Today, we re going to talk about battery safety. We ll discuss all the key issues associated with using batteries safely, including battery hazards,

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

FLUSH EYES IMMEDIATELY WITH WATER. GET MEDICAL HELP FAST. SULFURIC ACID CAN CAUSE BLINDNESS OR SEVERE BURNS.

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

RoaDCharger 20 Amp 7 Way Installation Manual

Vehicle battery BATTERY WARNING SYMBOLS BATTERY CARE

INSTALLATION AND OPERATION MANUAL

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP MOTIVE POWER BATTERIES

Mini Pump Installation, Operation & Maintenance Manual. For Models: BA-MS-633

INSTALLATION AND OPERATING INSTRUCTIONS FOR FLOODED TUBULAR-HP AND TUBULAR-LM FAST CHARGE MOTIVE POWER BATTERIES

MATERIAL SAFETY DATA SHEET MSDS009. Ultralife Batteries, Inc Technology Parkway Newark, NY

The information in this guide will allow response to emergencies involving Balance Hybrid E450 vehicles.

Installation instruction

VRLA Batteries. Battery Installation And Start up Guide

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

IMPORTANT SAFETY INSTRUCTIONS

PAGE 1 OF 6 HEALTH, SAFETY & ENVIROMENTAL MANUAL PROCEDURE: S450 Motor Vehicle Safety REV /01/09

MP V 8A Electronic Smart Charger. Instruction and Information Manual

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

Battery Capacity Analyzer

PS01 Personnel Safety

PSJ-2212, PSJ-3612, PSJ-4424

SECTION 7 3 DO IT YOURSELF MAINTENANCE MR2 U. Electrical components

Regulated Hose Supply Installation, Operation & Maintenance Manual

Model: SE-4020-CA Automatic Battery Charger

AT125-B ASSEMBLY INSTRUCTIONS

JOHN DEERE WORLDWIDE COMMERCIAL & CONSUMER EQUIPMENT DIVISION. Lawn Tractors L100, L110, L120, and L130 TM2026 DECEMBER 2002 TECHNICAL MANUAL

BATTERY & STARTER ANALYSER (BSA-12) User Manual

20W Polycrystalline Solar Panel

OWNERS MANUAL Models: XP400, XP500, XP750C INSTANT POWER Jump Starter and DC Power Source

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

INSTANT JUMPSTARTING POWER USER MANUAL. Copyright PowerStation, LLC All rights reserved MODEL: PS1100

Operator Manual. The most important component is you. This operator manual. has information for. all models of series. B plus some options and

User s Manual. Automatic Switch-Mode Battery Charger

LESTRONIC II BATTERY CHARGER MODEL 07210

Installation, Operation & Maintenance Manual

BATTERY 8A - 1 BATTERY CONTENTS

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

Section 1 - Product identification. Section 2 - Composition/information on ingredients. Section 3 - Hazards identification MATERIAL SAFETY DATA SHEET

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

NILFISK BA 500 Service Manual

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

BATTERY 8A - 1 BATTERY CONTENTS

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

Batteries and more. Powered by (CE, UL & ISO9001 APPROVAL)

Management Plan for Aerial Lifts (ANSI/SLA ) ISD #535

Operator Manual. This operator manual has. information for all models. of series M plus some. options and accessories. Some of the illustrations

518xi, 520xi & 522xi GARDEN TRACTOR

- Optional Audio warning when discharge test is complete or tester malfunction.

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

PW Operator Manual PW This operator manual. has information for all. models of series PW plus some options. and accessories.

BK10 10 CHANNELS BANK CHARGER For 12V lead-acid batteries

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

Installation, Operation & Maintenance Manual. For Pro-Fill kits with part numbers beginning in BG

SP6. Automatic Battery Charger. Model

SAFETY DATA SHEET. Section 1-Product and Company Identification. Section 2 Hazards Identification. Reference No.JHT1501

Operating conditions of VRLA batteries in HVCBS and LVDBS Systems

IEEE IAS Atlanta Chapter

SAFETY DATA SHEET. In Accordance with OSHA Standard APP D (USA)

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS MAINTENANCE MANUAL SUPPLEMENT. CONCORDE TS-C2 or TS-C2A TEMPERATURE SENSOR

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

FlexCharger Battery Chargers

Installation & Maintenance Manual

Models: SP3, SPSS3 Automatic Battery Charger

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS COMPONENT MAINTENANCE MANUAL CONCORDE VALVE REGULATED LEAD-ACID RG-441 BATTERY AUTHORISED UNDER TSO-C173

500A & 800A Jumpstarter

EnergyCell FLA Series. Owner s Manual

NB Module. Installation and Operation Manual. California Proposition 65 Warning:

Single-Point Watering Kit User s Guide

BEST 6042 BATTERY TESTER

12V Manual Battery Charger

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

Installation Instructions for Aux 101 Kit A044Z055

Special Post Crash Safety Considerations

800 Amp Heavy-Duty Jumpstarter

GSL Electronics Modified Sine Wave Power Inverters

BATTERY CHARGER CHR-1445

JOHN DEERE WORLDWIDE COMMERCIAL & CONSUMER EQUIPMENT DIVISION. Lawn Tractors L100, L110, L120, and L130 TM2026 DECEMBER 2002 TECHNICAL MANUAL

C&D Technologies, Inc. Dynasty Division 900 East Keefe Avenue Milwaukee, WI53212 Phone: Fax:

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

FULLY AUTOMATIC SCR BATTERY CHARGER

Chapter 3. Direct Current Power. MElec-Ch3-1

Changing light bulbs. Introduction WARNING

Battery. Student booklet

COMPONENT MAINTENANCE MANUAL HCU-2 HEATER CONTROL UNIT (AND ASSOCIATED BATTERY HEATING ELEMENT)

OBE, OBEXU, ON BOARD Battery Chargers

Battery Management Innovation DIAGNOSTIC CONDUCTANCE CHARGER. For testing and charging 12-volt automotive batteries INSTRUCTION MANUAL

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS MAINTENANCE MANUAL SUPPLEMENT CONCORDE TS-C1 SERIES TEMPERATURE SENSOR

New Bremen, Ohio USA 2004 PF14387-WEB Rev. 6/06 Printed in U.S.A.

Material Safety Data Sheet

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

TESTER ISOLATION MODULE LIGHT SYSTEM. Operating Instructions. CAUTION Read this document before testing any snowplows.

MASTERsine Inverter PXA Series Installation Guide

BS20 BATTERY CHARGER For lead-acid batteries


INSTALLATION AND OPERATION MANUAL

BusPro Series Instruction Manual

Transcription:

Basic Battery Safety Lead Acid Storage Batteries

Hazards of Lead Acid Batteries Chemical burns (sulfuric acid) Arc flash / burns Shock Explosive gas (hydrogen) Fire Weight

Sulfuric Acid Safety PPE requirements Safety glasses Rubber gloves Face shield Rubber apron (Provide an eyewash within 10 seconds of battery charging/cleaning areas) Hazards Ph <7 Corrosive material Burns to skin Burns to eyes Never open the battery caps with your face directly over the battery.

Shock / Arc Flash / Burn Safety Never touch both battery terminals with your bare hands at the same time! Remove rings, watches, and dangling jewelry when working with batteries. The metal in the jewelry can cause shock and/or burn if they contact the battery terminals. Only use insulated, non-conducting tools to remove cell caps or when connecting or disconnecting jumpers. Never lay tools or other metal parts on top of a battery.

Hydrogen Safety

Hydrogen Safety A by-product of the battery s charging process. Lighter than air. Flammable in nature. Explosive mixture at 4 74% by volume of air. Can not taste or see the gas vapors. You can smell the acid in the battery if it heats up.

Fire Safety Do not smoke in battery charging areas. Prevent open flames, sparks, or electric arcs in battery charging areas. Charge batteries in a well ventilated area. Do not strike the sides of the battery with any spark producing item. Keep tools and other metallic objects away from uncovered batteries. Have an ABC dry chemical fire extinguisher in charging areas or readily available when servicing a battery.

Weight / Handling Safety Industrial batteries used on board passenger cars are heavy. Example: A locomotive sized 4-cell unit weighs 400 lbs+. Use appropriate equipment to load/unload batteries. Ensure you are trained in using the loading equipment. Ensure the battery is securely blocked in place and battery box covers secure prior to movement. Do not attempt to stop a battery if it slides out of the equipment.

Cleaning Batteries Wear safety glasses, face shield, rubber gloves & apron. Ensure an eyewash station is readily available. Dampen the top of the battery with water first. Place dry baking soda on battery. Let sit for a few minutes for acid to be neutralized. Rinse off with cold water. When adding water, use watering cans to avoid contact with acid and battery terminals.

Charging Batteries Don t overcharge. Leads to boiling of electrolyte, creating excessive heat and hydrogen gas. Shortens battery life. Follow manufacturer s recommended charging voltages, varies by battery type and chemistry. Beware the possibility of unregulated charging of batteries when powering a car from DC shore power. NEVER trainline different voltage cars together! Assure proper polarity when connecting battery chargers. Severe damage to equipment or explosion is possible. Giving the battery a reverse charge is also possible!

Safe Maintenance Practices Protect eyes from acid splash when removing cell caps. Keep tools and other metallic objects away from uncovered batteries. Ensure the battery s water cell levels are maintained. Only add water to charged batteries. Use baking soda to neutralize spilled acid.

Maintenance Tips Disconnecting leads: Do not leave leads loose on battery. Can short to other terminals or carbody, causing arcing and possible explosion. Connecting leads: Assure connections are clean and TIGHT. Damage to battery lugs and leads can result when drawing large currents through a loose terminal! Do not allow discharged batteries to freeze. Case may crack and cause battery to leak.

Quick Recap Know the hazards. Use the required PPE. No open flame. Follow manufacturer s instructions. Keep them clean. Keep them charged. Keep them watered.