The Council Directive 2009/23/EC on non-automatic weighing instruments.

Similar documents
EC t y p e - e x a m i n a t i o n C e r t i f i c a t e

EC Type-Approval Certificate UK 2655 Revision 2

Certificate of EC type-approval of a measuring instrument Number: UK 2489 Revision 4

OIML CERTIFICATE OF CONFORMITY

EC Type-Approval Certificate UK2853 Revision 4

UK Weighing Federation Technical Articles

OIML CERTIFICATE OF CONFORMITY

OIML CERTIFICATE OF CONFORMITY

Parts Certificate Certificate for a part of a measuring system for LOTW

OIML CERTIFICATE OF CONFORMITY

Evaluation Certificate

2015 NIST EPO No. 12

C e r t i f i c a t e

(Text with EEA relevance)

Parts Certificate. Outdoor Payment Terminal KT-OPT - including KT-Retail and KT-Account SC

XK3190- A7. Weighing indicator USER MANUAL

EU TOY DIRECTIVE 2009/48/EC: OVERVIEW - REGULATORY CONTEXT AND MAJOR CHANGES

Quick Guide. brite Advanced Retail scale

EUROPEAN UNION AGENCY FOR RAILWAYS Annex 1 006REC1025 V 1.0

PORTABLE AXLE WEIGHING SYSTEM CET 10-4 IN STATIC MODE TRUCKS OVERLOAD CONTROLS EUROPEAN APPROVED

EC type Examination Certificate

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

FUNCTIONS AND TECHNOLOGY OF DIGITAL TACHOGRAPHS SYSTEMS WITH CONTEMPORARY TELEMATIC SYSTEM IN ROAD TRANSPORT, ON BOARD INFORMATICS NET AND GPS SYSTEM

DIPARTIMENTO PER LA REGOLAZIONE DEL MERCATO DIREZIONE GENERALE PER LA VIGILANZA E LA NORMATIVA TECNICA TEST CERTIFICATE UCM 98/002-A - REVISION I

Top quality For industrial use

Switching DC Power Supply

2015 Food Scales Commercial Weighing Equipment

Standard Features and Options

LCB File No. R PROPOSED REGULATION OF THE STATE ENVIRONMENTAL COMMISSION

Model 8000XL OPERATOR MANUAL

Ohaus ES Series Bench Scale

Diploma in Consumer Affairs and Trading Standards LEGAL METROLOGY LAW NOVEMBER 2014

3000 Series T31 Indicators

ARAI/TA (4G)/AIRVISOR/AVG500/ Dated 17 th Apr 2017

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

COMMISSION REGULATION (EU) No /.. of XXX

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

(Non-legislative acts) DECISIONS

ARAI/TA(4G_RV)/SMS/D680/ Dated 21 st Mar 2015 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

Model 7400 OPERATOR MANUAL

Sartorius Cubis Series

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

English version of. Executive Order on vehicles' technical compatibility with the rail network (Bekendtgørelse nr af 30. november 2012) Preface

Certificate of Approval NMI 12/1/8

ARAI/TA(4G_RV)/HORIBA/MEXA 584L/ Dated 25 Mar 2014

BLU SERIES Battery Load Units

DC 5000 Series Crane Scale Instruction Manual

Operating Instructions (Translation)

Explanations. 6 Protection (IP-Code) acc. to DIN / IEC etc. Several Icons. Manufacturing process

Version / Status V 2.0 Date Author. Wagon Markings

WELMEC. European Cooperation in Legal Metrology

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

University of Houston Master Construction Specifications Insert Project Name

ARAI/TA(4G)/SMS/D680/ Dated 28 Jan 2010

Instruction Manual. Ex-Time 40 / 50

TYPE APPROVAL CERTIFICATE

QUESTION / CLARIFICATION

MEDICAL FLOOR SCALES. Medical, health and well-being. Product number 7716, 7717, 7718

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

LEVEL OF IMPLEMENTATION OF DIGITAL TACHOGRAPHS SYSTEM IN EUROPEAN UNION

ACS-2 Long and Short Term Endurance Indicators

PSU EN54-4 Power Supplies

11-Feb-14. VCA job number: CSP Date: 11 February Dear Sirs,

ARAI/TA(4G)/GEN-MAINT/EXOSCAN-V/ Dated 26 th Mar 2009 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES

ECOMP.3.A EUROPEAN UNION. Brussels, 12 December 2018 (OR. en) 2018/0220 (COD) PE-CONS 67/18 ENT 229 MI 914 ENV 837 AGRI 596 PREP-BXT 58 CODEC 2164

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

Stainless steel Material : DIN / /

WELMEC European cooperation in legal metrology

COMMISSION REGULATION (EU)

124 th MEETING OF THE WORKING GROUP ON "MOTOR VEHICLES" 20 October 2014 Agenda item 4:

Council of the European Union Brussels, 18 July 2014 (OR. en)

Rayleigh Instruments Ltd Raytel House Brook Road Rayleigh Essex SS6 7XH United Kingdom

one filter having K between 1.5 and 2.5 m -1

(submitted by the Dutch delegation)

TYPE APPROVAL CERTIFICATE

Specification of Battery Charger

EC type-examination certificate UK/0126/0072 Revision 2

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

DIGITAL CRANE SCALE MODEL: OCS-SP USER MANUAL

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Sentronic LP IO-Link CLASS A 617 Series. 617 Series IO-Link CLASS A with Display and Controls Installation Manual

IMPLEMENTATION OF DIGITAL TACHOGRAPH SYSTEM IN EUROPEAN UNION. Marcin Rychter. Motor Transport Institute, Poland. 1. Introduction

BODAS Pressure sensor PR3 series 10

Precisa Gravimetrics AG

MAS, MAS.1 weighing modules

How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

Implementation procedure for certification and continued airworthiness of Beriev Be-200E and Be-200ES-E

12468/10 SJC/fp 1 DG I 1A

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY

Guide for installers. METTLER TOLEDO MultiRange Explosionsproof weighing system with the ID3sTx weighing terminal.

Principle Decision by the Central Experience Exchange Circle of the Notified Bodies and the GS Bodies according to the Product Safety Act ZEK

Note. Solid version. TÜV-tested safety. Lisa Mayer Product specialist Hanging scales/crane scales

NI 9251 with mini XLR

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

medical/health scales

T29 series. Wash Down S cale. Technical Manual. TotalcompR. Scales & Components

Washdo. wn Scale Base

Transcription:

EC type-approval certificate Page 1 of 5 Issued by In accordance with Manufacturer In respect of Characteristics NMi Certin B.V. Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands The Council Directive 2009/23/EC on non-automatic weighing instruments. Ohaus Corporation 19A Chapin Road Pine Brook, NJ 07058 United States of America A class III, electronic, single interval non-automatic weighing instrument, intended to be used for direct sales to the public. Manufacturer mark/name : Ohaus Type : RH 6 kg Max 30 kg e 1 g n 6000 divisions T -(Max e) Temperature range -10 C / +40 C In the description number T7558 revision 2 further characteristics are described. Valid until 6 April 2019 Description and The instrument is described in the description number T7558 revision 2 and documentation documented in the documentation folder T7558-3, appertaining to this EC type-approval certificate. Remarks This revision EC type-approval certificate replaces the earlier versions, including its documentation folder. The Notified Body no. 0122 NMi Certin, 25 May 2012 C. Oosterman Head Certification Board NMi Certin B.V. Hugo de Grootplein 1 3314 EG Dordrecht The Netherlands T +31 78 6332332 certin@nmi.nl www.nmi.nl This document is issued under the provision that no liability is accepted and that the applicant shall indemnify third-party liability. The designation of NMi Certin BV. as Notified Body can be verified at http:// ec.europa.eu/enterprise/newapproach/nando/ Parties concerned can lodge objection against this decision, within six weeks after the date of submission, to the general manager of NMi (see Regulation objection and appeal against decisions of NMi www.nmi.nl) Reproduction of the complete document only is permitted

Description Page 2 of 5 1 General information about the non-automatic weighing instrument All properties of the non-automatic weighing instrument, whether mentioned or not, may not be in conflict with the legislation. 1.1 Essential parts See block diagram in drawing Main board wiring diagram, drawing number 7558/1-01; - The electronics; - The mechanical assembly with load cell. EMC protection measures: - For all instruments the following measures are valid: - Ferrite bead around the cable of the power supply (230 V side), 3 turns; - Ferrite bead on cable from main board to internal display board, 1 turn; - Two ferrite cores soldered on the main board (power supply connection); - Ferrite bead on cable from mainboard to A/D board; - The analog circuits on A/D board are enclosed in a metal shield box; - The electronics are enclosed in a metal box. 1.2 Essential characteristics Power supply: - 100-240 V AC, 50/60 Hz; - Internal rechargeable lead-acid battery 12 V (optional). 1.3 Essential shapes The non-automatic weighing instrument is built according to the drawing "Assembly RH", drawing number 7558/1-02. The data plate is secured against removal by sealing or will be destroyed when removed. To secure components that may not be dismantled or adjusted by the user, the non-automatic weighing instrument has to be secured in a suitable manner on the locations indicated in the drawing: - "Sealing bhigh-btwin", drawing number 7558/2-01. Inside the cabinet is a calibration lock, located on the A/D board. The calibration button protects the relevant part of the software. 1.4 Conditional parts The non-automatic weighing instrument may be equipped with peripheral equipment which is used for the applications listed in article 1(2)(a) of Directive 2009/23/EC, if the peripheral equipment is certified to be connected to an EC type-approved non-automatic weighing instrument by a Notified Body responsible for type examination under Directive 2009/23/EC. The non-automatic weighing instrument may be equipped with an Electronic Point of Sale (EPoS) or an Electronic Cash Register (ECR), if these EPOS and ECR are certified to be connected to an EC type-approved non-automatic weighing instrument by a Notified Body responsible for type examination under Directive 2009/23/EC.

Description Page 3 of 5 The non-automatic weighing instrument may be equipped with Electronic Funds Transfer equipment (EFT/ECU), if these EFT/ECU represent only the price total on the display. The hanging version of the instrument is placed in a fixed position and does not need a level indicator and/or a leveling device. 1.5 Non-essential parts The non-automatic weighing instrument may be connected to non-essential devices, for example but not limited to bar code readers, foot switches, second display s and cash drawers, provided that: - They do not present primary data used for purposes mentioned in article 1(2)(a) of Directive 2009/23/EC unless the "preliminary observations" in Annex 1 of this directive is satisfied; - They do not lead to an instrument having other essential characteristics than those fixed by this type-approval document. Battery. 2 Information about the main constituent parts of the non-automatic weighing instrument 2.1 The electronics 2.1.1 Essential parts Description Drawing number Rev. Remarks A/D PCB board assembly 7558/2-01 C Drawing including parts list Main PCB board assembly 7558/2-02 E Drawing including parts list 2.1.2 Essential characteristics List of devices: - Determination stability of equilibrium; - Zero indicator; - Semi-automatic zero-setting; - Initial zero-setting; - Zero-tracking; - Semi-automatic subtractive tare weighing; - Preset tare; - Calibration / service set-up mode via a calibration button on the main board; - Gravity compensation; - Acting upon significant faults; - Checking the display; - Price calculation; - Count mode; - Update of non-relevant software by means of RS232 port. When equipped with a printer the following devices may be present: - Indications other than primary indications;

Description Page 4 of 5 - Indication of additional information; - Memory storage; - Non-weighed articles; - Totalization; - Multi-vendor; - Price labeling instrument; - PLU function. 2.1.3 Conditional parts The interface section is located on the main. The non-automatic weighing instrument may be equipped with one or more of the following protective interfaces that have not to be secured: - 2 * RS232C; - Ethernet; - USB; - Drawer kick. 2.1.4 Non-essential parts Display; Keyboard; Internal printer. 2.2 The mechanical assembly with load cell 2.2.1 Essential parts Description Drawing number Rev. Remarks AMI-11kg (NEW) 7558/1-03 B For n 6000 divisions (C3,C6) AMI-22kg (NEW) 7558/1-04 C For n 6000 divisions (C3,C6) AMI-40kg (NEW) 7558/1-05 C For n 6000 divisions (C3,C6) 2.2.2 Essential characteristics - e E max /11000; - Excitation power supply 5 V DC. 2.2.3 Essential shapes See drawings: "Load cell assembly", drawing number 7558/1-06.

Description Page 5 of 5 3 Approval conditions See chapter 1.3, essential shapes. 4 Seals and verification marks See chapter 1.3, essential shapes. 5 CE-mark of conformity and inscriptions The marks, facilities for the marks and the inscriptions on the non-automatic weighing instrument fulfill the requirements of article 1 of Annex IV of Directive 2009/23/EC.