High Performance Vacuum Pump Model 15401/15601/15605 Operating Manual... 2

Similar documents
High Performance Vacuum Pump Model 15120A/15121A Operating Manual...

Operating Manual. High Performance Vacuum Pump Models and 15600

High Performance Vacuum Pump Model 15401/15601/15603/15605/15607 Operating Manual... 2

High Performance Vacuum Pump Model 15120A/15122A Operating Manual... 2

Models

Models

Models

VACUUM PUMP. Please read the operating manual carefully before using.

VACUUM PUMP SERIES VP & VPC SINGLE - DUAL STAGE VACUUM PUMPS OPERATION MANUAL

YELLOW JACKET. SuperEvac Vacuum Pump for Ammonia and NH 3 Systems. Operation and Maintenance Manual. Models and Table of Contents Page

Air / Hydraulic Pump

348002K/348012K Manifold Block Style Service Manual 12/2000

Owner s Manual. Model Air Conditioning Component Flusher

VPC Series 18VDC CORDLESS VACUUM PUMP OPERATION MANUAL

Automotive Air Conditioning Manifold Gauge Sets

4, 6, 8 & 11 Su p e r Ev a c Vacuum Pumps

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

High Lift Transmission Jack

MOTORVAC. BrakeVac-II. MODEL NUMBER Brake Fluid Service System. Operator Manual MotorVac

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

High Lift Transmission Jack

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Eurovacuum Installations and Operating manual EV Series Vacuum pumps Models

Hydro-Sync Slide-Out System

Two Stage Rotary Vane Vacuum Pumps Operation and Maintenance Manual

Operating instructions Form no safety definitions

Dual Voltage Motor Power Conversion (if applicable)

WEBER CARBURETOR TROUBLESHOOTING GUIDE

Portable Electric/Gas Compressor Operating Instructions

High Lift Transmission Jack Max. Capacity: kg (1,000 lbs.)

INSTRUCTION MANUAL. Leakfinder. Model No. 625-WV609. BMW Smoke Tester. Diagnostic Smoke Vapor. with UltraTraceUV Dye Solution

Deister Machine Company, Inc. Heavy Duty System Saver Operating Instructions

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

GROUP CONTENTS GENERAL DESCRIPTION RADIATOR SPECIAL TOOL THERMOSTAT ENGINE COOLING DIAGNOSIS...

Binks MODELS & AGITATOR DRIVE UNITS

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

WALKIE HIGH LIFT HYDRAULIC SYSTEM

BrakeVac EBB1000 Brake Service System

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

Air / Hydraulic Under Axle Jack

FTIR PG28 PURGE GAS GENERATOR OPERATIONS & MAINTENANCE

No Infrared Refrigerant Leak Detector

HCFCs Refrigeration Retrofit Guidelines

BrakeVac-II Brake Fluid Service System

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

ENGINE COOLING GROUP CONTENTS RADIATOR GENERAL DESCRIPTION SPECIAL TOOLS THERMOSTAT

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

High Lift Transmission Jack

Under Axle Jack Max. Capacity: 25 Tons

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Operator s Manual. Diagnostic Smoke Vapor Machine. with UltraTraceUV Dye Solution. Smoke Wizard Leak Detection System Model GLD-50

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

Viscount I Hydraulic Motor and Displacement Pump

Fuel System Service & Diagnostic Equipment OPERATOR S MANUAL MCS 245

DURAVAC RP SERIES MANUAL. Oil Lubricated, Rotary Piston Vacuum Pumps INSTALLATION OPERATION. Models RP-35 & RP-50 WARNING

SD Bendix M-21 and M-22 AntiLock Modulator Assembly DESCRIPTION M-21 MODULATOR M-22 MODULATOR

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

Air-Powered Mixers. Operation and Maintenance Instructions INTRODUCTION

TRIVAC NT, Two-Stage Rotary Vane Vacuum Pumps TRIVAC NT 5 to NT 25

Installation Operation and Maintenance Manual

Congratulations PRE-OPERATION SETUP

Collision Repair Set. Form No No. 1517A 4-Ton Set. No. 1519A 10-Ton Set. Parts List & Operating Instructions for: 1519A. Part No. Item No.

Air / Hydraulic Pump Instructions. CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine.

MODEL SAFETY & INSTRUCTION MANUAL

6L Oil-less Air Compressor 53103

ABSOLUTE EQUIPMENT PTY LTD

3M TM Filter Housing 1BS-T/1BS-TW Series

Battery Powered Hydraulic Pump; Kit PN [ ]

MODEL NO. TSSK GALLON SKID-MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

LC I LIPPERT COMPONENTS HYDRAULIC FULL WALL SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL

Installation and Operating Manual

Forklift Jack. Scissors Max. Capacity: 4 ton Scissors Low Height: 2-5/32 in. (55 mm) Scissors High Height: 17-29/32 in. (455 mm)

ABSOLUTE EQUIPMENT PTY LTD

VACUUM PUMP SYSTEMS. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

D-Series Blowers and Exhausters

Models: 8500, 8501, 8513, 8514, 8500BL, 8501BL, 8513BL, 8514BL, 8540, 8541, 8550, 8551, 8540BL, 8541BL, 8550BL & 8551BL

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual

CHAPTER 12 SERVICING. Section Title Page

TC Series Cooling Systems

TS1251 PRESSURE DISPENSER USER'S MANUAL

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-630

Low Lift Transmission Jack

McGUIRE AIR COMPRESSORS HP RECIPROCATING AIR COMPRESSORS. R-Series. McGUIRE AIR COMPRESSORS

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

PE 20 SERIES ELECTRIC POWER PUMPS

User s Manual D-Series Blowers and Exhausters

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

INOCULATION TANKS 15 GALLON # GALLON #

Spin Klin 3"-4" Apollo Angle

P5510. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Fuel Tank Sweeper #9049 OPERATOR S MANUAL

Operating Instructions & Parts Manual

Sullair: An Industry Leader

Instruction Manual. Maximum Operating Pressure 510 bar

Purging Air From Divider Block Lubrication Systems

1200W INVERTER GENERATOR

Transcription:

High Performance Vacuum Pump Model 15401/15601/15605 Operating Manual... 2 Bombas de Vacío de Alto Rendimiento Modelo 15401/15601 Manuel del Operador... 8 Pompe à Vide à Haut Rendement Modèle 15401/15601 Manuel d utilisation... 16 Hochleistungs-Vakuumpumpe Modelle 15401/15601 Bedienungsanleitung... 24

Operating Manual Table of contents Robinair high performance vacuum pumps...2 Pump components...3 Warnings...3 Before using your vacuum pump...4 To use the gas ballast feature...5 To shut down your pump after use...5 To maintain your high vacuum pump...5 Vacuum pump oil...5 Oil change procedure...5 Cleaning your pump...5 Motor lubrication...5 Troubleshooting guide...6 Failure to start...6 Oil leakage...6 Failure to pull a good vacuum...6 Pump specifications...6 Replacement parts...7 Warranty coverage...7 Out of warranty...7 For use on A/C-R systems using CFCs, HCFCs and HFCs in conjunction with mineral oil, ester oil, alkylbenzene oil and PAG oil as lubricants. Not for use with ammonia or lithium bromide systems. Not for use with flammable refrigerants. Robinair high performance vacuum pumps Congratulations on purchasing one of Robinair s top quality vacuum pumps. Your pump has been engineered specifically for air conditioning and refrigeration service, and is built with Robinair s proven offset rotary vane for fast, thorough evacuation. You ll appreciate these key features... Iso-Valve TM Allows the pump to be shut off while still connected to the A/C-R system, which is handy for checking rate of rise. With the valve handle in the OPEN position, the pump is open to the system being evacuated. In the CLOSE position, the pump is isolated from the system. This minimizes pump oil pulled into the pumping module, making start-up easier and reducing wear and tear on the pump components. High vacuum rating The two-stage, offset rotary vane design provides powerful, quiet, high vacuum capability and ensures moisture removal, while the high pumping capacity reduces evacuation time. Lifetime filtration The intake filter prevents foreign matter from entering the pumping chamber, and an internal exhaust filter separates oil vapor from the exhaust flow. Directed exhaust The exhaust is expelled through the handle to direct it away from the service technician. Gas ballast A precise amount of atmospheric air is introduced into the pump, preventing condensation of moisture vapor and helping maintain the purity of the pump oil. By using the gas ballast, the pump operates more efficiently and pump life is extended. Sure-grip handle The one-piece, molded handle makes it easy to carry the pump to and from job sites, and the handle stays cool to the touch during operation. Compact design The pump measures approximately 40 cm long, while aluminum housing and offset rotary vanes keep the pump weight low, making it easy to carry. 2

11 12 1 2 3 10 4 9 Pump Components 1. Intake Fitting 2. Gas Ballast Valve (located beside handle base) 3. Oil Fill Port 4. Sight Glass 5. Die-Cast Aluminum Housing 6. Oil Drain 7. Molded Polycarbonate Base 8. Iso-Valve TM (isolates the pump from the system) 9. High Torque Motor 10. Power Switch 11. Through-the-Handle Exhaust 12. Sure-Grip Handle 8 7 Warnings Wear goggles when working with refrigerants. Contact with refrigerants may cause injury. Incorrect use or connections may cause electrical shock. Study and follow the instructions carefully. and take precautions to avoid electrical shock hazards. All associated devices must be grounded before energizing circuits. The normal operating temperature will cause certain external portions of the pump to be hot to the touch. Do not touch the pump housing or motor during operation. 6 5 Operating Manual NOTICE: Airborne Noise Emissions This equipment has been tested for airborne noise emission per the Council Directive for Machinery (89/392/EEC) Section 1.7.4 Instructions Essential Health and Safety Requirements. Sound levels do not exceed 80dB(A) actual value. 116292 Rev. F June 18, 2013 3

Before using your vacuum pump Operating Manual In all cases, motors are designed for operating voltages plus or minus 10% of the normal rating (see SPECIFICATIONS). 1. Verify the voltage and frequency at the outlet match the specifications on the pump motor decal. Verify the ON / OFF switch is in the OFF position before you plug the pump into an outlet. Verify the gas ballast valve is closed. Remove and discard the exhaust plug from the end of the pump s handle. 2. The pump is shipped without oil in the reservoir. Before starting the pump, fill with oil. Remove the OIL FILL cap (black plastic plug directly in front of the handle), and add oil until the oil just shows in the bottom of the sight glass. The approximate oil capacity of the pump is 375 milliliters. 3. Replace the OIL FILL cap and remove the cap from one of the inlet ports. Turn the Iso-Valve to OPEN. Turn the motor switch ON. When the pump runs smoothly, turn the Iso-Valve to CLOSED and replace the cap on the inlet port. This may take from two to 30 seconds, depending on the ambient temperature. After the pump runs for approximately one minute, check the sight glass for correct oil level oil should be even with the sight glass OIL LEVEL line. Add more oil if necessary. When the pump is running, the oil level should be even with the line on the sight glass. Underfilling will result in poor vacuum performance. Overfilling can result in oil blowing from the exhaust. Your pump is now ready to evacuate air conditioning and refrigeration systems. Follow normal service procedures and the A/C-R manufacturer s instructions for connections to the system. CAUTION! Before connecting the vacuum pump to an A/C-R system, remove refrigerant from the system in an accepted manner. Damage to the pump may occur if evacuation is started while the system is under high pressure. Robinair recommends use of our Refrigerant Recovery and Recycling equipment. Wiring Instructions: This vacuum pump features dual voltage ranges. Before operating the pump, read and follow these rewiring instructions (if necessary) to be sure your pump is wired for the appropriate voltage. CAUTION! Unplug the unit before beginning any service work. Incorrect use or connections can cause electrical shock. Only qualified personnel should perform service work. This vacuum pump is factory wired for a high voltage range of 220 to 250 volts. To wire the switch for a low voltage range of 110 volts to 115 volts, follow these steps: 1. Disconnect the unit from the AC power source. 2. Loosen the screws on the plate at the rear of the motor, and carefully move the plate aside to clear the opening. 3. Disconnect the leads and reconnect for low voltage, following the diagram and chart. (High voltage connections are also shown if you want to rewire in the future.) 4. Verify connections are secure and there are no short circuits. Verify the grounding connector is correctly connected. 5. Re-install the plate on the rear of motor with the screws which were loosened in Step 2. IMPORTANT: Check for short circuits using a continuity tester before reconnecting to the AC power source. NOTE: EXTERNAL POWER LEADS ARE ALWAYS CONNECTED TO TERMINALS 1 AND 4. EMERSON INTERNAL VOLTAGE CONNECTION MOTOR LOW HIGH LEAD VOLTAGE VOLTAGE BROWN 3 6 WHITE 4 3 BLACK 2 3 INST0350 4 General Electric Motors Emerson Motors

To use the gas ballast feature To maintain the high vacuum pump Moisture from the A/C-R system that is carried into the pump as a vapor tends to condense into a liquid and combine with the vacuum pump oil. When moisture contaminates the pump oil, it reduces the pump s ability to reach its ultimate deep vacuum level. The gas ballast valve purges a small amount of atmospheric air through the exhaust chamber. This extra volume of air mixes with the vapor from the refrigerant system to prevent condensation and to help exhaust moisture in the form of vapor from the pump. To use the gas ballast, start the pump and open the gas ballast valve until the system has reached approximately 1000 3000 microns. Close the valve to allow the pump to pull down to its ultimate vacuum level. (The gas ballast valve is located beside the handle, opposite the inlet fitting.) The gas ballast valve may be opened or closed at any time during pump operation. It is fully open at two turns counterclockwise. NOTE: Robinair recommends the use of a thermistor vacuum gauge to most accurately measure vacuum levels. To shut down the pump after use To help prolong pump life and promote easy starting, follow these procedures for shutdown: 1. Close the manifold valve between the pump and the system. 2. Turn the Iso-Valve to the CLOSED position. 3. Remove the hose from the pump inlet. 4. Turn the pump power switch to OFF, then return the Iso-Valve to the OPEN position for a few seconds to relieve any vacuum inside the pump. 5. Cap the inlet port to prevent any contamination or loose particles from entering the port. For maximum performance, Robinair recommends changing vacuum pump oil after each use. Vacuum pump oil The condition and type of oil used in any high vacuum pump are extremely important in determining the ultimate attainable vacuum. Robinair recommends the use of our Premium High Vacuum Pump Oil. This oil has been specifically blended to maintain maximum viscosity at normal running temperatures and to improve cold weather starts. Our Premium High Vacuum Pump Oil is available in quart or gallon containers. Order by part number: 13203 Quart (shipped 12 quarts per case) 13204 Gallon (shipped 4 gallons per case) Oil change procedure 1. Be sure the pump is warmed up. 2. Remove the OIL DRAIN cap. Drain contaminated oil into a suitable container and dispose of correctly. Oil can be forced from the pump by opening the inlet and partially blocking the exhaust with a cloth while the pump is running. Do not operate the pump for more than 20 seconds using this method. 3. When the flow of oil has stopped, tilt the pump forward to drain residual oil. 4. Replace the OIL DRAIN cap. Remove the OIL FILL cap, and fill the reservoir with new vacuum pump oil until the oil just shows at the bottom of the sight glass. The approximate oil capacity of the pump is 375 milliliters. 5. Verify the inlet ports are capped. Turn ON the pump, and allow it to run for one minute. Check the oil level. If the oil is below the sight glass OIL LEVEL line, add oil slowly (with the pump running) until the oil reaches the OIL LEVEL line. Replace the OIL FILL cap, cap the inlet, and tighten the drain cap. 6. If the oil is badly contaminated, you may need to flush the pump. To flush, remove the pump drain cap and start the pump. Slowly pour a small quantity of new pump oil through the oil fill inlet. Repeat this procedure as required until the contamination is removed. Replace the OIL DRAIN cap and refill the reservoir to the correct level using fresh pump oil (Step 4). Cleaning the pump Use only soap and water to clean the pump. Do not use commercial cleaners that contain degreasing agents that can damage polycarbonates. The pump handle and base are made of Lexan, one of the toughest polycarbonate plastics available. However, it is sensitive to degreasing agents. *Lexan is a registered trademark of General Electric Motor lubrication After three years of normal service or one year of heavy-duty service, add motor oil. Use electric motor oil or SAE 10 oil. Operating Manual 5

Operating Manual Troubleshooting guide This pump has been designed for dependable use and long life. If something should go wrong, however, the following guide will help you get the pump back into service as quickly as possible. If disassembly of the pump is required, please check your warranty. The warranty may be voided by misuse or customer tampering that results in the pump being inoperable. Failure to start Check line voltage. Robinair pumps are designed to start at +10% line voltage (loaded) at 0 o C. At extremes, however, switching between the start and run windings may occur. When starting the pump in cold temperatures, verify the Iso-Valve and inlet port are open to free air. Oil leakage 1. Verify the oil is not a residual accumulation from spillage, etc. 2. If leakage exists, the module cover gasket or the shaft seal may need replacing. Follow the instructions supplied with the seal replacement kit, part number 15367. If leakage exists in the area of the drain plug, reseal the plug using a commercial pipe thread sealer. Failure to pull a good vacuum 1. Verify the Iso-Valve on the pump is in the OPEN position, and the gas ballast knob is tightly sealed. 2. Verify the vacuum gauge and all connections are in good conditon and leak-free. Confirm leakage by monitoring the vacuum with a thermistor gauge while applying vacuum pump oil at connections or suspected leak points. Vacuum will improve briefly while the oil is sealing the leak. 3. Be sure the pump oil is clean. A badly contaminated pump may require several oil flushes. See OIL CHANGE PROCEDURE. 4. Verify the oil is at the correct level. For maximum pump operation, the oil must be even with the OIL LEVEL line on the sight glass when the pump is running. See OIL CHANGE PROCEDURE. Do not overfill. Operating temperatures cause the oil to expand, so it will appear at a higher level than when the pump is not running. To check the oil level, start the pump with the inlet capped. Check the oil level in the sight glass. Add oil if necessary. Pump Specifications Model 15401 Frequency Range... 50-60 Hz Free Air Displacement...4 cfm/60 Hz... 94 l/m @ 50 Hz... 113 l/m @ 60 Hz Stages...2 Motor Speed...1425 rpm @ 50 Hz...1725 rpm @ 60 Hz Voltage Range...110V 115V... 220V 250V Factory Micron Rating... 15 microns Approximate Oil Capacity... 400 ml Weight... 13 kg Width... 14.29 cm Height... 24.6 cm Length... 40 cm Intake... 1 /4" and 1 /2" SAE MFL Min. Starting Temp. (at 90% voltage)... 0 o C Motor Size... 0.25kW (½ HP) Capacitor Start Operating Temp... 68 o C Models 15601 and 15605 Frequency Range... 50-60 Hz Free Air Displacement...6 cfm/60 Hz... 142 l/m @ 50 Hz... 170 l/m @ 60 Hz Stages...2 Motor Speed...1425 rpm @ 50 Hz...1725 rpm @ 60 Hz Voltage Range...110V 115V... 220V 250V Factory Micron Rating... 15 microns Approximate Oil Capacity... 400 ml Weight... 13 kg Width... 14.29 cm Height... 24.6 cm Length... 42 cm Intake... 1 /4", 3 /8", and 1 /2" SAE MFL Min. Starting Temp. (at 90% voltage)... 0 o C Motor Size... 0.25 kw (½ HP) Capacitor Start Operating Temp... 68 o C Notes: 1. All motors are internally protected (automatic reset). 2. Operating temperatures are typical for normal operating conditions. 3. Model 15603 has a bipolar side grounded plug. 4. Models 15405 & 15605 have Australian plugs. Because of ongoing product improvements, we reserve the right to change design, specifications, or materials without notice. 6

12 11 9 8 9 9 7 13 14 6 5 15 4 3 INST0026 Replacement parts 15605/ 15601/ Part Item 15401 15603 Oil Drain Cap (6) 1 40572 40572 Oil Drain Kit (includes Item No. 1) 2 13193 13193 Module Cover Kit (includes Nos. 2, 4, and 5) 3 15337 15337 Oil Fill Cap (includes No. 7) 4 15371 15371 Intake Fitting (includes No. 9) 8 15364 555124 Intake Cap (1 ea.) 1 /4", 3 /8", 1 /2" SAE MFL 9 555133 555133 Vent Bolt (includes o-rings) 11 15338 15338 Handle, Power Cord and Switch Assembly 12 15466 15466 Motor 13 15465 15465 Coupling 14 13192 13192 Iso-Valve TM Assembly 15 15368 15368 Base and Foot Assembly 16 15369 15369 Pump Assembly, less motor (includes No. 3 and 6) 17 15547 15548 Seal Replacement Kit (not shown) -- 15367 15367 16 17 Warranty coverage Robinair vacuum pumps are warranted against defects in material and workmanship for one year of normal use from the date of purchase. See your distributor for warranty details. Out of warranty A pump which is no longer covered by the oneyear warranty period and which fails to operate properly should be returned to the distributor with a full written explanation of the problem. The distributor may suggest returning the pump to the factory. Before returning an out-of-warranty pump, review all maintenance procedures to avoid an unnecessary return. Replacement parts are available for doing your own service. 2 1 Operating Manual 7

Call our Toll-Free % Technical Support Line at 800-822-5561 in the continental U.S. and Canada or visit our website www.robinair.com In all other locations, contact your local distributor. To help us serve you better, be prepared to provide the model number, serial number, and date of purchase of your unit. To validate your warranty, complete the warranty card attached to your unit and return it within ten days from date of purchase. NATIONWIDE NETWORK OF AUTHORIZED SERVICE CENTERS If your unit needs repairs or replacement parts, contact the service center in your area. For help in locating a service center, call the toll-free technical support line, or visit our website. Due to ongoing product improvements, we reserve the right to change design, specifications, and materials without notice. BOSCH AUTOMOTIVE SERVICE SOLUTIONS INC. 655 EISENHOWER DRIVE OWATONNA, MN 55060 USA TECHNICAL SERVICES: 1-800-822-5561 FAX: 1-866-259-1241 CUSTOMER SERVICE: 1-800-533-6127 FAX: 1-800-283-8665 WEB SITE: WWW.ROBINAIR.COM 116292 Rev. G Bosch Automotive Service Solutions Inc.