I n s t a l l a t i o n M a n u a l. f o r T E D

Similar documents
N O T I C E - I M P O R T A N T

The Energy Detective

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

Warning. 1. Have the installation done by a qualified professional, according to local electrical codes. 1. It may not cause harmful interference,

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

TED 5000 USER MANUAL

Owner's/Installation Manual

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installing Power Components

- Wiring Brochure Zone Manager 335

Rental Industry Safety Tester Safe Check 5s

High Frequency SineWave Guardian TM

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

CP /240-MC4 User Manual

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Technical Manual. DLM Module. This manual should remain with the unit.

Supply-Side PV Connections

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Elegance Electrician s Installation Guide

Powerware Vdc Extended Battery Cabinet User s Guide.

Instruction Book for. ContouR ElECtRol

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

- Wiring Brochure Zone Manager 336

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

Sunwize Water Pumping Kit Quick Start

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

innovations in battery charging

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Assessing a Site for Installation of Consumption Monitoring

The Da-Lite Difference.

Uninterruptible power supply Supply MEg101.4

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

BLUE 3 INSTALLATION GUIDE

ET-PWR-END-KIT Installation Instructions (part #JSR00)

PowerPlex 40V MAX Standard Battery Pack/Charger

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

Definitions. Scope. Customer Generation Interconnection Requirements

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION GUIDE AND USER MANUAL

i-energy i-micro inverter GT260

OBAE, OBAEXU, ON BOARD Battery Chargers

INSTALLATION GUIDE AND USER MANUAL

Electric. PN April Series Electric Oven

Owner's Manual 600 and 800 Amp RTS Automatic Transfer Switch

Installer Guide smart connect

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

Owner s Manual. For Automatic Transfer Switch. 100 Amp. Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

LED IMPORTANT SAFETY INSTRUCTIONS

PSX-240 Enclosed Autotransformer Installation Manual

SAVE THESE INSTRUCTIONS

METERING REQUIREMENTS

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

GS-IOB-120/240VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

ONE TOUCH CONTROL BOX

Electric Vehicle Charging Station

The Da-Lite Difference.

Using OutBack Inverters for 3-Phase 480V Applications

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Connecting to DC Power

B BASIC HEAT TREATMENT CONSOLE

Actionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

i400s Calibration Information Introduction

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK

Owner's Manual. LTS Load Shed Switch. This manual should remain with the unit.

Installation Instructions

Owner's Manual. LTS Load Shed Switch. This manual should remain with the unit.

Dominion PX. Quick Setup Guide. Before You Begin. Mounting Zero U Models Using L-Bracket. Zero U Size. 1U and 2U Size

Service Entrance Methods

AIS and 40 kva 400 V. Site Preparation and Installation Manual

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

Apollo Solar Inverter Switchgear Module Installation Manual Rev 1.2 Page 1

O & M Manual for the EATON Generator Ready Loadcenter

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

The Da-Lite Difference.

Transcription:

I n s t a l l a t i o n M a n u a l f o r T E D 5 0 0 0

Page 2 N O T I C E - I M P O R T A N T T E D O P E R AT I O N A L L I M I TAT I O N S TED is only suitable for use on 120/240V single-phase 60Hz services. TED is only suitable for services of 200 Amps or less, or 400 Amps with parallel 200A feeds. TED is only suitable for services with maximum 350 MCM conductors. TED 5000 Energy Management System complete system includes: - Two (2) Current Transformers (CTs) - One (1) Measuring Transmitting Unit (MTU) - One (1) Gateway (with Footprints firmware embedded) - One (1) Display (if purchase included Display) - One (1) Display Recharging Stand (if purchase included Display) - Associated cables, power supplies; SAFE OPERATING RANGE AND CONDITIONS: Use Condition Temperature Relative Humidity Altitude Voltage Display & Gateway Indoor Dry 10-40 C < 80% 3,300M 100-130 V MTU & CTs Indoor/Outdoor Dry /Damp 0-40 C < 90% 3,300M 100-250 V If any of the following are true, this version of TED WILL NOT work: If you have a 3-Phase service, TED WILL NOT work. If you have a 230V 50Hz service typical in most areas outside North America, TED WILL NOT work. If your main service circuit conductors (wires) are larger than 1-inch diameter, TED WILL NOT work. Other TED models may be available for these applications. Please see our web site for details - www.theenergydetective.com

Page 3 T A B L E O F C O N T E N T S PART I PART II PART III PART IV Introduction.................................. Page 4 Safety....................................... Page 6 Quick Start Installation......................... Page 9 (For Electricians and Professional Installers ONLY) Solar/Wind Installation........................ Page 12 Energy, Inc. 3297 Pacific Street Charleston, South Carolina 29418 (843) 766-9800

Page 4 I N S T A L L A T I O N M A N U A L The Installation of TED is intended for professional electricians or highly technical amateurs only. P A R T I I N T R O D U C T I O N This brief manual summarizes the steps necessary to safely install the MTU and Current Transformers (CTs). For detailed installation and operation of other components and software, please refer to the HELP Section of the TED Footprints Software, find it on the TED 5000 Footprints CD, or check out the TED website at www.theenergydetective.com.

Page 5 U n p a c k i n g Unpack TED and ensure that all parts are included in the package. A) One (1) Display (if purchase included Display) B) One (1) Display Recharging Stand (if purchase included Display) C) One (1) Measuring Transmitting Unit (MTU) D) One (1) Gateway. E) Power Cable for MTU, Ethernet Cable, Low-voltage power adapter (for optional Display) F) Two (2) Model QX200CT Current Transformers (CT s) G) Installation Manual - Please Read Carefully Energy, Inc. 3297 Pacific Street Charleston, South Carolina 29418 (843) 766-9800

Page 6 P A R T I I S A F E T Y Every effort has been made in providing for the safe, secure installation of TED. The installation of TED requires the cover of the main electrical circuit breaker panel to be removed. After the circuit breaker panel has been removed, the potential hazard of shock, burn, or even electrocution now exists. Do not attempt to complete this installation unless you are very familiar with the electrical components and operation of the circuit breaker panel. Even when the main circuit breaker has been turned to the OFF position, certain areas within the circuit breaker panel may still be electrified. Do not attempt installation unless you know where these electrified areas are. This symbol will be found throughout the instructions where there is a potential for electric shock, burn, or even electrocution. Do not attempt to complete the noted section if you are not an electrician, or qualified installer. WARNING - These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, DO NOT perform any servicing other than that contained in these operational instructions, unless you are qualified to do so. WARNING - The MTU must be connected to a switch or circuit breaker in close proximity to the equipment and within easy reach of the operator. It must be marked as the disconnecting device for the MTU. WARNING - If the equipment is used in a manner not specified in these instruction, the protection provided by the equipment may be impaired. Energy, Inc. Model 5000 TESTED TO COMPLY WITH FCC STANDARDS FOR HOME AND OFFICE USE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operations.

Page 7 B E F O R E Y O U S T A R T Do not begin installation until you have read the Safety section of this manual. Read all instructions before beginning installation. Estimated Installation Time: Professional Installer: 15 minutes Equipment Needed: - Flathead screwdriver - small and large - Phillips screwdriver - small and large - Flashlight QUALIFIED ELECTRICIANS OR PROFESSIONAL INSTALLERS FAMILIAR WITH ALL ASPECTS OF ELECTRICAL WIRING AND THEORY, MAY USE THE FOLLOWING CONDENSED INSTRUCTIONS FOR INSTALLATION OF TED. NON-PROFESSIONALS SHOULD READ AND FOLLOW THE DETAILED INSTRUCTIONS INCLUDED ON THE TED 5000 FOOTPRINTS CD TED is suitable for installation on a single 120/240V single phase 60Hz service, normally found in North America (USA, Canada, Mexico and portions of the Caribbean). It is not suitable for three-phase service, or for service where there are more than two main circuit breaker panels or for 230V 50Hz service commonly found in other regions of the world. All wiring in the United States must be installed in accordance with the latest adopted edition of the National Electrical Code (ANSI/NFPA 70, NEC) and state or local requirements. All wiring in Canada must be installed in accordance with the latest adopted edition of the Canadian Electrical Code (CSA C22.2 CEC, Part I) and any provincial or local requirements. Energy, Inc. 3297 Pacific Street Charleston, South Carolina 29418 (843) 766-9800

Page 8

Page 9

Page 10 Quick Start Installation STEP 1 - INSTALLING THE POWER CABLE AND MEA- SURING TRANSMITTING UNIT (MTU). (Refer to FIG 3) TURN OFF ALL POWER TO THE CIRCUIT BREAKER PANEL BY TURNING OFF THE MAIN BREAKER OR MAIN SWITCH. A) Turn off power. B) Remove circuit breaker panel cover. C) Note the ID Number of the MTU as shown on the label. It consists of six digits in the form 12 34 56. You will need to know this number to connect the MTU to the Gateway Network. D) Connect the black and red wires from the MTU power cord to a spare 15,20 or 30 Amp two-pole circuit breaker in the panel. E) Note that the black and red wires must create a 240V circuit. They cannot be connected to circuit breakers on the same phase. If there is no spare circuit breaker, the black/red wires can be attached to any 15, 20 or 30 Amp 2-pole cir-cuit breaker in the panel, provided that the circuit breaker is approved for 2 conductors (most are) and this is acceptable to the authority having jurisdiction in the installation location (it is generally acceptable); If a 2-pole circuit breaker is not available, then use an approved handle-tie to create one. F) Connect the white wire from the MTU to the neutral bus on the panel. G) Do not connect the Power Cable to the MTU until you have the CTs connected (see below) STEP 2 - INSTALLING AND CONNECTING THE CURRENT TRANS- FORMERS (CTs) A) CAUTION IF THIS IS A COMBINATION PANEL, THE LUGS ON THE PRIMARY SIDE OF THE MAIN BREAKER ARE PROBABLY STILL HOT. B) The CTs must be installed with the red polarity dots either both facing towards the main breaker, or both away from the main breaker to maintain the correct polarity. If both CTs are not installed in this manner, the readings will be wrong. Note: Do not install the CT over the neutral (N) (grounded) conductor. Energy, Inc. 3297 Pacific Street Charleston, South Carolina 29418 (843) 766-9800

Page 11 C) Install one CT over each incoming power line A or B, by pressing on the handle to open the split-core then clipping it over the power line as shown below. Press Here D) The CTs should be installed on the secondary side of the main switch or main circuit breaker, however, if this is not possible, such as in the case of a combination breaker panel, then install on the primary side of the main breaker. E) Make sure the thumb-squeeze split core CTs clamp tightly. (The CTs should be loose-fitting around the wires). F) Connect the CTs and Power Cable to the MTU by plugging the plastic mating connectors together. Note: The connectors are polarized and can only be inserted one way do not force. G) Determine the best location to mount the MTU. a. Choose a location where it will not interfere with existing equipment or wiring. b. The MTU may be attached using double-sided tape (if allowed in your jurisdiction), or with sheet metal or machine screws. H) Arrange and tie-wrap all wiring in a neat and tidy manner. I) Turn the power back on. The MTU will blink approximately 10 times when power is first applied. After this, it will blink when transmitting or receiving data. Do not close the electrical panel until you have completed the installation of the Gateway and verified that correct data is being received from the MTU. If, after the entire system is setup, and the energy being displayed seems very low, or incorrect, try reversing one of the CTs (either one of them). Close the Electrical Panel only after you have confirmed the correct operation of TED, Step 3 Refer to Quick Start Guide for detailed instructions on installing the Gateway and Display Devices, setup and operation of the TED Energy Management System.

Page 12 Solar, Wind or Auxiliary Generator Installation Addendum Installing the Solar/Wind, or Auxiliary Generator components ( Solar for short) needs to be completed after the installation instructions have been followed for the installation of MTU 1 (beginning on page 6 of this Instruction Guide). ` Assuming that you have successfully installed MTU 1 as detailed above, it is time to connect MTU 2 to your Solar system. While there are many different variations in Solar connections, we are presenting the installation of MTU 2 in the most common scenario. Solar panels connect to an inverter which changes DC to AC. In most cases it will be 120/240V. The connection can tie into the main switch/circuit Breaker, a transfer switch, a junction box, a splitter box, etc. It really doesn t make any difference. In the case of an auxiliary generator, it will likely tie into a transfer switch because generally speaking, a generator is not run in parallel with the utility. (You will use both CTs if 240v...otherwise, if it is 120V, you only use one CT). In the following drawing, the MTU/CTs are connected similarly as you did connecting MTU 1. If possible, both MTUs should be powered from the panel. This will give the cleanest Power Line Carrier signal. (Try NOT to power the MTU from the inverter, as there will be a lot of line noise that could interfere with the signal).

Page 13 3297 Pacific Street Charleston, South Carolina 29418 (843) 766-9800 (800) 959-5833 www.theenergydetective.com