Product brochure. Gas-insulated Switchgear ELK-3 GIS for maximum performance, 550 kv

Similar documents
Product brochure. Gas-insulated Switchgear ELK-3 GIS for maximum performance, 420 kv

Product brochure. Gas-insulated switchgear ELK-4, 800 kv Pioneering technology for extra-high voltage applications

Product Brochure. Gas-insulated Switchgear ELK-14 The modular system for GIS, 245 kv

B kv Gas-insulated Substations

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

B kv T&D GAS INSULATED SWITCHGEAR

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

NXPLUS C Single busbar. Maintenance-free for lifetime

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Gas Insulated Switchgear ELK-0. for stations up to 170 kv, 4000 A, 63 ka

Gas-insulated switchgear up to 420 kv, 63 ka, 5000 A Type 8DQ1. siemens.com/energy. Answers for energy.

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

Raising the bar. UHV switchgear and components

Gas Insulated Switchgear

Gas Insulated Metal-clad Switchgear, HMGS!

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

PASS M0. Innovative solutions for distribution substations up to 170 kv

Gas-Insulated Switchgear up to 245 kv, 50 ka, 3150 A Type 8DN9. Power Transmission and Distribution

HIS Highly Integrated Switchgear up to 550 kv, 63 ka, 5000 A Type 8DQ1

Product Specification

8DJ. Maintenance-free for lifetime

ZX2.2 Gas-insulated medium voltage switchgear

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

ZX2 Gas-insulated medium voltage switchgear

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Compact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS)

Metal Clad Air Insulated Switchgear

EMPAC Metal enclosed capacitor bank for wind applications

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Air-insulated switchgear UniGear type ZS1

Outdoor vacuum breaker for railway applications - FSK II

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Bushings for High Voltage AC Applications

Chapter 6 Generator-Voltage System

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

Solid Dielectric, Three Phase Reclosers CATALOG VS11

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

CPG.0 Single busbar gas-insulated cubicles

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Substation Concepts for the Future

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Transformer bushings, type GOH. Technical guide

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

Benefits, typical uses

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

Stefano Cervidi - ABB S.p.A. PPHV Santiago de Chile J.T. ABB Chile de Abril 2015 PASS - Plug and Switch System Subestaciones con tecnologìa

PASS M00. Multifunctional modules for high voltage substations kv; A;... 31,5 ka

AIR CORE REACTORS. Phoenix Electric Corporation

SWITCHGEAR DIVISION PRODUCT PROFILES

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

ZX-Family Gas-insulated medium voltage switchgear

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

GROUP D. Switch & Protective device.

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

Gas-Insulated Switchgear up to 145 kv, 40 ka, 3150 A Type 8DN8. Power Transmission and Distribution

High Voltage Surge Arresters Buyer s Guide Section Line Surge Arrester PEXLINK

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

HIS Highly Integrated Switchgear up to 145 kv

NEW CONCEPT FOR MEDIUM VOLTAGE GAS INSULATED SWITCHGEAR (GIS) by LJ Fleischer, Siemens Electricity + Control May 1999

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Pankaj Khali, ABB India Limited Representing :ABB Switzerland limited, September 2016 Generator Circuit-Breakers. Technical Seminar: PLN

Breaking new ground. A circuit breaker with the capacity to switch 15 large power plants

Publication No.: PSG

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

3AP1 DTC for 145 and 245 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv

UniGear. Technical Guide

LV Capacitor CLMD Reliability for Power Factor Correction

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Power Voltage Transformers for Air Insulated Substations

Transcription:

Product brochure Gas-insulated Switchgear ELK-3 GIS for maximum performance, 550 kv

Introduction ABB has been pioneering the development and manufacturing of SF 6 Gas Insulated Switchgear (GIS) since the sixties. The first 170 kv GIS was installed in 1969 at Sempersteig (Zurich/Switzerland). The next important milestone was the delivery of the first 500 kv GIS at Claireville (Ontario/Canada). Over 10 000 bays rated from 72,5 to 800 kv have been supplied world-wide to the full satisfaction of their users. Milestones First 170 kv GIS Sempersteig (CH) Early research 1956 1966 First 500 kv GIS Claireville (CA) First 800 kv GIS Alpha (ZA) Largest 500 kv GIS Itaipu (BR) First 500 kv GIS Jiang Men (CN) > 300 kv 170-300 kv 1976 1986 1996 550 kv GIS 3 Gorges Project (CN) 2006 3000 2000 1000 delivered bays A large number of key substations in all parts of the world depend on the outstanding performance of ABB s safe and reliable GIS products, based on extensive knowhow, high manufacturing standards and long field experience. World-wide success 550 kv GIS Claireville 6 bays 550 kv GIS Pin Hook 3 bays 420 kv GIS St. Johns Wood 18 bays 420 kv GIS Eemshaven 8 bays 420 kv GIS Lechhausen 5 bays 420 kv GIS Asphard 5 bays 550 kv GIS 3 Gorges Project 73 bays 500 kv GIS Jiang Men 12 bays 550 kv GIS Jingzhou 2 x 15 bays 550 kv GIS Itaipu 54 bays 2 380 kv GIS Shedgum 15 bays 500 kv GIS Hub River 12 bays 500 kv GIS Yantan 11 bays 550 kv GIS South Morang 12 bays

Active parts under high-voltage Enclosure SF 6 -gas Insulation material Mechanical parts, structures Low-voltage parts GIS-Type ELK-3 Encapsulation single-phase Rated voltage kv 420 550 Rated power-frequency withstand voltage kv 650 740 Rated lightning impulse withstand voltage kv 1425 1550 Rated current A 4000 4000 Rated breaking current ka 63 63 3

Flexibility by modular design The background Based on the unique experience on development of GIS products and realisation of GIS substation projects, ABB developed the most flexible modular design for GIS equipment. Application The proven modular design provides a high versatility to meet the most challenging present and future user requirements. The following examples exhibit the variety of applications that have been put into practice by ABB. Front view of a double busbar GIS substation with four line bays, a bus coupler bay and a transfer busbar. Switching stations with rigorous safety requirements. Indoor substations to occupy a minimum of space in densely populated urban areas. Protected installations exposed to unusually dirty, polluted or corrosive environments. Underground substations for pumped storage and other hydro-electric power stations. Generating plants where the switchgear can be very close to the power transformers to give an ideal overall layout. The extension of conventional outdoor installations where space is constraint. Replacing existing substations and upgrading the voltage level without taking up extra space. Main design features Lightweight enclosures of aluminium with good conductivity, no eddy-current losses and a high resistance to corrosion. Single-phase encapsulated design, assuring minimal dielectric and dynamic stresses. Legend 1 Circuit-breaker 4 Sectional view of type ELK-3 feeder bay with double busbars and outdoor bushing 2 Operating mechanism (circuit-breaker) 3 Current transformer 4 Disconnector 8 5 Maintenance earting switch 6 Fast-acting earthing switch 7 Voltage transformer 8 Bushing 7 6 5 4 4 3 2 1

KUPPELFELD GOESGEN EICHHARD SUED SS1 SS2 All switchgear components, such as the circuit-breakers, disconnectors, earthing switches, instrument transformers and connecting elements are functionally separate modules of a standardised modular system. The view on page 4 shows the sectional elevation of a typical switchgear bay of the ELK-3 size. All live parts are protected aluminium enlosure. Pressurised SF 6 -gas provides the insulation against the earthed enclosure. WIESENTAL SUED Top view of a double busbar GIS substation with four line bays, a bus coupler bay and a transfer busbar. Proven metal-to-metal flange connections, ensuring high gas tightness and return-current conductivity, avoiding crossbonding. Increased personnel safety and electromagnetic compatibility. Horizontal circuit-breaker design, saving building elevation and cost, ensuring convenient personnel access. Minimal outage concept with segregated, individually monitored gas compartments. WEHRA HS Digital control, on-line condition monitoring and synchronised switching options. Short erection times and high reliability, by providing large transport units assembled and tested in the factory. High-grade insulators of moulded resin support the active parts inside the enclosure and are used as the barriers between adjoining gas-filled compartments. The individual compartments assure maximum possible availability of the equipment during maintenance work and extensions. The individual components are connected by silver-plated plug contacts for the current conductors and bolted flange connections for the enclosures. The switchgear is mounted on a simple hot dip galvanized steel structure attached to the floor. Modular design with standardised components for complying with user s requirements. 5

Circuit-breaker Circuit-breaker Reliable making and breaking capacity for heavy load and short-circuit currents Easy access to active parts for inspection and overhaul Low noise level Maintenance-free design Separate contact system for continuous current and current interruption High dielectric withstand in open and closed position Single-phase auto-reclosing Compact hydraulic spring operating mechanism Continuous self-supervision of hydraulic system No external hydraulic piping Type tested according latest IEC & ANSI standards The simple, robust design and a horizontal layout with low center of gravity are the most famous features of the circuit-breakers. Extensive operating experiences up to voltage range 800 kv and 80 ka as well as continuous research and development activities have lead to a breaker design which fulfils newest standards in IEC and ANSI. Breaker design Each circuit-breaker comprises three single-phase metal enclosed breaker poles. Each pole consists of the operating mechanism, the interrupter column with 2 interrupting chambers in series and the enclosure with the basic support structure. To guarantee simultanious interruption, the chambers are mechanically connected in series. One grading capcitor for each chamber guarantees an equalised voltage distribution across the interrupting chambers. In case of an overhaul, the interrupter column can easily be removed from the enclosure. The circuit-breaker is of the singlepressure type and works on the well proven puffer principle. During an interruption, a compression piston in each chamber generates the SF 6 -gas pressure required to extinguish the arc between the contacts. Breaking sequence of the circuit-breaker ELK-3 Substation 6

Operating mechanism Each pole of the circuit-breaker is equipped with the hydraulic spring operating mechanism. It combines the advantages of the hydraulic operating mechanism with those of the spring energy storage type. It s compact, modular design, consisting of the housing with position indicator power-pack for energy storage without any kind of external hydraulic pipe monitoring module for control It guarantees easy access to all components inside the drive for overhaul and repair. Sealing of the pressure operated hydraulic circuit against the atmosphere is achieved entirely by highly reliable static seals. Working principle A hydraulic pump moves oil from the low pressure reservoir to the high pressure side of the energy storage piston, connected to the disc springs. The output piston, which is connected to the operating rod of the circuit-breaker column, is controlled by a changeover valve. For opening, it switches hydraulically to the open position after the trip coil is actuated for opening the breaker and connects the bottom side of the output piston with the low pressure reservoir. The circuit-breaker moves than to open position where it will be retained due to the hydraulic pressure. For closing the circuit-breaker, the changeover valve connects the bottom side of the output piston to the high-pressure reservoir after actuation of the closing coil. Now, both sides of the output piston are connected to the high pressure and the circuit-breaker is moving to it s closed position due to the differential pressure principle. Hydraulic spring operating mechanism Schematic diagramme of the operating principle 0 1 7 M M High pressure Low pressure

Disconnector and earthing switch In-line disconnectors Disconnector Safe SF 6 -gas insulation across the open gap Slow moving tubular contact Motor-operated mechanism, common for all 3-phases, padlockable Designed for full load and shortcircuit current in closed position Reliable switching of small capacitive and bus transfer currents Manual operation is possible The no-load type disconnector according to IEC 60129 is available either as an in-line or an angular disconnector. The angular disconnector integrated in the busbars, greatly simplifies the layout of the installation. Supporting insulators carry the active parts of the disconnector inside the modular enclosure. It is also possible to accommodate a maintenance earthing switch in the same enclosure. The active part consists of the fixed part with contact fingers and follow-up contact and the contact support carrying the tubular moving contact. Inspection of the main contact status is possible by means of an endoscope through the viewport in the enclosure. The moving contact is operated from a motor gear drive through a rotary seal by an insulated shaft. The position indicator and the auxiliary contacts are mechanically coupled with the mechanism. The operating mechanism is mounted outside the gas compartment on one phase. The two other phases are operated by intermediate gear. The same mechanism is also employed for the maintenance earthing switch. 8 Various applications: In-line disconnectors Angular disconnectors

0 0 0 0 Manual operation is possible. In this case electrical control connections are automatically disconnected. The mechanism is padlockable in both, open or close position. Earthing switch Safe earthing of sections of the main circuit Designed for full short-circuit current in closed position Insulated version available (optional) Motor-operated mechanism, slow closing or high-speed spring-loaded Full short-circuit making and induced currents switching capability Earthing switches are mounted directly on the enclosure (see figure below). Slow-motion maintenance earthing switches are used for earthing isolated sections of switchgear to protect personnel during maintenance and overhauls or erection. The operating mechanism is the same as used for the disconnector switches. It is mounted on one phase. The two other phases are operated by intermediate gear. The fast-acting earthing switch is mainly used to discharge static charges on overhead lines, HV cables or long buses. It is designed to close on and carry full shortcircuit currents and to safely break capacitive and inductive induced currents from long energised parallel lines. Each phase is provided with its own operating mechanism. For the closing operation a spring in the drive is loaded by the motor. At the end of the charging operation the spring is automatically released and the switch closed. The opening process is slow, similar to that of the maintenance earthing switch. In certain cases, an interposed insulation is fitted between the earthing switch and the enclosure. This provides access to the active parts for measuring purposes through the closed contacts, without opening the enclosure. During normal operation the insulation is by-passed. All the earthing switches have a mechanically coupled position indicator. The gap between contacts can also be verified through a viewport by means of an endoscope. To check whether a point to be earthed really is dead, the earthing switch can be equipped with a capacitive tap for connecting a voltage test unit. This additional safety device reduces the risk of closing onto a live conductor. Application examples (from left to right) Maintenance earthing switch Fast-acting earthing switch 9

Instrument transformer and surge arrester Single-pole inductive voltage transformer Voltage transformer Inductive type, with SF 6 -gas insulated high-voltage winding Rectangular type core of low loss magnetic sheets High cable or line discharging capability Efficient damping of ferro-resonance and fast transients The single-pole inductive voltage transformers are connected to the switchgear with the standardised connecting flange with a barrier insulator. The primary winding is insulated with SF 6 -gas and connected to the high-voltage terminal. The primary winding is wound on top of the core and the secondary windings. The secondary windings are connected to the terminals in the external terminal box through a gas-tight multiple bushing. The transformers may be equipped with two metering windings and one tertiary winding for earth-fault protection. Current transformer Ring cores surrounding the enclosure, impregnated with moulded resin Cores outside of the gas, protected by metallic cover The necessary number of cores is accommodated around tubular enclosures of suitable length. The main conductor within the enclosure forms the primary winding. Ring cores, are protected against external influences by a metal cover which is designed to carry the return current. An insulation gap prevents the return current from flowing inside the cores through the enclosure. A terminal box mounted on the cover contains the secondary terminals. 10 Inductive-type voltage transformer housed in an individual gas compartment Current transforner with ring cores outside of the enclosure

Surge arrester Metal-oxide resistors housed by SF 6 -gas insulated enclosure Without spark gaps Low protection level High energy input capacity Stable characteris tics, ageingproof Gas-insulated substations and connected HV cables, power transformers, etc. often require over-voltage protection by surge arresters. Gas-insulated arresters are a reliable and space-saving alternative to the conventional type, avoiding the need of aerial links. The active parts, mainly non-linear metal-oxide resistors, series connected and assembled to stacks, are housed in a pressurised SF 6 -gas enclosure, which is connected to the GIS by a standard ELK-3 flange connection with barrier insulator. The resistors are manufactured as disks with a conductive, metallic coating on the flat contact surfaces and a gas-tight coating on the cylindrical surfaces. Arresters with metal-oxide resistors have a high energy absorption capability. A grading electrode surrounds the resistors on top and ensures an even voltage distribution along the resistors. An advantage of this design is that the SF 6 -gas flows around the resistors, ensuring efficient cooling when required, i.e. after repeated heavy discharges. Surge arrester Length section of the principal arrangement and cross-section of the MO resistor stack 11

Connecting elements, terminations Versatile connecting elements A modular range of straight busbars, tees, elbows is available, enabling the different major components to be arranged in a space-saving way, coping with any customer requirements. The busbar enclosure is dimensioned for the full return current. The metallic connection of the flanges is also assured at points where supporting or barrier insulators are interposed. Tubular conductors are supported at each end by an insulator. The conductors are plugged to silver-plated spiral spring contacts on the supporting insulator. These sliding contacts permit the tubular conductors to expand axially on a temperature rise, without imposing any mechanical stresses on the supporting insulators where required. Longitudinal expansion is taken up by metal bellows or parallel compensators. Lateral dismantling unit Where required, lateral dismantling units are inserted. They enable sections of the switchgear to be removed and re-inserted, without interfering with the adjacent parts. This is achieved by sliding sections in the enclosure and in the tubular conductor. 12 Connecting elements Lateral dismantling unit

SF 6 /air termination SF 6 -air bushings used for connection to open terminal equipment and overhead lines are available with composite or porcelain insulators. The internal insulation consists of pressurised SF 6 -gas or resin impregnated paper winding (RIP). Nowadays composite insulators are used more and more for highvoltage applications because of there outstanding mechanical and dielectric properties; the latter due to the hydrophobian capability of the silicon rubber sheds. Bushings with composite insulators are absolutly explosions proof. Cable termination An isolating link between the switchgear and the cable termination enables the GIS and the cable to be tested separately. Transformer connection The transformer connection consists of the oil/sf 6 -bushing, the enclosure, the main circuit end terminal and the removable connection. The pressure-tight bushing separates the gas-filled compartment from the insulating oil of the transformer. The lateral dismantling unit takes up axial assembly tolerances and enables the transformer to be easily connected, or disconnected from the switchgear. For the high -voltage tests on the GIS, the transformer is isolated from the switchgear by dismantling the removable conductor connection. High-voltage cables of various types are connected to the SF 6 switchgear via cable connection assembly. It consists of the cable sealing with connecting flange, the main circuit end terminal and the surrounding enclosure. SF 6 -air bushings with porcelain (1) or composite insulator (2) Cable termination (3) and transformer termination (4) 1 2 3 4 13

Local Control The local control cubicle is based on the Bay Control Solution concept BCS as a comprehensive scalable solution for control cubicles. The BCS is suitable for all types of switchgear used in transmission and subtransmission systems and every possible busbar configuration. The BCS includes all required functions for control and supervision of a complete GIS as well as the marshalling of all connections to and from the GIS bays. Safe station operation is ensured through following base functions. Functions Feeder and station interlocking, depending on the position of all high-voltage apparatusses with their blocking functionality Blocking of commands when crank handle of disconnectors or earthing switches is introduced. Extensive circuit-breaker supervision through Anti-pumping, pump and hydraulic system supervision, operation counter for circuit-breaker and pumps. Gas density and position supervision of circuit-breaker. Supervision of pole discrepancy for circuit-breaker The Bay Control Mimic BCM is the main component of the control cubicle. Features Representation of the single-line diagramme/gas schematic diagramme including position indication of all primary apparatusses such as circuit-breaker, disconnectors and earthing switches with reliable LED s Up to 8 high-voltage switching devices can be monitored and controlled with an easy-to-use two hand push-button system based on the select before operate principle Optional light guided operation to support the operator Digital display of measuring values as current, voltage, active and reactive power Integrated local/remote key switch Alarm unit for 16 feeder alarms e.g. gas alarm, DC and AC supervision 14

The local control cubicle is fitted with prewired interface terminal blocks for the connection to feeder and station protection. This interface includes all needed measuring values of the feeder as well as protection trip 1, trip 2 and signals from the auto-reclose system. Additional prewired terminal groups are provided for the connection to remote control systems and remote alarm systems. On customer s request additional functions (optional) can be provided. Standardised plug connections instead of terminal connections are available. 15

Space saving arrangements The world-wide experience shows that the proven ELK-3 architecture with its modular concept and versatility opens the way for efficient arrangements for virtually any application and individual user requirements. Stringent space requirements can be met without concessions to service access. Horizontal circuit-breaker design provides a substantial reduction of the height of the building and civil work cost. It offers also convenient possibilities for simple and efficient future extension of the substation with minimal outage. As example the two most common applications are shown, double busbar and one-and-a-half breaker arrangement. Single busbar, ring and various other arrangement are as well possible. Typical ELK-3 double busbar arrangement with two line bays (one with aerial, one with cable connection), a transformer bay and bus coupler bay. 16 Double busbar bay: overhead line, transformer, cable feeder and bus coupler bay

Four diameters of a typical ELK-3 one-and-a-half breaker arrangement Bay section one-and-a-half breaker arrangement 17

Reliable gas compartments Individual, fully equipped gas compartments Safe gas sealing system Gas density monitor A prerequisite for safe and reliable operation is the segregation of the sections and phases of the equipment into individual and independent gas compartment. This is also required to keep parts of the system in operation while other parts are out of service. The segregation is achieved by barrier insulators. To avoid any impact from each other, all gas compartments are fitted with their individual non-return filling valve and density monitor. Any pipe connections to common sampling points are therefore strictly avoided. Each compartment is also fitted with its own moisture absorber and pressure relief. Reliability of SF 6 gas-insulated switchgear depends to a large extent on the low rate of gas leakage. Thus special attention is given to the sealing system. The proven static sealing system at the flange joints is effected by single sealing rings ( O-rings ). High-quality finish limits the gas losses to much less than 0.5 % per annum. The dielectric strength of the GIS depends on the gas density, which is therefore directly monitored. The proven density monitor is directly mounted on the enclosure. The gas pressure acts on metal bellows, with a reference volume for compensation of the temperature. In case of gas leakage a micro-switch is actuated. Thresholds for refilling (first stage) or lock-out alarm (second stage) can be mechanically set. The response characteristic is shown in the Mollier diagramme. Density monitors can be easily removed for testing with a separate calibration device. 18 Single-line and gas schematic diagramme Flange connections Gas density monitor M M M M

Main technical data ELK-3 Rated voltage kv 420 550 Rated power-frequency withstand voltage kv 650 740 Rated power-frequency withstand voltage across open contacts kv 800 910 Rated lightning impulse withstand voltage kv 1425 1550 Rated lightning impulse withstand voltage across open contacts kv 1425+345 1550+450 Rated switching impulse withstand voltage kv 1050 1250 Rated switching impulse withstand voltage across open contacts kv 1050+345 1250+450 Rated frequency Hz 50/60 50/60 Rated continuous current: Busbar current A 6300 6300 Feeder current A 4000 4000 Rated short-time withstand current ka 63 63 Rated peak withstand current ka 170 170 Components: Rated filling pressure at 20 C, abs. kpa 420 460 Minimum functional pressure at 20 C, abs. kpa 350 390 Circuit-breaker: Rated filling pressure at 20 C, abs. kpa 680 680 Minimum functional pressure at 20 C, abs. kpa 600 600 SF 6 -gas leakage rate per year and gas compartment % <0.5 <0.5 Mollier diagramme 420 kv Mollier diagramme 550 kv 19 P abs (kpa) (g/dm 3 ) P abs (kpa) (g/dm 3 ) 1000 60 56 52 48 1000 60 56 52 48 900 46 a) 44 900 46 a) 44 800 42 b) 40 c) 38 800 42 b) 40 c) 38 36 36 700 34 700 34 32 32 600 500 30 28 a) 26 24 b) 22 c) 600 500 30 a) 28 26 b) c) 24 22 400 20 18 400 20 18 16 16 300 14 300 14 200 t C 200 t C -50-40 -20 0 20 40 60 80 100-50 -40-20 0 20 40 60 80 100 Legend: Circuit-breaker GIS-Components Legend: Circuit-breaker GIS-Components a) Filling pressuren b) Alarm level 1 c) Min. pressure, Alarm level 2 a) Filling pressuren b) Alarm level 1 c) Min. pressure, Alarm level 2

Contact us ABB Switzerland Ltd High Voltage Products Brown Boveri Strasse 5 CH-8050 Zurich / Switzerland Phone: +41 58 588 31 86 Fax: +41 58 588 17 22 www.abb.com Copyright ABB. 1HC1HC0000742 E01 / AF10