High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

Similar documents
Low voltage bushings for pad-mounted distribution transformers Technical information guide

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

Eaton s Cooper Power Systems

Product Description: Objective and Certification: Test Samples and Test Cable:

A 1.2 kv class externally removable secondary bushing

ABB Power T&D Company Inc. General Information: DT-100 DT-150 DV-100 DV-150. De-energized Switches TPL , July 1999, Page 1 of 4

25kV 200A Loadbreak Bushing Insert and Elbow Design Test Report. Report Number:

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

25 kv Apparatus Bushings

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

dfdf 34.5 kv and 69 kv, Type O Plus C II Condenser Bushings Technical Guide

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

15kV 200A Loadbreak Fuse Elbow Design Test Report. Report Number:

15 kv and 25 kv Thru-Bushings

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

GROUP C. Apparatus Bushing.

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

INSTALLATION PRODUCTION TESTS

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Zinc Oxide Surge Arrester EXLIM R

600 A 35 kv class BT-TAP deadbreak connector

CERTIFIED TEST REPORT. Cooper Power Systems. 25 kv Class 200 Amp 15.2/26.3 kv SEPARABLE CONNECTOR SYSTEM

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Dry Well Cannister Type CLT, OIL Immersed PTAP-AFH926. Technical Guide Load-break, Dead-break

100 A externally operated one-, twoand three-phase tap-changer switch

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Transformer bushings, type GOH. Technical guide

600 A 15 kv class T-OP II deadbreak connector

IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

600 A 15 and 25 kv class deadbreak accessories, tools, and replacement parts

200 A and 600 A, 15, 25, and 35 kv junction bars for separable connectors

Loadbreak Apparatus Connectors

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

High-voltage primary bushings installation instructions

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

TABLE OF CONTENTS Page

600 A 15 kv class Cleer loadbreak connector system

600 A 28 kv class Cleer loadbreak connector system

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

Zinc-Oxide Surge Arrester TEXLIM Q-C

600 A 25 kv class BT-TAP deadbreak connector

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Kuhlman Electric Corporation Volt Instrument Transformers

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st New RIS transformer bushings The paper-free solution

100 / 110 DRYWELL FUSE SPECIFICATION

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

Fluid characteristics impact performance capabilities in transformer application

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

Loadbreak Apparatus Connectors. 200 A 15 kv Class Loadbreak Elbow Connector with Optional Integral Jacket Seal GENERAL


Type IMC Indoor current transformer

200 A 25 and 28 kv class POSI-BREAK loadbreak elbow connector with optional integral jacket seal-canadian Edition

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Technical Specification For Outdoor Substation Harmonic Filter Banks

3M Cold Shrink QS-III Inline Splice Kits 15 kv 5513A, 5514A, 5515A and 5516A

3 Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8 Series

Portable High-Voltage Cable Couplers 415, 515

IEC Separable Connectors 17.5 kv/24 kv, 630A

QS-III. 5513A, 5514A, 5515A and 5516A 15 kv Cold Shrink Inline Splice Kits. Data Sheet CAUTION. 1. Product Description. 2. Applications.

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

ABB Transformadores para aplicaciones solares y eolicas

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

CERTIFIED TEST REPORT

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

FEBRUARY 14, 2017 Elastimold Solid dielectric switchgear customer presentation

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

Contents. Design Test Results for Specimen Design Test Results for Specimen Voltage Impulse Oscillograms...9

Kuhlman Electric Corporation Volt Instrument Transformers

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

Transcription:

1ZUA2761-500 rev. 5, 6 April 2010 High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

1ZUA2761-500 rev. 5, 6 April 2010 2 / 9 Table of contents 1 Description... 3 2 Ratings... 3 3 Features and Advantages... 3 3.1 Interchangeability... 3 3.2 Optional Removable Stud Design... 3 3.3 Proven Nylon Body... 3 3.4 Improved Appearance... 3 3.5 Compression Limited Gasket Designs... 4 3.6 Identification... 4 4 Certification... 4 4.1 Design Tests... 4 4.1.1 Dielectric Tests... 4 4.1.2 Mechanical Strength Tests... 5 4.1.3 Environmental Test... 5 5 Accessories... 6 5.1 Tank Wall Gasket... 6 5.2 Dust Cap... 6 5.3 Mounting Flange... 6 5.4 Replacement Studs... 6 6 Installation to the Transformer... 6 7 Outline Drawings and Installation Drawings... 6 7.1 Outline Drawing 1AUA2761-501, HV bushing well, integral & removable stud... 6 7.2 Installation Instructions: 1ZUA2761-502... 6

1ZUA2761-500 rev. 5, 6 April 2010 3 / 9 1 Description The ABB High Voltage Bushing Well is designed for use in oil filled pad or surface mounted transformers. The bushing well terminates the transformer s primary winding leads at the tank wall. On the air-side of the transformer, the bushing well mates with all bushing inserts which meet the applicable sections of ANSI/IEEE Standard 386. The bushing well is externally clamped to the sidewall of the transformer tank. The bushing well will operate properly in transformers which are filled with standard transformer oil or high temperature hydrocarbon fluids or natural or synthetic ester fluids. 2 Ratings Conductor Type Voltage Class BIL Rating Current Rating Style Number Integral 25 kv 150 kv 200 A 1ZUA276301-AKC Removable 25 kv 150 kv 200 A 1ZUA276301-AKD 3 Features and Advantages 3.1 Interchangeability The ABB bushing well is interchangeable with the majority of bushing wells presently supplied to the distribution transformer market in North America. It is designed to fit into a 2.53 in. (64.3 mm) mounting hole and it will mate with all bushing inserts which conform to the appropriate sections of ANSI/IEEE Standard 386. 3.2 Optional Removable Stud Design The ABB HV bushing well is available in a removable stud version. Use of the removable stud version of the bushing well allows simple field replacement of the bushing stud in cases where the stud becomes damaged. The stud can be removed with a standard 5/8 inch socket wrench. 3.3 Proven Nylon Body These ABB bushings are molded from a glass-reinforced, high temperature nylon resin (Dupont Zytel HTN). The Zytel HTN resin is a highly reliable thermoplastic that fulfills the required application needs for strength, temperature stability and low moisture absorption. The resin system retains its mechanical and electrical properties in the high temperature environment associated with the intended application in pad mounted distribution transformers. 3.4 Improved Appearance The combination of the Zytel HTN resin system and the molding process significantly improves the appearance of the bushing well.

1ZUA2761-500 rev. 5, 6 April 2010 4 / 9 3.5 Compression Limited Gasket Designs The bushing has a molded-in gasket seat to ensure proper gasket location and compression during mounting. The gasket surfaces provide controlled compression and containment of the highly resilient Buna-N gasket. 3.6 Identification Identification information is molded into the face of each bushing well. The following information is provided: ABB logo, BIL rating, Date code and mold cavity number. See the outline drawings for further details 4 Certification To certify the product ratings, production samples of the bushings were tested. The tests were conducted in accordance with ANSI/IEEE Standards where applicable. 4.1 Design Tests The design tests were divided into (3) three parts: Dielectric Tests (Impulse test and 60 Hz Withstand test) Mechanical Strength Tests (Leak test and Stud Torque Strength test) Environmental Tests (Thermal Cycle test, Oil Compatibility test) 4.1.1 Dielectric Tests Bushing wells are tested to the 25 kv Class requirements as defined in IEEE Standard 386. 4.1.1.1 Impulse Test The purpose of this test is to verify the impulse withstand of the bushing. Sample bushings were subjected to 3 positive and 3 negative full wave impulses. The voltage impulse used was the standard 1.2 x 50 μs wave having the crest value of the specified voltage. The withstand voltage level of the bushings was well above the BIL rating of 150 kv. 4.1.1.2 Low Frequency / 60 Hz Withstand Test The purpose of the low frequency withstand test is to verify the integrity of the insulation structure of the bushing at operating frequency. Bushing samples were tested at 50 kv, rms for one minute and then allowed to rest for one minute. They were then retested for another minute. All samples passed this test. The required pass level is 50 kv, rms.

1ZUA2761-500 rev. 5, 6 April 2010 5 / 9 4.1.1.3 Partial Discharge Test The purpose of the partial discharge test is to verify that partial discharge activity is not detectable at the test voltage of 26 kv, rms. Samples are energized at 60 Hz; the test voltage is raised until partial discharge is detected. The test voltage is then reduced until partial discharge is no longer detected this must occur at 26 kv, rms or higher. 4.1.2 Mechanical Strength Tests 4.1.2.1 Leak Test The purpose of the leak test is to ensure that, over the life of the bushing, no leak will develop between the copper stud and the nylon resin body. The bushings were tested using a Helium leak detector. The bushings were attached to a leak test fixture which mates the bushing to the Helium leak detector. A vacuum is created around the internal surfaces of the bushing such that any leak will be detected if Helium passes into the detector through the bushing. All bushings passed with no indication of leaks. The sensitivity of the Helium leak detector is 1 x 10-5 atm cc/sec. 4.1.2.2 Stud Torque Strength Test The purpose of this test is to verify that no damage will result when bushing inserts are threaded onto the bushing well stud. The bushing well is mated to an appropriate bushing insert. The insert is tightened to 17 foot-pounds. The inserts are removed and the bushing is inspected for damage and then leak tested. 4.1.3 Environmental Test 4.1.3.1 Thermal Cycle Test The purpose of the thermal cycle test is to verify the integrity of materials used in the bushing over the expected service life of the bushing. Bushings were tested according to IEEE Standard for Separable Insulated Connector Systems for Power Distribution Systems above 600 V, IEEE Std 386-2006, Section 7.20, Thermal cycle withstand test. All bushings passed this test. 4.1.3.2 Oil Compatibility Test The purpose of this test is to verify that the bushing when submerged in transformer oil has no damaging effect on the properties of the oil. The bushing passed the standard oil compatibility test.

1ZUA2761-500 rev. 5, 6 April 2010 6 / 9 5 Accessories The following accessories are available for purchase from ABB. They may be ordered at the time the order is placed for the bushing well or at any other time in accordance with ABB minimum order rules. 5.1 Tank Wall Gasket One gasket style fits both the fixed stud and removable stud bushing well. The gasket style number is 3A23916H01. 5.2 Dust Cap The flexible plastic dust cap fits over the well portion of the bushing well. It is used to prevent foreign material from contaminating the internal surfaces of the bushing well. The dust cap style number is 9820A26H01. 5.3 Mounting Flange The mounting flange for the bushing well is fabricated from high tensile strength zinc plated steel. It has securing holes for attaching a bail clamp. Note that this mounting flange is only compatible with the bail clips used with load break type bushing inserts. The style number of this mounting flange is 9820A33H01. 5.4 Replacement Studs Spare replacement studs may be purchased from ABB. The spare replacement style number is 1ZUA261107-AAF. 6 Installation to the Transformer The bushing well is mounted on the air side surface of the transformer tank. Please refer to drawing 1ZUA2761-502 for mounting details. The hole through the tank wall should be 2.53 inches in diameter after painting. The tank must remain flat around the mounting hole for a diameter of 3.81 inches. This is necessary in order to provide a suitably flat surface for the mounting gasket to seal against. 7 Outline Drawings and Installation Drawings These drawings are contained on the next two pages: 7.1 Outline Drawing 1AUA2761-501, HV bushing well, integral & removable stud 7.2 Installation Instructions: 1ZUA2761-502

1ZUA2761-500 rev. 5, 6 April 2010 7 / 9

1ZUA2761-500 rev. 5, 6 April 2010 8 / 9

1ZUA2761-500 rev. 5, 6 April 2010 9 / 9 Copyright 2007 ABB, All rights reserved Document Title High Voltage Bushing Wells for Pad Mounted Distribution Transformers Document No. Date & Rev. Ind. No. of Pages Page 1ZUA2761-500 4, 16 March 2009 9 9