This part list contains the service parts for the Eclipse 00, 00, and 800 systems. D series models began early 0 The models that are covered include: EH0 C & D EH0 C & D ECC00 ECC00 ECC800 Contents Head voltage is independent of the condensing unit voltage. Voltage codes: - = /60/ - = 08-0/60/ -6 = 0/0/ - = 08-0/60/ EH0 C Cabinet... EH0 C Cabinet... EH0 D Cabinet... EH0 D Cabinet... EH0 EH0 C or D Interior Parts... 6 EH0 and EH0 C or D Refrigeration... EH0 C or D Evaporator Compartment... 8 EH0 C or D Evaporator Compartment... 9 EH0 or EH0 C or D Electrical... 0 ECC Cabinet and Fan... ECC Refrigeration Components... ECC Compressors... ECC00, ECC0 and ECC800 Control Box... EH0 C or EH0 C Schematic Diagram... EH0 C or EH0 C iring DIagram... 6 EH0 D or EH0 D Schematic Diagram... EH0 D or EH0 D iring DIagram... 8 ECC00 and ECC0 Single Phase iring Diagram... 9 ECC00 and ECC0 Single Phase Schematic Diagram... 0 ECC00, ECC0 and ECC800 Three Phase iring Diagram... ECC00, ECC0 and ECC800 Three Phase Schematic Diagram... May 0 Page
EH0 C Cabinet b a 0 8 8a 6a a 6 9 Item Part A99-0 Top panel 0-0-0 Evaporator cover a 0-0-0 Screw 0-80-0 Screw receptacle A98-0 Front panel assembly, includes trim strip and labels. a 0-6-0 Top gusset 0--0 Screw, front panel 6 0-8-0 Bezel, full window 6a 0-8-0 Bezel, partial window** May 0 Page 0--0 Trim strip 8 A98-0 Right side panel assy 8a 0--0 Receptacle 9 A9-00 Panel clip 0 0-0- Screw A09-0 Machine straps 6-0-00 Inlet water fitting, flare** A980-0 Left side panel 0-0- Screw -09-0 Gasket tape ** Optional
EH0 C Cabinet b a 0 8 8a 6a a 6 9 Item Part A99-0 Top panel, w/trim strips 0-0-0 Evaporator cover a 0-0-0 Screw 0-80-0 Screw receptacle A98-0 Front panel assembly, includes trim strip and labels. a 0-6-0 Top gusset 0--0 Screw, front panel 6 0-8-0 Bezel, full window 6a 0-8-0 Bezel, partial window* May 0 Page 0--0 Trim strip 8 A98-0 Right side panel assy 8a 0--0 Receptacle 9 A9-00 Panel clip 0 0-0- Screw A09-0 Machine straps 6-0-00 Inlet water fitting, flare* A980-0 Left side panel 0-0- Screw -09-0 Gasket * Optional
EH0 D Cabinet 6 0 6 0 0 8 9 8 Item Part A00-0 Left side panel assy A009-0 Top Panel 0-89-0 Trim Strip Top 0-0-0 Inner Front Panel 0-0-0 Thumbscrew 6 A008-0 Front panel assembly, includes trim strip and labels. A0-0 Right side panel assy 8 0-80-0 Trim Strip Bottom 0 9 0-8-0 Bezel ith Standard Door 9A 0-8-0 Bezel ith Secure Door** 0 0-0-0 Screw #8 X / 0-86-0 Screw #8 X /8 0-8-0 Spacer. Id X.8 Od 0--0 Screw, Front Panel 0-8- *Panel mount kit, left a 0-8- *Panel mount kit, right *Includes both screw receptacles A09-0 Machine straps 6 6-0-00 Inlet water fitting, flare** 0-0- Screw 8-06- Light & switch panel D ** Optional April 06 Page
EH0 D Cabinet 6 0 6 0 0 8 9 8 Item Part A00-0 Left side panel assy A009-0 Top Panel 0-89-0 Trim Strip Top 0-0-0 Inner Front Panel 0-0-0 Thumbscrew 6 A008-0 Front panel assembly, includes trim strip and labels. A0-0 Right side panel assy 8 0-80-0 Trim Strip Bottom 0 9 0-8-0 Bezel ith Standard Door 9A 0-8-0 Bezel ith Secure Door** 0 0-0-0 Screw #8 X / 0-86-0 Screw #8 X /8 0-8-0 Spacer. Id X.8 Od 0--0 Screw, Front Panel 0-8- *Panel mount kit, left a 0-8- *Panel mount kit, right *Includes both screw receptacles A09-0 Machine straps 6 6-0-00 Inlet water fitting, flare** 0-0- Screw 8-06- Light & switch panel D ** Optional April 06 Page
EH0 EH0 C or D Interior Parts 9 8 6 9 0 8 6 Item Part -9-0 Inlet water sol valve -06-0 Tubing, order (ft) -060- Harvest assist -0- Temp sensor set 0--0 Sump cover, rt 6-98-0 LS harness 0-8-0 ater pump hose, EH0 0-0-0 ater pump hose, EH0 8 0-66-0 LS cover 9-90- ater pump 0 A900-0 ater level sensor 0-69-0 Sump cover 0--0 Pump bracket A886-00 Tube -06-0 Purge valve 6 A886-00 Tube, out 0-69- Drain fitting 8 A880-00 Brace 9 A896-00 Chase May 0 Page 6
EH0 and EH0 C or D Refrigeration Item Part -09-0 Vapor valve 6-0-0 TXV - EH0 6--0 TXV - EH0 9-099-06 Insulation for TXV\ 6--0 Access valve seat 6-0-0 Access valve cap 6-9-0 Access valve core May 0 Page
EH0 C or D Evaporator Compartment 9 6 0 a a 8L 8R Item Part 0-06-0 ater distributor cover 0-06-0 ater distributor, left a 0-06-0 ater distributor, right 0-0-0 Mounting bracket, left a 0-0-0 Mounting bracket, right see table Evaporator 0-00- Curtain 8L -06-06 Curtain switch, left 8R -06-0 Curtain switch, right 9-09-0 Gasket tape 0 0-868-0 Screw small cube medium cube Right A86-0 A86-0 Left A86-0 A86-0 A980-00 Back wall 6 A90-0 Ice thickness sensor May 0 Page 8
EH0 C or D Evaporator Compartment 9 6 0 a a 8L 8R Item Part 0-06-0 ater distributor cover 0-06-0 ater distributor, left a 0-06-0 ater distributor, right 0-0-0 Mounting bracket, left a 0-0-0 Mounting bracket, right see table Evaporator small cube medium cube Right A868-0 A868-0 Left A868-0 A868-0 A86-00 Back wall 6 A90-0 Ice thickness sensor 0-6- Curtain 8L -06-06 Curtain switch, left 8R -06-0 Curtain switch, right 9-09-0 Gasket tape 0 0-868-0 Screw November May 0 0 Page 9
EH0 or EH0 C or D Electrical 9 8 6 Item Part -80-0 Terminal strip -06- Service controller, fits all a -00-8 Service controller, thru C -9-0 Transformer -99-0 Relay base A98-00 Cover 6 -- Snap bushing -- Snap bushing 8-99-0 Relay 9-06- Light & switch panel D Not Illustrated: 0-9-0 Low voltage harness - to interconnecting wire -9-0 High voltage harness (has large plug) -90-0 Control power harness -68-9 Power cord May 0 Page 0
ECC Cabinet and Fan a 6 b c 6 6 8 9 Item Part 0-6-0 Screw 0--0 Fan guard, 00, 0 0-0-0 Fan guard, 800 A9-00 Top panel, 00, 0 A9-00 Top panel, 800 8-886-0 Fan blade, 00, 0 8-880-0 Fan blade, 800 6 A000-00 Cover -60-0 Terminal strip, 0 Hz only 8 A8-00 Box cover 9 A009-00 Chase cover 0 A009-00 Valve cover April 0 Page A006-00 Lower cover a b c -6-0 Fan motor, 00, 0 --0 Fan motor, 800 0-0-08 Hex bolt 0-0-06 Flat washer 0-0-0 Lock washer 0-06-08 Nut 0 A98-00 Bracket A009-00 Bracket 6 A99-00 Motor bracket A8-00 Support
ECC Refrigeration Components Compressor See Page 0 0 6 9 8 Item Part 6--0 Access valve seat 6-9-0 Access valve core 8-89- Coil 6-0-0 Access valve cap 6-096- CPR valve -00-0 High pressure cut out switch -06-0 Liquid line inlet valve -00-0 Bypass valve -0- Head master valve 6-09-0 Check valve 6-08-0 Receiver 6 6-08-0 Ball valve / 6-08-0 Ball valve / 8 6-08-0 Ball valve /8 9 0-9-0 Dryer 0 6--0 Accumulator, 00, 0 6--0 Accumulator, 800 October 0 Page
Compressor - see table below ECC Compressors Model Phase Hz Part Number ECC00- single 60 8-80- ECC0- single 60 8-896- ECC0- three 60 8-896- ECC800- three 60 8-890- Single phase 60 Hz compressors include starting components. All include a drier. All have internal overloads 8-0-0 Crankcase heater for 8-80- and 8-80- Mounting parts for compressors: 8-00- Mounting grommet 8-00-6 Sleeve 0-06-0 asher 0-0-0 Cap screw Parts shipped in condensing unit: -86-0 Interconnecting harness May 0 Page
ECC00, ECC0 and ECC800 Control Box 6 Three Phase Control Box Single Phase Control Box Item Part -6-0 Toggle switch -86-0 Transformer, 60 Hz models 0 volt to volt -69-0 Single phase contactor ECC00- ECC0- Comp. Relay 8-90- 8-90- Start Capacitor 8-90- 8-90-9 6 Run Capacitor 8-90- 8-90-69 --0 Contactor, phase May 0 Page
EH0 C or EH0 C Schematic Diagram L L LINE HARVEST ASSIST MOTOR HOT GAS TRANSFORMER V VALVE HARVEST ASSIST MOTOR HOT GAS VALVE HGV RELAY TO COMPRESSOR SECTION CONTACTOR RELAY ATER VALVE ELECTRONIC CONTROL ATER LEVEL SENSOR DISCHARGE TEMP. SUMP TEMP. ICE THICKNESS PROBE CURTAIN SITCH CURTAIN SITCH DUMP VALVE ATER PUMP May 0 Page
6 8 Prodigy Eclipse ECC, EH0 and EH0 C or D Service Parts EH0 C or EH0 C iring DIagram -06-0 USE COPPER CONDUCTORS ONLY BN/ ATER SOLENOID MOT PUMP BN/ HOT GAS SOLENOID BN/ HARV ASSIST M MOTOR BN/ HOT GAS SOLENOID HARV ASSIST M MOTOR DUMP VALVE R R/ BU TO COMPRESSOR SECTION SEE NAMEPLATE FOR PROPER VOLTAGE REQUIREMENTS AND MAXIMUM FUSE SIZE INLET POER CORD ATER LEVEL SENSOR ICE THICKNESS PROBE R BK BK J0 J9 BN/ BK 8 HGV RELAY 9 V V BN Y 8 COMPRESSOR RELAY 9 Y L BK TERMINAL BLOCK N V GN/Y J O LOAD SUMP TEMP. SENSOR DISCHARGE TEMP. SENSOR ELECTRONIC CONTROL J6 J BK LINE TRANSFORMER GN/Y EARTH GROUND J J8 THIS UNIT MUST BE GROUNDED. CURTAIN SITCH CURTAIN SITCH CAUTION: DASHED LINES INDICATE FIELD IRING HICH MUST BE INSTALLED IN ACCORDANCE ITH THE NATIONAL ELECTR ICAL CODE AND ALL STATE AND LOCAL CODES. MORE THAN ONE DISCONNECT MEANS MAY BE REQUIRED TO DISCONNECT ALL POER TO THIS UNIT. May 0 Page 6
EH0 D or EH0 D Schematic Diagram May 0 Page
EH0 D or EH0 D iring DIagram May 0 Page 8
ECC00 and ECC0 Single Phase iring Diagram May 0 Page 9
ECC00 and ECC0 Single Phase Schematic Diagram May 0 Page 0
ECC00, ECC0 and ECC800 Three Phase iring Diagram May 0 Page
ECC00, ECC0 and ECC800 Three Phase Schematic Diagram May 0 Page