Door locking devices. 4 Schmersal Industrial Switchgear

Similar documents
Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

AZM 161SK 12/12RKED/TU 024

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Floor and fine adjustment switches

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Safety door-handle system STS

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Datasheet - MV8H Y

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Technical data. Standards: IEC/EN BG-GS-ET-15

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Solenoid interlock AZM 200 The non-contact interlock.

EG type-examination certificate

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

FL series position switches

onlinecomponents.com Compact Coded Magnetic Safety Interlock Switch and Control Unit

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Safety Sensor CSS 180 Product Information

Single foot switches - PX and PA series

SIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

SFS-UFS Single Foot Switches

Rotary limit switches FCR FGR series

FOOT SWITCHES

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Safety switches with solenoid and separate actuator

Position switches FD series

Safety switches / Position switches / Command devices

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

LR-LX-LK-LW Safety Switches with separate actuator

SNAP ACTION SWITCHES type SAS-00, SAS-03

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

ZB0050 / ZB0051 ZB0070 / ZB0071

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Position Switches Series 8060/2

Safety switches for hinges

ED SERIES SAFETY LIMIT SWITCH

Operating instructions Solenoid interlock AZM About this document. Content

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

SIGUARD Safety Systems Safety Integrated

IEC Limit Switches Selection Guide

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Safety switches with solenoid and separate actuator

LK Position Switches TECHNICAL DATASHEET.

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Position Switches Series 8070/2

Thermal Overcurrent Circuit Breaker 3120-F...

Switches with manual reset

Safety Switches Series 8537

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Thermal Overcurrent Circuit Breaker 3120-F...

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F...

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Control switch/load disconnect switch Series 8008

SWITCHGEAR. 4G cam switches

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Motorised and automatic transfer enclosed switchess

Single foot switches PX and PA series

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

Application Mini Contactors for Motors and Resistive Loads

ED SERIES SAFETY LIMIT SWITCH Description

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

IEC Limit Switches Selection Guide

Thermal Overcurrent Circuit Breaker 3120-F...

Phase + Neutral, neutral on left side

Position Switches Series 8074/2

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

High Performance Thermal Circuit Breaker

Installation and Operating Instructions

Limit Switch Type 4747

Transcription:

with and without a checking device The door locking devices from the AV series serve the purpose of monitoring and interlocking of 1- and 2-leaf lift landing doors. The safety locking devices fulfil the requirements of the Lift Directive 95/16/EG and the DIN EN 81-1 and -2. There are variations with die-cast enclosure as well as thermoplastic enclosure, with one or two locking elements, either in right- or left-hand versions, with lever, pull strap or built-in blocks. The safety function can be observed through the transparent cover. The locking bolt has a travel of 22 mm, so that even after the lowering of the door, the mandatory engagement depth of 16 mm is safely maintained. The emergency unlocking device can be operated externally with a triangular key. Function of the checking device The European norm DIN EN 81-1, paragraph 7.7.5.1. states: It shall not be possible, from positions normally accessible to persons, to operate the lift with a landing door open or unlocked, after one single action not forming part of the normal operating sequence. This requirement is fulfilled by our door locking devices with magnetic checking device, types AV 15, AV 20 and AV 25. The checking device functions with two permanent magnets, which with a closed door face one another with like poles, repelling each other. The magnet of the checking device is solidly connected to a locking piece, moveable in its axial direction. Consequently, the locking bolt is mechanically positively actuated to its release, the locking means contact is closed and the lift landing door is locked. On an opened lift landing door, the magnets do not face each other. As a result, the locking bolt is positively actuated and securely locked. The locking means contact is open. In the case of a fault (power failure), when the lift landing doors are opened, the locking means contact remains safeguarded from faulty locking and in the open position. 4

Technical data AV 20/21 AV 15/18, AV 25/28 Standards: DIN EN 81, Directive 95/16/EG Enclosure: fibreglass reinforced thermoplastic, light-metal die-cast self-extinguishing Protection class: IP 54 IP 20 in accordance with in accordance with IEC/EN 60529/DIN VDE 0470-1 IEC/EN 60529/DIN VDE 0470-1 Locking bolts: brass D = 18 mm Contact material: silver Switching element: changeover with double break, galvanically separated contact bridges Rated impulse withstand voltage U imp : 6 kv Rated insulation voltage U i : 500 VAC 400 VAC Thermal test current I th : 10 A Utilisation category: AC-15, DC-13 Rated operating current / voltage I e /U e : 2A/230 VAC; 2A/200 VDC Short-circuit protection: 6 A (slow blow) Emergency unlocking: with a triangular key M5 per DIN 22417 Permanent magnet: ceramic-oxide magnet with high coercive field intensity, (only for AV 20, AV 15, AV 25) flow change dependent on temperature 0.2 % / C, is however reversible Ambient temperature: 15 C... + 70 C X-dimension: 11.5, 20, 30, 40, 45 mm Installation instructions for door locking devices with magnetic checking device Chamfer 1.5 x 45 max. 3 mm 2 ø23 +0.5 principle figure of a door locking device with magnetic checking device Closing ability of the door according to DIN EN 81 The inclined section of the locking bolt allows the required closing ability of the door as required by DIN EN 81, paragraph 7.7.2.2. Corresponding to the chosen engagement depth ( or 21 mm), the door edge must be rounded off to an edge length of 30 mm in the area of the locking bolt or provided with a fender or inclined section, if necessary. The corresponding X - or Z - dimensions are to be determined when ordering. 45 R2 Z Engagement depth 45 larger penetration depth for balancing the tolerance of dimension X, for example, through lowering the door. 10 R4 30 max. 5 mm 21 X Engagement depth 5

1.4 Series AV 18 with one locking element Features light-metal die-cast enclosure without checking device protection class IP 20 10 A / 400 VAC 5 4 Condition of the door locking device with an opened and unlocked landing door With an opened landing door and a released locking means cam, the locking bolt (2) is pulled back across the angled lever (3) by pulling the pull strap (4) in direction A or by rotating the roller lever in direction B against the force of the spring (5). Consequently, the locking means switch (7) is opened. The auxiliary contact (8) is closed. 8 7 2 3 A B 4 Condition of the door locking device with a closed and locked landing door With a closed landing door (1) and with an activated locking means cam, the locking bolt (2) engages into the landing door through the effect of the spring (5) and closes the locking means switch (7). The auxiliary contact (8) is opened. 5 8 7 2 3 1 Inclined section at locking bolts various types Mounting positions 24

1.4 Series AV 18 with one locking element AV 18 RH with roller lever fig. 8 50 25 W lever position D C 16.5 36 55 25 11 ø36 25 R A 50 25 W lever position D C triangle M5 for emergency unlocking 43.5 55 11 37.5 25 X (Z) ø30 22 ø 22 20 ø 4 X (Z) adjustable by 360 18 Notice travel of locking bolt mounted with locked screws (claw washers) Dimension X or Z is to be given when placing an order (min. 11.5, max. 45 mm). Standard dimensions: 11.5, 20, 30, 40 and 45 mm The figure shows a door locking device with lever and without an auxiliary contact, with a cable entry (suffix E 1) in a right-hand version, the left-hand version is the mirror-image. Triangle M5 for emergency unlocking on rear side. 45 ø18 ø25 20.7 lever position R W actuating force at the roller cam travel [mm] [mm] initial final A-C 54 23.5 5.5 N 9 N 25 A-D 65 28 4.5 N 7 N 30 AV 18 RH IP 41 with roller lever fig. 9 ø36 R A 20 adjustable by 360 8.5 20 18 4 ø20.5 travel of locking bolt mounted with locked screws (claw washers) 45 ø18 7 20.7 Notice Dimension X or Z is to be given when placing an order (min. 25, max. 45 mm) / Z min. 35 mm. Standard dimensions: 25, 30, 40 and 45 mm. Top view without a metal cover is illustrated. The figure shows a door locking device with lever and without an auxiliary contact and with a cable entry (suffix E 1) in a right-hand version. The left-hand version is the mirror-image. lever position R W actuating force at the roller cam travel [mm] [mm] initial final A-C 54 23.5 5.5 N 9 N 25 A-D 65 28 4.5 N 7 N 30 25

1.4 Series AV 18 with one locking element description dimensions type ordering suffix door locking device with pull strap right-hand version AV 18 R door locking device with pull strap left-hand version AV 18 L door locking device with lever right-hand version see fig. 8 AV 18 RH door locking device with lever left-hand version AV 18 LH door locking device with lever right-hand version see fig. 9 AV 18 RH IP 41 1) door locking device with lever left-hand version AV 18 LH IP 41 1) door locking device with block B right-hand version AV 18 RB door locking device with block B left-hand version AV 18 LB door locking device with block B2 right-hand version AV 18 RB 2 door locking device with block B2 left-hand version AV 18 LB 2 auxiliary contact (NO) K cable entry (5 holes) E 1 cable gland Pg 16 E 4 inclined section 45 at locking bolt U 45 N (D, R, L 45 N) triangular key M5 200/350 mm Info Ordering details X-dimensions other than the above listed standard dimensions are available at additional cost. 1. door locking device AV 18 = AV 18 2. right-hand version = R 3. roller lever H = H 4. cable entry (5 holes) = E 1 5. dimension X = 30 mm = X 30 6. inclined section at locking bolt 45 bottom-side = U 45 N 1) Protection class IP 41 = AV 18 R H E 1 X 30 U 45 N 26

EC-Type Approval Certificate Certificate no.: ATV 76/4 Approval site: TÜV Bau- und Betriebstechnik GmbH Unternehmensgruppe TÜV Süddeutschland Zertifizierungsstelle für Aufzüge und Sicherheitsbauteile Westendstraße 199, D-80686 München (Kennnummer 0635) Applicant/ K.A. Schmersal GmbH & Co. Certificate holder: Möddingshofe 30 D-42279 Wuppertal Date of application: 1998-05-06 Manufacturer: Product, type: Testing laboratory: K.A. Schmersal GmbH & Co. Möddingshofe 30 D-42279 Wuppertal Interlock device with sliding latch as a component in an interlock device for landing doors, type AV 18 TÜV Bau- und Betriebstechnik GmbH Zentralabteilung Aufzüge und Sicherheitsbauteile Gottlieb-Daimler-Str. 7, D-70794 Filderstadt Date and 1998-07-04 number of test report: ATV 76/4 EC-directive Test results: 95/16/EC The safety component fulfils the basic safety requirements of the directive for the area of application described in the attached appendix of this EC-Type Approval Certificate. Date of issuance: 1998-07-04 27

Appendix to the EC-Type Approval Certificate No. ATV 76/4 from 1998-07-04 1 Range of application 1.1 Interlock device with sliding latch as a component in an interlock device for landing doors, type AV 18. 1.2 The interlock may only be used as a component of an interlock device for landing doors, provided that a separate Type Approval Certificate according to the Directive 95/16/EC is present for the co-ordination of the interlock to a particular door construction and for the existing additional components, if applicable, which are involved in the locking of the landing doors and their supervision. 1.3 Nominal values of the electrical safety devices (locking means switch): alternating current direct current 230 V, 2 A 200 V, 2 A 2 Conditions 2.1 The interlock must engage at least mm all together (or at least 8 mm for switching the electrical safety device of the interlock) into or behind the part to be locked so that the effective engagement depth of at least 7 mm is guaranteed at the departure of the car. 2.2 The approval drawing MZ 50048, edition E, pages 1 to 4 as well as the written notices and dimensions are to be abided. 2.3 For the interlock device, different * versions * mounting positions * operating devices * additional control switches (auxiliary switches) than those cited in this approval drawing may not be utilised. 2.4 The electrical safety devices for the supervision of the closed position of the landing door (door switch) have not been tested for placement nor version by this Type Approval Test of the door locking device. 2.5 Through additional measures, it must be prevented that the elevator can be put into motion with an open or unlocked door through a single, non-operational intervention (checking device). 3 Notice 3.1 For the purpose of identification and information about the principle construction, the approval drawing MZ 50048, edition E, pages 1 to 4 with a seal of approval from 04.07.1998 is to be attached with the EC-Type Approval Certificate ATV 76/4 and its appendix. 3.2 A sign with the information for identification of the component with the name of the manufacturer, the Type Approval Identification Number and the type description must be present on the interlock device. 3.3 The EC-Type Approval Certificate may only be utilised in conjunction with the obligatory appendix. 28

1.5 Series AV 21 with one locking element Features thermoplastic enclosure without checking device protection class IP 54 10 A / 500 VAC Condition of the door locking device with an opened and unlocked landing door With an opened landing door and a released locking means cam, the locking bolt (2) is pulled back across the angled lever (3) by pulling the pull strap (4) in direction A or by rotating the roller lever in direction B against the force of the spring (5). Consequently, the locking means switch (7) is opened and the auxiliary contact (8) is closed. Condition of the door locking device with a closed and locked landing door With a closed landing door (1) and an activated locking means cam, the locking bolt (2) engages by the effect of the spring (5) into the landing door (1) and closes the locking means switch (7). The auxiliary contact (8) is opened. 29

1.5 Series AV 21 with one locking element Inclined section at locking bolts various types Mounting positions Standard contact equipment Locking means contact Auxiliary contact 30

1.5 Series AV 21 with one locking element AV 21 with pull strap fig. 10 F= 7N initial F=N final triangle M5 for emergency unlocking on rear side travel of locking bolt Notice The figure shows a door locking device in the left-hand version, the right-hand version is mirror-image. Dimension X is to be given when placing an order. Standard dimensions: 11.5, 20, 30, 40 and 45 mm. description dimensions type ordering suffix door locking device with pull strap right-hand version AV 21 R door locking device with pull strap left-hand version see fig. 10 AV 21 L door locking device with lever right-hand version AV 21 RH door locking device with lever left-hand version AV 21 LH door locking device with block B right-hand version AV 21 RB door locking device with block B left-hand version AV 21 LB door locking device with block B2 right-hand version AV 21 RB 2 door locking device with block B2 left-hand version AV 21 LB 2 cable entry (4 holes) E 2 cable gland Pg 16 E 4 inclined section 45 at locking bolt U 45 (D, R, L) triangular key M5 200/350 mm Ordering details 1. door locking device AV 21 = AV 21 2. left-hand version = L 3. cable entry (4 holes) = E 2 4. dimension X = 30 mm = X 30 5. inclined section at locking bolt 45 bottom-side = U = AV 21 L E 2 X 30 U 31

EC-Type Approval Certificate Certificate no.: ATV 529 Approval site: TÜV Bau- und Betriebstechnik GmbH Unternehmensgruppe TÜV Süddeutschland Zertifizierungsstelle für Aufzüge und Sicherheitsbauteile Westendstraße 199, D-80686 München (Kennnummer 0635) Applicant/ K.A. Schmersal GmbH & Co. Certificate holder: Möddingshofe 30 D-42279 Wuppertal Date of application: 1998-05-06 Manufacturer: Product, type: Testing laboratory: K.A. Schmersal GmbH & Co. Möddingshofe 30 D-42279 Wuppertal Interlock with sliding latch in a waterproof version as a component of an interlock device for landing doors, type AV 21 TÜV Bau- und Betriebstechnik GmbH Zentralabteilung Aufzüge und Sicherheitsbauteile Gottlieb-Daimler-Str. 7, D-70794 Filderstadt Date and 1998-07-07 number of test report: ATV 529 EU-Directive: Test results: 95/16/EC The safety component fulfils the basic safety requirements of the directive for the area of application described in the attached appendix of this EC-Type Approval Certificate. Date of issuance: 1998-07-07 32

Appendix to the EC-Type Approval Certificate No. ATV 529 from 1998-07-07 1 Range of application 1.1 Interlock with sliding latch in a waterproof version as a component in an interlock device for landing doors, type AV 21. 1.2 The interlock may only be used as a component of an interlock device for landing doors, provided that a separate Type Approval Certificate according to the Directive 95/16/EC is present for the coordination of the interlock to a particular door construction and for the existing additional components, if applicable, which are involved in the locking of the landing doors and their supervision. 1.3 Nominal values of the electrical safety devices (locking means switch): alternating current direct current 230 V, 2 A 200 V, 2 A 2 Conditions 2.1 The interlock must engage at least mm all together (or at least 8 mm for switching the electrical safety device of the interlock) into or behind the part to be locked so that the effective engagement depth of at least 7 mm is guaranteed at the departure of the car. 2.2 The approval drawing MZ.50119-51A, edition 07.97, pages 1 to 5 as well as the written notices and dimensions are to be abided. 2.3 For the interlock device, different * versions * mounting positions * operating devices than those cited in this approval drawing may not be utilised. 2.4 The electrical safety devices for the supervision of the closed position of the landing door (door switch) have not been tested for placement nor version by this Type Approval Test of the door locking device. 2.5 Through additional measures, it must be prevented that the elevator can be put into motion with an open or unlocked door through a single, non-operational intervention (checking device). 3 Notice 3.1 For the purpose of identification and information about the principle construction, the approval drawing MZ.50119-51A, edition 07.97, pages 1 to 5 with a seal of approval from 07.07.1998 is to be attached with the EC-Type Approval Certificate ATV 529 and its appendix. 3.2 A sign with the information for identification of the component with the name of the manufacturer, the Type Approval Identification Number and the type description must be present on the interlock device. 3.3 The EC-Type Approval Certificate may only be utilised in conjunction with the obligatory appendix. 33

lever position 1. 1.7 Accessories AY 03 Bearing block with lever for door locking device with pull strap fig. 70 20 34 3 28 ø5 9. 50 Y* R 35 ø 39 24 8 A B ø36 11 25 55 26 36 8 lever adjustable by 360 W C D Notice *Pull bar dimension Y is to be given when placing an order max. dimension Y = 1000 mm lever position R W cam travel max. actuation force on the roller in door locking devices [mm] [mm] AV 15 AV 18 AV 25 AV 28 B-C 41 21 25 9.5 N 9.5 N 22.5 N 22.5 N B-D 52 27 30 7.5 N 7.5 N 18.0 N 18.0 N A-D 65 34 40 6.0 N 6.0 N 14.0 N 14.0 N description weight [g] type ordering suffix bearing block 350 AY 03 pull bar, *length as ordered Y Ordering details 1. bearing block = AY 03 2. dimension Y = 450 mm = Y 450 = AY 03 Y 450 39

1.7 Accessories AW 01 Angled transmission (i= 1:1) with lever fig. 13 W 3 28 11 25 81 D C ø5 R ø36 27 Y* 35 ø 9. A 24 48 11 8 8 48 adjustable by 360 26 36 59 50 70 77 Notice * Pull bar dimension Y is to be given when placing an order max. dimension Y = 1000 mm. The figure shows the left-hand version, the right-hand version is the mirror-image. lever position R W cam travel max. actuation force on the roller in door locking devices [mm] [mm] AV 15 AV 18 AV 25 AV 28 A-C 54 28 35 7 N 7 N 17 N 17 N A-D 65 34 40 6 N 6 N 14 N 14 N description weight [g] type ordering suffix angle transmission, right-hand version 550 AW 01 R angle transmission, left-hand version 550 AW 01 L pull bar, *length as ordered Y Ordering details 1. angle transmission = AW 01 2. right-hand version = R 3. dimension Y = 450 mm = Y 450 = AW 01 R Y 450 40

1.7 Accessories H 92, H 105 Lever for door locking device H 92 25 65 25 11 ø36 92 adjustable by 360 64 Lever for door locking device H 105 25 65 25 11 ø36 105 adjustable by by 360 360 64 41