2 05 65 23.0 3.4 4.8 6.3 7.7 9.2 2.20 67 23.9.8 3.2 4.7 6. 7.6 2.24 7 25.6 0. 0.2.6 3. 4.5 2.33 6 20.4 5.8 7.2 8.5 9.7 20.8* 2.29 5 65 22.0 2.9 4.3 5.8 7.2 8.6 2.38 67 22.8.3 2.8 4.2 5.7 7. 2.42 7 24.5 8.2 9.6. 2.6 4.0 2.5 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 24.8 MBH AIRFLOW: 750 CFM SYSTEM POWER: 242 WATTS EER (BTU/W-HR): 0.2 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 700 800 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.02 TOTALAND SENSIBLE CAPACITY GROSS CAPACITYIN BTUH/000 * DRY COILCONDITION (TOTAL CAPACITY= SENSIBLE CAPACITY) TOTALCAPACITY, COMP. KW ARE VALID ONLY FOR WET COIL ALLTEMPERATURES IN DEGREES F ** NOMINALCFM 22

Performance Data Cooling 2TTB0530AA WITH MCD524DBP AT 600 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 24.5 6.6 8. 9.4 20.8 2.6 2.8 85 65 26.4 3.7 5.2 6.6 8.0 9.4 2.27 67 27.4 2.2 3.7 5. 6.5 7.9 2.3 7 29.5 9. 0.6 2.0 3.4 4.8 2.4 6 23.8 6.4 7.7 9.2 20.4 2.5 2.37 95 65 25.6 3.5 4.9 6.3 7.7 9. 2.46 67 26.6.9 3.4 4.8 6.2 7.6 2.5 7 28.6 8.9 0.3.7 3. 4.6 2.6 6 22.8 5.7 7.2 8.5 9.6 20.8 2.58 05 65 24.6 2.9 4.3 5.7 7. 8.5 2.68 67 25.6.4 2.8 4.2 5.6 7.0 2.73 7 27.4 9.8 9.8.2 2.6 4.0 2.83 6 2.8 5.3 6.7 7.9 9. 20. 2.79 5 65 23.6 2.4 3.9 5.2 6.7 8.0 2.90 67 24.5 0.9 2.4 3.7 5.2 6.5 2.95 7 26.3 8.0 9.3 0.7 2. 3.5 3.05 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 26.6 MBH AIRFLOW: 600 CFM SYSTEM POWER: 2860 WATTS EER (BTU/W-HR): 9.3 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 525 675 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.04 2TTB0530AAWITH MCD530DBP AT 750 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 25.7 8.2 9.8 2.3 22.8 23.6 2.8 85 65 27.7 5. 6.6 8.2 9.7 2.3 2.27 67 28.8 3.4 5.0 6.5 8. 9.6 2.32 7 30.9 0.0.6 3. 4.7 6.3 2.4 6 24.9 8.0 9.4 2.0 22.3 23.6 2.37 95 65 26.9 4.8 6.3 7.9 9.4 2.0 2.46 67 27.9 3. 4.7 6.2 7.8 9.3 2.52 7 30.0 9.8.3 2.9 4.4 6.0 2.6 6 23.9 7.3 8.8 20.3 2.5 22.8 2.58 05 65 25.8 4.2 5.7 7.3 8.8 20.3 2.68 67 26.9 2.5 4.0 5.6 7. 8.7 2.73 7 28.8 0.7 0.8 2.3 3.9 5.4 2.84 6 22.9 6.8 8.3 9.7 20.9 22.0 2.79 5 65 24.7 3.6 5.2 6.7 8.3 9.8 2.90 67 25.7 2.0 3.6 5. 6.6 8. 2.95 7 27.6 8.7 0.2.8 3.3 4.8 3.06 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 27.9 MBH AIRFLOW: 750 CFM SYSTEM POWER: 2894 WATTS EER (BTU/W-HR): 9.6 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 700 800 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.02 TOTALAND SENSIBLE CAPACITY GROSS CAPACITYIN BTUH/000 * DRY COILCONDITION (TOTALCAPACITY= SENSIBLE CAPACITY) TOTALCAPACITY, COMP. KW ARE VALID ONLY FOR WET COIL ALLTEMPERATURES IN DEGREES F ** NOMINALCFM 23

Performance Data Cooling 2TTB0536AA WITH MCD530DBPAT 750 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 30.2 20.4 22.2 23.8 25.5 26.4 2.48 85 65 32.6 6.9 8.6 20.3 22. 23.8 2.58 67 33.8 5.0 6.8 8.5 20.2 22.0 2.63 7 36.3.2 3.0 4.7 6.5 8.2 2.74 6 29.3 20. 2.8 23.5 25.0 26.4 2.69 95 65 3.6 6.5 8.2 20.0 2.7 23.5 2.80 67 32.8 4.6 6.4 8. 9.9 2.6 2.85 7 35.3 0.9 2.6 4.4 6. 7.9 2.96 6 28. 9.3 2. 22.7 24. 25.5 2.93 05 65 30.4 5.9 7.6 9.3 2.0 22.7 3.04 67 3.6 4.0 5.7 7.5 9.2 20.9 3.0 7 33.8 2.0 2.0 3.7 5.5 7.2 3.22 6 26.9 8.8 20.5 22.0 23.4 24.6 3.7 5 65 29. 5.3 7.0 8.7 20.4 22. 3.29 67 30.2 3.4 5.2 6.9 8.6 20.3 3.35 7 32.4 9.8.4 3.2 4.9 6.6 3.47 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 32.8 MBH AIRFLOW: 750 CFM SYSTEM POWER: 3270 WATTS EER (BTU/W-HR): 0.0 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 700 800 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.02 2TTB0536AA WITH MCD536DBP AT 900 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 3.3 22. 24.0 25.8 27.6 28.7 2.47 85 65 33.8 8.3 20.2 22.0 23.9 25.8 2.57 67 35. 6.3 8.2 20. 2.9 23.8 2.62 7 37.6 2.2 4. 5.9 7.9 9.7 2.73 6 30.4 2.8 23.6 25.5 27. 28.6 2.68 95 65 32.8 7.9 9.7 2.7 23.5 25.4 2.79 67 34.0 5.9 7.8 9.7 2.5 23.4 2.85 7 36.6.9 3.7 5.6 7.4 9.4 2.96 6 29. 20.0 22.8 24.6 26. 27.6 2.92 05 65 3.5 7.2 9.0 20.9 22.7 24.6 3.03 67 32.7 5.2 7.0 8.9 20.7 22.7 3.09 7 35. 3.0 3. 4.9 6.8 8.6 3.2 6 27.9 20.4 22.2 23.8 25.4 26.7 3.6 5 65 30. 6.5 8.4 20.3 22.2 24.0 3.29 67 3.3 4.5 6.5 8.3 20.2 22.0 3.34 7 33.6 0.6 2.4 4.3 6. 8.0 3.46 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 34.0 MBH AIRFLOW: 900 CFM SYSTEM POWER: 3284 WATTS EER (BTU/W-HR): 0.4 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 750 975 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.07 TOTALAND SENSIBLE CAPACITY GROSS CAPACITYIN BTUH/000 * DRY COILCONDITION (TOTALCAPACITY= SENSIBLE CAPACITY) TOTALCAPACITY, COMP. KW ARE VALID ONLY FOR WET COIL ALLTEMPERATURES IN DEGREES F ** NOMINALCFM 24

Performance Data Cooling 2TTA0040AD WITH MCD536DBP AT 900 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 33.7 23.2 25.2 27. 29.0 30. 2.85 85 65 36.3 9.2 2.2 23.2 25.2 27. 2.97 67 37.7 7. 9. 2. 23.0 25.0 3.02 7 40.5 2.8 4.8 6.7 8.8 20.7 3.5 6 32.7 22.9 24.8 26.8 28.5 30. 3.09 95 65 35.3 8.8 20.8 22.8 24.7 26.7 3.22 67 36.6 6.7 8.7 20.7 22.6 24.6 3.28 7 39.3 2.5 4.4 6.4 8.3 20.4 3.4 6 3.4 22.0 24.0 25.8 27.4 29.0 3.37 05 65 33.9 8. 20.0 22.0 23.9 25.9 3.50 67 35.2 6.0 7.9 9.9 2.8 23.8 3.57 7 37.7 3.7 3.7 5.6 7.7 9.6 3.7 6 30.0 2.4 23.3 25.0 26.7 28.0 3.65 5 65 32.4 7.4 9.4 2.3 23.3 25.2 3.79 67 33.7 5.3 7.3 9.2 2.2 23. 3.86 7 36.2. 3.0 5.0 7.0 8.9 3.99 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 36.6 MBH AIRFLOW: 900 CFM SYSTEM POWER: 3709 WATTS EER (BTU/W-HR): 9.9 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 750 975 TOTALCAP. x 0.99 x.0 SENS. CAP. x 0.96 x.07 2TTA0040AD WITH MCD048DBP AT 600 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 36. 30.4 33.0 35.5 38.0* 39.4* 2.97 85 65 38.9 25. 27.8 30.3 32.9 35.5 3.09 67 40.4 22.4 25.0 27.6 30. 32.7 3.5 7 43.4 6.7 9.4 2.9 24.6 27. 3.28 6 35.0 30.0 32.4 35.* 37.2* 39.4* 3.22 95 65 37.8 24.7 27.2 29.8 32.3 35.0 3.35 67 39.2 2.8 24.5 27.0 29.6 32.2 3.42 7 42. 6.3 8.8 2.5 24.0 26.7 3.55 6 33.6 28.8 3.4 33.8* 35.9* 38.0* 3.5 05 65 36.3 23.6 26.2 28.8 3.3 33.9 3.65 67 37.7 20.9 23.4 26.0 28.6 3.2 3.7 7 40.4 7.9 8.0 20.5 23. 25.6 3.86 6 32.2 28.0 30.5 32.8* 34.9* 36.7* 3.80 5 65 34.7 22.8 25.4 27.9 30.5 33.0 3.95 67 36. 20.0 22.7 25. 27.8 30.3 4.02 7 38.8 4.6 7. 9.6 22.2 24.8 4.6 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 39.2 MBH AIRFLOW: 600 CFM SYSTEM POWER: 4205 WATTS EER (BTU/W-HR): 9.3 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 400 625 TOTALCAP. x 0.99 x.00 SENS. CAP. x 0.96 x.0 TOTALAND SENSIBLE CAPACITY GROSS CAPACITYIN BTUH/000 * DRY COILCONDITION (TOTALCAPACITY= SENSIBLE CAPACITY) TOTALCAPACITY, COMP. KW ARE VALID ONLY FOR WET COIL ALLTEMPERATURES IN DEGREES F ** NOMINALCFM 25

Performance Data Cooling 2TTA0050AD WITH MCD048DBP AT 600 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 45.2 34.3 37.4 40.2 42.9 44.6 3.78 85 65 48.7 28.4 3.4 34.3 37.2 40. 3.93 67 50.6 25.3 28.2 3.2 34. 37.0 4.0 7 54.4 8.9 2.9 24.7 27.8 30.7 4.7 6 43.9 33.9 36.7 39.7 42. 44.6* 4.0 95 65 47.3 27.9 30.7 33.7 36.6 39.5 4.26 67 49. 24.7 27.7 30.6 33.5 36.4 4.35 7 52.8 8.4 2.3 24.3 27. 30.2 4.52 6 42. 32.6 35.5 38.2 40.6 42.9* 4.47 05 65 45.5 26.7 29.6 32.5 35.4 38.3 4.64 67 47.3 23.6 26.5 29.4 32.3 35.2 4.73 7 50.6 20.2 20.3 23. 26. 29.0 4.9 6 40.3 3.7 34.5 37. 39.5 4.5 4.83 5 65 43.5 25.7 28.7 3.5 34.5 37.3 5.02 67 45.2 22.6 25.7 28.4 3.4 34.2 5. 7 48.6 6.5 9.3 22.2 25. 28.0 5.29 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 49. MBH AIRFLOW: 600 CFM SYSTEM POWER: 578 WATTS EER (BTU/W-HR): 9.5 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 400 625 TOTALCAP. x 0.99 x.00 SENS. CAP. x 0.96 x.0 2TTA0050AD WITH MCD060DBP AT 2000 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 48.7 40.5 44. 47.4 50.7* 52.7* 3.92 85 65 52.6 33.6 37. 40.5 44.0 47.4 4.08 67 54.6 29.9 33.4 36.9 40.2 43.7 4.6 7 58.7 22.3 25.9 29.2 32.8 36.2 4.33 6 47.4 40.0 43.3 46.8 49.7* 52.6* 4.25 95 65 5. 32.9 36.3 39.8 43.2 46.7 4.42 67 53.0 29.2 32.7 36. 39.6 43.0 4.5 7 57.0 2.8 25. 28.7 32.0 35.6 4.69 6 45.4 38.5 4.9 45.2 48.0* 50.7* 4.63 05 65 49. 3.6 35.0 38.4 4.8 45.3 4.8 67 5.0 27.9 3.3 34.8 38. 4.6 4.90 7 54.7 23.9 24.0 27.3 30.9 34.2 5.0 6 43.5 37.4 40.7 43.8* 46.6* 49.0* 5.0 5 65 47.0 30.4 33.9 37.2 40.7 44. 5.2 67 48.8 26.7 30.3 33.5 37. 40.4 5.30 7 52.4 9.4 22.8 26.2 29.7 33. 5.49 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 53.0 MBH AIRFLOW: 2000 CFM SYSTEM POWER: 5390 WATTS EER (BTU/W-HR): 9.8 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 750 2250 TOTALCAP. x 0.99 x.00 SENS. CAP. x 0.95 x.05 TOTALAND SENSIBLE CAPACITY GROSS CAPACITYIN BTUH/000 * DRY COILCONDITION (TOTALCAPACITY= SENSIBLE CAPACITY) TOTALCAPACITY, COMP. KW ARE VALID ONLY FOR WET COIL ALLTEMPERATURES IN DEGREES F ** NOMINALCFM 26

Performance Data Cooling 2TTA0060AD WITH MCD060DBP AT 2000 CFM** GROSS CAPACITY IN BTU/H X 000 O.D. I.D. GROSS SENS. CAP. AT ENTERING D.B. TEMP. COMPR. D.B. W.B. CAP. 72 74 76 78 80 KW 6 56.0 43. 46.9 50.4 53.9 56.0 4.38 65 60.5 35.7 39.4 43.0 46.8 50.3 4.56 67 62.8 3.8 35.5 39.2 42.8 46.5 4.64 7 67.4 23.7 27.5 3. 34.9 38.5 4.84 6 54.4 42.5 46.0 49.8 52.9 55.9* 4.75 95 65 58.7 35.0 38.6 42.3 45.9 49.6 4.94 67 60.9 3.0 34.7 38.4 42.0 45.7 5.04 7 65.5 23. 26.7 30.5 34.0 37.9 5.24 6 52.2 40.9 44.6 48.0 5.0 53.9* 5.8 05 65 56.4 33.5 37.2 40.9 44.4 48. 5.37 67 58.6 29.7 33.2 36.9 40.5 44.2 5.48 7 62.8 25.4 25.5 29. 32.8 36.4 5.69 6 50.0 39.8 43.3 46.5 49.6 52.* 5.60 5 65 54.0 32.3 36.0 39.6 43.3 46.8 5.82 67 56.0 28.4 32.2 35.7 39.4 43.0 5.92 7 60.2 20.7 24.2 27.8 3.5 35. 6.3 * Dry coil condition (Gross Capacity = Sensible Capacity) Gross Capacity and Comp. KW are valid only for Wet Coil Performance at the Rating Conditions of 80/67 & 95 F GROSS CAPACITY: 60.9 MBH AIRFLOW: 2000 CFM SYSTEM POWER: 5986 WATTS EER (BTU/W-HR): 0.2 CORRECTION FACTORS - OTHER AIRFLOWS (Multiply or Add as indicated) AIRFLOW 750 2250 TOTALCAP. x 0.99 x.00 SENS. CAP. x 0.95 x.05 TOTALAND SENSIBLE CAPACITY GROSS CAPACITYIN BTUH/000 * DRY COILCONDITION (TOTALCAPACITY= SENSIBLE CAPACITY) TOTALCAPACITY, COMP. KW ARE VALID ONLY FOR WET COIL ALLTEMPERATURES IN DEGREES F ** NOMINALCFM 27

MCD Wiring Diagram COOLING ONLY MCD52-536 MCD048-060 28

MCD Wiring Diagram COOLING HEATING MCD52-524DB 29

MCD Wiring Diagram COOLING HEATING MCD530-536DB MCD048-060DB 30

Wiring Diagram 2TTB052AA000D 2TTB058AA000D 3

Wiring Diagram 2TTB058AA000D 2TTB0524AA000C 32

Wiring Diagram 2TTB0530AA000C 2TTB0536AA000C 33

Wiring Diagram 2TTA0040AD000B 2TTA0050AD000B 34

Wiring Diagram 2TTA0060AD000B 2TTB05-MCD-D TO POWER SUPPLY 230//50 230//50 MINI-SPLIT OUTDOOR UNIT SEE INDOOR UNIT DIAGRAM FOR CONNECTION MARKINGS 230 VAC CONTROL WIRING FROM OUT- DOOR TO POWER SUPPLY 230//50 230//50 NOTES :. POWER WIRING AND GROUNDING OF EQUIPMENT MUSTCOMPLY WITH LOCALCODES. 2. INSURE THAT POWER SUPPLY AGREES WITH EQUIPMENTNAME PLATE. 3. USE ONLY COPPER CONDUCTORS. 35

MCD Dimensional Data OUTLINE DIMENSION MCD52-536DB 36

MCD Dimensional Data OUTLINE DIMENSION MCD52-536DB 37

MCD Dimensional Data OUTLINE DIMENSION MCD048-60DB 38

Dimensions 2TTB0 Outline Drawing Note:All dimensions are in inches (mm) Model A B C D E F G H J K 2TTB052AA 648 (25-/2) 502 (9-3/4) 476 (8-3/4) 5/8 /4 49 (5-7/8) 9 (3/4) 89 (3-/2) 6 (5/8) 460 (8-/8) 2TTB058AA 648 (25-/2) 502 (9-3/4) 476 (8-3/4) 5/8 /4 49 (5-7/8) 9 (3/4) 89 (3-/2) 6 (5/8) 460 (8-/8) 2TTB0524AA 56 (25-5/8) 724 (28-/2) 65 (25-5/8) 3/4 5/6 27 (5) 57 (2-/4) 8 (7-/8) 44 (-3/4) 457 (8) 2TTB0530AA 56 (25-5/8) 724 (28-/2) 65 (25-5/8) 3/4 5/6 27 (5) 57 (2-/4) 8 (7-/8) 44 (-3/4) 457 (8) 2TTB0536AA 730 (28-3/4) 724 (28-/2) 65 (25-5/8) 3/4 5/6 37 (5-3/8) 65 (2-8/8) 20 (8-/4) 57 (2-/4) 457 (8) 39

Dimensions 2TTA0 Outline Drawing Note:All dimensions are in inches (mm) Model A B C D E F G H J K 2TTA0040AD 730 (28-3/4) 724 (28-/2) 65 (25-5/8) -/8 3/8 37 (5-3/8) 65 (2-8/8) 20 (8-/4) 57 (2-/4) 457 (8) 2TTA0050AD 832 (32-3/4) 829 (32-5/8) 756 (29-3/4) -/8 3/8 43 (5-5/8) 92 (3-5/8) 20 (8-/4) 79 (3-/8) 508 (20) 2TTA0060AD 045 (4-/8) 946 (37-/4) 870 (34-/4) -/8 3/8 52 (6) 98 (3-7/8) 29 (8-5/8) 86 (3-3/8) 508 (20) 40

Mechanical Specification Options Condensing Units General The unit shall be fully charged from the factory for matched indoor section and up to 5 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 5 F. Cooling capacities shall be matched with a wide selection of air handlers. Exterior must be designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Corrosion and weatherproof CMBP-G30 Duratuff base.(2ttb/2tta) Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer. Compressor The Climatuff compressor features internal over temperature and pressure protector, total dipped hermetic motor and thermostatically controlled sump heater. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. Condenser Coil The Spine Fin coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55 F. The addition of an evaporator defrost control permits operation to 40 F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30 F. Accessories Thermostats Heating/Cooling (manual and automatic changeover). Sub-base to match thermostat and locking thermostat cover. Evaporator Defrost Control See Low Ambient Cooling. Outdoor Thermostat Supplemental heat outdoor ambient lockout from 46 to 0 F. 4

Trane www.trane.com For more information, contact your local district office Literature Order Number: Date: Supersedes: Stocking Location: SS-PRC039-EN August, 203 XXXXXX Dubai, UAE Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.