Certified Energy Efficiency.

Similar documents
Energy efficiency with certified products

Quality and sustainability. Inspection and testing, approvals, certificates

Performance Rating of Airto-Air Heat Exchangers for Energy Recovery Ventilation Equipment

Air Handling Units RM-/RL-Line. AHU Casing Characteristics, Design Details For Outdoor Installation And Increased Hygiene Requirements

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

UNDERSTANDING GENERATOR SET RATING DEFINITIONS. Nick Paolo, Regional Sales Engineer MTU Onsite Energy

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

Gemeinschaft Thermisches Spritzen

THE MINISTER OF INDUSTRY AND TRADE, b. that for this purpose, it is necessary to issue a decree of the Minister of Industry and Trade.

Certification Scheme

Triple offset butterfly valve meets the stringent requirements of TA-Luft and ISO Advanced environmental protection the ZETRIX way!

Fan Powered Terminal Units FPV, FDV Series Variable Volume Parallel Flow

EUROPEAN UNION AGENCY FOR RAILWAYS Annex 1 006REC1025 V 1.0

Type: Office work chair Lab.no.: Depth: 650 mm Width: 710 mm Height: 1345 mm Weight: 18,8 kg. EN :2009 and EN :2009.

LEAKAGE CLASS ACHIEVED? Wöhler DP 700 LEAKAGE TEST ON VENTILATION SYSTEMS AND COMPONENTS. The Measure of Technology GRAPHIC COLOR DISPLAY GRAPHIC

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

SKN_N0106AnnexJ_R2. Annex J - Specific requirements for PVT collector Certification. 1. Introduction and definition

Su-Kam unveils ATC Technology for the first time in India

Novenco axial flow fans. ZerAx - Standard January 2010

elektronik Designing vehicle power nets A single simulation tool from initial requirements to series production

Natural Gas for Transportation Codes & Standards Issues

Central Station Air-Handling Units

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

UNIGLAS Tender Specifications

RULES PUBLICATION NO. 98/P

UN/SCETDG/46/INF.14 UN/SCEGHS/28/INF.6

Type: Office work chair Lab.no.: A. EN :2009 Office furniture - Office work chair - Part 2: Safety requirements.

Calibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 5

Bild : Bernhard Mühr German Aerospace Center Flight Operations

American National Standard for Lighting Equipment Voltage Surge Requirements

Building Energy Code (BEC) and Energy Audit Code (EAC) (2012 Edition) for Buildings Energy Efficiency Ordinance (Chapter 610)

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Size and Configurations

Resolving Responsibilities, clarifying criteria: Sustainability certification under the EU Renewable Energies Directive

The bereal Project - Scientific Highlights

Certificate: / 22 March 2013

QUESTION / CLARIFICATION

High Performance Axial Fans

Method Implementation Document (MID)

Industry 4.0 Is Unthinkable Without Calibration!

Information for the Certification of Weld Shops in Rail Vehicle Construction According to DIN EN

CertRom. BUCHAREST, S5 Calea 13 Septembrie 231A; Ph: , Fax: ;

Insights into WLTP and RDE

A new dimension ZPF 9H the central suction and filter unit

PowerFLEX Module Limited Warranty Program

Certification Scheme

IBExU Institut für Sicherheitstechnik GmbH

SUNNY BACKUP System. Solar Power Even in the Event of Grid Failure

REBATE APPLICATION. 1. Rebate Applicant Information. 2. Dealer Information OKLAHOMA NATURAL GAS COMPRESSED NATURAL GAS (CNG)

YARWAY NARVIK VEN-TEMP DESUPERHEATER MODEL 25

ISCC s Risk based Certification Approach for Waste and Residues

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

Biodiesel Fuels Made of Used Cooking Oil Version1.0. Certification Criteria

Length: 895 mm Width: 1355 mm Height: 705 mm

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

VIETNAM NATIONAL STANDARDS AND LABELING REQUIREMENTS

UK Weighing Federation Technical Articles

Policy for TSO Aircraft Seats

Certification Memorandum. Approved Model List Changes

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Lube & Seal for Power Transmission Engineering. Enhanced and prolonged sealing with Klüber Lubrication and Freudenberg Sealing Technologies.

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Lubricant Service Designations for Automotive Manual Transmissions, Manual Transaxles, and Axles

for TECHNICAL ADVICE OF THE EUROPEAN UNION AGENCY FOR RAILWAYS THE EUROPEAN COMMISSION regarding ERA/AD V/ running gear - design of structural

8-7 Heavy vehicle kingpin or socket coupling (for towing a semi-trailer)

WLTP for fleet. How the new test procedure affects the fleet business

German Aerospace Center Flight Operations

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

Samsung Modelling Guide for equest

Technical information No. 01. IT systems. The basis for reliable power supply

EMS ELONGATION MEASUREMENT SYSTEM. Strain measurement system for wind turbines optimizing the control & condition monitoring

MODULAR AIR HANDLING UNITS GAH SERIES

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

Q&A ON EMISSIONS TESTING

DLG Test Report Vredestein. Traxion Optimall. Efficiency advantages. Effizienzvorteile VF-Technologie. VF technology?

Reliability coefficients MTTF D for functional safety according to ISO MTTF D values for cartridge valves

Performance Rating of Single Package Vertical Air-Conditioners And Heat Pumps

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Other significant updates include:

*** DRAFT *** Lubricant Service Designations for Automotive Manual Transmissions, Manual Transaxles, and Axles

Examining the load peaks in high-speed railway transport

An Explosive Situation. Definitions

Prüffeld der Schaltwerke

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

DEPARTMENT OF TRADE AND INDUSTRY NO APRIL 2016

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Intelligent Balancing Solutions

THE NEW GENERATION OF WEDGE LOCKING WASHERS PRODUCT GUIDE - SOLID-LOCK WASHERS

COMMISSION REGULATION (EU) / of XXX

Joint Legislative Program Evaluation Oversight Committee March 14, 2012

PRODUCT CONFORMITY CERTIFICATE

ZE motor-protective relay Overload monitoring of EEx e motors

2018 Program Manual CoolSaver

LG HVAC SOLUTION. LG Electronics. Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Efficiency classes of single-speed three-phase, cage-induction motors

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Certification Directorate. General Aviation and RPAS Department. Report

DC TO AC POWER INVERTER PWRINV150W INSTRUCTION MANUAL

Transcription:

Certified Energy Efficiency. Air handling units always boast up-to-date energy efficiency labels: In accordance with the AHU-Guideline 01 of the German AHU-Manufacturers Association or according to the EUROVENT-Guideline.

Energy Efficiency: Up-to-Date with robatherm Upon request, robatherm offers both energy efficiency classifications in accordance with the AHU-Guideline 01 of the German Association of AHU-Manufacturers as well as commendations with the Energy Efficiency Label from EUROVENT. The energy efficiency classifications of air handling units (AHU) provide reliable guidance. As in the case of electrically operated household appliances and devices (refrigerators, washing machines, etc.), which for many years have undergone evaluations of their energy efficiency standards and have been subsequently awarded comprehensible labels. Specific Fan Power Value Unsuitable for the Evaluation of AHU-Devices The Specific Fan Power (SFP) value according to DIN EN 13779 only permits a rudimentary evaluation of a system s overall ventilation and air condition, as the AHU-system s efficiency is only taken into indirect consideration. This is due to the fact that the SFP-value is significantly influenced by the external pressure loss, which is neither influenceable by the equipment manufacturer nor dependent upon the quality of the device. Specific Fan Power SFP E 1, 2 according to DIN EN 13779 1 to be determined with clean filters and dry mounting parts. 2 Plus additional values for components according to DIN EN 13779 3 Minimum requirement according to the German EnEV 2014 (Energy Savings Regulation) Additional values for Components according to DIN EN 13779 Recommended SFP-Classes for AHU-Systems according to DIN EN 13779 Page 3 robatherm 02/2014

Energy Efficiency Classes according to the AHU-Guideline 01 The energy efficiency classes in accordance with the AHU-Manufacturers Association allow simple, traceable and verifiable evaluation of the factors that significantly influence energy efficiency. Energy efficiency labels render quick and reliable information to designers, plant engineers and operators as to whether an AHU-device is energetically optimized or not. All required performance categories of an efficiency class must be fulfilled for awarding the efficiency label of the AHU Manufacturers Association. The AHU guideline classifies performance categories according to the European standard DIN EN 13053. These criteria are mandatory. The procedure is monitored by the German technical inspection agency TÜV-Süd. Only certified member companies may award the AHU Manufacturers Association label. Important for the assignment of efficiency classes Page 4 robatherm 02/2014

Air Velocity Classes 4 according to DIN EN 13053 4 The velocities are related to the filter cross-section of the AHU-device. Heat Recovery Classes 5 according to DIN EN 13053 Reference values 5 Classes define the quality of the HR, independent of the HR-System by balanced mass flow rates (1:1). The sole application of the heat recovery coefficient is no longer permitted. 6 Values are based the calculation according to DIN EN 13053 as shown on the right side of the chart above. 7 With heat transfer rate (dry) η t [%] according to EN 308 (for mass flow 1:1) 8 With air flow rate: q v [m³/s]; operating power HRS: P el_aux [W] Electrical Power Input Classes according to DIN EN 13053 9 with static pressure loss Δp stat [Pa] and air flow rate q v [m³/s] Page 5 robatherm 02/2014

Energy Efficiency Classes according to EUROVENT According to the EUROVENT-Procedure, five energy efficiency classes (from A to E) are available. This detailed differentiation allows the rating differences to be easily recognized. As opposed to the AHU-Manufacturers Association s process, EUROVENT applies the compensation procedure. In this case, not all individual reference values of the desired energy efficiency class must be complied with. For example, a HRS lower heat recovery coefficient can be compensated by a better (lower) power input of the fan motor. The compensation of the influential variables, air-velocity and pressure loss of the HRS as well as the heat recovery coefficient of the HRS is based on the conversion into standard pressure loss allowances. The weighting of these allowances takes place based on the primary energy requirement. In this case, the primary energy factor of the electrical energy is calculated by a factor of 2 greater than the primary energy factor of thermal energy. The air velocity in clear cross-section, the dry heat recovery coefficient and the pressure loss of heat recovery as well as the power input of the fans further remain the decisive variables for energy efficiency. However, due to the calculation s complexity, it is neither comprehensible nor selfexplanatory for interested customers. EUROVENT-Reference Values 10 according to EUROVENT 6/12 10 The reference values present the basis for calculation of the compensation factors. Due to the possible compensation, the unit-specific values could exceed/fall below the reference values. 11 Valid for all unit-groups 12 Valid for units with outdoor air connections and design temperature t Winter 9 C 13 Valid for all unit-groups (evaluation of the electrical power input for the calculated reference power To be permitted to implement this procedure, the members are subject to a strict certification process. This also includes, besides the annual inspections of the design software, measurements on real units, whereas the real unit must fulfill the performance data that has been denoted. This inspection may only be carried out by accredited inspection institutions (e.g. TÜV). A direct comparison between energy efficiency classes, according to EUROVENT and according to the AHU-Manufacturers Association, is not possible. Page 6 robatherm 02/2014

robatherm accepts no responsibility or liability for the correctness and completeness of the contents in this document. To a certain extent, illustrations and descriptions partially include material that exceeds standard configurations. This document is subject to technical changes. Edition 02/2014. Copyright by robatherm.

robatherm Industriestrasse 26 89331 Burgau, Germany Tel. +49 8222 999-0 Fax +49 8222 999-222 info@robatherm.com www.robatherm.com